-
First radial velocity results from the MINiature Exoplanet Radial Velocity Array (MINERVA)
Authors:
Maurice L. Wilson,
Jason D. Eastman,
Matthew A. Cornachione,
Sharon X. Wang,
Samson A. Johnson,
David H. Sliski,
William J. Schap III,
Timothy D. Morton,
John Asher Johnson,
Nate McCrady,
Jason T. Wright,
Robert A. Wittenmyer,
Peter Plavchan,
Cullen H. Blake,
Jonathan J. Swift,
Michael Bottom,
Ashley D. Baker,
Stuart I. Barnes,
Perry Berlind,
Eric Blackhurst,
Thomas G. Beatty,
Adam S. Bolton,
Bryson Cale,
Michael L. Calkins,
Ana Colón
, et al. (30 additional authors not shown)
Abstract:
The MINiature Exoplanet Radial Velocity Array (MINERVA) is a dedicated observatory of four 0.7m robotic telescopes fiber-fed to a KiwiSpec spectrograph. The MINERVA mission is to discover super-Earths in the habitable zones of nearby stars. This can be accomplished with MINERVA's unique combination of high precision and high cadence over long time periods. In this work, we detail changes to the MI…
▽ More
The MINiature Exoplanet Radial Velocity Array (MINERVA) is a dedicated observatory of four 0.7m robotic telescopes fiber-fed to a KiwiSpec spectrograph. The MINERVA mission is to discover super-Earths in the habitable zones of nearby stars. This can be accomplished with MINERVA's unique combination of high precision and high cadence over long time periods. In this work, we detail changes to the MINERVA facility that have occurred since our previous paper. We then describe MINERVA's robotic control software, the process by which we perform 1D spectral extraction, and our forward modeling Doppler pipeline. In the process of improving our forward modeling procedure, we found that our spectrograph's intrinsic instrumental profile is stable for at least nine months. Because of that, we characterized our instrumental profile with a time-independent, cubic spline function based on the profile in the cross dispersion direction, with which we achieved a radial velocity precision similar to using a conventional "sum-of-Gaussians" instrumental profile: 1.8 m s$^{-1}$ over 1.5 months on the RV standard star HD 122064. Therefore, we conclude that the instrumental profile need not be perfectly accurate as long as it is stable. In addition, we observed 51 Peg and our results are consistent with the literature, confirming our spectrograph and Doppler pipeline are producing accurate and precise radial velocities.
△ Less
Submitted 11 September, 2019; v1 submitted 22 April, 2019;
originally announced April 2019.
-
The QUIJOTE CMB Experiment: status and first results with the multi-frequency instrument
Authors:
M. López-Caniego,
R. Rebolo,
M. Aguiar,
R. Génova-Santos,
F. Gómez-Reñasco,
C. Gutierrez,
J. M. Herreros,
R. J. Hoyland,
C. López-Caraballo,
A. E. Pelaez Santos,
F. Poidevin,
J. A. Rubiño-Martín,
V. Sanchez de la Rosa,
D. Tramonte,
A. Vega-Moreno,
T. Viera-Curbelo,
R. Vignaga,
E. Martínez-González,
R. B. Barreiro,
B. Casaponsa,
F. J. Casas,
J. M. Diego,
R. Fernández-Cobos,
D. Herranz,
D. Ortiz
, et al. (27 additional authors not shown)
Abstract:
The QUIJOTE (Q-U-I JOint Tenerife) CMB Experiment is designed to observe the polarization of the Cosmic Microwave Background and other Galactic and extragalactic signals at medium and large angular scales in the frequency range of 10-40 GHz. The first of the two QUIJOTE telescopes and the multi-frequency (10-20 GHz) instrument have been in operation since November 2012. In 2014 a second telescope…
▽ More
The QUIJOTE (Q-U-I JOint Tenerife) CMB Experiment is designed to observe the polarization of the Cosmic Microwave Background and other Galactic and extragalactic signals at medium and large angular scales in the frequency range of 10-40 GHz. The first of the two QUIJOTE telescopes and the multi-frequency (10-20 GHz) instrument have been in operation since November 2012. In 2014 a second telescope and a new instrument at 30GHz will be ready for commissioning, and an additional instrument at 40 GHz is in its final design stages. After three years of effective observations, the data obtained by these telescopes and instruments will have the required sensitivity to detect a primordial gravitational-wave component if the tensor-to-scalar ratio is larger than r = 0.05. At the moment, we have completed half of the wide Galactic survey with the multi-frequency instrument covering 18 000 square degrees of the Northern hemisphere. When we finish this survey in early 2014, we shall have reached approximately 14μK per one degree beam at 11, 13, 17 and 19 GHz, in both Q and U.
