-
Resonant structure for improved directionality and extraction of single photons
Authors:
Sagar Chowdhury,
Rituraj,
Srini Krishnamurthy,
Vidya Praveen Bhallamudi
Abstract:
Fluorescent atomic defects, especially in dielectric materials, such as diamond are quite promising for several emerging quantum applications. However, efficient light extraction, directional emission, and narrow spectral emission are key challenges. We have designed dielectric metasurface exploiting Mie-resonance and the Kerker condition to address these issues. Our designed diamond metasurface,…
▽ More
Fluorescent atomic defects, especially in dielectric materials, such as diamond are quite promising for several emerging quantum applications. However, efficient light extraction, directional emission, and narrow spectral emission are key challenges. We have designed dielectric metasurface exploiting Mie-resonance and the Kerker condition to address these issues. Our designed diamond metasurface, tailored for nitrogen-vacancy (NV) defect centers in diamond, predicts up to 500x improvement in the collection of 637 nm (zero phonon line) photons over that from the bare diamond. Our design achieves highly directional emission, predominantly emitting in a 20 degree lobe in the forward direction. This makes light collection more efficient, including for fiber-based collection. The predicted results are stable against the position of the emitter placed in the metaelement, thus alleviating the challenging fabrication requirement of precise positioning of the defect center. Equally importantly, our design approach can be applied to enhance single photon emission also from other defects such as SiV, other materials such as hBN, and other sources such as quantum dots.
△ Less
Submitted 8 May, 2024; v1 submitted 7 May, 2024;
originally announced May 2024.
-
Single and double quantum transitions in spin-mixed states under photo-excitation
Authors:
Anand Patel,
Zainab Chowdhry,
Anil Prabhakar,
A. Rathi,
V. P. Bhallamudi
Abstract:
Electronic spins associated with the Nitrogen-Vacancy (NV) center in diamond offer an opportunity to study spin-related phenomena with extremely high sensitivity owing to their high degree of optical polarization. Here, we study both single- and double-quantum transitions (SQT and DQT) in NV centers between spin-mixed states, which arise from magnetic fields that are non-collinear to the NV axis.…
▽ More
Electronic spins associated with the Nitrogen-Vacancy (NV) center in diamond offer an opportunity to study spin-related phenomena with extremely high sensitivity owing to their high degree of optical polarization. Here, we study both single- and double-quantum transitions (SQT and DQT) in NV centers between spin-mixed states, which arise from magnetic fields that are non-collinear to the NV axis. We demonstrate the amplification of the ESR signal from both these types of transition under laser illumination. We obtain hyperfine-resolved X-band ESR signal as a function of both excitation laser power and misalignment of static magnetic field with the NV axis. This combined with our analysis using a seven-level model that incorporates thermal polarization and double quantum relaxation allows us to comprehensively analyze the polarization of NV spins under off-axis fields. Such detailed understanding of spin-mixed states in NV centers under photo-excitation can help greatly in realizing NV-diamond platform's potential in sensing correlated magnets and biological samples, as well as other emerging applications, such as masing and nuclear hyperpolarization.
△ Less
Submitted 30 June, 2023;
originally announced June 2023.
-
Using Entangled Generalized Coherent States for Photonic Quantum Metrology
Authors:
Madhura Ghosh Dastidar,
Aprameyan Desikan,
Vidya Praveen Bhallamudi
Abstract:
Quantum metrology aims at achieving enhanced performance in measuring unknown parameters by utilizing quantum resources. Thus, quantum metrology is an important application of quantum technologies. Photonic systems can implement these metrological tasks with simpler experimental techniques. We present a scheme for improved parameter estimation by introducing entangled generalized coherent states (…
▽ More
Quantum metrology aims at achieving enhanced performance in measuring unknown parameters by utilizing quantum resources. Thus, quantum metrology is an important application of quantum technologies. Photonic systems can implement these metrological tasks with simpler experimental techniques. We present a scheme for improved parameter estimation by introducing entangled generalized coherent states (EGCS) for photonic quantum metrology. These states show enhanced sensitivity beyond the classical and Heisenberg limits and prove to be advantageous as compared to the entangled coherent and NOON states. Further, we also propose a scheme for experimentally generating certain entangled generalized coherent states with current technology.
△ Less
Submitted 17 May, 2023;
originally announced May 2023.
