Drift Observations and Mitigation in LCLS-II RF
Authors:
L. Doolittle,
S. D. Murthy,
A. Benwell,
D. Chabot,
J. Chen,
B. Hong,
S. Hoobler,
J. Nelson,
C. Xu
Abstract:
The LCLS-II RF system physically spans ~700m and has strict requirements -- on the order of 20 fs -- on the phase stability of the accelerating RF fields in its SRF linac. While each LLRF rack is crudely temperature-stabilized, the weather inside the service building as a whole is usually compared to a tin shack in the California sun. A phase-averaging reference line is the primary system deployed…
▽ More
The LCLS-II RF system physically spans ~700m and has strict requirements -- on the order of 20 fs -- on the phase stability of the accelerating RF fields in its SRF linac. While each LLRF rack is crudely temperature-stabilized, the weather inside the service building as a whole is usually compared to a tin shack in the California sun. A phase-averaging reference line is the primary system deployed in support of the phase stability goals. There are other, secondary subsystems (SEL phase offset, and determination of cavity detuning) that are also sensitive to RF phase drift. We present measurements of phase shifts observed in the overall RF system, and how diagnostics are able to sense and correct for them during beam operations.
△ Less
Submitted 14 November, 2023; v1 submitted 25 October, 2023;
originally announced October 2023.
-
Installation, Commissioning and Performance of Phase Reference Line for LCLS-II
Authors:
Shreeharshini Dharanesh Murthy,
Lawrence Doolittle,
Charlie Xu,
Bo Hong,
Andrew Benwell,
**g Chen
Abstract:
Any cavity controller for a distributed system needs a Phase Reference Line (PRL) signal from which to define phases of a cavity field measurement. The LCLS-II PRL system at SLAC provides bidirectional (forward and reverse) phase references at 1300 MHz to each rack of the LLRF system. The PRL controller embedded with the Master Oscillator (MO) locks the average phase of the two directions to the M…
▽ More
Any cavity controller for a distributed system needs a Phase Reference Line (PRL) signal from which to define phases of a cavity field measurement. The LCLS-II PRL system at SLAC provides bidirectional (forward and reverse) phase references at 1300 MHz to each rack of the LLRF system. The PRL controller embedded with the Master Oscillator (MO) locks the average phase of the two directions to the MO itself. Phase-averaging tracking loop is applied in firmware which supports the feature of cancelling the phase drift caused by changes in PRL cable length. FPGA logic moves the phase of digital LO to get zero average phase of the two PRL signals. This same LO is used for processing cavity pickup signals, thus establishing a stable reference phase for critical cavity RF measurements. At low frequencies, open-loop PRL noise relative to the LO distribution includes a strong environment and 1/f components, but the closed-loop noise approaches the noise floor of the DSP. The implication is that the close-in phase noise of the cavities will be dominated by the chassis DAQ noise. The final out-of-loop phase noise relevant to machine operations is that of the cavity field relative to the beam.
△ Less
Submitted 15 October, 2022; v1 submitted 11 October, 2022;
originally announced October 2022.
-
Analog Cavity Emulators to Support LLRF Development
Authors:
Shreeharshini Dharanesh Murthy,
Lawrence Doolittle,
Andrew Benwell
Abstract:
The goal of a LLRF system is to control an actual RF cavity with beam. While digital simulations have a place, having an analog circuit to stand in for the cavity can be tremendously helpful in validating hardware+firmware+software under development. A wide range of cavity emulators have been developed in collaboration with SLAC, and LBNL. Cavity emulators are typically based on quartz crystals an…
▽ More
The goal of a LLRF system is to control an actual RF cavity with beam. While digital simulations have a place, having an analog circuit to stand in for the cavity can be tremendously helpful in validating hardware+firmware+software under development. A wide range of cavity emulators have been developed in collaboration with SLAC, and LBNL. Cavity emulators are typically based on quartz crystals and frequency conversion hardware. The choice of crystal frequency and coupling mechanism depends in part on the bandwidth and coupling of the cavity it's intended to emulate. Examples of bandwidth range from 800 Hz (SLAC) as a stand-in for a SRF cavity, to 31 kHz (LBNL) for a room-temperature accumulator ring cavity. An external LO is used to tune the emulated cavity frequency. The coupling properties are also of interest if the scope includes emulating reverse power waveforms. LLRF system checks such as closed-loop bandwidth, and determining cavity detuning can be performed interactively and as part of a Continuous Integration (CI) process. This paper describes the design, implementation, and performance of the cavity emulators.
△ Less
Submitted 15 October, 2022; v1 submitted 11 October, 2022;
originally announced October 2022.