△ Less
Submitted 5 February, 2014; v1 submitted 19 January, 2014;
originally announced January 2014.
-
The C-Band All-Sky Survey (C-BASS): Design and implementation of the northern receiver
Authors:
O. G. King,
Michael E. Jones,
E. J. Blackhurst,
C. Copley,
R. J. Davis,
C. Dickinson,
C. M. Holler,
M. O. Irfan,
J. J. John,
J. P. Leahy,
J. Leech,
S. J. C. Muchovej,
T. J. Pearson,
M. A. Stevenson,
Angela C. Taylor
Abstract:
The C-Band All-Sky Survey (C-BASS) is a project to map the full sky in total intensity and linear polarization at 5 GHz. The northern component of the survey uses a broadband single-frequency analogue receiver fitted to a 6.1-m telescope at the Owens Valley Radio Observatory in California, USA. The receiver architecture combines a continuous-comparison radiometer and a correlation polarimeter in a…
▽ More
The C-Band All-Sky Survey (C-BASS) is a project to map the full sky in total intensity and linear polarization at 5 GHz. The northern component of the survey uses a broadband single-frequency analogue receiver fitted to a 6.1-m telescope at the Owens Valley Radio Observatory in California, USA. The receiver architecture combines a continuous-comparison radiometer and a correlation polarimeter in a single receiver for stable simultaneous measurement of both total intensity and linear polarization, using custom-designed analogue receiver components. The continuous-comparison radiometer measures the temperature difference between the sky and temperature-stabilized cold electrical reference loads. A cryogenic front-end is used to minimize receiver noise, with a system temperature of $\approx 30\,$K in both linear polarization and total intensity. Custom cryogenic notch filters are used to counteract man-made radio frequency interference. The radiometer $1/f$ noise is dominated by atmospheric fluctuations, while the polarimeter achieves a $1/f$ noise knee frequency of 10 mHz, similar to the telescope azimuthal scan frequency.
△ Less
Submitted 3 December, 2013; v1 submitted 26 October, 2013;
originally announced October 2013.
-
Planck pre-launch status: calibration of the Low Frequency Instrument flight model radiometers
Authors:
F. Villa,
L. Terenzi,
M. Sandri,
P. Meinhold,
T. Poutanen,
P. Battaglia,
C. Franceschet,
N. Hughes,
M. Laaninen,
P. Lapolla,
M. Bersanelli,
R. C. Butler,
F. Cuttaia,
O. D'Arcangelo,
M. Frailis,
E. Franceschi,
S. Galeotta,
A. Gregorio,
R. Leonardi,
S. R. Lowe,
N. Mandolesi,
M. Maris,
L. Mendes,
A. Mennella,
G. Morgante
, et al. (49 additional authors not shown)
Abstract:
The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries eleven radiometer subsystems, called Radiometer Chain Assemblies (RCAs), each composed of a pair of pseudo-correlation receivers. We describe the on-ground calibration campaign performed to qualify the flight model RCAs and to measure their pre-launch performances. Each RCA was calibrated in a dedicated flight-like cryoge…
▽ More
The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries eleven radiometer subsystems, called Radiometer Chain Assemblies (RCAs), each composed of a pair of pseudo-correlation receivers. We describe the on-ground calibration campaign performed to qualify the flight model RCAs and to measure their pre-launch performances. Each RCA was calibrated in a dedicated flight-like cryogenic environment with the radiometer front-end cooled to 20K and the back-end at 300K, and with an external input load cooled to 4K. A matched load simulating a blackbody at different temperatures was placed in front of the sky horn to derive basic radiometer properties such as noise temperature, gain, and noise performance, e.g. 1/f noise. The spectral response of each detector was measured as was their susceptibility to thermal variation. All eleven LFI RCAs were calibrated. Instrumental parameters measured in these tests, such as noise temperature, bandwidth, radiometer isolation, and linearity, provide essential inputs to the Planck-LFI data analysis.
