-
Tumor likelihood estimation on MRI prostate data by utilizing k-Space information
Authors:
M. Rempe,
F. Hörst,
C. Seibold,
B. Hadaschik,
M. Schlimbach,
J. Egger,
K. Kröninger,
F. Breuer,
M. Blaimer,
J. Kleesiek
Abstract:
We present a novel preprocessing and prediction pipeline for the classification of magnetic resonance imaging (MRI) that takes advantage of the information rich complex valued k-Space. Using a publicly available MRI raw dataset with 312 subject and a total of 9508 slices, we show the advantage of utilizing the k-Space for better prostate cancer likelihood estimation in comparison to just using the…
▽ More
We present a novel preprocessing and prediction pipeline for the classification of magnetic resonance imaging (MRI) that takes advantage of the information rich complex valued k-Space. Using a publicly available MRI raw dataset with 312 subject and a total of 9508 slices, we show the advantage of utilizing the k-Space for better prostate cancer likelihood estimation in comparison to just using the magnitudinal information in the image domain, with an AUROC of $86.1\%\pm1.8\%$. Additionally, by using high undersampling rates and a simple principal component analysis (PCA) for coil compression, we reduce the time needed for reconstruction by avoiding the time intensive GRAPPA reconstruction algorithm. By using digital undersampling for our experiments, we show that scanning and reconstruction time could be reduced. Even with an undersampling factor of 16, our approach achieves meaningful results, with an AUROC of $71.4\%\pm2.9\%$, using the PCA coil combination and taking into account the k-Space information. With this study, we were able to show the feasibility of preserving phase and k-Space information, with consistent results. Besides preserving valuable information for further diagnostics, this approach can work without the time intensive ADC and reconstruction calculations, greatly reducing the post processing, as well as potential scanning time, increasing patient comfort and allowing a close to real-time prediction.
△ Less
Submitted 4 June, 2024;
originally announced July 2024.
-
A novel image space formalism of Fourier domain interpolation neural networks for noise propagation analysis
Authors:
Peter Dawood,
Felix Breuer,
Istvan Homolya,
Jannik Stebani,
Maximilian Gram,
Peter M. Jakob,
Moritz Zaiss,
Martin Blaimer
Abstract:
Purpose: To develop an image space formalism of multi-layer convolutional neural networks (CNNs) for Fourier domain interpolation in MRI reconstructions and analytically estimate noise propagation during CNN inference. Theory and Methods: Nonlinear activations in the Fourier domain (also known as k-space) using complex-valued Rectifier Linear Units are expressed as elementwise multiplication with…
▽ More
Purpose: To develop an image space formalism of multi-layer convolutional neural networks (CNNs) for Fourier domain interpolation in MRI reconstructions and analytically estimate noise propagation during CNN inference. Theory and Methods: Nonlinear activations in the Fourier domain (also known as k-space) using complex-valued Rectifier Linear Units are expressed as elementwise multiplication with activation masks. This operation is transformed into a convolution in the image space. After network training in k-space, this approach provides an algebraic expression for the derivative of the reconstructed image with respect to the aliased coil images, which serve as the input tensors to the network in the image space. This allows the variance in the network inference to be estimated analytically and to be used to describe noise characteristics. Monte-Carlo simulations and numerical approaches based on auto-differentiation were used for validation. The framework was tested on retrospectively undersampled invivo brain images. Results: Inferences conducted in the image domain are quasi-identical to inferences in the k-space, underlined by corresponding quantitative metrics. Noise variance maps obtained from the analytical expression correspond with those obtained via Monte-Carlo simulations, as well as via an auto-differentiation approach. The noise resilience is well characterized, as in the case of classical Parallel Imaging. Komolgorov-Smirnov tests demonstrate Gaussian distributions of voxel magnitudes in variance maps obtained via Monte-Carlo simulations. Conclusion: The quasi-equivalent image space formalism for neural networks for k-space interpolation enables fast and accurate description of the noise characteristics during CNN inference, analogous to geometry-factor maps in traditional parallel imaging methods.
△ Less
Submitted 27 February, 2024;
originally announced February 2024.
