-
Quantitative Evaluation of Microstrip, Dipole, and L/C Loop pTx Arrays for UHF MR Imaging
Authors:
Debolina De,
Aditya A. Bhosale,
Dr. Xiaoliang Zhang
Abstract:
Ultra-high field MRI (7T+) unlocks a new era of brain research with superior resolution and signal-to-noise. Capturing intricate neural activity and detailed soft tissue pathology, this technology, coupled with advanced RF coil arrays, holds immense potential for clinical diagnosis and discovery. For high-field body imaging, microstrip resonators and dipole arrays for high-field body imaging show…
▽ More
Ultra-high field MRI (7T+) unlocks a new era of brain research with superior resolution and signal-to-noise. Capturing intricate neural activity and detailed soft tissue pathology, this technology, coupled with advanced RF coil arrays, holds immense potential for clinical diagnosis and discovery. For high-field body imaging, microstrip resonators and dipole arrays for high-field body imaging show promise due to high-frequency operation and improved decoupling. Microstrip arrays excel in compactness, reduced radiation loss, and customizable lengths. Dipole arrays excel in deeper body penetration. Shorter wavelengths at ultrahigh fields can cause image inhomogeneity and elevated SAR. Multichannel transmit arrays address these issues. This research compares three common array types (L/C loop, microstrip, dipole) using CST Studio simulations to evaluate electric/magnetic fields and decoupling. This can guide RF array selection for ultrahigh field MRI.
△ Less
Submitted 27 April, 2024;
originally announced June 2024.
-
Navigating the Docker Ecosystem: A Comprehensive Taxonomy and Survey
Authors:
Prathamesh Muzumdar,
Amol Bhosale,
Ganga Prasad Basyal,
George Kurian
Abstract:
The cloud computing landscape is rapidly expanding and growing in complexity. It has witnessed the emergence of Cloud Computing as a widely adopted model for efficiently processing large volumes of data by harnessing clusters of commodity computers. This evolution enables the handling of massive data through on-demand services, relying on numerous microservices with diverse dependencies. The techn…
▽ More
The cloud computing landscape is rapidly expanding and growing in complexity. It has witnessed the emergence of Cloud Computing as a widely adopted model for efficiently processing large volumes of data by harnessing clusters of commodity computers. This evolution enables the handling of massive data through on-demand services, relying on numerous microservices with diverse dependencies. The technology of containers ensures secure storage, allowing for largescale data processing with high scalability and portability. Container technology, particularly exemplified by Docker in the last decade, plays a pivotal role in this scenario. It empowers microservices to process data swiftly, enabling developers to dynamically scale these services in real-time. This paper initiates by establishing a comprehensive taxonomy for delineating container architecture. Focusing specifically on Docker containers, we scrutinize various existing container related literature. Through this taxonomy and survey, we not only discern similarities and disparities in the architectural approaches of Docker container technology but also pinpoint areas necessitating further research.
△ Less
Submitted 3 January, 2024;
originally announced March 2024.
-
Multimodal surface coils for low-field MR imaging
Authors:
Yunkun Zhao,
Aditya A Bhosale,
Xiaoliang Zhang
Abstract:
Leveraging the potential of low-field Magnetic Resonance Imaging (MRI), our study introduces the multimodal surface RF coil, a design tailored to overcome the limitations of conventional coils in this context. The inherent challenges of low-field MRI, notably suboptimal signal-to-noise ratio (SNR) and the need for specialized RF coils, are effectively addressed by our novel design. The multimodal…
▽ More
Leveraging the potential of low-field Magnetic Resonance Imaging (MRI), our study introduces the multimodal surface RF coil, a design tailored to overcome the limitations of conventional coils in this context. The inherent challenges of low-field MRI, notably suboptimal signal-to-noise ratio (SNR) and the need for specialized RF coils, are effectively addressed by our novel design. The multimodal surface coil is characterized by a unique assembly of resonators, optimized for both B1 efficiency and low-frequency tuning capabilities, essential for low-field applications. This paper provides a thorough investigation of the conceptual framework, design intricacies, and bench test validation of the multimodal surface coil. Through detailed simulations and comparative analyses, we demonstrate its superior performance in terms of B1 field efficiency, outperforming conventional surface coils.
