Skip to main content

Showing 1–18 of 18 results for author: Bigot-Sazy, M

.
  1. QUBIC IV: Performance of TES Bolometers and Readout Electronics

    Authors: M. Piat, G. Stankowiak, E. S. Battistelli, P. de Bernardis, G. D Alessandro, M. De Petris, L. Grandsire, J. -Ch. Hamilton, T. D. Hoang, S. Marnieros, S. Masi, A. Mennella, L. Mousset, C. O Sullivan, D. Prele, A. Tartari, J. -P. Thermeau, S. A. Torchinsky, F. Voisin, M. Zannoni, P. Ade, J. G. Alberro, A. Almela, G. Amico, L. H. Arnaldi , et al. (104 additional authors not shown)

    Abstract: A prototype version of the Q & U bolometric interferometer for cosmology (QUBIC) underwent a campaign of testing in the laboratory at Astroparticle Physics and Cosmology laboratory in Paris (APC). The detection chain is currently made of 256 NbSi transition edge sensors (TES) cooled to 320 mK. The readout system is a 128:1 time domain multiplexing scheme based on 128 SQUIDs cooled at 1 K that are… ▽ More

    Submitted 20 October, 2021; v1 submitted 17 January, 2021; originally announced January 2021.

    Comments: Accepted for publication in JCAP

  2. arXiv:2011.02213  [pdf, other

    astro-ph.IM astro-ph.CO

    QUBIC I: Overview and ScienceProgram

    Authors: J. -Ch. Hamilton, L. Mousset, E. S. Battistelli, M. -A. Bigot-Sazy, P. Chanial, R. Charlassier, G. D'Alessandro, P. de Bernardis, M. De Petris, M. M. Gamboa Lerena, L. Grandsire, S. Lau, S. Marnieros, S. Masi, A. Mennella, C. O'Sullivan, M. Piat, G. Riccardi, C. Scóccola, M. Stolpovskiy, A. Tartari, S. A. Torchinsky, F. Voisin, M. Zannoni, P. Ade , et al. (105 additional authors not shown)

    Abstract: The Q $\&$ U Bolometric Interferometer for Cosmology (QUBIC) is a novel kind of polarimeter optimized for the measurement of the B-mode polarization of the Cosmic Microwave Background (CMB), which is one of the major challenges of observational cosmology. The signal is expected to be of the order of a few tens of nK, prone to instrumental systematic effects and polluted by various astrophysical fo… ▽ More

    Submitted 26 August, 2021; v1 submitted 4 November, 2020; originally announced November 2020.

    Comments: 34 pages, 16 figures, accepted for publication by JCAP. Overview paper for a series of 8 QUBIC articles special JCAP edition dedicated to QUBIC

  3. QUBIC II: Spectro-Polarimetry with Bolometric Interferometry

    Authors: L. Mousset, M. M. Gamboa Lerena, E. S. Battistelli, P. de Bernardis, P. Chanial, G. D'Alessandro, G. Dashyan, M. De Petris, L. Grandsire, J. -Ch. Hamilton, F. Incardona, S. Landau, S. Marnieros, S. Masi, A. Mennella, C. O'Sullivan, M. Piat, G. Ricciardi, C. G. Scóccola, M. Stolpovskiy, A. Tartari, J. -P. Thermeau, S. A. Torchinsky, F. Voisin, M. Zannoni , et al. (106 additional authors not shown)

    Abstract: Bolometric interferometry is a novel technique that has the ability to perform spectral imaging. A bolometric interferometer observes the sky in a wide frequency band and can reconstruct sky maps in several sub-bands within the physical band in post-processing of the data. This provides a powerful spectral method to discriminate between the cosmic microwave background (CMB) and astrophysical foreg… ▽ More

    Submitted 28 March, 2022; v1 submitted 28 October, 2020; originally announced October 2020.

