-
Self-supervised learning for classifying paranasal anomalies in the maxillary sinus
Authors:
Debayan Bhattacharya,
Finn Behrendt,
Benjamin Tobias Becker,
Lennart Maack,
Dirk Beyersdorff,
Elina Petersen,
Marvin Petersen,
Bastian Cheng,
Dennis Eggert,
Christian Betz,
Anna Sophie Hoffmann,
Alexander Schlaefer
Abstract:
Purpose: Paranasal anomalies, frequently identified in routine radiological screenings, exhibit diverse morphological characteristics. Due to the diversity of anomalies, supervised learning methods require large labelled dataset exhibiting diverse anomaly morphology. Self-supervised learning (SSL) can be used to learn representations from unlabelled data. However, there are no SSL methods designed…
▽ More
Purpose: Paranasal anomalies, frequently identified in routine radiological screenings, exhibit diverse morphological characteristics. Due to the diversity of anomalies, supervised learning methods require large labelled dataset exhibiting diverse anomaly morphology. Self-supervised learning (SSL) can be used to learn representations from unlabelled data. However, there are no SSL methods designed for the downstream task of classifying paranasal anomalies in the maxillary sinus (MS).
Methods: Our approach uses a 3D Convolutional Autoencoder (CAE) trained in an unsupervised anomaly detection (UAD) framework. Initially, we train the 3D CAE to reduce reconstruction errors when reconstructing normal maxillary sinus (MS) image. Then, this CAE is applied to an unlabelled dataset to generate coarse anomaly locations by creating residual MS images. Following this, a 3D Convolutional Neural Network (CNN) reconstructs these residual images, which forms our SSL task. Lastly, we fine-tune the encoder part of the 3D CNN on a labelled dataset of normal and anomalous MS images.
Results: The proposed SSL technique exhibits superior performance compared to existing generic self-supervised methods, especially in scenarios with limited annotated data. When trained on just 10% of the annotated dataset, our method achieves an Area Under the Precision-Recall Curve (AUPRC) of 0.79 for the downstream classification task. This performance surpasses other methods, with BYOL attaining an AUPRC of 0.75, SimSiam at 0.74, SimCLR at 0.73 and Masked Autoencoding using SparK at 0.75.
Conclusion: A self-supervised learning approach that inherently focuses on localizing paranasal anomalies proves to be advantageous, particularly when the subsequent task involves differentiating normal from anomalous maxillary sinuses. Access our code at https://github.com/mtec-tuhh/self-supervised-paranasal-anomaly
△ Less
Submitted 29 April, 2024;
originally announced April 2024.
-
Tissue Classification During Needle Insertion Using Self-Supervised Contrastive Learning and Optical Coherence Tomography
Authors:
Debayan Bhattacharya,
Sarah Latus,
Finn Behrendt,
Florin Thimm,
Dennis Eggert,
Christian Betz,
Alexander Schlaefer
Abstract:
Needle positioning is essential for various medical applications such as epidural anaesthesia. Physicians rely on their instincts while navigating the needle in epidural spaces. Thereby, identifying the tissue structures may be helpful to the physician as they can provide additional feedback in the needle insertion process. To this end, we propose a deep neural network that classifies the tissues…
▽ More
Needle positioning is essential for various medical applications such as epidural anaesthesia. Physicians rely on their instincts while navigating the needle in epidural spaces. Thereby, identifying the tissue structures may be helpful to the physician as they can provide additional feedback in the needle insertion process. To this end, we propose a deep neural network that classifies the tissues from the phase and intensity data of complex OCT signals acquired at the needle tip. We investigate the performance of the deep neural network in a limited labelled dataset scenario and propose a novel contrastive pretraining strategy that learns invariant representation for phase and intensity data. We show that with 10% of the training set, our proposed pretraining strategy helps the model achieve an F1 score of 0.84 whereas the model achieves an F1 score of 0.60 without it. Further, we analyse the importance of phase and intensity individually towards tissue classification.
△ Less
Submitted 26 April, 2023;
originally announced April 2023.
-
Multiple Instance Ensembling For Paranasal Anomaly Classification In The Maxillary Sinus
Authors:
Debayan Bhattacharya,
Finn Behrendt,
Benjamin Tobias Becker,
Dirk Beyersdorff,
Elina Petersen,
Marvin Petersen,
Bastian Cheng,
Dennis Eggert,
Christian Betz,
Anna Sophie Hoffmann,
Alexander Schlaefer
Abstract:
Paranasal anomalies are commonly discovered during routine radiological screenings and can present with a wide range of morphological features. This diversity can make it difficult for convolutional neural networks (CNNs) to accurately classify these anomalies, especially when working with limited datasets. Additionally, current approaches to paranasal anomaly classification are constrained to ide…
▽ More
Paranasal anomalies are commonly discovered during routine radiological screenings and can present with a wide range of morphological features. This diversity can make it difficult for convolutional neural networks (CNNs) to accurately classify these anomalies, especially when working with limited datasets. Additionally, current approaches to paranasal anomaly classification are constrained to identifying a single anomaly at a time. These challenges necessitate the need for further research and development in this area.
