-
Heterodyne dispersive cavity ring-down spectroscopy exploiting eigenmode frequencies for high-fidelity measurements
Authors:
Agata Cygan,
Szymon Wójtewicz,
Hubert Jóźwiak,
Grzegorz Kowzan,
Nikodem Stolarczyk,
Katarzyna Bielska,
Piotr Wcisło,
Roman Ciuryło,
Daniel Lisak
Abstract:
Measuring low light absorption with combined uncertainty < 1 permille is crucial in a wide range of applications. Popular cavity ring-down spectroscopy can provide ultra-high precision, below 0.01 permille, but its accuracy is strongly dependent on the measurement capabilities of the detection system and typically is about 10 permille. Here, we exploit the optical frequency information carried by…
▽ More
Measuring low light absorption with combined uncertainty < 1 permille is crucial in a wide range of applications. Popular cavity ring-down spectroscopy can provide ultra-high precision, below 0.01 permille, but its accuracy is strongly dependent on the measurement capabilities of the detection system and typically is about 10 permille. Here, we exploit the optical frequency information carried by the ring-down cavity electromagnetic field, not explored in conventional CRDS, for high-fidelity spectroscopy. Instead of measuring only the decaying light intensity, we perform heterodyne detection of ring-downs followed by Fourier analysis to provide exact frequencies of optical cavity modes and a dispersive spectrum of a gas sample from them. This approach is insensitive to inaccuracies in light intensity measurements and eliminates the problem of detector band nonlinearity, the main cause of measurement error in traditional CRDS. Using the CO and HD line intensities as examples, we demonstrate the sub-permille accuracy of our method, confirmed by the best ab initio results, and the long-term repeatability of our dispersion measurements at 10^(-4) level. Such results have not been achieved in optical spectroscopy before. The high accuracy of the presented method indicates its potential in atmospheric studies, isotope ratio metrology, thermometry, and the establishment of primary gas standards.
△ Less
Submitted 4 March, 2024;
originally announced March 2024.
-
Sub-promille measurements and calculations of CO (3--0) overtone line intensities
Authors:
K. Bielska,
A. A. Kyuberis,
Z. D. Reed,
Gang Li,
A. Cygan,
R. Ciuryło,
D. Lisak,
E. M. Adkins,
L. Lodi,
J. T. Hodges,
V. Ebert,
N. F. Zobov,
J. Tennyson,
O. L. Polyansky
Abstract:
Intensities of lines in the near-infrared second overtone band (3--0) of $^{12}$C$^{16}$O are measured and calculated to an unprecedented degree of precision and accuracy. Agreement between theory and experiment to better than 1 $\permil$ is demonstrated by results from two laboratories involving two independent absorption- and dispersion-based cavity-enhanced techniques. Similarly, independent Fo…
▽ More
Intensities of lines in the near-infrared second overtone band (3--0) of $^{12}$C$^{16}$O are measured and calculated to an unprecedented degree of precision and accuracy. Agreement between theory and experiment to better than 1 $\permil$ is demonstrated by results from two laboratories involving two independent absorption- and dispersion-based cavity-enhanced techniques. Similarly, independent Fourier transform spectroscopy measurements of stronger lines in this band yield mutual agreement and consistency with theory at the 1 $\permil$ level. This set of highly accurate intensities can provide an intrinsic reference for reducing biases in future measurements of spectroscopic peak areas.
△ Less
Submitted 27 July, 2022;
originally announced July 2022.
-
Absolute frequency determination of molecular transition in the Doppler regime at kHz level of accuracy
Authors:
K. Bielska,
S. Wojtewicz,
P. Morzynski,
P. Ablewski,
A. Cygan,
M. Bober,
M. Zawada,
R. Ciurylo,
P. Maslowski,
D. Lisak
Abstract:
We present absolute frequency measurement of the unperturbed P7 P7 O$_2$ B-band transition with relative standard uncertainty of $2\times10^{-11}$. We reached the level of accuracy typical for Doppler-free techniques, with Doppler-limited spectroscopy. The Doppler-limited shapes of the P7 P7 spectral line were measured with a frequency-stabilized cavity ring-down spectrometer referenced to an…
▽ More
We present absolute frequency measurement of the unperturbed P7 P7 O$_2$ B-band transition with relative standard uncertainty of $2\times10^{-11}$. We reached the level of accuracy typical for Doppler-free techniques, with Doppler-limited spectroscopy. The Doppler-limited shapes of the P7 P7 spectral line were measured with a frequency-stabilized cavity ring-down spectrometer referenced to an $^{88}$Sr optical atomic clock by an optical frequency comb.