△ Less
Submitted 14 May, 2010;
originally announced May 2010.
-
Design, development and verification of the 30 and 44 GHz front-end modules for the Planck Low Frequency Instrument
Authors:
R. J. Davis,
A. Wilkinson,
R. D. Davies,
W. F. Winder,
N. Roddis,
E. J. Blackhurst,
D. Lawson,
S. R. Lowe,
C. Baines,
M. Butlin,
A. Galtress,
D. Shepherd,
B. Aja,
E. Artal,
M. Bersanelli,
R. C. Butler,
C. Castelli,
F. Cuttaia,
O. D'Arcangelo,
T. Gaier,
R. Hoyland,
D. Kettle,
R. Leonardi,
N. Mandolesi,
A. Mennella
, et al. (6 additional authors not shown)
Abstract:
We give a description of the design, construction and testing of the 30 and 44 GHz Front End Modules (FEMs) for the Low Frequency Instrument (LFI) of the Planck mission to be launched in 2009. The scientific requirements of the mission determine the performance parameters to be met by the FEMs, including their linear polarization characteristics.
The FEM design is that of a differential pseudo…
▽ More
We give a description of the design, construction and testing of the 30 and 44 GHz Front End Modules (FEMs) for the Low Frequency Instrument (LFI) of the Planck mission to be launched in 2009. The scientific requirements of the mission determine the performance parameters to be met by the FEMs, including their linear polarization characteristics.
The FEM design is that of a differential pseudo-correlation radiometer in which the signal from the sky is compared with a 4-K blackbody load. The Low Noise Amplifier (LNA) at the heart of the FEM is based on indium phosphide High Electron Mobility Transistors (HEMTs). The radiometer incorporates a novel phase-switch design which gives excellent amplitude and phase match across the band.
The noise temperature requirements are met within the measurement errors at the two frequencies. For the most sensitive LNAs, the noise temperature at the band centre is 3 and 5 times the quantum limit at 30 and 44 GHz respectively. For some of the FEMs, the noise temperature is still falling as the ambient temperature is reduced to 20 K. Stability tests of the FEMs, including a measurement of the 1/f knee frequency, also meet mission requirements.
The 30 and 44 GHz FEMs have met or bettered the mission requirements in all critical aspects. The most sensitive LNAs have reached new limits of noise temperature for HEMTs at their band centres. The FEMs have well-defined linear polarization characteristcs.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
Noise Properties of the Planck-LFI Receivers
Authors:
P. Meinhold,
R. Leonardi,
B. Aja,
E. Artal,
P. Battaglia,
M. Bersanelli,
E. Blackhurst,
C. R. Butler,
L. P. Cuevas,
F. Cuttaia,
O. D'Arcangelo,
R. Davis,
M. L. de la Fuente,
M. Frailis,
C. Franceschet,
E. Franceschi,
T. Gaier,
S. Galeotta,
A. Gregorio,
R. Hoyland,
N. Hughes,
P. Jukkala,
D. Kettle,
M. Laaninen,
P. Leutenegger
, et al. (25 additional authors not shown)
Abstract:
The Planck Low Frequency Instrument (LFI) radiometers have been tested extensively during several dedicated campaigns. The present paper reports the principal noise properties of the LFI radiometers.