-
Synchronized Bell protocol for detecting non-locality between modes of light
Authors:
Madhura Ghosh Dastidar,
Gniewomir Sarbicki,
Vidya Praveen Bhallamudi
Abstract:
In the following paper, we discuss a possible detection of non-locality in two-mode light states in the Bell protocol, where the local observables are constructed using displacement operators, implemented by Mach-Zender Interferometers fed by strong coherent states. We report numerical results showing that maximizing the Braunstein-Caves Chained Bell (BCCB) inequalities requires equal phases of di…
▽ More
In the following paper, we discuss a possible detection of non-locality in two-mode light states in the Bell protocol, where the local observables are constructed using displacement operators, implemented by Mach-Zender Interferometers fed by strong coherent states. We report numerical results showing that maximizing the Braunstein-Caves Chained Bell (BCCB) inequalities requires equal phases of displacements. On the other hand, we prove that non-locality cannot be detected if the phases of displacements are unknown. Hence, the Bell experiment has to be equipped with a synchronization mechanism. We discuss such a mechanism and its consequences.
△ Less
Submitted 29 May, 2023; v1 submitted 11 October, 2022;
originally announced October 2022.
-
Ferromagnetic dynamics detected via one- and two-magnon NV relaxometry
Authors:
Brendan A. McCullian,
Ahmed M. Thabt,
Benjamin A. Gray,
Alex L. Melendez,
Michael S. Wolf,
Vladimir L. Safonov,
Denis V. Pelekhov,
Vidya P. Bhallamudi,
Michael R. Page,
P. Chris Hammel
Abstract:
The NV center in diamond has proven to be a powerful tool for locally characterizing the magnetic response of microwave excited ferromagnets. To date, this has been limited by the requirement that the FMR excitation frequency be less than the NV spin resonance frequency. Here we report NV relaxometry based on a two-magnon Raman-like process, enabling detection of FMR at frequencies higher than the…
▽ More
The NV center in diamond has proven to be a powerful tool for locally characterizing the magnetic response of microwave excited ferromagnets. To date, this has been limited by the requirement that the FMR excitation frequency be less than the NV spin resonance frequency. Here we report NV relaxometry based on a two-magnon Raman-like process, enabling detection of FMR at frequencies higher than the NV frequency. For high microwave drive powers, we observe an unexpected field-shift of the NV response relative to a simultaneous microwave absorption signal from a low dam** ferrite film. We show that the field-shifted NV response is due to a second order Suhl instability. The instability creates a large population of non-equilibrium magnons which relax the NV spin, even when the uniform mode FMR frequency exceeds that of the NV spin resonance frequency, hence ruling out the possibility that the NV is relaxed by a single NV-resonant magnon. We argue that at high frequencies the NV response is due to a two-magnon relaxation process in which the difference frequency of two magnons matches the NV frequency, and at low frequencies we evaluate the lineshape of the one-magnon NV relaxometry response using spinwave instability theory.
△ Less
Submitted 3 November, 2019;
originally announced November 2019.
-
Voltage driven, local, and efficient excitation of nitrogen-vacancy centers in diamond
Authors:
Dominic Labanowski,
Vidya P. Bhallamudi,
Qiaochu Guo,
Carola M. Purser,
Brendan A. McCullian,
P. Chris Hammel,
Sayeef Salahuddin
Abstract:
Magnetic sensing technology has found widespread application in industries as diverse as transportation, medicine, and resource exploration. Such use cases often require highly sensitive instruments to measure the extremely small magnetic fields involved, relying on difficult to integrate Superconducting Quantum Interference Device (SQUID) and Spin-Exchange Relaxation Free (SERF) magnetometers. A…
▽ More
Magnetic sensing technology has found widespread application in industries as diverse as transportation, medicine, and resource exploration. Such use cases often require highly sensitive instruments to measure the extremely small magnetic fields involved, relying on difficult to integrate Superconducting Quantum Interference Device (SQUID) and Spin-Exchange Relaxation Free (SERF) magnetometers. A potential alternative, nitrogen vacancy (NV) centers in diamond, has shown great potential as a high sensitivity and high resolution magnetic sensor capable of operating in an unshielded, room-temperature environment. Transitioning NV center based sensors into practical devices, however, is impeded by the need for high power RF excitation to manipulate them. Here we report an advance that combines two different physical phenomena to enable a highly efficient excitation of the NV centers: magnetoelastic drive of ferromagnetic resonance (FMR) and NV-magnon coupling. Our work demonstrates a new pathway to combine acoustics and magnonics that enables highly energy efficient and local excitation of NV centers without the need for any external RF excitation, and thus could lead to completely integrated, on-chip, atomic sensors.
