-
The EXO-200 detector, part II: Auxiliary Systems
Authors:
N. Ackerman,
J. Albert,
M. Auger,
D. J. Auty,
I. Badhrees,
P. S. Barbeau,
L. Bartoszek,
E. Baussan,
V. Belov,
C. Benitez-Medina,
T. Bhatta,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
R. Conley,
S. Cook,
M. Coon,
W. Craddock,
A. Craycraft,
W. Cree,
T. Daniels,
L. Darroch
, et al. (135 additional authors not shown)
Abstract:
The EXO-200 experiment searched for neutrinoless double-beta decay of $^{136}$Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber with ionization and scintillation detection and readout. This paper describes the design and performance of the various support systems necessary for detector op…
▽ More
The EXO-200 experiment searched for neutrinoless double-beta decay of $^{136}$Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber with ionization and scintillation detection and readout. This paper describes the design and performance of the various support systems necessary for detector operation, including cryogenics, xenon handling, and controls. Novel features of the system were driven by the need to protect the thin-walled detector chamber containing the liquid xenon, to achieve high chemical purity of the Xe, and to maintain thermal uniformity across the detector.
△ Less
Submitted 22 October, 2021; v1 submitted 13 July, 2021;
originally announced July 2021.
-
Investigation of radioactivity-induced backgrounds in EXO-200
Authors:
J. B. Albert,
D. J. Auty,
P. S. Barbeau,
D. Beck,
V. Belov,
C. Benitez-Medina,
M. Breidenbach,
T. Brunner,
A. Burenkov,
G. F. Cao,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
T. Daniels,
M. Danilov,
S. J. Daugherty,
C. G. Davis,
J. Davis,
S. Delaquis,
A. Der Mesrobian-Kabakian,
R. DeVoe,
T. Didberidze,
A. Dolgolenko,
M. J. Dolinski
, et al. (61 additional authors not shown)
Abstract:
The search for neutrinoless double-beta decay (0νββ) requires extremely low background and a good understanding of their sources and their influence on the rate in the region of parameter space relevant to the 0νββ signal. We report on studies of various β- and γ-backgrounds in the liquid- xenon-based EXO-200 0νββ experiment. With this work we try to better understand the location and strength of…
▽ More
The search for neutrinoless double-beta decay (0νββ) requires extremely low background and a good understanding of their sources and their influence on the rate in the region of parameter space relevant to the 0νββ signal. We report on studies of various β- and γ-backgrounds in the liquid- xenon-based EXO-200 0νββ experiment. With this work we try to better understand the location and strength of specific background sources and compare the conclusions to radioassay results taken before and during detector construction. Finally, we discuss the implications of these studies for EXO-200 as well as for the next-generation, tonne-scale nEXO detector.
△ Less
Submitted 16 July, 2015; v1 submitted 20 March, 2015;
originally announced March 2015.
-
An RF-only ion-funnel for extraction from high-pressure gases
Authors:
Thomas Brunner,
Daniel Fudenberg,
Victor Varentsov,
Amanda Sabourov,
Giorgio Gratta,
Jens Dilling,
Ralph DeVoe,
David Sinclair,
William Fairbank Jr.,
Joshua B Albert,
David J Auty,
Phil S Barbeau,
Douglas Beck,
Cesar Benitez-Medina,
Martin Breidenbach,
Guofu F Cao,
Christopher Chambers,
Bruce Cleveland,
Matthew Coon,
Adam Craycraft,
Timothy Daniels,
Sean J Daugherty,
Tamar Didberidze,
Michelle J Dolinski,
Matthew Dunford
, et al. (52 additional authors not shown)
Abstract:
An RF ion-funnel technique has been developed to extract ions from a high-pressure (10 bar) noble-gas environment into vacuum ($10^{-6}$ mbar). Detailed simulations have been performed and a prototype has been developed for the purpose of extracting $^{136}$Ba ions from Xe gas with high efficiency. With this prototype, ions have been extracted for the first time from high-pressure xenon gas and ar…
▽ More
An RF ion-funnel technique has been developed to extract ions from a high-pressure (10 bar) noble-gas environment into vacuum ($10^{-6}$ mbar). Detailed simulations have been performed and a prototype has been developed for the purpose of extracting $^{136}$Ba ions from Xe gas with high efficiency. With this prototype, ions have been extracted for the first time from high-pressure xenon gas and argon gas. Systematic studies have been carried out and compared to the simulations. This demonstration of extraction of ions with mass comparable to that of the gas generating the high-pressure into vacuum has applications to Ba tagging from a Xe-gas time-projection chamber (TPC) for double beta decay as well as to the general problem of recovering trace amounts of an ionized element in a heavy (m$>40$ u) carrier gas.