-
The LCLS-II Gun & Buncher LLRF Controller Upgrade
Authors:
Christos Bakalis,
Andrew Benwell,
Daron Chabot,
Lawrence Doolittle,
John Dusatko,
Daniele Filippetto,
Gang Huang,
Sergio Paiagua,
Carlos Serrano
Abstract:
LCLS-II is currently in its commissioning phase at SLAC. It is an X-ray FEL driven by a CW superconducting LINAC. The beam injector plays a crucial role in the overall performance of the accelerator, and is critical to the final electron beam performance parameters. The LCLS-II injector comprises of a 185.7 MHz VHF copper gun cavity, and a 1.3 GHz two-cell L-band copper buncher cavity. The FPGA-ba…
▽ More
LCLS-II is currently in its commissioning phase at SLAC. It is an X-ray FEL driven by a CW superconducting LINAC. The beam injector plays a crucial role in the overall performance of the accelerator, and is critical to the final electron beam performance parameters. The LCLS-II injector comprises of a 185.7 MHz VHF copper gun cavity, and a 1.3 GHz two-cell L-band copper buncher cavity. The FPGA-based controller employs feedback and Self-Excited Loop logic in order to regulate the cavity fields. It also features several other functionalities, such as live detune computation, active frequency tracking, and waveform recording. The LLRF system drives the cavities via two 60 kW SSAs through two power couplers, and thus stabilizes the fields inside the plant. This paper provides an outline of the general functionalities of the system, alongside a description of its hardware, firmware and software architecture, before finalizing with the current status of the project and its future goals.
△ Less
Submitted 8 November, 2022; v1 submitted 8 October, 2022;
originally announced October 2022.
-
Narrow bandwidth active noise control for microphonics rejection in superconducting cavities at LCLS-II
Authors:
Andrea Bellandi,
Julien Branlard,
Jorge Diaz Cruz,
Sebastian Aderhold,
Andrew Benwell,
Axel Brachmann,
Sonya Hoobler,
Alessandro Ratti,
Dan Gonnella,
Janice Nelson,
Ryan Douglas Porter,
Lisa Zacarias
Abstract:
LCLS-II is an X-Ray Free Electron Laser (XFEL) commissioned in 2022, being the first Continuous Wave (CW) hard XFEL in the world to come into operation. To accelerate the electron beam to an energy of $\SI{4}{\giga \eV}$, 280 TESLA type superconducting RF (SRF) cavities are used. A loaded quality factor ($Q_L$) of $4 \times 10^7$ is used to drive the cavities at a power level of a few kilowatts. F…
▽ More
LCLS-II is an X-Ray Free Electron Laser (XFEL) commissioned in 2022, being the first Continuous Wave (CW) hard XFEL in the world to come into operation. To accelerate the electron beam to an energy of $\SI{4}{\giga \eV}$, 280 TESLA type superconducting RF (SRF) cavities are used. A loaded quality factor ($Q_L$) of $4 \times 10^7$ is used to drive the cavities at a power level of a few kilowatts. For this $Q_L$, the RF cavity bandwidth is 32 Hz. Therefore, kee** the cavity resonance frequency within such bandwidth is imperative to avoid a significant increase in the required drive power. In superconducting accelerators, resonance frequency variations are produced by mechanical microphonic vibrations of the cavities. One source of microphonic noise is rotary machinery such as vacuum pumps or HVAC equipment. A possible method to reject these disturbances is to use Narrowband Active Noise Control (NANC) techniques. These techniques were already tested at DESY/CMTB and Cornell/CBETA. This proceeding presents the implementation of a NANC controller adapted to the LCLS-II Low Level RF (LLRF) control system. Tests showing the rejection of LCLS-II microphonic disturbances are also presented.
△ Less
Submitted 11 October, 2022; v1 submitted 28 September, 2022;
originally announced September 2022.
-
LCLS-II-HE verification cryomodule high gradient performance and quench behavior
Authors:
S. Posen,
A. Cravatta,
M. Checchin,
S. Aderhold,
C. Adolphsen,
T. Arkan,
D. Bafia,
A. Benwell,
D. Bice,
B. Chase,
C. Contreras-Martinez,
L. Dootlittle,
J. Fuerst,
D. Gonnella,
A. Grassellino,
C. Grimm,
B. Hansen,
E. Harms,
B. Hartsell,
G. Hays,
J. Holzbauer,
S. Hoobler,
J. Kaluzny,
T. Khabiboulline,
M. Kucera
, et al. (21 additional authors not shown)
Abstract:
An 8-cavity, 1.3 GHz, LCLS-II-HE cryomodule was assembled and tested at Fermilab to verify performance before the start of production. Its cavities were processed with a novel nitrogen do** treatment to improve gradient performance. The cryomodule was tested with a modified protocol to process sporadic quenches, which were observed in LCLS-II production cryomodules and are attributed to multipac…
▽ More
An 8-cavity, 1.3 GHz, LCLS-II-HE cryomodule was assembled and tested at Fermilab to verify performance before the start of production. Its cavities were processed with a novel nitrogen do** treatment to improve gradient performance. The cryomodule was tested with a modified protocol to process sporadic quenches, which were observed in LCLS-II production cryomodules and are attributed to multipacting. Dedicated vertical test experiments support the attribution to multipacting. The verification cryomodule achieved an acceleration voltage of 200 MV in continuous wave mode, corresponding to an average accelerating gradient of 24.1 MV/m, significantly exceeding the specification of 173 MV. The average Q0 (3.0x10^10) also exceeded its specification (2.7x10^10). After processing, no field emission was observed up to the maximum gradient of each cavity. This paper reviews the cryomodule performance and discusses operational issues and mitigations implemented during the several month program.
△ Less
Submitted 27 October, 2021;
originally announced October 2021.