In this study, we investigate the feasibility of using a 3D convolutional neural network (CNN) to classify healthy maxillary sinuses (MS) and MS with polyps or cysts. The task of accurately identifying the relevant MS volume within larger head and neck Magnetic Resonance Imaging (MRI) scans can be difficult, but we develop a straightforward strategy to tackle this challenge. Our end-to-end solution includes the use of a novel sampling technique that not only effectively localizes the relevant MS volume, but also increases the size of the training dataset and improves classification results. Additionally, we employ a multiple instance ensemble prediction method to further boost classification performance. Finally, we identify the optimal size of MS volumes to achieve the highest possible classification performance on our dataset.
With our multiple instance ensemble prediction strategy and sampling strategy, our 3D CNNs achieve an F1 of 0.85 whereas without it, they achieve an F1 of 0.70.
We demonstrate the feasibility of classifying anomalies in the MS. We propose a data enlarging strategy alongside a novel ensembling strategy that proves to be beneficial for paranasal anomaly classification in the MS.
△ Less
Submitted 31 March, 2023;
originally announced March 2023.
-
Unsupervised Anomaly Detection of Paranasal Anomalies in the Maxillary Sinus
Authors:
Debayan Bhattacharya,
Finn Behrendt,
Benjamin Tobias Becker,
Dirk Beyersdorff,
Elina Petersen,
Marvin Petersen,
Bastian Cheng,
Dennis Eggert,
Christian Betz,
Anna Sophie Hoffmann,
Alexander Schlaefer
Abstract:
Deep learning (DL) algorithms can be used to automate paranasal anomaly detection from Magnetic Resonance Imaging (MRI). However, previous works relied on supervised learning techniques to distinguish between normal and abnormal samples. This method limits the type of anomalies that can be classified as the anomalies need to be present in the training data. Further, many data points from normal an…
▽ More
Deep learning (DL) algorithms can be used to automate paranasal anomaly detection from Magnetic Resonance Imaging (MRI). However, previous works relied on supervised learning techniques to distinguish between normal and abnormal samples. This method limits the type of anomalies that can be classified as the anomalies need to be present in the training data. Further, many data points from normal and anomaly class are needed for the model to achieve satisfactory classification performance. However, experienced clinicians can segregate between normal samples (healthy maxillary sinus) and anomalous samples (anomalous maxillary sinus) after looking at a few normal samples. We mimic the clinicians ability by learning the distribution of healthy maxillary sinuses using a 3D convolutional auto-encoder (cAE) and its variant, a 3D variational autoencoder (VAE) architecture and evaluate cAE and VAE for this task. Concretely, we pose the paranasal anomaly detection as an unsupervised anomaly detection problem. Thereby, we are able to reduce the labelling effort of the clinicians as we only use healthy samples during training. Additionally, we can classify any type of anomaly that differs from the training distribution. We train our 3D cAE and VAE to learn a latent representation of healthy maxillary sinus volumes using L1 reconstruction loss. During inference, we use the reconstruction error to classify between normal and anomalous maxillary sinuses. We extract sub-volumes from larger head and neck MRIs and analyse the effect of different fields of view on the detection performance. Finally, we report which anomalies are easiest and hardest to classify using our approach. Our results demonstrate the feasibility of unsupervised detection of paranasal anomalies from MRIs with an AUPRC of 85% and 80% for cAE and VAE, respectively.
△ Less
Submitted 1 November, 2022;
originally announced November 2022.
-
Supervised Contrastive Learning to Classify Paranasal Anomalies in the Maxillary Sinus
Authors:
Debayan Bhattacharya,
Benjamin Tobias Becker,
Finn Behrendt,
Marcel Bengs,
Dirk Beyersdorff,
Dennis Eggert,
Elina Petersen,
Florian Jansen,
Marvin Petersen,
Bastian Cheng,
Christian Betz,
Alexander Schlaefer,
Anna Sophie Hoffmann
Abstract:
Using deep learning techniques, anomalies in the paranasal sinus system can be detected automatically in MRI images and can be further analyzed and classified based on their volume, shape and other parameters like local contrast. However due to limited training data, traditional supervised learning methods often fail to generalize. Existing deep learning methods in paranasal anomaly classification…
▽ More
Using deep learning techniques, anomalies in the paranasal sinus system can be detected automatically in MRI images and can be further analyzed and classified based on their volume, shape and other parameters like local contrast. However due to limited training data, traditional supervised learning methods often fail to generalize. Existing deep learning methods in paranasal anomaly classification have been used to diagnose at most one anomaly. In our work, we consider three anomalies. Specifically, we employ a 3D CNN to separate maxillary sinus volumes without anomalies from maxillary sinus volumes with anomalies. To learn robust representations from a small labelled dataset, we propose a novel learning paradigm that combines contrastive loss and cross-entropy loss. Particularly, we use a supervised contrastive loss that encourages embeddings of maxillary sinus volumes with and without anomaly to form two distinct clusters while the cross-entropy loss encourages the 3D CNN to maintain its discriminative ability. We report that optimising with both losses is advantageous over optimising with only one loss. We also find that our training strategy leads to label efficiency. With our method, a 3D CNN classifier achieves an AUROC of 0.85 while a 3D CNN classifier optimised with cross-entropy loss achieves an AUROC of 0.66.