△ Less
Submitted 9 March, 2018; v1 submitted 7 March, 2018;
originally announced March 2018.
-
Broadband EPR Spectroscopy in Diverse Field Conditions Using Optically Detected Nitrogen-Vacancy Centers in Diamond
Authors:
C. M. Purser,
V. P. Bhallamudi,
C. S. Wolfe,
H. Yusuf,
B. A. McCullian,
C. Jayaprakash,
M. E. Flatté,
P. C. Hammel
Abstract:
Paramagnetic magnetic resonance, a powerful technique for characterizing and identifying chemical targets, is increasingly used for imaging; however, low spin polarization at room temperature and moderate magnetic fields poses challenges for detecting small numbers of spins. In this work, we use fluorescence from nitrogen-vacancy (NV) centers in diamond to detect the electron paramagnetic resonanc…
▽ More
Paramagnetic magnetic resonance, a powerful technique for characterizing and identifying chemical targets, is increasingly used for imaging; however, low spin polarization at room temperature and moderate magnetic fields poses challenges for detecting small numbers of spins. In this work, we use fluorescence from nitrogen-vacancy (NV) centers in diamond to detect the electron paramagnetic resonance (EPR) spectrum of optically inactive target spins under various conditions of field magnitude and orientation. The protocol requires neither direct microwave manipulation of the NV spins nor spectral overlap between NV and target spin resonances, thus enabling broadband detection. This unexpected non-resonant coupling is attributable to a two-phonon process that relaxes NV spins proximate to the fluctuating dipole moment of the target spin, suggesting that the sensitivity is determined by the dipole-dipole coupling strength. This approach holds promise for sensitive EPR detection, particularly in settings where control over the diamond-crystal orientation is difficult. This is notably the case for biological sensing applications, where nanodiamonds are being pursued for their bright, stable fluorescence and biocompatibility.
△ Less
Submitted 20 February, 2019; v1 submitted 26 February, 2018;
originally announced February 2018.
-
Optically Detected Ferromagnetic Resonance in Metallic Ferromagnets via Nitrogen Vacancy Centers in Diamond
Authors:
Michael R. Page,
Feng Guo,
Carola M. Purser,
Joseph G. Schulze,
Tomoya M. Nakatani,
Christopher S. Wolfe,
Jeffrey R. Childress,
P. Chris Hammel,
Gregory D. Fuchs,
Vidya P. Bhallamudi
Abstract:
We report quantitative measurements of optically detected ferromagnetic resonance (ODFMR) of ferromagnetic thin films that use nitrogen-vacancy (NV) centers in diamonds to transduce FMR into a fluorescence intensity variation. To uncover the mechanism responsible for these signals, we study ODFMR as we 1) vary the separation of the NV centers from the ferromagnet (FM), 2) record the NV center long…
▽ More
We report quantitative measurements of optically detected ferromagnetic resonance (ODFMR) of ferromagnetic thin films that use nitrogen-vacancy (NV) centers in diamonds to transduce FMR into a fluorescence intensity variation. To uncover the mechanism responsible for these signals, we study ODFMR as we 1) vary the separation of the NV centers from the ferromagnet (FM), 2) record the NV center longitudinal relaxation time $T_1$ during FMR, and 3) vary the material properties of the FM. Based on the results, we propose the following mechanism for ODFMR. Decay and scattering of the driven, uniform FMR mode results in spinwaves that produce fluctuating dipolar fields in a spectrum of frequencies. When the spinwave spectrum overlaps the NV center ground-state spin resonance frequencies, the dipolar fields from these resonant spinwaves relax the NV center spins, resulting in an ODFMR signal. These results lay the foundation for an approach to NV center spin relaxometry to study FM dynamics without the constraint of directly matching the NV center spin-transition frequency to the magnetic system of interest, thus enabling an alternate modality for scanned-probe magnetic microscopy that can sense ferromagnetic resonance with nanoscale resolution.
△ Less
Submitted 25 July, 2016;
originally announced July 2016.