△ Less
Submitted 31 December, 2023;
originally announced January 2024.
-
Electric Field and SAR Reduction in High Impedance RF Arrays by Using High Permittivity Materials for 7T MR Imaging
Authors:
Aditya Ashok Bhosale,
Yunkun Zhao,
Xiaoliang Zhang
Abstract:
Higher frequencies and shorter wavelengths present significant design issues at ultra-high fields, making multi-channel array setup a critical component for ultra-high field MR imaging. The requirement for multi-channel arrays, as well as ongoing efforts to increase the number of channels in an array, are always limited by the major issue known as inter-element coupling. This coupling affects the…
▽ More
Higher frequencies and shorter wavelengths present significant design issues at ultra-high fields, making multi-channel array setup a critical component for ultra-high field MR imaging. The requirement for multi-channel arrays, as well as ongoing efforts to increase the number of channels in an array, are always limited by the major issue known as inter-element coupling. This coupling affects the current and field distribution, noise correlation between channels, and frequency of array elements, lowering imaging quality and performance. To realize the full potential of UHF MRI, we must ensure that the coupling between array elements is kept to a minimum. High-impedance coils allow array systems to completely realize their potential by providing optimal isolation while requiring minimal design modifications. These minor design changes, which demand the use of low capacitance on the conventional loop to induce elevated impedance, result in a significant safety hazard that cannot be overlooked. High electric fields are formed across these low capacitance lumped elements, which may result in higher SAR values in the imaging subject, depositing more power and, ultimately, providing a greater risk of tissue heating-related injury to the human sample. We propose an innovative method of utilizing high-dielectric material to effectively reduce electric fields and SAR values in the imaging sample while preserving the B1 efficiency and inter-element decoupling between the array elements to address this important safety concern with minimal changes to the existing array design comprising high-impedance coils.
△ Less
Submitted 7 December, 2023;
originally announced December 2023.
-
Coupled stack-up volume RF coils for low-field MR imaging
Authors:
Yunkun Zhao,
Aditya A Bhosale,
Xiaoliang Zhang
Abstract:
The advent of low field open magnetic resonance imaging (MRI) systems has greatly expanded the accessibility of MRI technology to meet a wide range of patient needs. However, the inherent challenges of low-field MRI, such as limited signal-to-noise ratios and limited availability of dedicated RF coil, have prompted the need for innovative coil designs that can improve imaging quality and diagnosti…
▽ More
The advent of low field open magnetic resonance imaging (MRI) systems has greatly expanded the accessibility of MRI technology to meet a wide range of patient needs. However, the inherent challenges of low-field MRI, such as limited signal-to-noise ratios and limited availability of dedicated RF coil, have prompted the need for innovative coil designs that can improve imaging quality and diagnostic capabilities. In response to these challenges, we introduce the coupled stack-up volume coil, a novel RF coil design that addresses the shortcomings of conventional birdcage in the context of low field open MRI. The proposed coupled stack-up volume coil design utilizes a unique architecture that optimizes both transmit/receive efficiency and RF field homogeneity and offers the advantage of a simple design and construction, making it a practical and feasible solution for low field MRI applications. This paper presents a comprehensive exploration of the theoretical framework, design considerations, and experimental validation of this innovative coil design. Through rigorous analysis and empirical testing, we demonstrate the superior performance of the coupled stack-up volume coil in achieving improved transmit/receive efficiency and more uniform magnetic field distribution compared to traditional birdcage coils.
△ Less
Submitted 15 November, 2023;
originally announced November 2023.