△ Less
Submitted 22 March, 2017; v1 submitted 2 December, 2014;
originally announced December 2014.
-
Spectroscopy of Ba and Ba$^+$ deposits in solid xenon for barium tagging in nEXO
Authors:
B. Mong,
S. Cook,
T. Walton,
C. Chambers,
A. Craycraft,
C. Benitez-Medina,
K. Hall,
W. Fairbank Jr.,
J. B. Albert,
D. J. Auty,
P. S. Barbeau,
V. Basque,
D. Beck,
M. Breidenbach,
T. Brunner,
G. F. Cao,
B. Cleveland,
M. Coon,
T. Daniels,
S. J. Daugherty,
R. DeVoe,
T. Didberidze,
J. Dilling,
M. J. Dolinski,
M. Dunford
, et al. (51 additional authors not shown)
Abstract:
Progress on a method of barium tagging for the nEXO double beta decay experiment is reported. Absorption and emission spectra for deposits of barium atoms and ions in solid xenon matrices are presented. Excitation spectra for prominent emission lines, temperature dependence and bleaching of the fluorescence reveal the existence of different matrix sites. A regular series of sharp lines observed in…
▽ More
Progress on a method of barium tagging for the nEXO double beta decay experiment is reported. Absorption and emission spectra for deposits of barium atoms and ions in solid xenon matrices are presented. Excitation spectra for prominent emission lines, temperature dependence and bleaching of the fluorescence reveal the existence of different matrix sites. A regular series of sharp lines observed in Ba$^+$ deposits is identified with some type of barium hydride molecule. Lower limits for the fluorescence quantum efficiency of the principal Ba emission transition are reported. Under current conditions, an image of $\le10^4$ Ba atoms can be obtained. Prospects for imaging single Ba atoms in solid xenon are discussed.
△ Less
Submitted 9 October, 2014;
originally announced October 2014.
-
Search for Majoron-emitting modes of double-beta decay of $^{136}$Xe with EXO-200
Authors:
EXO-200 Collaboration,
:,
J. B. Albert,
D. J. Auty,
P. S. Barbeau,
E. Beauchamp,
D. Beck,
V. Belov,
C. Benitez-Medina,
M. Breidenbach,
T. Brunner,
A. Burenkov,
G. F. Cao,
C. Chambers,
J. Chaves,
B. Cleveland,
M. Coon,
A. Craycraft,
T. Daniels,
M. Danilov,
S. J. Daugherty,
C. G. Davis,
J. Davis,
R. DeVoe,
S. Delaquis
, et al. (68 additional authors not shown)
Abstract:
EXO-200 is a single phase liquid xenon detector designed to search for neutrinoless double-beta decay of $^{136}$Xe. Here we report on a search for various Majoron-emitting modes based on 100 kg$\cdot$yr exposure of $^{136}$Xe. A lower limit of $T^{^{136}Xe}_{1/2} >1.2 \cdot 10^{24}$ yr at 90% C.L. on the half-life of the spectral index = 1 Majoron decay was obtained, corresponding to a constraint…
▽ More
EXO-200 is a single phase liquid xenon detector designed to search for neutrinoless double-beta decay of $^{136}$Xe. Here we report on a search for various Majoron-emitting modes based on 100 kg$\cdot$yr exposure of $^{136}$Xe. A lower limit of $T^{^{136}Xe}_{1/2} >1.2 \cdot 10^{24}$ yr at 90% C.L. on the half-life of the spectral index = 1 Majoron decay was obtained, corresponding to a constraint on the Majoron-neutrino coupling constant of $|< g^{M}_{ee} >|<$ (0.8-1.7)$\cdot$10$^{-5}$.