-
Magnetic Resonance Force Detection using a Membrane Resonator
Authors:
Nicolas Scozzaro,
Will Ruchotzke,
Amanda Belding,
Jeremy D. Cardellino,
Erick C. Blomberg,
Brendan A. McCullian,
Vidya P. Bhallamudi,
Denis V. Pelekhov,
P. Chris Hammel
Abstract:
The availability of compact, low-cost magnetic resonance imaging instruments would further broaden the substantial impact of this technology. We report highly sensitive detection of magnetic resonance using low-stress silicon nitride (SiN$_x$) membranes. We use these membranes as low-loss, high-frequency mechanical oscillators and find they are able to mechanically detect spin-dependent forces wit…
▽ More
The availability of compact, low-cost magnetic resonance imaging instruments would further broaden the substantial impact of this technology. We report highly sensitive detection of magnetic resonance using low-stress silicon nitride (SiN$_x$) membranes. We use these membranes as low-loss, high-frequency mechanical oscillators and find they are able to mechanically detect spin-dependent forces with high sensitivity enabling ultrasensitive magnetic resonance detection. The high force detection sensitivity stems from their high mechanical quality factor $Q\sim10^6$ combined with the low mass of the resonator. We use this excellent mechanical force sensitivity to detect the electron spin magnetic resonance using a SiN$_x$ membrane as a force detector. The demonstrated force sensitivity at 300 K is 4 fN/$\sqrt{\mathrm{Hz}}$, indicating a potential low temperature (4 K) sensitivity of 25 aN/$\sqrt{\mathrm{Hz}}$. Given their sensitivity, robust construction, large surface area and low cost, SiN$_x$ membranes can potentially serve as the central component of a compact room-temperature ESR and NMR instrument that has superior spatial resolution to conventional approaches.
△ Less
Submitted 28 March, 2016; v1 submitted 12 March, 2016;
originally announced March 2016.
-
Spatially resolved detection of complex ferromagnetic dynamics using optically detected NV spins
Authors:
Chris. S. Wolfe,
Sergei. A. Manuilov,
Carola. M. Purser,
Richelle Teeling-Smith,
Carsten. Dubs,
P. Chris Hammel,
Vidya Praveen Bhallamudi
Abstract:
We demonstrate optical detection of a broad spectrum of ferromagnetic excitations using nitrogen-vacancy (NV) centers in an ensemble of nanodiamonds. Our recently developed approach exploits a straightforward CW detection scheme using readily available diamond detectors, making it easily implementable. The NV center is a local detector, giving the technique spatial resolution, which here is define…
▽ More
We demonstrate optical detection of a broad spectrum of ferromagnetic excitations using nitrogen-vacancy (NV) centers in an ensemble of nanodiamonds. Our recently developed approach exploits a straightforward CW detection scheme using readily available diamond detectors, making it easily implementable. The NV center is a local detector, giving the technique spatial resolution, which here is defined by our laser spot, but in principle can be extended far into the nanoscale. Among the excitations we observe are propagating dipolar and dipolar-exchange spinwaves, as well as dynamics associated with the multi-domain state of the ferromagnet at low fields. These results offer an approach, distinct from commonly used ODMR techniques, for spatially resolved spectroscopic study of magnetization dynamics at the nanoscale.
△ Less
Submitted 23 February, 2016; v1 submitted 16 December, 2015;
originally announced December 2015.
-
NV Center Electron Paramagnetic Resonance of a Single Nanodiamond Attached to an Individual Biomolecule
Authors:
Richelle M. Teeling-Smith,
Young Woo Jung,
Nicolas Scozzaro,
Jeremy Cardellino,
Isaac Rampersaud,
Justin A. North,
Marek Šimon,
Vidya P. Bhallamudi,
Arfaan Rampersaud,
Ezekiel Johnston-Halperin,
Michael G. Poirier,
P. Chris Hammel
Abstract:
A key limitation of electron paramagnetic resonance (EPR), an established and powerful tool for studying atomic-scale biomolecular structure and dynamics is its poor sensitivity, samples containing in excess of 10^12 labeled biomolecules are required in typical experiments. In contrast, single molecule measurements provide improved insights into heterogeneous behaviors that can be masked by ensemb…
▽ More
A key limitation of electron paramagnetic resonance (EPR), an established and powerful tool for studying atomic-scale biomolecular structure and dynamics is its poor sensitivity, samples containing in excess of 10^12 labeled biomolecules are required in typical experiments. In contrast, single molecule measurements provide improved insights into heterogeneous behaviors that can be masked by ensemble measurements and are often essential for illuminating the molecular mechanisms behind the function of a biomolecule. We report EPR measurements of a single labeled biomolecule that merge these two powerful techniques. We selectively label an individual double-stranded DNA molecule with a single nanodiamond containing nitrogen-vacancy (NV) centers, and optically detect the paramagnetic resonance of NV spins in the nanodiamond probe. Analysis of the spectrum reveals that the nanodiamond probe has complete rotational freedom and that the characteristic time scale for reorientation of the nanodiamond probe is slow compared to the transverse spin relaxation time. This demonstration of EPR spectroscopy of a single nanodiamond labeled DNA provides the foundation for the development of single molecule magnetic resonance studies of complex biomolecular systems.
