Towards Super-Resolution CEST MRI for Visualization of Small Structures
Authors:
Lukas Folle,
Katharian Tkotz,
Fasil Gadjimuradov,
Lorenz Kapsner,
Moritz Fabian,
Sebastian Bickelhaupt,
David Simon,
Arnd Kleyer,
Gerhard Krönke,
Moritz Zaiß,
Armin Nagel,
Andreas Maier
Abstract:
The onset of rheumatic diseases such as rheumatoid arthritis is typically subclinical, which results in challenging early detection of the disease. However, characteristic changes in the anatomy can be detected using imaging techniques such as MRI or CT. Modern imaging techniques such as chemical exchange saturation transfer (CEST) MRI drive the hope to improve early detection even further through…
▽ More
The onset of rheumatic diseases such as rheumatoid arthritis is typically subclinical, which results in challenging early detection of the disease. However, characteristic changes in the anatomy can be detected using imaging techniques such as MRI or CT. Modern imaging techniques such as chemical exchange saturation transfer (CEST) MRI drive the hope to improve early detection even further through the imaging of metabolites in the body. To image small structures in the joints of patients, typically one of the first regions where changes due to the disease occur, a high resolution for the CEST MR imaging is necessary. Currently, however, CEST MR suffers from an inherently low resolution due to the underlying physical constraints of the acquisition. In this work we compared established up-sampling techniques to neural network-based super-resolution approaches. We could show, that neural networks are able to learn the map** from low-resolution to high-resolution unsaturated CEST images considerably better than present methods. On the test set a PSNR of 32.29dB (+10%), a NRMSE of 0.14 (+28%), and a SSIM of 0.85 (+15%) could be achieved using a ResNet neural network, improving the baseline considerably. This work paves the way for the prospective investigation of neural networks for super-resolution CEST MRI and, followingly, might lead to a earlier detection of the onset of rheumatic diseases.
△ Less
Submitted 3 December, 2021;
originally announced December 2021.
-
Design of a non-linear human breast diffusion coil
Authors:
Feng Jia,
Sebastian Littin,
Philipp Amrein,
Stefan Kroboth,
Huijun Yu,
Arthur W. Magill,
Tristan Kuder,
Sebastian Bickelhaupt,
Frederik Laun,
Mark E. Ladd,
Maxim Zaitsev
Abstract:
Diffusion-weighted imaging (DWI) in the female breast is a magnetic resonance imaging (MRI) technique, which may potentially replace or effectively complement both x-ray mammography and contrast-enhanced MR mammography. To further improve specificity of DWI in the breast, stronger and faster diffusion weighting is advantageous. With the target application in mind, the gradient coil is designed on…
▽ More
Diffusion-weighted imaging (DWI) in the female breast is a magnetic resonance imaging (MRI) technique, which may potentially replace or effectively complement both x-ray mammography and contrast-enhanced MR mammography. To further improve specificity of DWI in the breast, stronger and faster diffusion weighting is advantageous. With the target application in mind, the gradient coil is designed on an irregularly shaped semi-open current-carrying surface. Due to the coil former closely fitting the non-spherical target region, non-linear encoding fields become particularly advantageous for achieving locally exceptionally high gradient strengths. As the breast tissue has a predominantly isotropic cellular microstructure, the direction of the diffusion-weighting gradient may be allowed to vary within the target volume. However, due to the quadratic dependency of the b-factor on the gradient strength, variation of the gradient magnitude needs to be carefully controlled.
To achieve the above design goals the corresponding multi-objective optimization problem is reformulated as a constrained optimization, allowing for flexible and precise control of the coil properties. A novel constraint is proposed limiting the gradient magnitude variation within every slice while allowing for variations both the direction of the gradient within the slice and the magnitude across the slices. The above innovations enable the design of a unilateral coil for diffusion weighting in the female breast with the local gradient strengths exceeding 1~T/m with highly homogeneous diffusion weighting for imaging in the coronal slice orientation.
△ Less
Submitted 23 December, 2020;
originally announced December 2020.