△ Less
Submitted 18 November, 2014; v1 submitted 24 September, 2014;
originally announced September 2014.
-
An apparatus to manipulate and identify individual Ba ions from bulk liquid Xe
Authors:
K. Twelker,
S. Kravitz,
M. Montero Díez,
G. Gratta,
W. Fairbank Jr.,
J. B. Albert,
D. J. Auty,
P. S. Barbeau,
D. Beck,
C. Benitez-Medina,
M. Breidenbach,
T. Brunner,
G. F. Cao,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
T. Daniels,
S. J. Daugherty,
C. G. Davis,
R. DeVoe,
S. Delaquis,
T. Didberidze,
J. Dilling,
M. J. Dolinski
, et al. (55 additional authors not shown)
Abstract:
We describe a system to transport and identify barium ions produced in liquid xenon, as part of R&D towards the second phase of a double beta decay experiment, nEXO. The goal is to identify the Ba ion resulting from an extremely rare nuclear decay of the isotope $^{136}$Xe, hence providing a confirmation of the occurrence of the decay. This is achieved through Resonance Ionization Spectroscopy (RI…
▽ More
We describe a system to transport and identify barium ions produced in liquid xenon, as part of R&D towards the second phase of a double beta decay experiment, nEXO. The goal is to identify the Ba ion resulting from an extremely rare nuclear decay of the isotope $^{136}$Xe, hence providing a confirmation of the occurrence of the decay. This is achieved through Resonance Ionization Spectroscopy (RIS). In the test setup described here, Ba ions can be produced in liquid xenon or vacuum and collected on a clean substrate. This substrate is then removed to an analysis chamber under vacuum, where laser-induced thermal desorption and RIS are used with time-of-flight (TOF) mass spectroscopy for positive identification of the barium decay product.
△ Less
Submitted 22 March, 2017; v1 submitted 2 July, 2014;
originally announced July 2014.
-
Search for Majorana neutrinos with the first two years of EXO-200 data
Authors:
EXO-200 Collaboration,
:,
J. B. Albert,
D. J. Auty,
P. S. Barbeau,
E. Beauchamp,
D. Beck,
V. Belov,
C. Benitez-Medina,
J. Bonatt,
M. Breidenbach,
T. Brunner,
A. Burenkov,
G. F. Cao,
C. Chambers,
J. Chaves,
B. Cleveland,
M. Coon,
A. Craycraft,
T. Daniels,
M. Danilov,
S. J. Daugherty,
C. G. Davis,
J. Davis,
R. DeVoe
, et al. (70 additional authors not shown)
Abstract:
Many extensions of the Standard Model of particle physics suggest that neutrinos should be Majorana-type fermions, but this assumption is difficult to confirm. Observation of neutrinoless double-beta decay ($0νββ$), a spontaneous transition that may occur in several candidate nuclei, would verify the Majorana nature of the neutrino and constrain the absolute scale of the neutrino mass spectrum. Re…
▽ More
Many extensions of the Standard Model of particle physics suggest that neutrinos should be Majorana-type fermions, but this assumption is difficult to confirm. Observation of neutrinoless double-beta decay ($0νββ$), a spontaneous transition that may occur in several candidate nuclei, would verify the Majorana nature of the neutrino and constrain the absolute scale of the neutrino mass spectrum. Recent searches carried out with $^{76}$Ge (GERDA experiment) and $^{136}$Xe (KamLAND-Zen and EXO-200 experiments) have established the lifetime of this decay to be longer than $10^{25}$ yr, corresponding to a limit on the neutrino mass of 0.2-0.4 eV. Here we report new results from EXO-200 based on 100 kg$\cdot$yr of $^{136}$Xe exposure, representing an almost fourfold increase from our earlier published datasets. We have improved the detector resolution at the $^{136}$Xe double-beta-decay Q-value to $σ$/E = 1.53% and revised the data analysis. The obtained half-life sensitivity is $1.9\cdot10^{25}$ yr, an improvement by a factor of 2.7 compared to previous EXO-200 results. We find no statistically significant evidence for $0νββ$ decay and set a half-life limit of $1.1\cdot10^{25}$ yr at 90% CL. The high sensitivity holds promise for further running of the EXO-200 detector and future $0νββ$ decay searches with nEXO.