△ Less
Submitted 20 November, 2015;
originally announced November 2015.
-
Correlating spin transport and electrode magnetization in a graphene spin valve: simultaneous magnetic microscopy and non-local measurements
Authors:
Andrew J. Berger,
Michael R. Page,
Hua Wen,
Kathleen M. McCreary,
Vidya P. Bhallamudi,
Roland K. Kawakami,
P. Chris Hammel
Abstract:
Using simultaneous magnetic force microscopy (MFM) and transport measurements of a graphene spin valve, we correlate the non-local spin signal with the magnetization of the device electrodes. The imaged magnetization states corroborate the influence of each electrode within a one-dimensional spin transport model and provide evidence linking domain wall pinning to additional features in the transpo…
▽ More
Using simultaneous magnetic force microscopy (MFM) and transport measurements of a graphene spin valve, we correlate the non-local spin signal with the magnetization of the device electrodes. The imaged magnetization states corroborate the influence of each electrode within a one-dimensional spin transport model and provide evidence linking domain wall pinning to additional features in the transport signal.
△ Less
Submitted 17 July, 2015;
originally announced July 2015.
-
A versatile LabVIEW and FPGA-based scanned probe microscope for in-operando electronic device characterization
Authors:
Andrew J. Berger,
Michael R. Page,
Jan Jacob,
Justin R. Young,
Jim Lewis,
Lothar Wenzel,
Vidya P. Bhallamudi,
Ezekiel Johnston-Halperin,
Denis V. Pelekhov,
P. Chris Hammel
Abstract:
Understanding the complex properties of electronic and spintronic devices at the micro- and nano-scale is a topic of intense current interest as it becomes increasingly important for scientific progress and technological applications. In-operando characterization of such devices by scanned probe techniques is particularly well-suited for the microscopic study of these properties. We have developed…
▽ More
Understanding the complex properties of electronic and spintronic devices at the micro- and nano-scale is a topic of intense current interest as it becomes increasingly important for scientific progress and technological applications. In-operando characterization of such devices by scanned probe techniques is particularly well-suited for the microscopic study of these properties. We have developed a scanned probe microscope (SPM) which is capable of both standard force imaging (atomic, magnetic, electrostatic) and simultaneous electrical transport measurements. We utilize flexible and inexpensive FPGA (field programmable gate array) hardware and a custom software framework developed in National Instrument's LabVIEW environment to perform the various aspects of microscope operation and device measurement. The FPGA-based approach enables sensitive, real-time cantilever frequency-shift detection. Using this system, we demonstrate electrostatic force microscopy of an electrically-biased graphene FET device. The combination of SPM and electrical transport also enables imaging of the transport response to a localized perturbation provided by the scanned cantilever tip. Facilitated by the broad presence of LabVIEW in the experimental sciences and the openness of our software solution, our system permits a wide variety of combined scanning and transport measurements by providing standardized interfaces and flexible access to all aspects of a measurement (input and output signals, and processed data). Our system also enables precise control of timing (synchronization of scanning and transport operations) and implementation of sophisticated feedback protocols, and thus should be broadly interesting and useful to practitioners in the field.
△ Less
Submitted 1 October, 2014;
originally announced October 2014.
-
Dam** of Confined Modes in a Ferromagnetic Thin Insulating Film: Angular Momentum Transfer Across a Nanoscale Field-defined Interface
Authors:
Rohan Adur,
Chunhui Du,
Hailong Wang,
Sergei A. Manuilov,
Vidya P. Bhallamudi,
Chi Zhang,
Denis V. Pelekhov,
Fengyuan Yang,
P. Chris Hammel
Abstract:
We observe a dependence of the dam** of a confined mode of precessing ferromagnetic magnetization on the size of the mode. The micron-scale mode is created within an extended, unpatterned YIG film by means of the intense local dipolar field of a micromagnetic tip. We find that dam** of the confined mode scales like the surface-to-volume ratio of the mode, indicating an interfacial dam** effe…
▽ More
We observe a dependence of the dam** of a confined mode of precessing ferromagnetic magnetization on the size of the mode. The micron-scale mode is created within an extended, unpatterned YIG film by means of the intense local dipolar field of a micromagnetic tip. We find that dam** of the confined mode scales like the surface-to-volume ratio of the mode, indicating an interfacial dam** effect (similar to spin pum**) due to the transfer of angular momentum from the confined mode to the spin sink of ferromagnetic material in the surrounding film. Though unexpected for insulating systems, the measured intralayer spin-mixing conductance $g_{\uparrow \downarrow} = 5.3 \times 10^{19} {\rm m}^{-2}$ demonstrates efficient intralayer angular momentum transfer.