    Comments: 27 pages, 18 figures. Accepted by JCAP on July 6, 2021. Second paper of series of 8 in a special JCAP edition on QUBIC

  4. arXiv:2008.12721  [pdf, other

    astro-ph.IM physics.ins-det

    QUBIC VII: The feedhorn-switch system of the technological demonstrator

    Authors: F. Cavaliere, A. Mennella, M. Zannoni, P. Battaglia, E. S. Battistelli, D. Burke, G. D'Alessandro, P. de Bernardis, M. De Petris, C. Franceschet, L. Grandsire, J. -Ch. Hamilton, B. Maffei, E. Manzan, S. Marnieros, S. Masi, C. O'Sullivan, A. Passerini, F. Pezzotta, M. Piat, A. Tartari, S. A. Torchinsky, D. Viganò, F. Voisin, P. Ade , et al. (106 additional authors not shown)

    Abstract: We present the design, manufacturing and performance of the horn-switch system developed for the technological demonstrator of QUBIC (the $Q$\&$U$ Bolometric Interferometer for Cosmology). This system is constituted of 64 back-to-back dual-band (150\,GHz and 220\,GHz) corrugated feed-horns interspersed with mechanical switches used to select desired baselines during the instrument self-calibration… ▽ More

    Submitted 1 April, 2022; v1 submitted 28 August, 2020; originally announced August 2020.

    Comments: 30 pages, 28 figures. Accepted for submission to JCAP

  5. arXiv:2008.10667  [pdf, other

    astro-ph.IM astro-ph.CO

    QUBIC VI: cryogenic half wave plate rotator, design and performances

    Authors: G. D'Alessandro, L. Mele, F. Columbro, G. Amico, E. S. Battistelli, P. de Bernardis, A. Coppolecchia, M. De Petris, L. Grandsire, J. -Ch. Hamilton, L. Lamagna, S. Marnieros, S. Masi, A. Mennella, C. O'Sullivan, A. Paiella, F. Piacentini, M. Piat, G. Pisano, G. Presta, A. Tartari, S. A. Torchinsky, F. Voisin, M. Zannoni, P. Ade , et al. (104 additional authors not shown)

    Abstract: Inflation Gravity Waves B-Modes polarization detection is the ultimate goal of modern large angular scale cosmic microwave background (CMB) experiments around the world. A big effort is undergoing with the deployment of many ground-based, balloon-borne and satellite experiments using different methods to separate this faint polarized component from the incoming radiation. One of the largely used t… ▽ More

    Submitted 19 November, 2020; v1 submitted 24 August, 2020; originally announced August 2020.

    Comments: Part of a series of 8 papers on QUBIC to be submitted to a special issue of JCAP

  6. arXiv:2008.10659  [pdf, other

    astro-ph.IM physics.ins-det

    QUBIC V: Cryogenic system design and performance

    Authors: S. Masi, E. S. Battistelli, P. de Bernardis, C. Chapron, F. Columbro, G. D'Alessandro, M. De Petris, L. Grandsire, J. -Ch. Hamilton, S. Marnieros, L. Mele, A. May, A. Mennella, C. O'Sullivan, A. Paiella, F. Piacentini, M. Piat, L. Piccirillo, G. Presta, A. Schillaci, A. Tartari, J. -P. Thermeau, S. A. Torchinsky, F. Voisin, M. Zannoni , et al. (104 additional authors not shown)

    Abstract: Current experiments aimed at measuring the polarization of the Cosmic Microwave Background (CMB) use cryogenic detector arrays and cold optical systems to boost the map** speed of the sky survey. For these reasons, large volume cryogenic systems, with large optical windows, working continuously for years, are needed. Here we report on the cryogenic system of the QUBIC (Q and U Bolometric Interfe… ▽ More

    Submitted 25 August, 2021; v1 submitted 24 August, 2020; originally announced August 2020.

    Comments: This is one of a series of papers on the QUBIC experiment status - This version of the paper matches the one accepted for publication on Journal of Cosmology and Astroparticle Physics

  7. arXiv:2008.10119  [pdf, other

    astro-ph.IM astro-ph.CO

    QUBIC VIII: Optical design and performance

    Authors: C. O'Sullivan, M. De Petris, G. Amico, E. S. Battistelli, D. Burke, D. Buzi, C. Chapron, L. Conversi, G. D'Alessandro, P. de Bernardis, M. De Leo, D. Gayer, L. Grandsire, J. -Ch. Hamilton, S. Marnieros, S. Masi, A. Mattei, A. Mennella, L. Mousset, J. D. Murphy, A. Pelosi, M. Perciballi, M. Piat, S. Scully, A. Tartari , et al. (104 additional authors not shown)

    Abstract: The Q and U Bolometric Interferometer for Cosmology (QUBIC) is a ground-based experiment that aims to detect B-mode polarisation anisotropies in the CMB at angular scales around the l=100 recombination peak. Systematic errors make ground-based observations of B modes at millimetre wavelengths very challenging and QUBIC mitigates these problems in a somewhat complementary way to other existing or p… ▽ More

    Submitted 25 August, 2021; v1 submitted 23 August, 2020; originally announced August 2020.