△ Less
Submitted 4 June, 2014; v1 submitted 27 February, 2014;
originally announced February 2014.
-
An improved measurement of the 2νββ half-life of Xe-136 with EXO-200
Authors:
J. B. Albert,
M. Auger,
D. J. Auty,
P. S. Barbeau,
E. Beauchamp,
D. Beck,
V. Belov,
C. Benitez-Medina,
J. Bonatt,
M. Breidenbach,
T. Brunner,
A. Burenkov,
G. F. Cao,
C. Chambers,
J. Chaves,
B. Cleveland,
S. Cook,
T. Daniels,
M. Danilov,
S. J. Daugherty,
C. G. Davis,
J. Davis,
S. Delaquis,
R. DeVoe,
A. Dobi
, et al. (72 additional authors not shown)
Abstract:
We report on an improved measurement of the 2νββ half-life of Xe-136 performed by EXO-200. The use of a large and homogeneous time projection chamber allows for the precise estimate of the fiducial mass used for the measurement, resulting in a small systematic uncertainty. We also discuss in detail the data analysis methods used for double-beta decay searches with EXO-200, while emphasizing those…
▽ More
We report on an improved measurement of the 2νββ half-life of Xe-136 performed by EXO-200. The use of a large and homogeneous time projection chamber allows for the precise estimate of the fiducial mass used for the measurement, resulting in a small systematic uncertainty. We also discuss in detail the data analysis methods used for double-beta decay searches with EXO-200, while emphasizing those directly related to the present measurement. The Xe-136 2νββ half-life is found to be 2.165 +- 0.016 (stat) +- 0.059 (sys) x 10^21 years. This is the most precisely measured half-life of any 2νββ decay to date.
△ Less
Submitted 29 January, 2014; v1 submitted 25 June, 2013;
originally announced June 2013.
-
Search for Neutrinoless Double-Beta Decay in $^{136}$Xe with EXO-200
Authors:
M. Auger,
D. J. Auty,
P. S. Barbeau,
E. Beauchamp,
V. Belov,
C. Benitez-Medina,
M. Breidenbach,
T. Brunner,
A. Burenkov,
B. Cleveland,
S. Cook,
T. Daniels,
M. Danilov,
C. G. Davis,
S. Delaquis,
R. deVoe,
A. Dobi,
M. J. Dolinski,
A. Dolgolenko,
M. Dunford,
W. Fairbank Jr.,
J. Farine,
W. Feldmeier,
P. Fierlinger,
D. Franco
, et al. (53 additional authors not shown)
Abstract:
We report on a search for neutrinoless double-beta decay of $^{136}$Xe with EXO-200. No signal is observed for an exposure of 32.5 kg-yr, with a background of ~1.5 x 10^{-3} /(kg yr keV) in the $\pm 1σ$ region of interest. This sets a lower limit on the half-life of the neutrinoless double-beta decay $T_{1/2}^{0νββ}$($^{136}$Xe) > 1.6 x 10$^{25}$ yr (90% CL), corresponding to effective Majorana ma…
▽ More
We report on a search for neutrinoless double-beta decay of $^{136}$Xe with EXO-200. No signal is observed for an exposure of 32.5 kg-yr, with a background of ~1.5 x 10^{-3} /(kg yr keV) in the $\pm 1σ$ region of interest. This sets a lower limit on the half-life of the neutrinoless double-beta decay $T_{1/2}^{0νββ}$($^{136}$Xe) > 1.6 x 10$^{25}$ yr (90% CL), corresponding to effective Majorana masses of less than 140-380 meV, depending on the matrix element calculation.