The Planck Low Frequency Instrument (LFI) radiometers have been tested extensively during several dedicated campaigns. The present paper reports the principal noise properties of the LFI radiometers.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
Planck pre-launch status: Design and description of the Low Frequency Instrument
Authors:
M. Bersanelli,
N. Mandolesi,
R. C. Butler,
A. Mennella,
F. Villa,
B. Aja,
E. Artal,
E. Artina,
C. Baccigalupi,
M. Balasini,
G. Baldan,
A. Banday,
P. Bastia,
P. Battaglia,
T. Bernardino,
E. Blackhurst,
L. Boschini,
C. Burigana,
G. Cafagna,
B. Cappellini,
F. Cavaliere,
F. Colombo,
G. Crone,
F. Cuttaia,
O. D'Arcangelo
, et al. (87 additional authors not shown)
Abstract:
In this paper we present the Low Frequency Instrument (LFI), designed and developed as part of the Planck space mission, the ESA program dedicated to precision imaging of the cosmic microwave background (CMB). Planck-LFI will observe the full sky in intensity and polarisation in three frequency bands centred at 30, 44 and 70 GHz, while higher frequencies (100-850 GHz) will be covered by the HFI…
▽ More
In this paper we present the Low Frequency Instrument (LFI), designed and developed as part of the Planck space mission, the ESA program dedicated to precision imaging of the cosmic microwave background (CMB). Planck-LFI will observe the full sky in intensity and polarisation in three frequency bands centred at 30, 44 and 70 GHz, while higher frequencies (100-850 GHz) will be covered by the HFI instrument. The LFI is an array of microwave radiometers based on state-of-the-art Indium Phosphide cryogenic HEMT amplifiers implemented in a differential system using blackbody loads as reference signals. The front-end is cooled to 20K for optimal sensitivity and the reference loads are cooled to 4K to minimise low frequency noise. We provide an overview of the LFI, discuss the leading scientific requirements and describe the design solutions adopted for the various hardware subsystems. The main drivers of the radiometric, optical and thermal design are discussed, including the stringent requirements on sensitivity, stability, and rejection of systematic effects. Further details on the key instrument units and the results of ground calibration are provided in a set of companion papers.
△ Less
Submitted 19 January, 2010;
originally announced January 2010.
-
Advanced pseudo-correlation radiometers for the Planck-LFI instrument
Authors:
A. Mennella,
M. Bersanelli,
R. C. Butler,
D. Maino,
N. Mandolesi,
G. Morgante,
L. Valenziano,
F. Villa,
T. Gaier,
M. Seiffert,
S. Levin,
C. Lawrence,
P. Meinhold,
P. Lubin,
J. Tuovinen,
J. Varis,
T. Karttaavi,
N. Hughes,
P. Jukkala,
P. Sjman,
P. Kangaslahti,
N. Roddis,
D. Kettle,
F. Winder,
E. Blackhurst
, et al. (12 additional authors not shown)
Abstract:
The LFI (Low Frequency Instrument) on board the ESA Planck satellite is constituted by an array of radiometric detectors actively cooled at 20 K in the 30-70 GHz frequency range in the focal plane of the Planck telescope. In this paper we present an overview of the LFI instrument, with a particular focus on the radiometer design. The adopted pseudo-correlation scheme uses a software balancing te…
▽ More
The LFI (Low Frequency Instrument) on board the ESA Planck satellite is constituted by an array of radiometric detectors actively cooled at 20 K in the 30-70 GHz frequency range in the focal plane of the Planck telescope. In this paper we present an overview of the LFI instrument, with a particular focus on the radiometer design. The adopted pseudo-correlation scheme uses a software balancing technique (with a tunable parameter called gain modulation factor) which is effective in reducing the radiometer susceptibility to amplifier instabilities also in presence of small non-idealities in the radiometric chain components, provided that the gain modulation factor is estimated with an accuracy of the order of 0.2%. These results have been recently confirmed by experimental laboratory measurements conducted on the LFI prototype radiometers at 30, 70 and 100 GHz.
△ Less
Submitted 7 July, 2003;
originally announced July 2003.