The Design and Construction of the Chips Water Cherenkov Neutrino Detector
Authors:
B. Alonso Rancurel,
N. Angelides,
G. Augustoni,
S. Bash,
B. Bergmann,
N. Bertschinger,
P. Bizouard,
M. Campbell,
S. Cao,
T. J. Carroll,
R. Castellan,
E. Catano-Mur,
J. P. Cesar,
J. A. B. Coelho,
P. Dills,
T. Dodwell,
J. Edmondson,
D. van Eijk,
Q. Fetterly,
Z. Garbal,
S. Germani,
T. Gilpin,
A. Giraudo,
A. Habig,
D. Hanuska
, et al. (42 additional authors not shown)
Abstract:
CHIPS (CHerenkov detectors In mine PitS) was a prototype large-scale water Cherenkov detector located in northern Minnesota. The main aim of the R&D project was to demonstrate that construction costs of neutrino oscillation detectors could be reduced by at least an order of magnitude compared to other equivalent experiments. This article presents design features of the CHIPS detector along with de…
▽ More
CHIPS (CHerenkov detectors In mine PitS) was a prototype large-scale water Cherenkov detector located in northern Minnesota. The main aim of the R&D project was to demonstrate that construction costs of neutrino oscillation detectors could be reduced by at least an order of magnitude compared to other equivalent experiments. This article presents design features of the CHIPS detector along with details of the implementation and deployment of the prototype. While issues during and after the deployment of the detector prevented data taking, a number of key concepts and designs were successfully demonstrated.
△ Less
Submitted 22 January, 2024;
originally announced January 2024.
Measuring the Attenuation Length of Water in the CHIPS-M Water Cherenkov Detector
Authors:
F. Amat,
P. Bizouard,
J. Bryant,
T. J. Carroll,
S. De Rijck,
S. Germani,
T. Joyce,
B. Kreisten,
M. Marshak,
J. Meier,
J. Nelson,
A. J. Perch,
M. M. Pfuzner,
R. Salazar,
J. Thomas,
J. Trokan-Tenorio,
P. Vahle,
R. Wade,
C. Wendt,
L. H. Whitehead,
M. Whitney
Abstract:
The water at the proposed site of the CHIPS water Cherenkov detector has been studied to measure its attenuation length for Cherenkov light as a function of filtering time. A scaled model of the CHIPS detector filled with water from the Wentworth 2W pit, proposed site of the CHIPS deployment, in conjunction with a 3.2\unit{m} vertical column filled with this water, was used to study the transmissi…
▽ More
The water at the proposed site of the CHIPS water Cherenkov detector has been studied to measure its attenuation length for Cherenkov light as a function of filtering time. A scaled model of the CHIPS detector filled with water from the Wentworth 2W pit, proposed site of the CHIPS deployment, in conjunction with a 3.2\unit{m} vertical column filled with this water, was used to study the transmission of 405nm laser light. Results consistent with attenuation lengths of up to 100m were observed for this wavelength with filtration and UV sterilization alone.
△ Less
Submitted 19 November, 2016; v1 submitted 21 October, 2016;
originally announced October 2016.