△ Less
Submitted 20 July, 2012; v1 submitted 24 May, 2012;
originally announced May 2012.
-
The EXO-200 detector, part I: Detector design and construction
Authors:
M. Auger,
D. J. Auty,
P. S. Barbeau,
L. Bartoszek,
E. Baussan,
E. Beauchamp,
C. Benitez-Medina,
M. Breidenbach,
D. Chauhan,
B. Cleveland,
R. Conley,
J. Cook,
S. Cook,
A. Coppens,
W. Craddock,
T. Daniels,
C. G. Davis,
J. Davis,
R. deVoe,
A. Dobi,
M. J. Dolinski,
M. Dunford,
W. Fairbank Jr,
J. Farine,
P. Fierlinger
, et al. (56 additional authors not shown)
Abstract:
EXO-200 is an experiment designed to search for double beta decay of $^{136}$Xe with a single-phase, liquid xenon detector. It uses an active mass of 110 kg of xenon enriched to 80.6% in the isotope 136 in an ultra-low background time projection chamber capable of simultaneous detection of ionization and scintillation. This paper describes the EXO-200 detector with particular attention to the most…
▽ More
EXO-200 is an experiment designed to search for double beta decay of $^{136}$Xe with a single-phase, liquid xenon detector. It uses an active mass of 110 kg of xenon enriched to 80.6% in the isotope 136 in an ultra-low background time projection chamber capable of simultaneous detection of ionization and scintillation. This paper describes the EXO-200 detector with particular attention to the most innovative aspects of the design that revolve around the reduction of backgrounds, the efficient use of the expensive isotopically enriched xenon, and the optimization of the energy resolution in a relatively large volume.
△ Less
Submitted 23 May, 2012; v1 submitted 10 February, 2012;
originally announced February 2012.
-
Xenon purity analysis for EXO-200 via mass spectrometry
Authors:
A. Dobi,
C. Hall,
S. Slutsky,
Y. -R. Yen,
B. Aharmin,
M. Auger,
P. S. Barbeau,
C. Benitez-Medina,
M. Breidenbach,
B. Cleveland,
R. Conley,
J. Cook,
S. Cook,
I. Counts,
W. Craddock,
T. Daniels,
C. G. Davis,
J. Davis,
R. deVoe,
M. Dixit,
M. J. Dolinski,
K. Donato,
W. Fairbank Jr.,
J. Farine,
P. Fierlinger
, et al. (51 additional authors not shown)
Abstract:
We describe purity measurements of the natural and enriched xenon stockpiles used by the EXO-200 double beta decay experiment based on a mass spectrometry technique. The sensitivity of the spectrometer is enhanced by several orders of magnitude by the presence of a liquid nitrogen cold trap, and many impurity species of interest can be detected at the level of one part-per-billion or better. We ha…
▽ More
We describe purity measurements of the natural and enriched xenon stockpiles used by the EXO-200 double beta decay experiment based on a mass spectrometry technique. The sensitivity of the spectrometer is enhanced by several orders of magnitude by the presence of a liquid nitrogen cold trap, and many impurity species of interest can be detected at the level of one part-per-billion or better. We have used the technique to screen the EXO-200 xenon before, during, and after its use in our detector, and these measurements have proven useful. This is the first application of the cold trap mass spectrometry technique to an operating physics experiment.
△ Less
Submitted 5 September, 2011;
originally announced September 2011.