△ Less
Submitted 5 September, 2022;
originally announced September 2022.
-
Self-Supervised U-Net for Segmenting Flat and Sessile Polyps
Authors:
Debayan Bhattacharya,
Christian Betz,
Dennis Eggert,
Alexander Schlaefer
Abstract:
Colorectal Cancer(CRC) poses a great risk to public health. It is the third most common cause of cancer in the US. Development of colorectal polyps is one of the earliest signs of cancer. Early detection and resection of polyps can greatly increase survival rate to 90%. Manual inspection can cause misdetections because polyps vary in color, shape, size and appearance. To this end, Computer-Aided D…
▽ More
Colorectal Cancer(CRC) poses a great risk to public health. It is the third most common cause of cancer in the US. Development of colorectal polyps is one of the earliest signs of cancer. Early detection and resection of polyps can greatly increase survival rate to 90%. Manual inspection can cause misdetections because polyps vary in color, shape, size and appearance. To this end, Computer-Aided Diagnosis systems(CADx) has been proposed that detect polyps by processing the colonoscopic videos. The system acts a secondary check to help clinicians reduce misdetections so that polyps may be resected before they transform to cancer. Polyps vary in color, shape, size, texture and appearance. As a result, the miss rate of polyps is between 6% and 27% despite the prominence of CADx solutions. Furthermore, sessile and flat polyps which have diameter less than 10 mm are more likely to be undetected. Convolutional Neural Networks(CNN) have shown promising results in polyp segmentation. However, all of these works have a supervised approach and are limited by the size of the dataset. It was observed that smaller datasets reduce the segmentation accuracy of ResUNet++. We train a U-Net to inpaint randomly dropped out pixels in the image as a proxy task. The dataset we use for pre-training is Kvasir-SEG dataset. This is followed by a supervised training on the limited Kvasir-Sessile dataset. Our experimental results demonstrate that with limited annotated dataset and a larger unlabeled dataset, self-supervised approach is a better alternative than fully supervised approach. Specifically, our self-supervised U-Net performs better than five segmentation models which were trained in supervised manner on the Kvasir-Sessile dataset.
△ Less
Submitted 17 October, 2021;
originally announced October 2021.
-
Spectral-Spatial Recurrent-Convolutional Networks for In-Vivo Hyperspectral Tumor Type Classification
Authors:
Marcel Bengs,
Nils Gessert,
Wiebke Laffers,
Dennis Eggert,
Stephan Westermann,
Nina A. Mueller,
Andreas O. H. Gerstner,
Christian Betz,
Alexander Schlaefer
Abstract:
Early detection of cancerous tissue is crucial for long-term patient survival. In the head and neck region, a typical diagnostic procedure is an endoscopic intervention where a medical expert manually assesses tissue using RGB camera images. While healthy and tumor regions are generally easier to distinguish, differentiating benign and malignant tumors is very challenging. This requires an invasiv…
▽ More
Early detection of cancerous tissue is crucial for long-term patient survival. In the head and neck region, a typical diagnostic procedure is an endoscopic intervention where a medical expert manually assesses tissue using RGB camera images. While healthy and tumor regions are generally easier to distinguish, differentiating benign and malignant tumors is very challenging. This requires an invasive biopsy, followed by histological evaluation for diagnosis. Also, during tumor resection, tumor margins need to be verified by histological analysis. To avoid unnecessary tissue resection, a non-invasive, image-based diagnostic tool would be very valuable. Recently, hyperspectral imaging paired with deep learning has been proposed for this task, demonstrating promising results on ex-vivo specimens. In this work, we demonstrate the feasibility of in-vivo tumor type classification using hyperspectral imaging and deep learning. We analyze the value of using multiple hyperspectral bands compared to conventional RGB images and we study several machine learning models' ability to make use of the additional spectral information. Based on our insights, we address spectral and spatial processing using recurrent-convolutional models for effective spectral aggregating and spatial feature learning. Our best model achieves an AUC of 76.3%, significantly outperforming previous conventional and deep learning methods.