-
Dual-tuned Coaxial-transmission-line RF coils for Hyperpolarized 13C and Deuterium 2H Metabolic MRS Imaging at Ultrahigh Fields
Authors:
Komlan Payne,
Yunkun Zhao,
Aditya Ashok Bhosale,
Xiaoliang Zhang
Abstract:
$Objective:$ Information on the metabolism of tissues in both healthy and diseased states plays a significant role in the detection and understanding of tumors, neurodegenerative diseases, diabetes, and other metabolic disorders. Hyperpolarized carbon-13 magnetic resonance imaging ($^{13}$C-HPMRI) and deuterium metabolic imaging ($^2…
▽ More
$Objective:$ Information on the metabolism of tissues in both healthy and diseased states plays a significant role in the detection and understanding of tumors, neurodegenerative diseases, diabetes, and other metabolic disorders. Hyperpolarized carbon-13 magnetic resonance imaging ($^{13}$C-HPMRI) and deuterium metabolic imaging ($^2$H-DMI) are two emerging X-nuclei used as practical imaging tools to investigate tissue metabolism. However due to their low gyromagnetic ratios ($γ_{13C}$ = 10.7 MHz/T; $γ_{2H}$ = 6.5 MHz/T) and natural abundance, such method required a sophisticated dual-tuned radiofrequency (RF) coil. $ Methods:$ Here, we report a dual-tuned coaxial transmission line (CTL) RF coil agile for metabolite information operating at 7T with independent tuning capability. The design analysis has demonstrated how both resonant frequencies can be individually controlled by simply varying the constituent of the design parameters. $Results:$ Numerical results have demonstrated a broadband tuning range capability, covering most of the X-nucleus signal, especially the $^{13}$C and $^2$H spectra at 7T. Furthermore, in order to validate the feasibility of the proposed design, both dual-tuned $^1$H/$^{13}$C and $^1$H/$^2$H RF coils are fabricated using a semi-flexible RG-405 .086" coaxial cable and bench test results (scattering parameters and magnetic field efficiency/distribution) are successfully obtained. $Conclusion:$ The proposed dual-tuned RF coils reveal highly effective magnetic field obtained from both proton and heteronuclear signal which is crucial for accurate and detailed imaging. $Significance:$ The successful development of this new dual-tuned RF coil technique would provide a tangible and efficient tool for ultrahigh field metabolic MR imaging.
△ Less
Submitted 26 October, 2023; v1 submitted 20 July, 2023;
originally announced July 2023.
-
Double Cross Magnetic Wall Decoupling for Quadrature Transceiver RF Array Coils using Common-Mode Differential-mode Resonators
Authors:
Komlan Payne,
Aditya Ashok Bhosale,
Xiaoliang Zhang
Abstract:
In contrast to linearly polarized RF coil arrays, quadrature transceiver coil arrays are capable of improving signal-to-noise ratio (SNR), spatial resolution and parallel imaging performance. Owing to a reduced excitation power, low specific absorption rate can be also obtained using quadrature RF coils. However, due to the complex nature of their structure and their electromagnetic proprieties, i…
▽ More
In contrast to linearly polarized RF coil arrays, quadrature transceiver coil arrays are capable of improving signal-to-noise ratio (SNR), spatial resolution and parallel imaging performance. Owing to a reduced excitation power, low specific absorption rate can be also obtained using quadrature RF coils. However, due to the complex nature of their structure and their electromagnetic proprieties, it is challenging to achieve sufficient electromagnetic decoupling while designing multichannel quadrature RF coil arrays, particularly at ultrahigh fields. In this work, we proposed a double cross magnetic wall decoupling for quadrature transceiver RF arrays and implemented the decoupling method on common-mode differential mode quadrature (CMDM) quadrature transceiver arrays at ultrahigh field of 7T. The proposed magnetic decoupling wall comprised of two intrinsic decoupled loops is used to reduce the mutual coupling between all the multi-mode current present in the quadrature CMDM array. The decoupling network has no physical connection with the CMDMs' coils giving leverage over size adjustable RF arrays. In order to validate the feasibility of the proposed cross magnetic decoupling wall, systematic studies on the decoupling performance based on the impedance of two intrinsic loops are numerically performed. A pair of quadrature transceiver CMDMs is constructed along with the proposed decoupling network and their scattering matrix is characterized using a network analyzer. The measured results show all the current modes coupling are concurrently suppressed using the proposed cross magnetic wall. Moreover, field distribution, and SNR intensity are numerically obtained for a well-decoupled 8-channel quadrature knee-coil array.