-
Rotary Excitation of non-sinusoidal pulsed magnetic fields: Towards non-invasive direct detection of cardiac conduction
Authors:
Petra Albertova,
Maximilian Gram,
Martin Blaimer,
Wolfgang R Bauer,
Peter M Jakob,
Peter Nordbeck
Abstract:
Purpose: In the recent past, spin-locking MRI experiments were successfully applied for the direct detection of sinusoidal magnetic field oscillations in the sub-nT range. In the present study, this detection approach was extended to non-sinusoidal pulsed magnetic fields based on the Rotary Excitation (REX) mechanism. Methods: The new detection concept was examined by means of Bloch simulations, e…
▽ More
Purpose: In the recent past, spin-locking MRI experiments were successfully applied for the direct detection of sinusoidal magnetic field oscillations in the sub-nT range. In the present study, this detection approach was extended to non-sinusoidal pulsed magnetic fields based on the Rotary Excitation (REX) mechanism. Methods: The new detection concept was examined by means of Bloch simulations, evaluating the interaction effect of spin-locked magnetization and low-frequency pulsed magnetic fields. The REX detection approach was validated under controlled conditions in phantom experiments at 3T. Gaussian and Sinc-shaped stimuli were investigated. In addition, the detection of artificial fields resembling a cardiac QRS complex, which is the most prominent peak visible on a Magnetocardiogram, was tested. Results: Bloch simulations demonstrated that the REX method has a high sensitivity to pulsed fields in the resonance case, which is met when the spin-lock frequency coincides with a non-zero Fourier component of the stimulus field. In the experiments, we found that magnetic stimuli of different durations and waveforms can be distinguished by their characteristic REX response spectrum. The detected REX amplitude was proportional to the stimulus peak amplitude (R2>0.98) and the lowest field detection was 1 nT. Furthermore, the detection of QRS-like fields with varying QRS durations yielded significant results in a phantom setup (p<0.001). Conclusion: REX detection can be transferred to non-sinusoidal pulsed magnetic fields and could provide a non-invasive, quantitative tool for spatially resolved assessment of cardiac biomagnetism. Potential applications include the direct detection and characterization of cardiac conduction.
△ Less
Submitted 26 April, 2024; v1 submitted 24 November, 2023;
originally announced November 2023.
-
Iterative training of robust k-space interpolation networks for improved image reconstruction with limited scan specific training samples
Authors:
Peter Dawood,
Felix Breuer,
Paul R. Burd,
István Homolya,
Johannes Oberberger,
Peter M. Jakob,
Martin Blaimer
Abstract:
Purpose: To evaluate an iterative learning approach for enhanced performance of Robust Artificial-neural-networks for K-space Interpolation (RAKI), when only a limited amount of training data (auto-calibration signals, ACS) are available for accelerated standard 2D imaging. Methods: In a first step, the RAKI model was optimized for the case of strongly limited training data amount. In the iterativ…
▽ More
Purpose: To evaluate an iterative learning approach for enhanced performance of Robust Artificial-neural-networks for K-space Interpolation (RAKI), when only a limited amount of training data (auto-calibration signals, ACS) are available for accelerated standard 2D imaging. Methods: In a first step, the RAKI model was optimized for the case of strongly limited training data amount. In the iterative learning approach (termed iterative RAKI), the optimized RAKI model is initially trained using original and augmented ACS obtained from a linear parallel imaging reconstruction. Subsequently, the RAKI convolution filters are refined iteratively using original and augmented ACS extracted from the previous RAKI reconstruction. Evaluation was carried out on 200 retrospectively undersampled in-vivo datasets from the fastMRI neuro database with different contrast settings. Results: For limited training data (18 and 22 ACS lines for R=4 and R=5, respectively), iterative RAKI outperforms standard RAKI by reducing residual artefacts and yields strong noise suppression when compared to standard parallel imaging, underlined by quantitative reconstruction quality metrics. In combination with a phase constraint, further reconstruction improvements can be achieved. Additionally, iterative RAKI shows better performance than both GRAPPA and RAKI in case of pre-scan calibration with varying contrast between training- and undersampled data. Conclusion: The iterative learning approach with RAKI benefits from standard RAKIs well known noise suppression feature but requires less original training data for the accurate reconstruction of standard 2D images thereby improving net acceleration.
△ Less
Submitted 14 July, 2022; v1 submitted 10 January, 2022;
originally announced January 2022.