Showing 1–2 of 2 results for author: Benhamou, Y
-
Performance of a First Microhexcavity Plasma Panel Detector with Muons
Authors:
Alexis Mulski,
Yan Benhamou,
Erez Etzion,
Claudio Ferretti,
Peter S. Friedman,
Daniel S. Levin,
Meny Raviv Moshe,
David Reikher,
Nicholas Ristow
Abstract:
The microhexcavity plasma panel detector is a type of gaseous particle detector consisting of a close-packed array of millimeter-size hexagonal cells. The cells are biased to operate in Geiger mode where each cell functions as an independent detection unit. The response of the detector to ionizing radiation was investigated using low-energy radioactive $ β$ sources and cosmic ray muons. Efficiency…
▽ More
The microhexcavity plasma panel detector is a type of gaseous particle detector consisting of a close-packed array of millimeter-size hexagonal cells. The cells are biased to operate in Geiger mode where each cell functions as an independent detection unit. The response of the detector to ionizing radiation was investigated using low-energy radioactive $ β$ sources and cosmic ray muons. Efficiency measurements were conducted with cosmic ray muons in conjunction with a scintillator hodoscope. The rate response and signals obtained from the microhexcavity detector filled with Penning gas mixture at atmospheric pressure are herein described. The relative pixel efficiency, after allowing for ion-pair formation in the gas volume, is 96.8 $ \pm $ 4.4$ \% $ for operation of the detector above an applied high voltage of 1000 V.
△ Less
Submitted 16 November, 2017;
originally announced November 2017.
-
Microhexcavity Plasma Panel Detectors
Authors:
Alexis Mulski,
Daniel S. Levin,
Yan Benhamou,
John W. Chapman,
Achintya Das,
Erez Etzion,
Claudio Ferretti,
Peter S. Friedman,
Meny Raviv-Moshe,
David Reikher,
Nicholas Ristow
Abstract:
Plasma panel detectors are a variant of micropattern detectors that are sensitive to ionizing radiation. They are motivated by the design and operation of plasma display panels. The detectors consist of arrays of electrically and optically isolated pixels defined by metallized cavities embedded in a dielectric substrate. These are hermetically sealed gaseous detectors that use exclusively non-hydr…
▽ More
Plasma panel detectors are a variant of micropattern detectors that are sensitive to ionizing radiation. They are motivated by the design and operation of plasma display panels. The detectors consist of arrays of electrically and optically isolated pixels defined by metallized cavities embedded in a dielectric substrate. These are hermetically sealed gaseous detectors that use exclusively non-hydrocarbon gas mixtures. The newest variant of these closed-architecture detectors is known as the Microhexcavity plasma panel detector ($μ$Hex) consisting of 2 mm wide, regular close-packed hexagonal pixels each with a circular thick-film anode. The fabrication, staging, and operation of these detectors is described. Initial tests with the $μ$Hex detectors operated in Geiger mode yield Volt-level signals in the presence of ionizing radiation. The spontaneous discharge rate in the absence of a source is roughly 3-4 orders of magnitude lower compared to the rates measured using low energy betas.
△ Less
Submitted 18 September, 2017; v1 submitted 13 September, 2017;
originally announced September 2017.