Investigating heterogeneous PSMA ligand uptake inside parotid glands
Authors:
Caleb Sample,
Carlos Uribe,
Arman Rahmim,
François Bénard,
Jonn Wu,
Haley Clark
Abstract:
The purpose was to investigate the spatial heterogeneity of prostate-specific membrane antigen (PSMA) positron emission tomography (PET) uptake within parotid glands. We aim to quantify patterns in well-defined regions to facilitate further investigations. Furthermore, we investigate whether uptake is correlated with computed tomography (CT) texture features. Parotid glands from [18F]DCFPyL PSMA P…
▽ More
The purpose was to investigate the spatial heterogeneity of prostate-specific membrane antigen (PSMA) positron emission tomography (PET) uptake within parotid glands. We aim to quantify patterns in well-defined regions to facilitate further investigations. Furthermore, we investigate whether uptake is correlated with computed tomography (CT) texture features. Parotid glands from [18F]DCFPyL PSMA PET/CT images of 30 prostate cancer patients were analyzed. Thresholding was used to define high-uptake regions, and uptake statistics were computed within various divisions. Spearman's rank correlation coefficient was calculated between PSMA PET uptake and the Grey Level Run Length Matrix (GLRLM) using a long and short run length emphasis (GLRLML and GLRLMS) in subregions of parotid glands. PSMA PET uptake was significantly higher (p < 0.001) in lateral/posterior regions of the glands than anterior/medial regions. Maximum uptake was found in the lateral half of parotid glands in 50 out of 60 glands. The difference in SUV between parotid halves is greatest when parotids are divided by a plane separating the anterior/medial and posterior/lateral halves symmetrically. PSMA PET uptake was significantly correlated with CT GLRLML (p < 0.001), and anti-correlated with CT GLRLMS (p < 0.001). Uptake of PSMA PET is heterogeneous within parotid glands, with uptake biased towards lateral and posterior regions. Uptake patterns within parotid glands were found to be strongly correlated with CT texture features, suggesting the possible future use of CT texture features as a proxy for inferring PSMA PET uptake in salivary glands.
△ Less
Submitted 4 January, 2024;
originally announced January 2024.
-
Comprehensive Evaluation and Insights into the Use of Deep Neural Networks to Detect and Quantify Lymphoma Lesions in PET/CT Images
Authors:
Shadab Ahamed,
Yixi Xu,
Claire Gowdy,
Joo H. O,
Ingrid Bloise,
Don Wilson,
Patrick Martineau,
François Bénard,
Fereshteh Yousefirizi,
Rahul Dodhia,
Juan M. Lavista,
William B. Weeks,
Carlos F. Uribe,
Arman Rahmim
Abstract:
This study performs comprehensive evaluation of four neural network architectures (UNet, SegResNet, DynUNet, and SwinUNETR) for lymphoma lesion segmentation from PET/CT images. These networks were trained, validated, and tested on a diverse, multi-institutional dataset of 611 cases. Internal testing (88 cases; total metabolic tumor volume (TMTV) range [0.52, 2300] ml) showed SegResNet as the top p…
▽ More
This study performs comprehensive evaluation of four neural network architectures (UNet, SegResNet, DynUNet, and SwinUNETR) for lymphoma lesion segmentation from PET/CT images. These networks were trained, validated, and tested on a diverse, multi-institutional dataset of 611 cases. Internal testing (88 cases; total metabolic tumor volume (TMTV) range [0.52, 2300] ml) showed SegResNet as the top performer with a median Dice similarity coefficient (DSC) of 0.76 and median false positive volume (FPV) of 4.55 ml; all networks had a median false negative volume (FNV) of 0 ml. On the unseen external test set (145 cases with TMTV range: [0.10, 2480] ml), SegResNet achieved the best median DSC of 0.68 and FPV of 21.46 ml, while UNet had the best FNV of 0.41 ml. We assessed reproducibility of six lesion measures, calculated their prediction errors, and examined DSC performance in relation to these lesion measures, offering insights into segmentation accuracy and clinical relevance. Additionally, we introduced three lesion detection criteria, addressing the clinical need for identifying lesions, counting them, and segmenting based on metabolic characteristics. We also performed expert intra-observer variability analysis revealing the challenges in segmenting ``easy'' vs. ``hard'' cases, to assist in the development of more resilient segmentation algorithms. Finally, we performed inter-observer agreement assessment underscoring the importance of a standardized ground truth segmentation protocol involving multiple expert annotators. Code is available at: https://github.com/microsoft/lymphoma-segmentation-dnn
△ Less
Submitted 16 November, 2023;
originally announced November 2023.
-
PSMA PET/CT as a predictive tool for sub-regional importance estimates in the parotid gland
Authors:
Caleb Sample,
Arman Rahmim,
François Bénard,
Jonn Wu,
Haley Clark
Abstract:
Xerostomia and radiation-induced salivary gland dysfunction remain a common side effect for head-and-neck radiotherapy patients, and attempts have been made to quantify the heterogeneous dose response within parotid glands. Here several models of parotid gland subregional importance are compared with prostate specific membrane antigen (PSMA) positron emission tomography (PET) uptake. PSMA ligands…
▽ More
Xerostomia and radiation-induced salivary gland dysfunction remain a common side effect for head-and-neck radiotherapy patients, and attempts have been made to quantify the heterogeneous dose response within parotid glands. Here several models of parotid gland subregional importance are compared with prostate specific membrane antigen (PSMA) positron emission tomography (PET) uptake. PSMA ligands show high concentrations in salivary glands, whose uptake has been previously found to relate to gland functionality. We develop a predictive model for relative importance estimates using PSMA PET and CT radiomic features, and demonstrate a methodology for predicting patient-specific importance deviations from the population. Intra-parotid gland uptake was compared with four regional importance models using 30 [18F]DCFPyL PSMA PET images. A radiomics-based predictive model of population importance was developed using a double cross-validation methodology. Population importance estimates were supplemented using patient-specific radiomic features. Anticorrelative relationships were found to exist between PSMA PET uptake and four independent models of subregional parotid gland importance from the literature. Kernel Ridge Regression with principal component analysis feature selection performed best over test sets (MAE = 0.08), with GLCM features being particularly important. Deblurring PSMA PET images strengthened correlations and improved model performance. This study suggests that regions of relatively low PSMA PET concentration in parotid glands may exhibit relatively high dose-sensitivity. We've demonstrated the utility of PSMA PET radiomic features for predicting relative importance within the parotid glands. PSMA PET appears promising for analyzing salivary gland functionality.