△ Less
Submitted 2 July, 2020;
originally announced July 2020.
-
Spatio-spectral deep learning methods for in-vivo hyperspectral laryngeal cancer detection
Authors:
Marcel Bengs,
Stephan Westermann,
Nils Gessert,
Dennis Eggert,
Andreas O. H. Gerstner,
Nina A. Mueller,
Christian Betz,
Wiebke Laffers,
Alexander Schlaefer
Abstract:
Early detection of head and neck tumors is crucial for patient survival. Often, diagnoses are made based on endoscopic examination of the larynx followed by biopsy and histological analysis, leading to a high inter-observer variability due to subjective assessment. In this regard, early non-invasive diagnostics independent of the clinician would be a valuable tool. A recent study has shown that hy…
▽ More
Early detection of head and neck tumors is crucial for patient survival. Often, diagnoses are made based on endoscopic examination of the larynx followed by biopsy and histological analysis, leading to a high inter-observer variability due to subjective assessment. In this regard, early non-invasive diagnostics independent of the clinician would be a valuable tool. A recent study has shown that hyperspectral imaging (HSI) can be used for non-invasive detection of head and neck tumors, as precancerous or cancerous lesions show specific spectral signatures that distinguish them from healthy tissue. However, HSI data processing is challenging due to high spectral variations, various image interferences, and the high dimensionality of the data. Therefore, performance of automatic HSI analysis has been limited and so far, mostly ex-vivo studies have been presented with deep learning. In this work, we analyze deep learning techniques for in-vivo hyperspectral laryngeal cancer detection. For this purpose we design and evaluate convolutional neural networks (CNNs) with 2D spatial or 3D spatio-spectral convolutions combined with a state-of-the-art Densenet architecture. For evaluation, we use an in-vivo data set with HSI of the oral cavity or oropharynx. Overall, we present multiple deep learning techniques for in-vivo laryngeal cancer detection based on HSI and we show that jointly learning from the spatial and spectral domain improves classification accuracy notably. Our 3D spatio-spectral Densenet achieves an average accuracy of 81%.
△ Less
Submitted 21 April, 2020;
originally announced April 2020.
-
Towards Automatic Lesion Classification in the Upper Aerodigestive Tract Using OCT and Deep Transfer Learning Methods
Authors:
Nils Gessert,
Matthias Schlüter,
Sarah Latus,
Veronika Volgger,
Christian Betz,
Alexander Schlaefer
Abstract:
Early detection of cancer is crucial for treatment and overall patient survival. In the upper aerodigestive tract (UADT) the gold standard for identification of malignant tissue is an invasive biopsy. Recently, non-invasive imaging techniques such as confocal laser microscopy and optical coherence tomography (OCT) have been used for tissue assessment. In particular, in a recent study experts class…
▽ More
Early detection of cancer is crucial for treatment and overall patient survival. In the upper aerodigestive tract (UADT) the gold standard for identification of malignant tissue is an invasive biopsy. Recently, non-invasive imaging techniques such as confocal laser microscopy and optical coherence tomography (OCT) have been used for tissue assessment. In particular, in a recent study experts classified lesions in the UADT with respect to their invasiveness using OCT images only. As the results were promising, automatic classification of lesions might be feasible which could assist experts in their decision making. Therefore, we address the problem of automatic lesion classification from OCT images. This task is very challenging as the available dataset is extremely small and the data quality is limited. However, as similar issues are typical in many clinical scenarios we study to what extent deep learning approaches can still be trained and used for decision support.
△ Less
Submitted 10 February, 2019;
originally announced February 2019.
-
Quantum and Tunnelling Capacitance in Charge and Spin Qubits
Authors:
R. Mizuta,
R. M. Otxoa,
A. C. Betz,
M. F. Gonzalez-Zalba
Abstract:
We present a theoretical analysis of the capacitance of a double quantum dot in the charge and spin qubit configurations probed at high-frequencies. We find that in general the total capacitance of the system consists of two state-dependent terms: The quantum capacitance arising from adiabatic charge motion and the tunnelling capacitance that appears when repopulation occurs at a rate comparable o…
▽ More
We present a theoretical analysis of the capacitance of a double quantum dot in the charge and spin qubit configurations probed at high-frequencies. We find that in general the total capacitance of the system consists of two state-dependent terms: The quantum capacitance arising from adiabatic charge motion and the tunnelling capacitance that appears when repopulation occurs at a rate comparable or faster than the probing frequency. The analysis of the capacitance lineshape as a function of externally controllable variables offers a way to characterize the qubits' charge and spin state as well as relevant system parameters such as charge and spin relaxation times, tunnel coupling, electron temperature and electron g-factor. Overall, our analysis provides a formalism to understand dispersive qubit-resonator interactions which can be applied to high-sensitivity and non-invasive quantum-state readout.