△ Less
Submitted 7 August, 2014; v1 submitted 16 May, 2014;
originally announced May 2014.
-
Off-Resonant Manipulation of Spins in Diamond via Precessing Magnetization of a Proximal Ferromagnet
Authors:
Chris S. Wolfe,
Vidya P. Bhallamudi,
Hilong L. Wang,
Chunhui H. Du,
Sergei Manuilov,
Andrew J. Berger,
Rohan Adur,
Fengyuan Y. Yang,
P. Chris Hammel
Abstract:
We report the manipulation of nitrogen vacancy (NV) spins in diamond when nearby ferrimagnetic insulator, yttrium iron garnet, is driven into precession. The change in NV spin polarization, as measured by changes in photoluminescence, is comparable in magnitude to that from conventional optically detected magnetic resonance, but relies on a distinct mechanism as it occurs at a microwave frequency…
▽ More
We report the manipulation of nitrogen vacancy (NV) spins in diamond when nearby ferrimagnetic insulator, yttrium iron garnet, is driven into precession. The change in NV spin polarization, as measured by changes in photoluminescence, is comparable in magnitude to that from conventional optically detected magnetic resonance, but relies on a distinct mechanism as it occurs at a microwave frequency far removed from the magnetic resonance frequency of the NV spin. This observation presents a new approach to transferring ferromagnetic spin information into a paramagnet and then transducing the response into a robust optical signal. It also opens new avenues for studying ferromagnetism and spin transport at the nanoscale.
△ Less
Submitted 3 March, 2014;
originally announced March 2014.
-
Experimental Demonstration Of Scanned Spin-Precession Microscopy
Authors:
V. P. Bhallamudi,
C. S. Wolfe,
V. P. Amin,
D. E. Labanowski,
A. J. Berger,
D. Stroud,
J. Sinova,
P. C. Hammel
Abstract:
Progress in spintronics has been aided by characterization tools tailored to certain archetypical materials. New device structures and materials will require characterization tools that are material independent, provide sufficient resolution to image locally-varying spin properties and enable subsurface imaging. Here we report the demonstration of a novel spin-microscopy tool based on the variatio…
▽ More
Progress in spintronics has been aided by characterization tools tailored to certain archetypical materials. New device structures and materials will require characterization tools that are material independent, provide sufficient resolution to image locally-varying spin properties and enable subsurface imaging. Here we report the demonstration of a novel spin-microscopy tool based on the variation of a global spin-precession signal in response to the localized magnetic field of a scanned probe. We map the local spin density in optically pumped GaAs from this spatially-averaged signal with a resolution of 5.5 microns. This methodology is also applicable to other spin properties and its resolution can be improved. It can extend spin microscopy to device structures not accessible by other techniques, such as buried interfaces and non-optically active materials, due to the universal nature of magnetic interactions between the spins and the probe.
△ Less
Submitted 29 November, 2012;
originally announced November 2012.
-
Imaging spin properties using spatially varying magnetic fields
Authors:
V. P. Bhallamudi,
A. J. Berger,
D. E. Labanowski,
D. Stroud,
P. C. Hammel
Abstract:
We present a novel method to image spin properties of spintronic systems using the spatially confined field of a scanned micromagnetic probe, in conjunction with existing electrical or optical global spin detection schemes. It is thus applicable to all materials systems susceptible to either of those approaches. The proposed technique relies on numerical solutions to the spin diffusion equation in…
▽ More
We present a novel method to image spin properties of spintronic systems using the spatially confined field of a scanned micromagnetic probe, in conjunction with existing electrical or optical global spin detection schemes. It is thus applicable to all materials systems susceptible to either of those approaches. The proposed technique relies on numerical solutions to the spin diffusion equation in the presence of spatially varying fields to obtain the local spin response to the micromagnetic probe field. These solutions also provide insight into the effects of inhomogeneities on Hanle measurements.
△ Less
Submitted 15 January, 2011; v1 submitted 18 October, 2010;
originally announced October 2010.