-
Observation of Two-Neutrino Double-Beta Decay in Xe-136 with EXO-200
Authors:
N. Ackerman,
B. Aharmim,
M. Auger,
D. J. Auty,
P. S. Barbeau,
K. Barry,
L. Bartoszek,
E. Beauchamp,
V. Belov,
C. Benitez-Medina,
M. Breidenbach,
A. Burenkov,
B. Cleveland,
R. Conley,
E. Conti,
J. Cook,
S. Cook,
A. Coppens,
I. Counts,
W. Craddock,
T. Daniels,
M. V. Danilov,
C. G. Davis,
J. Davis,
R. deVoe
, et al. (78 additional authors not shown)
Abstract:
We report the observation of two-neutrino double-beta decay in Xe-136 with T_1/2 = 2.11 +- 0.04 (stat.) +- 0.21 (sys.) x 10^21 yr. This second order process, predicted by the Standard Model, has been observed for several nuclei but not for Xe-136. The observed decay rate provides new input to matrix element calculations and to the search for the more interesting neutrino-less double-beta decay, th…
▽ More
We report the observation of two-neutrino double-beta decay in Xe-136 with T_1/2 = 2.11 +- 0.04 (stat.) +- 0.21 (sys.) x 10^21 yr. This second order process, predicted by the Standard Model, has been observed for several nuclei but not for Xe-136. The observed decay rate provides new input to matrix element calculations and to the search for the more interesting neutrino-less double-beta decay, the most sensitive probe for the existence of Majorana particles and the measurement of the neutrino mass scale.
△ Less
Submitted 22 November, 2011; v1 submitted 21 August, 2011;
originally announced August 2011.
-
A xenon gas purity monitor for EXO
Authors:
EXO Collaboration,
A. Dobi,
C. Hall,
S. Herrin,
A. Odian,
C. Y. Prescott,
P. C. Rowson,
N. Ackerman,
B. Aharmin,
M. Auger,
P. S. Barbeau,
K. Barry,
C. Benitez-Medina,
M. Breidenbach,
S. Cook,
I. Counts,
T. Daniels,
R. DeVoe,
M. J. Dolinski,
K. Donato,
W. Fairbank Jr.,
J. Farine,
G. Giroux,
R. Gornea,
K. Graham
, et al. (35 additional authors not shown)
Abstract:
We discuss the design, operation, and calibration of two versions of a xenon gas purity monitor (GPM) developed for the EXO double beta decay program. The devices are sensitive to concentrations of oxygen well below 1 ppb at an ambient gas pressure of one atmosphere or more. The theory of operation of the GPM is discussed along with the interactions of oxygen and other impurities with the GPM's tu…
▽ More
We discuss the design, operation, and calibration of two versions of a xenon gas purity monitor (GPM) developed for the EXO double beta decay program. The devices are sensitive to concentrations of oxygen well below 1 ppb at an ambient gas pressure of one atmosphere or more. The theory of operation of the GPM is discussed along with the interactions of oxygen and other impurities with the GPM's tungsten filament. Lab tests and experiences in commissioning the EXO-200 double beta decay experiment are described. These devices can also be used on other noble gases.
△ Less
Submitted 9 June, 2011;
originally announced June 2011.
-
A magnetically-driven piston pump for ultra-clean applications
Authors:
F. LePort,
R. Neilson,
P. S. Barbeau,
K. Barry,
L. Bartoszek,
I. Counts,
J. Davis,
R. deVoe,
M. J. Dolinski,
G. Gratta,
M. Green,
M. Montero Díez,
A. R. Müller,
K. O'Sullivan,
A. Rivas,
K. Twelker,
B. Aharmim,
M. Auger,
V. Belov,
C. Benitez-Medina,
M. Breidenbach,
A. Burenkov,
B. Cleveland,
R. Conley,
J. Cook
, et al. (55 additional authors not shown)
Abstract:
A magnetically driven piston pump for xenon gas recirculation is presented. The pump is designed to satisfy extreme purity and containment requirements, as is appropriate for the recirculation of isotopically enriched xenon through the purification system and large liquid xenon TPC of EXO-200. The pump, using sprung polymer gaskets, is capable of pum** more than 16 standard liters per minute (SL…
▽ More
A magnetically driven piston pump for xenon gas recirculation is presented. The pump is designed to satisfy extreme purity and containment requirements, as is appropriate for the recirculation of isotopically enriched xenon through the purification system and large liquid xenon TPC of EXO-200. The pump, using sprung polymer gaskets, is capable of pum** more than 16 standard liters per minute (SLPM) of xenon gas with 750 torr differential pressure.
