-
Measurement of the neutrino velocity with the ICARUS detector at the CNGS beam
Authors:
M. Antonello,
P. Aprili,
B. Baibussinov,
M. Baldo Ceolin,
P. Benetti,
E. Calligarich,
N. Canci,
F. Carbonara,
S. Centro,
A. Cesana,
K. Cieslik,
D. B. Cline,
A. G. Cocco,
A. Dabrowska,
D. Dequal,
A. Dermenev,
R. Dolfini,
C. Farnese,
A. Fava,
A. Ferrari,
G. Fiorillo,
D. Gibin,
A. Gigli Berzolari,
S. Gninenko,
A. Guglielmi
, et al. (40 additional authors not shown)
Abstract:
The CERN-SPS accelerator has been briefly operated in a new, lower intensity neutrino mode with ~10^12 p.o.t. /pulse and with a beam structure made of four LHC-like extractions, each with a narrow width of 3 ns, separated by 524 ns. This very tightly bunched beam structure represents a substantial progress with respect to the ordinary operation of the CNGS beam, since it allows a very accurate tim…
▽ More
The CERN-SPS accelerator has been briefly operated in a new, lower intensity neutrino mode with ~10^12 p.o.t. /pulse and with a beam structure made of four LHC-like extractions, each with a narrow width of 3 ns, separated by 524 ns. This very tightly bunched beam structure represents a substantial progress with respect to the ordinary operation of the CNGS beam, since it allows a very accurate time-of-flight measurement of neutrinos from CERN to LNGS on an event-to-event basis. The ICARUS T600 detector has collected 7 beam-associated events, consistent with the CNGS delivered neutrino flux of 2.2 10^16 p.o.t. and in agreement with the well known characteristics of neutrino events in the LAr-TPC. The time of flight difference between the speed of light and the arriving neutrino LAr-TPC events has been analysed. The result is compatible with the simultaneous arrival of all events with equal speed, the one of light. This is in a striking difference with the reported result of OPERA that claimed that high energy neutrinos from CERN should arrive at LNGS about 60 ns earlier than expected from luminal speed.
△ Less
Submitted 29 March, 2012; v1 submitted 15 March, 2012;
originally announced March 2012.
-
A search for the analogue to Cherenkov radiation by high energy neutrinos at superluminal speeds in ICARUS
Authors:
ICARUS Collaboration,
M. Antonello,
P. Aprili,
B. Baibussinov,
M. Baldo Ceolin,
P. Benetti,
E. Calligarich,
N. Canci,
F. Carbonara,
S. Centro,
A. Cesana,
K. Cieslik,
D. B. Cline,
A. G. Cocco,
A. Cohen,
A. Dabrowska,
D. Dequal,
A. Dermenev,
R. Dolfini,
C. Farnese,
A. Fava,
A. Ferrari,
G. Fiorillo,
D. Gibin,
A. Gigli Berzolari
, et al. (40 additional authors not shown)
Abstract:
The OPERA collaboration has claimed evidence of superluminal ν{_μ} propagation between CERN and the LNGS. Cohen and Glashow argued that such neutrinos should lose energy by producing photons and e+e- pairs, through Z0 mediated processes analogous to Cherenkov radiation. In terms of the parameter delta=(v^2_nu-v^2_c)/v^2_c, the OPERA result implies delta = 5 x 10^-5. For this value of δa very signi…
▽ More
The OPERA collaboration has claimed evidence of superluminal ν{_μ} propagation between CERN and the LNGS. Cohen and Glashow argued that such neutrinos should lose energy by producing photons and e+e- pairs, through Z0 mediated processes analogous to Cherenkov radiation. In terms of the parameter delta=(v^2_nu-v^2_c)/v^2_c, the OPERA result implies delta = 5 x 10^-5. For this value of δa very significant deformation of the neutrino energy spectrum and an abundant production of photons and e+e- pairs should be observed at LNGS. We present an analysis based on the 2010 and part of the 2011 data sets from the ICARUS experiment, located at Gran Sasso National Laboratory and using the same neutrino beam from CERN. We find that the rates and deposited energy distributions of neutrino events in ICARUS agree with the expectations for an unperturbed spectrum of the CERN neutrino beam. Our results therefore refute a superluminal interpretation of the OPERA result according to the Cohen and Glashow prediction for a weak current analog to Cherenkov radiation. In particular no superluminal Cherenkov like e+e- pair or gamma emission event has been directly observed inside the fiducial volume of the "bubble chamber like" ICARUS TPC-LAr detector, setting the much stricter limit of delta < 2.5 10^-8 at the 90% confidence level, comparable with the one due to the observations from the SN1987A.