    Comments: Part of a series of 8 papers on QUBIC to be published in a special issue of JCAP. Accepted for publication

  8. QUBIC III: Laboratory Characterization

    Authors: S. A. Torchinsky, J. -Ch. Hamilton, M. Piat, E. S. Battistelli, C. Chapron, G. D'Alessandro, P. de Bernardis, M. De Petris, M. M. Gamboa Lerena, M. González, L. Grandsire, S. Masi, S. Marnieros, A. Mennella, L. Mousset, J. D. Murphy, D. Prêle, G. Stankowiak, C. O'Sullivan, A. Tartari, J. -P. Thermeau, F. Voisin, M. Zannoni, P. Ade, J. G. Alberro , et al. (103 additional authors not shown)

    Abstract: A prototype version of the Q & U Bolometric Interferometer for Cosmology (QUBIC) underwent a campaign of testing in the laboratory at Astroparticle Physics and Cosmology in Paris. We report the results of this Technological Demonstrator which successfully shows the feasibility of the principle of Bolometric Interferometry. Characterization of QUBIC includes the measurement of the synthesized beam,… ▽ More

    Submitted 15 March, 2022; v1 submitted 23 August, 2020; originally announced August 2020.

    Comments: Part of a series of 8 papers on QUBIC accepted by JCAP for a special issue: https://iopscience.iop.org/journal/1475-7516/page/QUBIC_status_and_forecast

  9. arXiv:2001.10272  [pdf, other

    astro-ph.IM astro-ph.CO

    QUBIC: the Q & U Bolometric Interferometer for Cosmology

    Authors: E. S. Battistelli, P. Ade, J. G. Alberro, A. Almela, G. Amico, L. H. Arnaldi, D. Auguste, J. Aumont, S. Azzoni, S. Banfi, P. Battaglia, A. Baù, B. Bèlier, D. Bennett, L. Bergè, J. -Ph. Bernard, M. Bersanelli, M. -A. Bigot-Sazy, N. Bleurvacq, J. Bonaparte, J. Bonis, A. Bottani, E. Bunn, D. Burke, D. Buzi , et al. (114 additional authors not shown)

    Abstract: The Q & U Bolometric Interferometer for Cosmology, QUBIC, is an innovative experiment designed to measure the polarization of the Cosmic Microwave Background and in particular the signature left therein by the inflationary expansion of the Universe. The expected signal is extremely faint, thus extreme sensitivity and systematic control are necessary in order to attempt this measurement. QUBIC addr… ▽ More

    Submitted 28 January, 2020; originally announced January 2020.

    Comments: Accepted for publication in the Journal of Low Temperature Physics

  10. arXiv:1911.12418  [pdf, other

    astro-ph.IM astro-ph.CO

    QUBIC: using NbSi TESs with a bolometric interferometer to characterize the polarisation of the CMB

    Authors: M. Piat, B. Bélier, L. Bergé, N. Bleurvacq, C. Chapron, S. Dheilly, L. Dumoulin, M. González, L. Grandsire, J. -Ch. Hamilton, S. Henrot-Versillé, D. T. Hoang, S. Marnieros, W. Marty, L. Montier, E. Olivieri, C. Oriol, C. Perbost, D. Prêle, D. Rambaud, M. Salatino, G. Stankowiak, J. -P. Thermeau, S. Torchinsky, F. Voisin , et al. (113 additional authors not shown)

    Abstract: QUBIC (Q \& U Bolometric Interferometer for Cosmology) is an international ground-based experiment dedicated in the measurement of the polarized fluctuations of the Cosmic Microwave Background (CMB). It is based on bolometric interferometry, an original detection technique which combine the immunity to systematic effects of an interferometer with the sensitivity of low temperature incoherent detec… ▽ More

    Submitted 9 December, 2019; v1 submitted 27 November, 2019; originally announced November 2019.