△ Less
Submitted 16 August, 2016; v1 submitted 11 April, 2016;
originally announced April 2016.
-
Reconfigurable quadruple quantum dots in a silicon nanowire transistor
Authors:
A. C. Betz,
M. L. V. Tagliaferri,
M. Vinet,
M. Broström,
M. Sanquer,
A. J. Ferguson,
M. F. Gonzalez-Zalba
Abstract:
We present a novel reconfigurable metal-oxide-semiconductor multi-gate transistor that can host a quadruple quantum dot in silicon. The device consist of an industrial quadruple-gate silicon nanowire field-effect transistor. Exploiting the corner effect, we study the versatility of the structure in the single quantum dot and the serial double quantum dot regimes and extract the relevant capacitanc…
▽ More
We present a novel reconfigurable metal-oxide-semiconductor multi-gate transistor that can host a quadruple quantum dot in silicon. The device consist of an industrial quadruple-gate silicon nanowire field-effect transistor. Exploiting the corner effect, we study the versatility of the structure in the single quantum dot and the serial double quantum dot regimes and extract the relevant capacitance parameters. We address the fabrication variability of the quadruple-gate approach which, paired with improved silicon fabrication techniques, makes the corner state quantum dot approach a promising candidate for a scalable quantum information architecture.
△ Less
Submitted 11 March, 2016;
originally announced March 2016.
-
Gate-sensing coherent charge oscillations in a silicon field-effect transistor
Authors:
M. Fernando Gonzalez-Zalba,
Sergey N. Shevchenko,
Sylvain Barraud,
J. Robert Johansson,
Andrew J. Ferguson,
Franco Nori,
Andreas C. Betz
Abstract:
Quantum mechanical effects induced by the miniaturization of complementary metal-oxide-semiconductor (CMOS) technology hamper the performance and scalability prospects of field-effect transistors. However, those quantum effects, such as tunnelling and coherence, can be harnessed to use existing CMOS technology for quantum information processing. Here, we report the observation of coherent charge o…
▽ More
Quantum mechanical effects induced by the miniaturization of complementary metal-oxide-semiconductor (CMOS) technology hamper the performance and scalability prospects of field-effect transistors. However, those quantum effects, such as tunnelling and coherence, can be harnessed to use existing CMOS technology for quantum information processing. Here, we report the observation of coherent charge oscillations in a double quantum dot formed in a silicon nanowire transistor detected via its dispersive interaction with a radio-frequency resonant circuit coupled via the gate. Differential capacitance changes at the inter-dot charge transitions allow us to monitor the state of the system in the strong-driving regime where we observe the emergence of Landau-Zener-St{ü}ckelberg-Majorana interference on the phase response of the resonator. A theoretical analysis of the dispersive signal demonstrates that quantum and tunnelling capacitance changes must be included to describe the qubit-resonator interaction. Furthermore, a Fourier analysis of the interference pattern reveals a charge coherence time, $T_2\approx 100$~ps. Our results demonstrate charge coherent control and readout in a simple silicon transistor and open up the possibility to implement charge and spin qubits in existing CMOS technology.
△ Less
Submitted 18 February, 2016;
originally announced February 2016.
-
Anisotropic magneto-capacitance in ferromagnetic-plate capacitors
Authors:
J. A. Haigh,
C. Ciccarelli,
A. C. Betz,
A. Irvine,
V. Novák,
T. Jungwirth,
J. Wunderlich
Abstract:
The capacitance of a parallel plate capacitor can depend on applied magnetic field. Previous studies have identified capacitance changes induced via classical Lorentz force or spin-dependent Zeeman effects. Here we measure a magnetization direction dependent capacitance in parallel-plate capacitors where one plate is a ferromagnetic semiconductor, gallium manganese arsenide. This anisotropic magne…
▽ More
The capacitance of a parallel plate capacitor can depend on applied magnetic field. Previous studies have identified capacitance changes induced via classical Lorentz force or spin-dependent Zeeman effects. Here we measure a magnetization direction dependent capacitance in parallel-plate capacitors where one plate is a ferromagnetic semiconductor, gallium manganese arsenide. This anisotropic magneto-capacitance is due to the anisotropy in the density of states dependent on the magnetization through the strong spin-orbit interaction.
△ Less
Submitted 1 May, 2015;
originally announced May 2015.