△ Less
Submitted 8 March, 2012; v1 submitted 17 October, 2011;
originally announced October 2011.
-
Underground operation of the ICARUS T600 LAr-TPC: first results
Authors:
C. Rubbia,
M. Antonello,
P. Aprili,
B. Baibussinov,
M. Baldo Ceolin,
L. Barzè,
P. Benetti,
E. Calligarich,
N. Canci,
F. Carbonara,
F. Cavanna,
S. Centro,
A. Cesana,
K. Cieslik,
D. B. Cline,
A. G. Cocco,
A. Dabrowska,
D. Dequal,
A. Dermenev,
R. Dolfini,
C. Farnese,
A. Fava,
A. Ferrari,
G. Fiorillo,
D. Gibin
, et al. (52 additional authors not shown)
Abstract:
Open questions are still present in fundamental Physics and Cosmology, like the nature of Dark Matter, the matter-antimatter asymmetry and the validity of the particle interaction Standard Model. Addressing these questions requires a new generation of massive particle detectors exploring the subatomic and astrophysical worlds. ICARUS T600 is the first large mass (760 ton) example of a novel detect…
▽ More
Open questions are still present in fundamental Physics and Cosmology, like the nature of Dark Matter, the matter-antimatter asymmetry and the validity of the particle interaction Standard Model. Addressing these questions requires a new generation of massive particle detectors exploring the subatomic and astrophysical worlds. ICARUS T600 is the first large mass (760 ton) example of a novel detector generation able to combine the imaging capabilities of the old famous "bubble chamber" with an excellent energy measurement in huge electronic detectors. ICARUS T600 now operates at the Gran Sasso underground laboratory, studying cosmic rays, neutrino oscillation and proton decay. Physical potentialities of this novel telescope are presented through few examples of neutrino interactions reconstructed with unprecedented details. Detector design and early operation are also reported.
△ Less
Submitted 7 June, 2011; v1 submitted 6 June, 2011;
originally announced June 2011.
-
A new, very massive modular Liquid Argon Imaging Chamber to detect low energy off-axis neutrinos from the CNGS beam. (Project MODULAr)
Authors:
B. Baibussinov,
M. Baldo Ceolin,
G. Battistoni,
P. Benetti,
A. Borio,
E. Calligarich,
M. Cambiaghi,
F. Cavanna,
S. Centro,
A. G. Cocco,
R. Dolfini,
A. Gigli Berzolari,
C. Farnese,
A. Fava,
A. Ferrari,
G. Fiorillo,
D. Gibin,
A. Guglielmi,
G. Mannocchi,
F. Mauri,
A. Menegolli,
G. Meng,
C. Montanari,
O. Palamara,
L. Periale
, et al. (11 additional authors not shown)
Abstract:
The paper is considering an opportunity for the CERN/GranSasso (CNGS) neutrino complex, concurrent time-wise with T2K and NOvA, to search for theta_13 oscillations and CP violation. Compared with large water Cherenkov (T2K) and fine grained scintillators (NOvA), the LAr-TPC offers a higher detection efficiency and a lower backgrounds, since virtually all channels may be unambiguously recognized.…
▽ More
The paper is considering an opportunity for the CERN/GranSasso (CNGS) neutrino complex, concurrent time-wise with T2K and NOvA, to search for theta_13 oscillations and CP violation. Compared with large water Cherenkov (T2K) and fine grained scintillators (NOvA), the LAr-TPC offers a higher detection efficiency and a lower backgrounds, since virtually all channels may be unambiguously recognized. The present proposal, called MODULAr, describes a 20 kt fiducial volume LAr-TPC, following very closely the technology developed for the ICARUS-T60o, and is focused on the following activities, for which we seek an extended international collaboration:
(1) the neutrino beam from the CERN 400 GeV proton beam and an optimised horn focussing, eventually with an increased intensity in the framework of the LHC accelerator improvement program;
(2) A new experimental area LNGS-B, of at least 50000 m3 at 10 km off-axis from the main Laboratory, eventually upgradable to larger sizes. A location is under consideration at about 1.2 km equivalent water depth;
(3) A new LAr Imaging detector of at least 20 kt fiducial mass. Such an increase in the volume over the current ICARUS T600 needs to be carefully considered. It is concluded that a very large mass is best realised with a set of many identical, independent units, each of 5 kt, "cloning" the technology of the T600. Further phases may foresee extensions of MODULAr to meet future physics goals.
The experiment might reasonably be operational in about 4/5 years, provided a new hall is excavated in the vicinity of the Gran Sasso Laboratory and adequate funding and participation are made available.
△ Less
Submitted 11 April, 2007;
originally announced April 2007.