-
Shear band relaxation in a deformed bulk metallic glass
Authors:
I. Binkowski,
G. P. Shrivastav,
J. Horbach,
S. V. Divinski,
G. Wilde
Abstract:
Relaxation of shear bands in a Pd40Ni40P20 bulk metallic glass was investigated by a combination of radiotracer diffusion and molecular dynamics (MD) simulations, allowing to determine for the first time the effective activation enthalpy of diffusion along shear bands in a deformed glass. The shear bands relax during annealing below the glass transition temperature and the diffusion enhancement re…
▽ More
Relaxation of shear bands in a Pd40Ni40P20 bulk metallic glass was investigated by a combination of radiotracer diffusion and molecular dynamics (MD) simulations, allowing to determine for the first time the effective activation enthalpy of diffusion along shear bands in a deformed glass. The shear bands relax during annealing below the glass transition temperature and the diffusion enhancement reveals unexpectedly a non-monotonous behavior. The development of shear bands and the subsequent relaxation of stresses after switching off the shearing are characterized on microscopic to mesoscopic length scales by MD simulation subjecting the model glass to a constant strain rate. Mean-squared displacements as well as strain maps indicate that the heterogeneity, as manifested by shear bands in the systems under shear, persist after the shear is switched off. We observe a further relaxation of residual stresses that remain localized in regions where the shear band has been present before, although the system is - different from the macroscopic experiment - homogeneous with respect to the local density. These results indicate that even on a local scale one may expect strong dynamic heterogeneity in deformed glassy solids due to shear banding. The results thus suggest that plastically deformed metallic glasses present poly-amorphous systems that necessitate descriptions that are analogous to multiphase materials including the presence of heterophase interfaces.
△ Less
Submitted 14 September, 2015; v1 submitted 9 June, 2015;
originally announced June 2015.
-
Sub-micron strain analysis of local stick-slip motion of individual shear bands in a bulk metallic glass
Authors:
I. Binkowski,
S. Schlottbom,
J. Leuthold,
S. Ostendorp,
S. V. Divinski,
G. Wilde
Abstract:
Nanodot deposition on a side surface of a rectangular sample and digital image correlation are used to quantify the in-plane strain fields associated with the propagation of a shear band in a PdNiP bulk metallic glass,induced by rolling. Within the resolution of the method related to an average inter-dot distance of 100 nm, deformation is found to be highly localized at the shear bands, while alte…
▽ More
Nanodot deposition on a side surface of a rectangular sample and digital image correlation are used to quantify the in-plane strain fields associated with the propagation of a shear band in a PdNiP bulk metallic glass,induced by rolling. Within the resolution of the method related to an average inter-dot distance of 100 nm, deformation is found to be highly localized at the shear bands, while alternating areas with a size of 100 - 400 nm with opposite local shear strains are found. This phenomenon substantiates a local stick-slip nature of shear band propagation during the metallic glass deformation, even during rolling.
△ Less
Submitted 8 June, 2015;
originally announced June 2015.
-
Impact of micro-alloying on the plasticity of Pd-based Bulk Metallic Glasses
Authors:
N. Nollmann,
I. Binkowski,
V. Schmidt,
H. Rösner,
G. Wilde
Abstract:
Micro-alloying was performed using additions of Co and Fe to monolithic Pd40Ni40P20 bulk metallic glass to study selectively the influence on the plastic behavior in uniaxial compression and three-point bending tests. The corresponding Poisson's ratios were determined by ultrasonic measurements. The microstructure of the individual bulk metallic glasses was characterized by electron microscopy, X-…
▽ More
Micro-alloying was performed using additions of Co and Fe to monolithic Pd40Ni40P20 bulk metallic glass to study selectively the influence on the plastic behavior in uniaxial compression and three-point bending tests. The corresponding Poisson's ratios were determined by ultrasonic measurements. The microstructure of the individual bulk metallic glasses was characterized by electron microscopy, X-ray diffraction and calorimetry. A plastic strain of 13% was found for the Co addition (1 at.%), whereas the Fe addition (0.6 at.%) led to immediate failure after reaching the elastic limit. Surprisingly, the plasticity is not reflected by the high Poisson's ratio of 0.4 since it remained unaffected by the minor alloying.
△ Less
Submitted 8 June, 2015;
originally announced June 2015.