-
Dispersively detected Pauli Spin-Blockade in a Silicon Nanowire Field-Effect Transistor
Authors:
A. C. Betz,
R. Wacquez,
M. Vinet,
X. Jehl,
A L. Saraiva,
M. Sanquer,
A. J. Ferguson,
M. F. Gonzalez-Zalba
Abstract:
We report the dispersive readout of the spin state of a double quantum dot formed at the corner states of a silicon nanowire field-effect transistor. Two face-to-face top-gate electrodes allow us to independently tune the charge occupation of the quantum dot system down to the few-electron limit. We measure the charge stability of the double quantum dot in DC transport as well as dispersively via…
▽ More
We report the dispersive readout of the spin state of a double quantum dot formed at the corner states of a silicon nanowire field-effect transistor. Two face-to-face top-gate electrodes allow us to independently tune the charge occupation of the quantum dot system down to the few-electron limit. We measure the charge stability of the double quantum dot in DC transport as well as dispersively via in-situ gate-based radio frequency reflectometry, where one top-gate electrode is connected to a resonator. The latter removes the need for external charge sensors in quantum computing architectures and provides a compact way to readout the dispersive shift caused by changes in the quantum capacitance during interdot charge transitions. Here, we observe Pauli spin-blockade in the high-frequency response of the circuit at finite magnetic fields between singlet and triplet states. The blockade is lifted at higher magnetic fields when intra-dot triplet states become the ground state configuration. A lineshape analysis of the dispersive phase shift reveals furthermore an intradot valley-orbit splitting $Δ_{vo}$ of 145 $μ$eV. Our results open up the possibility to operate compact CMOS technology as a singlet-triplet qubit and make split-gate silicon nanowire architectures an ideal candidate for the study of spin dynamics.
△ Less
Submitted 1 May, 2015; v1 submitted 12 April, 2015;
originally announced April 2015.
-
Charge dynamics and spin blockade in a hybrid double quantum dot in silicon
Authors:
M. Urdampilleta,
A. Chatterjee,
C. C. Lo,
T. Kobayashi,
J. Mansir,
S. Barraud,
A. C. Betz,
S. Rogge,
M. F. Gonzalez-Zalba,
J. J. L. Morton
Abstract:
Electron spin qubits in silicon, whether in quantum dots or in donor atoms, have long been considered attractive qubits for the implementation of a quantum computer due to the semiconductor vacuum character of silicon and its compatibility with the microelectronics industry. While donor electron spins in silicon provide extremely long coherence times and access to the nuclear spin via the hyperfin…
▽ More
Electron spin qubits in silicon, whether in quantum dots or in donor atoms, have long been considered attractive qubits for the implementation of a quantum computer due to the semiconductor vacuum character of silicon and its compatibility with the microelectronics industry. While donor electron spins in silicon provide extremely long coherence times and access to the nuclear spin via the hyperfine interaction, quantum dots have the complementary advantages of fast electrical operations, tunability and scalability. Here we present an approach to a novel hybrid double quantum dot by coupling a donor to a lithographically patterned artificial atom. Using gate-based rf reflectometry, we probe the charge stability of this double quantum dot system and the variation of quantum capacitance at the interdot charge transition. Using microwave spectroscopy, we find a tunnel coupling of 2.7 GHz and characterise the charge dynamics, which reveals a charge T2* of 200 ps and a relaxation time T1 of 100 ns. Additionally, we demonstrate spin blockade at the inderdot transition, opening up the possibility to operate this coupled system as a singlet-triplet qubit or to transfer a coherent spin state between the quantum dot and the donor electron and nucleus.
△ Less
Submitted 19 March, 2015; v1 submitted 3 March, 2015;
originally announced March 2015.
-
Ambipolar quantum dots in intrinsic silicon
Authors:
A. C. Betz,
M. F. Gonzalez-Zalba,
G. Podd,
A. J. Ferguson
Abstract:
We electrically measure intrinsic silicon quantum dots with electrostatically defined tunnel barriers. The presence of both p-type and n-type ohmic contacts enables the accumulation of either electrons or holes. Thus we are able to study both transport regimes within the same device. We investigate the effect of the tunnel barriers and the electrostatically defined quantum dots. There is greater l…
▽ More
We electrically measure intrinsic silicon quantum dots with electrostatically defined tunnel barriers. The presence of both p-type and n-type ohmic contacts enables the accumulation of either electrons or holes. Thus we are able to study both transport regimes within the same device. We investigate the effect of the tunnel barriers and the electrostatically defined quantum dots. There is greater localisation of charge states under the tunnel barriers in the case of hole conduction leading to higher charge noise in the p-regime.
△ Less
Submitted 13 October, 2014;
originally announced October 2014.