△ Less
Submitted 16 August, 2017; v1 submitted 18 May, 2017;
originally announced May 2017.
-
High accuracy CO$_2$ line intensities determined from theory and experiment
Authors:
Oleg L. Polyansky,
Katarzyna Bielska,
Mélanie Ghysels,
Lorenzo Lodi,
Nikolai F. Zobov,
Joseph T. Hodges,
Jonathan Tennyson
Abstract:
Atmospheric CO$_2$ concentrations are being closely monitored by remote sensing experiments which rely on knowing line intensities with an uncertainty of 0.5\%\ or better. Most available laboratory measurements have uncertainties much larger than this. We report a joint experimental and theoretical study providing rotation-vibration line intensities with the required accuracy. The {\it ab initio}…
▽ More
Atmospheric CO$_2$ concentrations are being closely monitored by remote sensing experiments which rely on knowing line intensities with an uncertainty of 0.5\%\ or better. Most available laboratory measurements have uncertainties much larger than this. We report a joint experimental and theoretical study providing rotation-vibration line intensities with the required accuracy. The {\it ab initio} calculations are extendible to all atmospherically important bands of CO$_2$ and to its isotologues. As such they will form the basis for detailed CO$_2$ spectroscopic line lists for future studies.
△ Less
Submitted 17 October, 2015;
originally announced October 2015.
-
Strontium optical lattice clocks for practical realization of the metre and secondary representation of the second
Authors:
M. Bober,
P. Morzyński,
A. Cygan,
D. Lisak,
P. Masłowski,
M. Prymaczek,
P. Wcisło,
P. Ablewski,
M. Piwiński,
S. Wójtewicz,
K. Bielska,
D. Bartoszek-Bober,
R. Trawiński,
M. Zawada,
R. Ciuryło,
J. Zachorowski,
M. Piotrowski,
W. Gawlik,
F. Ozimek,
C. Radzewicz
Abstract:
We present a system of two independent strontium optical lattice standards probed with a single shared ultra-narrow laser. The absolute frequency of the clocks can be verified by the use of Er:fiber optical frequency comb with the GPS-disciplined Rb frequency standard. We report hertz-level spectroscopy of the clock line and measurements of frequency stability of the two strontium optical lattice…
▽ More
We present a system of two independent strontium optical lattice standards probed with a single shared ultra-narrow laser. The absolute frequency of the clocks can be verified by the use of Er:fiber optical frequency comb with the GPS-disciplined Rb frequency standard. We report hertz-level spectroscopy of the clock line and measurements of frequency stability of the two strontium optical lattice clocks.
△ Less
Submitted 15 June, 2015;
originally announced June 2015.
-
Buffer gas induced collision shift for the $^{88}$Sr $\bf{^1S_0-^3P_1}$ clock transition
Authors:
Nobuyasu Shiga,
Ying Li,
Hiroyuki Ito,
Shigeo Nagano,
Tetsuya Ido,
Katarzyna Bielska,
Ryszard S. Trawiński,
Roman Ciuryło
Abstract:
Precision saturation spectroscopy of the $^{88}{\rm Sr} ^1S_0-^3P_1$ is performed in a vapor cell filled with various rare gas including He, Ne, Ar, and Xe. By continuously calibrating the absolute frequency of the probe laser, buffer gas induced collision shifts of $\sim $kHz are detected with gas pressure of 1-20 mTorr. Helium gave the largest fractional shift of…
▽ More
Precision saturation spectroscopy of the $^{88}{\rm Sr} ^1S_0-^3P_1$ is performed in a vapor cell filled with various rare gas including He, Ne, Ar, and Xe. By continuously calibrating the absolute frequency of the probe laser, buffer gas induced collision shifts of $\sim $kHz are detected with gas pressure of 1-20 mTorr. Helium gave the largest fractional shift of $1.6 \times 10^{-9} {\rm Torr}^{-1}$. Comparing with a simple impact calculation and a Doppler-limited experiment of Holtgrave and Wolf [Phys. Rev. A {\bf 72}, 012711 (2005)], our results show larger broadening and smaller shifting coefficient, indicating effective atomic loss due to velocity changing collisions. The applicability of the result to the $^1S_0-^3P_0$ optical lattice clock transition is also discussed.
△ Less
Submitted 5 July, 2009;
originally announced July 2009.