△ Less
Submitted 26 April, 2011;
originally announced April 2011.
-
A simple radionuclide-driven single-ion source
Authors:
M. Montero Díez,
K. Twelker,
W. Fairbank Jr.,
G. Gratta,
P. S. Barbeau,
K. Barry,
R. DeVoe,
M. J. Dolinski,
M. Green,
F. LePort,
A. R. Müller,
R. Neilson,
K. O'Sullivan,
N. Ackerman,
B. Aharmin,
M. Auger,
C. Benitez-Medina,
M. Breidenbach,
A. Burenkov,
S. Cook,
T. Daniels,
K. Donato,
J. Farine,
G. Giroux,
R. Gornea
, et al. (32 additional authors not shown)
Abstract:
We describe a source capable of producing single barium ions through nuclear recoils in radioactive decay. The source is fabricated by electroplating 148Gd onto a silicon α-particle detector and vapor depositing a layer of BaF2 over it. 144Sm recoils from the alpha decay of 148Gd are used to dislodge Ba+ ions from the BaF2 layer and emit them in the surrounding environment. The simultaneous detect…
▽ More
We describe a source capable of producing single barium ions through nuclear recoils in radioactive decay. The source is fabricated by electroplating 148Gd onto a silicon α-particle detector and vapor depositing a layer of BaF2 over it. 144Sm recoils from the alpha decay of 148Gd are used to dislodge Ba+ ions from the BaF2 layer and emit them in the surrounding environment. The simultaneous detection of an α particle in the substrate detector allows for tagging of the nuclear decay and of the Ba+ emission. The source is simple, durable, and can be manipulated and used in different environments. We discuss the fabrication process, which can be easily adapted to emit most other chemical species, and the performance of the source.
△ Less
Submitted 19 August, 2010;
originally announced August 2010.
-
Characterization of large area APDs for the EXO-200 detector
Authors:
R. Neilson,
F. LePort,
A. Pocar,
K. Kumar,
A. Odian,
C. Y. Prescott,
V. Tenev,
N. Ackerman,
D. Akimov,
M. Auger,
C. Benitez-Medina,
M. Breidenbach,
A. Burenkov,
R. Conley,
S. Cook,
R. deVoe,
M. J. Dolinski,
W. Fairbank Jr.,
J. Farine,
P. Fierlinger,
B. Flatt,
R. Gornea,
G. Gratta,
M. Green,
C. Hall
, et al. (27 additional authors not shown)
Abstract:
EXO-200 uses 468 large area avalanche photodiodes (LAAPDs) for detection of scintillation light in an ultra-low-background liquid xenon (LXe) detector. We describe initial measurements of dark noise, gain and response to xenon scintillation light of LAAPDs at temperatures from room temperature to 169K - the temperature of liquid xenon. We also describe the individual characterization of more tha…
▽ More
EXO-200 uses 468 large area avalanche photodiodes (LAAPDs) for detection of scintillation light in an ultra-low-background liquid xenon (LXe) detector. We describe initial measurements of dark noise, gain and response to xenon scintillation light of LAAPDs at temperatures from room temperature to 169K - the temperature of liquid xenon. We also describe the individual characterization of more than 800 LAAPDs for selective installation in the EXO-200 detector.
△ Less
Submitted 13 June, 2009;
originally announced June 2009.