-
A high-sensitivity gate-based charge sensor in silicon
Authors:
M. F. Gonzalez-Zalba,
A. J. Ferguson,
S. Barraud,
A. C. Betz
Abstract:
The implementation of a quantum computer requires a qubit-specific measurement capability to read-out the final state of a quantum system. The model of spin dependent tunneling followed by charge readout has been highly successful in enabling spin qubit experiments in all-electrical, semiconductor based quantum computing. As experiments grow more sophisticated, and head towards multiple qubit arch…
▽ More
The implementation of a quantum computer requires a qubit-specific measurement capability to read-out the final state of a quantum system. The model of spin dependent tunneling followed by charge readout has been highly successful in enabling spin qubit experiments in all-electrical, semiconductor based quantum computing. As experiments grow more sophisticated, and head towards multiple qubit architectures that enable small scale computation, it becomes important to consider the charge read-out overhead. With this in mind, Reilly et al. demonstrated a gate readout scheme in a GaAs double quantum dot that removed the need for an external charge sensor. This readout, which achieved sensitivities of order me/$\sqrt(Hz)$, was enabled by using a resonant circuit to probe the complex radio-frequency polarisability of the double quantum dot. However, the ultimate performance of this technology and the noise sources that limit it remain to be determined. Here, we investigate a gate-based readout scheme using a radio-frequency resonant circuit strongly coupled to a double quantum at the corner states of a silicon nanowire transistor. We find a significantly improved charge sensitivity of 37 $μ$e/$\sqrt(Hz)$. By solving the dynamical master equation of the fast-driven electronic transitions we quantify the noise spectral density and determine the ultimate charge and phase sensitivity of gate-based read-out. We find comparable performance to conventional charge sensors and fundamental limits of order ne/$\sqrt(Hz)$ and $μ$rad/$\sqrt(Hz)$, with the gate-based sensor improving on standard detection for certain device parameters. Our results show that, especially in state-of-the-art silicon qubit architectures, charge detection by probing the complex polarisability has advantages in terms of reducing the readout overhead but also in terms of the absolute charge sensitivity.
△ Less
Submitted 12 May, 2014;
originally announced May 2014.
-
Thermionic charge transport in CMOS nano-transistors
Authors:
A. C. Betz,
S. Barraud,
Q. Wilmart,
B. Plaçais,
X. Jehl,
M. Sanquer,
M. F. Gonzalez - Zalba
Abstract:
We report on DC and microwave electrical transport measurements in silicon-on-insulator CMOS nano-transistors at low and room temperature. At low source-drain voltage, the DC current and RF response show signs of conductance quantization. We attribute this to Coulomb blockade resulting from barriers formed at the spacer-gate interfaces. We show that at high bias transport occurs thermionically ove…
▽ More
We report on DC and microwave electrical transport measurements in silicon-on-insulator CMOS nano-transistors at low and room temperature. At low source-drain voltage, the DC current and RF response show signs of conductance quantization. We attribute this to Coulomb blockade resulting from barriers formed at the spacer-gate interfaces. We show that at high bias transport occurs thermionically over the highest barrier: Transconductance traces obtained from microwave scattering-parameter measurements at liquid helium and room temperature is accurately fitted by a thermionic model. From the fits we deduce the ratio of gate capacitance and quantum capacitance, as well as the electron temperature.
△ Less
Submitted 10 December, 2013;
originally announced December 2013.
-
Supercollision cooling in undoped graphene
Authors:
A. C. Betz,
S. H. Jhang,
E. Pallecchi,
R. Feirrera,
G. Fève,
J. -M. Berroir,
B. Plaçais
Abstract:
Carrier mobility in solids is generally limited by electron-impurity or electron-phonon scattering depending on the most frequently occurring event. Three body collisions between carriers and both phonons and impurities are rare; they are denoted supercollisions (SCs). Elusive in electronic transport they should emerge in relaxation processes as they allow for large energy transfers. As pointed ou…
▽ More
Carrier mobility in solids is generally limited by electron-impurity or electron-phonon scattering depending on the most frequently occurring event. Three body collisions between carriers and both phonons and impurities are rare; they are denoted supercollisions (SCs). Elusive in electronic transport they should emerge in relaxation processes as they allow for large energy transfers. As pointed out in Ref. \onlinecite{Song2012PRL}, this is the case in undoped graphene where the small Fermi surface drastically restricts the allowed phonon energy in ordinary collisions. Using electrical heating and sensitive noise thermometry we report on SC-cooling in diffusive monolayer graphene. At low carrier density and high phonon temperature the Joule power $P$ obeys a $P\propto T_e^3$ law as a function of electronic temperature $T_e$. It overrules the linear law expected for ordinary collisions which has recently been observed in resistivity measurements. The cubic law is characteristic of SCs and departs from the $T_e^4$ dependence recently reported for metallic graphene below the Bloch-Grüneisen temperature. These supercollisions are important for applications of graphene in bolometry and photo-detection.
△ Less
Submitted 25 October, 2012;
originally announced October 2012.
