-
Data-Driven Invertible Neural Surrogates of Atmospheric Transmission
Authors:
James Koch,
Brenda Forland,
Bruce Bernacki,
Timothy Doster,
Tegan Emerson
Abstract:
We present a framework for inferring an atmospheric transmission profile from a spectral scene. This framework leverages a lightweight, physics-based simulator that is automatically tuned - by virtue of autodifferentiation and differentiable programming - to construct a surrogate atmospheric profile to model the observed data. We demonstrate utility of the methodology by (i) performing atmospheric…
▽ More
We present a framework for inferring an atmospheric transmission profile from a spectral scene. This framework leverages a lightweight, physics-based simulator that is automatically tuned - by virtue of autodifferentiation and differentiable programming - to construct a surrogate atmospheric profile to model the observed data. We demonstrate utility of the methodology by (i) performing atmospheric correction, (ii) recasting spectral data between various modalities (e.g. radiance and reflectance at the surface and at the sensor), and (iii) inferring atmospheric transmission profiles, such as absorbing bands and their relative magnitudes.
△ Less
Submitted 30 April, 2024;
originally announced April 2024.
-
Development of a low background liquid scintillation counter for a shallow underground laboratory
Authors:
J. L. Erchinger,
C. E. Aalseth,
B. E. Bernacki,
M. Douglas,
E. S. Fuller,
M. E. Keillor,
S. M. Morley,
C. A. Mullen,
J. L. Orrell,
M. E. Panisko,
G. A. Warren,
R. O. Williams,
M. E. Wright
Abstract:
Pacific Northwest National Laboratory has recently opened a shallow underground laboratory intended for measurement of low-concentration levels of radioactive isotopes in samples collected from the environment. The development of a low-background liquid scintillation counter is currently underway to further augment the measurement capabilities within this underground laboratory. Liquid scintillati…
▽ More
Pacific Northwest National Laboratory has recently opened a shallow underground laboratory intended for measurement of low-concentration levels of radioactive isotopes in samples collected from the environment. The development of a low-background liquid scintillation counter is currently underway to further augment the measurement capabilities within this underground laboratory. Liquid scintillation counting is especially useful for measuring charged particle (e.g., $β$, $α$) emitting isotopes with no (or very weak) gamma-ray yields. The combination of high-efficiency detection of charged particle emission in a liquid scintillation cocktail coupled with the low-background environment of an appropriately-designed shield located in a clean underground laboratory provides the opportunity for increased-sensitivity measurements of a range of isotopes. To take advantage of the 35 meters-water-equivalent overburden of the underground laboratory, a series of simulations have evaluated the scintillation counter's shield design requirements to assess the possible background rate achievable. This report presents the design and background evaluation for a shallow underground, low background liquid scintillation counter design for sample measurements.
△ Less
Submitted 20 December, 2015;
originally announced December 2015.
-
Advances in the Development of Mid-Infrared Integrated Devices for Interferometric Arrays
Authors:
L. Labadie,
Guillermo Martin,
Airan Rodenas,
Norman C. Anheier,
Brahim Arezki,
Robert R. Thomson,
Hong A. Qiao,
Pierre Kern,
Ajoy K. Kar,
Bruce E. Bernacki
Abstract:
This article reports the advances on the development of mid-infrared integrated optics for stellar interferometry. The devices are fabricated by laser writing techniques on chalcogenide glasses. Laboratory characterizaton is reported and analyzed.
This article reports the advances on the development of mid-infrared integrated optics for stellar interferometry. The devices are fabricated by laser writing techniques on chalcogenide glasses. Laboratory characterizaton is reported and analyzed.
△ Less
Submitted 19 July, 2012;
originally announced July 2012.
-
First fringes with an integrated-optics beam combiner at 10 um - A new step towards instrument miniaturization for mid-infrared interferometry
Authors:
Lucas Labadie,
Guillermo Martin,
Norman C. Anheier,
Brahim Arezki,
H. A. Qiao,
Bruce Bernacki,
Pierre Kern
Abstract:
Observations at mas-resolution scales and high dynamic range hold a central place in achieving, for instance, the spectroscopic characterization of exo-Earths or the detailed map** of their protoplanetary disc birthplace. Ground or space-based multi-aperture infrared interferometry is a promising technique to tackle these goals. But significant efforts still need to be undertaken to achieve a si…
▽ More
Observations at mas-resolution scales and high dynamic range hold a central place in achieving, for instance, the spectroscopic characterization of exo-Earths or the detailed map** of their protoplanetary disc birthplace. Ground or space-based multi-aperture infrared interferometry is a promising technique to tackle these goals. But significant efforts still need to be undertaken to achieve a simplification of these instruments if we want to combine the light from a large number of telescopes. Integrated-optics appears as an alternative to the current conventional designs, especially if its use can be extended to a higher number of astronomical bands. This article reports for the first time the experimental demonstration of the feasibility of an integrated-optics approach to mid-infrared beam combination for single-mode stellar interferometry. We have fabricated a 2-telescope beam combiner prototype integrated on a substrate of chalcogenide glasses, a material transparent from 1 to 14 um. We have developed laboratory tools to characterize the modal properties and the interferometric capabilities of our device. We obtain fringes at 10 um and measure a mean contrast V=0.981 \pm 0.001 with high repeatability over one week and high stability over 5h. We show experimentally - as well as on the basis of modeling considerations - that the component has a single-mode behavior at this wavelength, which is essential to achieve high-accuracy interferometry. From previous studies, the propagation losses are estimated to 0.5 dB/cm for such components. We also discuss possible issues that may impact the interferometric contrast. The IO beam combiner performs well at 10. We also anticipate the requirement of a better matching between the numerical apertures of the component and the (de)coupling optics to optimize the total throughput. The next step foreseen is the achievement of wide-band interferograms.
△ Less
Submitted 14 April, 2011;
originally announced April 2011.