-
Retina U-Net: Embarrassingly Simple Exploitation of Segmentation Supervision for Medical Object Detection
Authors:
Paul F. Jaeger,
Simon A. A. Kohl,
Sebastian Bickelhaupt,
Fabian Isensee,
Tristan Anselm Kuder,
Heinz-Peter Schlemmer,
Klaus H. Maier-Hein
Abstract:
The task of localizing and categorizing objects in medical images often remains formulated as a semantic segmentation problem. This approach, however, only indirectly solves the coarse localization task by predicting pixel-level scores, requiring ad-hoc heuristics when map** back to object-level scores. State-of-the-art object detectors on the other hand, allow for individual object scoring in a…
▽ More
The task of localizing and categorizing objects in medical images often remains formulated as a semantic segmentation problem. This approach, however, only indirectly solves the coarse localization task by predicting pixel-level scores, requiring ad-hoc heuristics when map** back to object-level scores. State-of-the-art object detectors on the other hand, allow for individual object scoring in an end-to-end fashion, while ironically trading in the ability to exploit the full pixel-wise supervision signal. This can be particularly disadvantageous in the setting of medical image analysis, where data sets are notoriously small. In this paper, we propose Retina U-Net, a simple architecture, which naturally fuses the Retina Net one-stage detector with the U-Net architecture widely used for semantic segmentation in medical images. The proposed architecture recaptures discarded supervision signals by complementing object detection with an auxiliary task in the form of semantic segmentation without introducing the additional complexity of previously proposed two-stage detectors. We evaluate the importance of full segmentation supervision on two medical data sets, provide an in-depth analysis on a series of toy experiments and show how the corresponding performance gain grows in the limit of small data sets. Retina U-Net yields strong detection performance only reached by its more complex two-staged counterparts. Our framework including all methods implemented for operation on 2D and 3D images is available at github.com/pfjaeger/medicaldetectiontoolkit.
△ Less
Submitted 21 November, 2018;
originally announced November 2018.
-
Domain Adaptation for Deviating Acquisition Protocols in CNN-based Lesion Classification on Diffusion-Weighted MR Images
Authors:
Jennifer Kamphenkel,
Paul F. Jaeger,
Sebastian Bickelhaupt,
Frederik Bernd Laun,
Wolfgang Lederer,
Heidi Daniel,
Tristan Anselm Kuder,
Stefan Delorme,
Heinz-Peter Schlemmer,
Franziska Koenig,
Klaus H. Maier-Hein
Abstract:
End-to-end deep learning improves breast cancer classification on diffusion-weighted MR images (DWI) using a convolutional neural network (CNN) architecture. A limitation of CNN as opposed to previous model-based approaches is the dependence on specific DWI input channels used during training. However, in the context of large-scale application, methods agnostic towards heterogeneous inputs are des…
▽ More
End-to-end deep learning improves breast cancer classification on diffusion-weighted MR images (DWI) using a convolutional neural network (CNN) architecture. A limitation of CNN as opposed to previous model-based approaches is the dependence on specific DWI input channels used during training. However, in the context of large-scale application, methods agnostic towards heterogeneous inputs are desirable, due to the high deviation of scanning protocols between clinical sites. We propose model-based domain adaptation to overcome input dependencies and avoid re-training of networks at clinical sites by restoring training inputs from altered input channels given during deployment. We demonstrate the method's significant increase in classification performance and superiority over implicit domain adaptation provided by training-schemes operating on model-parameters instead of raw DWI images.
△ Less
Submitted 17 July, 2018;
originally announced July 2018.
-
Revealing Hidden Potentials of the q-Space Signal in Breast Cancer
Authors:
Paul Jaeger,
Sebastian Bickelhaupt,
Frederik Bernd Laun,
Wolfgang Lederer,
Daniel Heidi,
Tristan Anselm Kuder,
Daniel Paech,
David Bonekamp,
Alexander Radbruch,
Stefan Delorme,
Heinz-Peter Schlemmer,
Franziska Steudle,
Klaus H. Maier-Hein
Abstract:
Mammography screening for early detection of breast lesions currently suffers from high amounts of false positive findings, which result in unnecessary invasive biopsies. Diffusion-weighted MR images (DWI) can help to reduce many of these false-positive findings prior to biopsy. Current approaches estimate tissue properties by means of quantitative parameters taken from generative, biophysical mod…
▽ More
Mammography screening for early detection of breast lesions currently suffers from high amounts of false positive findings, which result in unnecessary invasive biopsies. Diffusion-weighted MR images (DWI) can help to reduce many of these false-positive findings prior to biopsy. Current approaches estimate tissue properties by means of quantitative parameters taken from generative, biophysical models fit to the q-space encoded signal under certain assumptions regarding noise and spatial homogeneity. This process is prone to fitting instability and partial information loss due to model simplicity. We reveal unexplored potentials of the signal by integrating all data processing components into a convolutional neural network (CNN) architecture that is designed to propagate clinical target information down to the raw input images. This approach enables simultaneous and target-specific optimization of image normalization, signal exploitation, global representation learning and classification. Using a multicentric data set of 222 patients, we demonstrate that our approach significantly improves clinical decision making with respect to the current state of the art.
△ Less
Submitted 22 May, 2017; v1 submitted 27 February, 2017;
originally announced February 2017.