-
Hot electron cooling by acoustic phonons in graphene
Authors:
A. C. Betz,
F. Vialla,
D. Brunel,
C. Voisin,
M. Picher,
A. Cavanna,
A. Madouri,
G. Fève,
J. -M. Berroir,
B. Plaçais,
E. Pallecchi
Abstract:
We have investigated the energy loss of hot electrons in metallic graphene by means of GHz noise thermometry at liquid helium temperature. We observe the electronic temperature T / V at low bias in agreement with the heat diffusion to the leads described by the Wiedemann-Franz law. We report on $T\propto\sqrt{V}$ behavior at high bias, which corresponds to a T4 dependence of the cooling power. Thi…
▽ More
We have investigated the energy loss of hot electrons in metallic graphene by means of GHz noise thermometry at liquid helium temperature. We observe the electronic temperature T / V at low bias in agreement with the heat diffusion to the leads described by the Wiedemann-Franz law. We report on $T\propto\sqrt{V}$ behavior at high bias, which corresponds to a T4 dependence of the cooling power. This is the signature of a 2D acoustic phonon cooling mechanism. From a heat equation analysis of the two regimes we extract accurate values of the electron-acoustic phonon coupling constant $Σ$ in monolayer graphene. Our measurements point to an important effect of lattice disorder in the reduction of $Σ$, not yet considered by theory. Moreover, our study provides a strong and firm support to the rising field of graphene bolometric detectors.
△ Less
Submitted 11 August, 2012; v1 submitted 13 March, 2012;
originally announced March 2012.
-
Graphene microwave transistors on sapphire substrates
Authors:
E. Pallecchi,
C. Benz,
A. C. Betz,
H. v. Löhneysen,
B. Plaçais,
R. Danneau
Abstract:
We have developed metal-oxide graphene field-effect transistors (MOGFETs) on sapphire substrates working at microwave frequencies. For monolayers, we obtain a transit frequency up to ~ 80 GHz for a gate length of 200 nm, and a power gain maximum frequency of about ~ 3 GHz for this specific sample. Given the strongly reduced charge noise for nanostructures on sapphire, the high stability and high p…
▽ More
We have developed metal-oxide graphene field-effect transistors (MOGFETs) on sapphire substrates working at microwave frequencies. For monolayers, we obtain a transit frequency up to ~ 80 GHz for a gate length of 200 nm, and a power gain maximum frequency of about ~ 3 GHz for this specific sample. Given the strongly reduced charge noise for nanostructures on sapphire, the high stability and high performance of this material at low temperature, our MOGFETs on sapphire are well suited for a cryogenic broadband low-noise amplifier.
△ Less
Submitted 27 June, 2011;
originally announced June 2011.
-
Transport scattering time probed through rf admittance of a graphene capacitor
Authors:
E. Pallecchi,
A. C. Betz,
J. Chaste,
G. Fève,
B. Huard,
T. Kontos,
J. -M. Berroir,
B. Plaçais
Abstract:
We have investigated electron dynamics in top gated graphene by measuring the gate admittance of a diffusive graphene capacitor in a broad frequency range as a function of carrier density. The density of states, conductivity and diffusion constant are deduced from the low frequency gate capacitance, its charging time and their ratio. The admittance evolves from an RC-like to a skin-effect response…
▽ More
We have investigated electron dynamics in top gated graphene by measuring the gate admittance of a diffusive graphene capacitor in a broad frequency range as a function of carrier density. The density of states, conductivity and diffusion constant are deduced from the low frequency gate capacitance, its charging time and their ratio. The admittance evolves from an RC-like to a skin-effect response at GHz frequency with a crossover given by the Thouless energy. The scattering time is found to be independent of energy in the 0 - 200 meV investigated range at room temperature. This is consistent with a random mass model for Dirac Fermions.
△ Less
Submitted 23 March, 2011; v1 submitted 19 May, 2010;
originally announced May 2010.
-
Authoring case based training by document data extraction
Authors:
Christian Betz,
Alexander Hoernlein,
Frank Puppe
Abstract:
In this paper, we propose an scalable approach to modeling based upon word processing documents, and we describe the tool Phoenix providing the technical infrastructure.
For our training environment d3web.Train, we developed a tool to extract case knowledge from existing documents, usually dismissal records, extending Phoenix to d3web.CaseImporter. Independent authors used this tool to develop…
▽ More
In this paper, we propose an scalable approach to modeling based upon word processing documents, and we describe the tool Phoenix providing the technical infrastructure.
For our training environment d3web.Train, we developed a tool to extract case knowledge from existing documents, usually dismissal records, extending Phoenix to d3web.CaseImporter. Independent authors used this tool to develop training systems, observing a significant decrease of time for setteling-in and a decrease of time necessary for develo** a case.
△ Less
Submitted 14 September, 2005;
originally announced September 2005.