△ Less
Submitted 24 December, 2022;
originally announced December 2022.
-
A Portal for High-Precision Atomic Data and Computation: Design and Best Practices
Authors:
Parinaz Barakhshan,
Akshay Bhosale,
Amani Kiruga,
Rudolf Eigenmann,
Marianna S. Safronova,
Bindiya Arora
Abstract:
The Atom portal, udel.edu/atom, provides the scientific community with easily accessible high-quality data about properties of atoms and ions, such as energies, transition matrix elements, transition rates, radiative lifetimes, branching ratios, polarizabilities, and hyperfine constants. The data are calculated using a high-precision state-of-the-art linearized coupled-cluster method, high-precisi…
▽ More
The Atom portal, udel.edu/atom, provides the scientific community with easily accessible high-quality data about properties of atoms and ions, such as energies, transition matrix elements, transition rates, radiative lifetimes, branching ratios, polarizabilities, and hyperfine constants. The data are calculated using a high-precision state-of-the-art linearized coupled-cluster method, high-precision experimental values are used where available. All values include estimated uncertainties. Where available, experimental results are provided with references. This paper provides an overview of the portal and describes the design as well as applied software engineering practices.
△ Less
Submitted 20 December, 2022;
originally announced December 2022.
-
A Multichannel RF Transceiver Array with mixed L-C loop and microstrip elements for Foot/Ankle MR Imaging at 7T
Authors:
Aditya Bhosale,
Leslie Ying,
Xiaoliang Zhang
Abstract:
It is technically challenging to design efficient transceiver coil arrays for foot and ankle imaging at ultrahigh fields due to the irregular geometry of the anatomy. Shortened wavelength because of the high operation frequency at ultrahigh fields increases phase variation, leading to inhomogeneous B1 distribution in the imaging sample. In this work, we propose a hybrid design with mixed L-C loops…
▽ More
It is technically challenging to design efficient transceiver coil arrays for foot and ankle imaging at ultrahigh fields due to the irregular geometry of the anatomy. Shortened wavelength because of the high operation frequency at ultrahigh fields increases phase variation, leading to inhomogeneous B1 distribution in the imaging sample. In this work, we propose a hybrid design with mixed L-C loops and microstrip resonators for multichannel foot/ankle transceiver arrays at the ultrahigh field of 7T. The proposed transceiver array consists of 14 microstrip resonators and 5 L-C loop coils to cover the entire region of interest of the irregular-shaped foot/ankle with a relatively uniform B1 distribution at 7T. The feasibility and field behavior of the proposed design are systematically investigated numerically.
△ Less
Submitted 24 August, 2022;
originally announced August 2022.
-
High Dielectric Sheet to reduce Electric Fields and Flatten Magnetic Fields in Self-decoupled Radiofrequency coils for MR Imaging
Authors:
Aditya Bhosale,
Xiaoliang Zhang
Abstract:
High impedance RF coils, such as self-decoupled coils, reduce the electromagnetic coupling between the coil elements and eliminates the use of complex decoupling technologies. Although the high impedance design promises excellent decoupling between the coil elements, it also results in high electric fields across the RF coil, leading to potential safety problems during imaging. It also causes B1 f…
▽ More
High impedance RF coils, such as self-decoupled coils, reduce the electromagnetic coupling between the coil elements and eliminates the use of complex decoupling technologies. Although the high impedance design promises excellent decoupling between the coil elements, it also results in high electric fields across the RF coil, leading to potential safety problems during imaging. It also causes B1 field asymmetry, ultimately leading to difficulties in imaging quantification. In this study, we propose and investigate using a high dielectric sheet to reduce the electric fields across the coil and achieve excellent electromagnetic decoupling among the coil elements, thereby ensuring safer MRI at ultra-high fields and maintaining high imaging performance.
△ Less
Submitted 29 May, 2022;
originally announced May 2022.