    Comments: Conference proceedings submitted to the Journal of Low Temperature Physics for LTD18

  11. arXiv:1811.02296  [pdf, other

    astro-ph.IM physics.ins-det

    Thermal architecture for the QUBIC cryogenic receiver

    Authors: A. J. May, C. Chapron, G. Coppi, G. D'Alessandro, P. de Bernardis, S. Masi, S. Melhuish, M. Piat, L. Piccirillo, A. Schillaci, J. -P. Thermeau, P. Ade, G. Amico, D. Auguste, J. Aumont, S. Banfi, G. Barbara, P. Battaglia, E. Battistelli, A. Bau, B. Belier, D. Bennett, L. Berge, J. -Ph. Bernard, M. Bersanelli , et al. (105 additional authors not shown)

    Abstract: QUBIC, the QU Bolometric Interferometer for Cosmology, is a novel forthcoming instrument to measure the B-mode polarization anisotropy of the Cosmic Microwave Background. The detection of the B-mode signal will be extremely challenging; QUBIC has been designed to address this with a novel approach, namely bolometric interferometry. The receiver cryostat is exceptionally large and cools complex opt… ▽ More

    Submitted 6 November, 2018; originally announced November 2018.

    Journal ref: Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy IX. Vol. 10708. International Society for Optics and Photonics, 2018

  12. arXiv:1801.03730  [pdf, other

    astro-ph.IM

    QUBIC - The Q&U Bolometric Interferometer for Cosmology - A novel way to look at the polarized Cosmic Microwave Background

    Authors: A. Mennella, P. A. R. Ade, J. Aumont, S. Banfi, P. Battaglia, E. S. Battistelli, A. Baù, B. Bélier, D. Bennett, L. Bergé, J. Ph. Bernard, M. Bersanelli, M. A. Bigot-Sazy, N. Bleurvacq, G. Bordier, J. Brossard, E. F. Bunn, D. P. Burke, D. Buzi, A. Buzzelli, D. Cammilleri, F. Cavaliere, P. Chanial, C. Chapron, F. Columbro , et al. (83 additional authors not shown)

    Abstract: In this paper we describe QUBIC, an experiment that takes up the challenge posed by the detection of primordial gravitational waves with a novel approach, that combines the sensitivity of state-of-the art bolometric detectors with the systematic effects control typical of interferometers. The so-called "self-calibration" is a technique deeply rooted in the interferometric nature of the instrument… ▽ More

    Submitted 11 January, 2018; originally announced January 2018.

    Comments: Presented at the EPS Conference on High Energy Physics, Venice (Italy), 5-12 July 2017 Accepted for publication in conference proceedings

  13. arXiv:1609.04372  [pdf, other

    astro-ph.IM astro-ph.CO

    QUBIC Technical Design Report

    Authors: J. Aumont, S. Banfi, P. Battaglia, E. S. Battistelli, A. Baù, B. Bélier, D. Bennett, L. Bergé, J. Ph. Bernard, M. Bersanelli, M. A. Bigot-Sazy, N. Bleurvacq, G. Bordier, J. Brossard, E. F. Bunn, D. Buzi, A. Buzzelli, D. Cammilleri, F. Cavaliere, P. Chanial, C. Chapron, G. Coppi, A. Coppolecchia, F. Couchot, R. D'Agostino , et al. (74 additional authors not shown)

    Abstract: QUBIC is an instrument aiming at measuring the B mode polarisation anisotropies at medium scales angular scales (30-200 multipoles). The search for the primordial CMB B-mode polarization signal is challenging, because of many difficulties: smallness of the expected signal, instrumental systematics that could possibly induce polarization leakage from the large E signal into B, brighter than anticip… ▽ More

    Submitted 11 May, 2017; v1 submitted 14 September, 2016; originally announced September 2016.

    Comments: 139 pages ; high resolution version can be found on the qubic website (http://qubic.in2p3.fr/QUBIC/Home.html) minor changes : update author list & affiliations ; correct title

  14. arXiv:1511.03006  [pdf, ps, other

    astro-ph.CO astro-ph.IM

    HI intensity map** with FAST

    Authors: Marie-Anne Bigot-Sazy, Yin-Zhe Ma, Richard A. Battye, Ian W. A. Browne, Tianyue Chen, Clive Dickinson, Stuart Harper, Bruno Maffei, Lucas C. Olivari, Peter N. Wilkinson

    Abstract: We discuss the detectability of large-scale HI intensity fluctuations using the FAST telescope. We present forecasts for the accuracy of measuring the Baryonic Acoustic Oscillations and constraining the properties of dark energy. The FAST $19$-beam L-band receivers ($1.05$--$1.45$ GHz) can provide constraints on the matter power spectrum and dark energy equation of state parameters ($w_{0},w_{a}$)… ▽ More

    Submitted 10 November, 2015; originally announced November 2015.