-
Design of a 13-Channel Hybrid Array System for Foot/Ankle Magnetic Resonance Imaging at 7T/300MHz
Authors:
Aditya Bhosale,
Leslie Ying,
Xiaoliang Zhang
Abstract:
Microstrip lines are being used in MR applications due to their unique properties, such as reduced radiation loss, high-frequency capability, and reduced perturbation of sample loading to the RF coil compared to conventional coils. Here, we present the design of the 13-channel hybrid array consisting of 12 Microstrips, 1 volume half birdcage coil placed on the foot/ankle phantom, and high permitti…
▽ More
Microstrip lines are being used in MR applications due to their unique properties, such as reduced radiation loss, high-frequency capability, and reduced perturbation of sample loading to the RF coil compared to conventional coils. Here, we present the design of the 13-channel hybrid array consisting of 12 Microstrips, 1 volume half birdcage coil placed on the foot/ankle phantom, and high permittivity materials to cover the maximum area of the subject at 7T/300MHz. We demonstrate using electromagnetic simulations, magnetic field distribution, SAR performance, and the coupling performance of the array elements. This work provides an ultrahigh field multichannel RF solution to lower extremity MR imaging with excellent imaging coverage and field uniformity.
△ Less
Submitted 29 May, 2022;
originally announced May 2022.
-
Compile-time Parallelization of Subscripted Subscript Patterns
Authors:
Akshay Bhosale,
Rudolf Eigenmann
Abstract:
An increasing number of scientific applications are making use of irregular data access patterns. An important class of such patterns involve subscripted-subscripts, wherein an array value appears in the index expression of another array. Even though the information required to parallelize loops with such patterns is often available in the program, present compiler techniques fall short of analyzi…
▽ More
An increasing number of scientific applications are making use of irregular data access patterns. An important class of such patterns involve subscripted-subscripts, wherein an array value appears in the index expression of another array. Even though the information required to parallelize loops with such patterns is often available in the program, present compiler techniques fall short of analyzing that information. In this paper we present a study of subscripted-subscripts, the properties that define the subscript arrays, and an algorithm based on symbolic range aggregation, that will help prove the presence of some of the properties of the subscript array in the program. We show that, in an important class of programs, the algorithm can boost the performance from essentially sequential execution to close to fully parallel.
△ Less
Submitted 13 November, 2019;
originally announced November 2019.
-
PySPH: a Python-based framework for smoothed particle hydrodynamics
Authors:
Prabhu Ramachandran,
Aditya Bhosale,
Kunal Puri,
Pawan Negi,
Abhinav Muta,
A Dinesh,
Dileep Menon,
Rahul Govind,
Suraj Sanka,
Amal S Sebastian,
Ananyo Sen,
Rohan Kaushik,
Anshuman Kumar,
Vikas Kurapati,
Mrinalgouda Patil,
Deep Tavker,
Pankaj Pandey,
Chandrashekhar Kaushik,
Arkopal Dutt,
Arpit Agarwal
Abstract:
PySPH is an open-source, Python-based, framework for particle methods in general and Smoothed Particle Hydrodynamics (SPH) in particular. PySPH allows a user to define a complete SPH simulation using pure Python. High-performance code is generated from this high-level Python code and executed on either multiple cores, or on GPUs, seamlessly. It also supports distributed execution using MPI. PySPH…
▽ More
PySPH is an open-source, Python-based, framework for particle methods in general and Smoothed Particle Hydrodynamics (SPH) in particular. PySPH allows a user to define a complete SPH simulation using pure Python. High-performance code is generated from this high-level Python code and executed on either multiple cores, or on GPUs, seamlessly. It also supports distributed execution using MPI. PySPH supports a wide variety of SPH schemes and formulations. These include, incompressible and compressible fluid flow, elastic dynamics, rigid body dynamics, shallow water equations, and other problems. PySPH supports a variety of boundary conditions including mirror, periodic, solid wall, and inlet/outlet boundary conditions. The package is written to facilitate reuse and reproducibility. This paper discusses the overall design of PySPH and demonstrates many of its features. Several example results are shown to demonstrate the range of features that PySPH provides.
△ Less
Submitted 28 December, 2020; v1 submitted 10 September, 2019;
originally announced September 2019.