    Comments: 7 pages, 3 figures, submitted to "Frontiers in Radio Astronomy and FAST Early Sciences Symposium 2015" conference proceeding

    Journal ref: 2016, Astronomical Society of the Pacific Conference Series, 502, 41

  15. arXiv:1507.04561  [pdf, other

    astro-ph.CO astro-ph.IM

    Simulations for single-dish intensity map** experiments

    Authors: M. -A. Bigot-Sazy, C. Dickinson, R. A. Battye, I. W. A. Browne, Y. -Z. Ma, B. Maffei, F. Noviello, M. Remazeilles, P. N. Wilkinson

    Abstract: HI intensity map** is an emerging tool to probe dark energy. Observations of the redshifted HI signal will be contaminated by instrumental noise, atmospheric and Galactic foregrounds. The latter is expected to be four orders of magnitude brighter than the HI emission we wish to detect. We present a simulation of single-dish observations including an instrumental noise model with 1/f and white no… ▽ More

    Submitted 16 July, 2015; originally announced July 2015.

    Comments: 14 pages, 12 figures. Submitted to MNRAS

  16. arXiv:1411.3628  [pdf, other

    astro-ph.IM astro-ph.CO astro-ph.GA

    An improved source-subtracted and destriped 408 MHz all-sky map

    Authors: M. Remazeilles, C. Dickinson, A. J. Banday, M. -A. Bigot-Sazy, T. Ghosh

    Abstract: The all-sky 408 MHz map of Haslam et al. is one the most important total-power radio surveys. It has been widely used to study diffuse synchrotron radiation from our Galaxy and as a template to remove foregrounds in cosmic microwave background data. However, there are a number of issues associated with it that must be dealt with, including large-scale striations and contamination from extragalacti… ▽ More

    Submitted 10 June, 2015; v1 submitted 17 October, 2014; originally announced November 2014.

    Comments: 18 pages, 16 figures. Updated to match version accepted by MNRAS

  17. arXiv:1307.5701  [pdf, other

    astro-ph.IM astro-ph.CO

    Latest Progress on the QUBIC Instrument

    Authors: A. Ghribi, J. Aumont, E. S. Battistelli, A. Bau, L. Bergé, J-Ph. Bernard, M. Bersanelli, M-A. Bigot-Sazy, G. Bordier, E. T. Bunn, F. Cavaliere, P. Chanial, A. Coppolecchia, T. Decourcelle, P. De Bernardis, M. De Petris, A-A. Drilien, L. Dumoulin, M. C. Falvella, A. Gault, M. Gervasi, M. Giard, M. Gradziel, L. Grandsire, D. Gayer , et al. (38 additional authors not shown)

    Abstract: QUBIC is a unique instrument that crosses the barriers between classical imaging architectures and interferometry taking advantage from both for high sensitivity and systematics mitigation. The scientific target is the detection of the primordial gravitational waves imprint on the Cosmic Microwave Background which are the proof of inflation, holy grail of modern cosmology. In this paper, we show t… ▽ More

    Submitted 12 November, 2013; v1 submitted 22 July, 2013; originally announced July 2013.

    Comments: 6 pages, 2 figures, conference LTD15

  18. arXiv:1209.4905  [pdf, other

    astro-ph.IM astro-ph.CO

    Self-calibration: an efficient method to control systematic effects in bolometric interferometry

    Authors: M. -A. Bigot-Sazy, R. Charlassier, J. -Ch. Hamilton, J. Kaplan, G. Zahariade

    Abstract: Context. The QUBIC collaboration is building a bolometric interferometer dedicated to the detection of B-mode polarization fluctuations in the Cosmic Microwave Background. Aims. We introduce a self-calibration procedure related to those used in radio-interferometry to control a large range of instrumental systematic errors in polarization-sensitive instruments. Methods. This procedure takes advant… ▽ More

    Submitted 21 September, 2012; originally announced September 2012.

    Comments: 11 pages, 4 figures