△ Less
Submitted 4 January, 2024; v1 submitted 17 September, 2023;
originally announced September 2023.
-
Neural blind deconvolution for deblurring and supersampling PSMA PET
Authors:
Caleb Sample,
Arman Rahmim,
Carlos Uribe,
François Bénard,
Jonn Wu,
Roberto Fedrigo,
Haley Clark
Abstract:
Objective: To simultaneously deblur and supersample prostate specific membrane antigen (PSMA) positron emission tomography (PET) images using neural blind deconvolution. Approach: Blind deconvolution is a method of estimating the hypothetical "deblurred" image along with the blur kernel (related to the point spread function) simultaneously. Traditional \textit{maximum a posteriori} blind deconvolu…
▽ More
Objective: To simultaneously deblur and supersample prostate specific membrane antigen (PSMA) positron emission tomography (PET) images using neural blind deconvolution. Approach: Blind deconvolution is a method of estimating the hypothetical "deblurred" image along with the blur kernel (related to the point spread function) simultaneously. Traditional \textit{maximum a posteriori} blind deconvolution methods require stringent assumptions and suffer from convergence to a trivial solution. A method of modelling the deblurred image and kernel with independent neural networks, called "neural blind deconvolution" had demonstrated success for deblurring 2D natural images in 2020. In this work, we adapt neural blind deconvolution for PVE correction of PSMA PET images with simultaneous supersampling. We compare this methodology with several interpolation methods, using blind image quality metrics, and test the model's ability to predict kernels by re-running the model after applying artificial "pseudokernels" to deblurred images. The methodology was tested on a retrospective set of 30 prostate patients as well as phantom images containing spherical lesions of various volumes. Results: Neural blind deconvolution led to improvements in image quality over other interpolation methods in terms of blind image quality metrics, recovery coefficients, and visual assessment. Predicted kernels were similar between patients, and the model accurately predicted several artificially-applied pseudokernels. Localization of activity in phantom spheres was improved after deblurring, allowing small lesions to be more accurately defined. Significance: The intrinsically low spatial resolution of PSMA PET leads to PVEs which negatively impact uptake quantification in small regions. The proposed method can be used to mitigate this issue, and can be straightforwardly adapted for other imaging modalities.
△ Less
Submitted 2 March, 2024; v1 submitted 1 September, 2023;
originally announced September 2023.
-
Semi-supervised learning towards automated segmentation of PET images with limited annotations: Application to lymphoma patients
Authors:
Fereshteh Yousefirizi,
Isaac Shiri,
Joo Hyun O,
Ingrid Bloise,
Patrick Martineau,
Don Wilson,
François Bénard,
Laurie H. Sehn,
Kerry J. Savage,
Habib Zaidi,
Carlos F. Uribe,
Arman Rahmim
Abstract:
The time-consuming task of manual segmentation challenges routine systematic quantification of disease burden. Convolutional neural networks (CNNs) hold significant promise to reliably identify locations and boundaries of tumors from PET scans. We aimed to leverage the need for annotated data via semi-supervised approaches, with application to PET images of diffuse large B-cell lymphoma (DLBCL) an…
▽ More
The time-consuming task of manual segmentation challenges routine systematic quantification of disease burden. Convolutional neural networks (CNNs) hold significant promise to reliably identify locations and boundaries of tumors from PET scans. We aimed to leverage the need for annotated data via semi-supervised approaches, with application to PET images of diffuse large B-cell lymphoma (DLBCL) and primary mediastinal large B-cell lymphoma (PMBCL). We analyzed 18F-FDG PET images of 292 patients with PMBCL (n=104) and DLBCL (n=188) (n=232 for training and validation, and n=60 for external testing). We employed FCM and MS losses for training a 3D U-Net with different levels of supervision: i) fully supervised methods with labeled FCM (LFCM) as well as Unified focal and Dice loss functions, ii) unsupervised methods with Robust FCM (RFCM) and Mumford-Shah (MS) loss functions, and iii) Semi-supervised methods based on FCM (RFCM+LFCM), as well as MS loss in combination with supervised Dice loss (MS+Dice). Unified loss function yielded higher Dice score (mean +/- standard deviation (SD)) (0.73 +/- 0.03; 95% CI, 0.67-0.8) compared to Dice loss (p-value<0.01). Semi-supervised (RFCM+alpha*LFCM) with alpha=0.3 showed the best performance, with a Dice score of 0.69 +/- 0.03 (95% CI, 0.45-0.77) outperforming (MS+alpha*Dice) for any supervision level (any alpha) (p<0.01). The best performer among (MS+alpha*Dice) semi-supervised approaches with alpha=0.2 showed a Dice score of 0.60 +/- 0.08 (95% CI, 0.44-0.76) compared to another supervision level in this semi-supervised approach (p<0.01). Semi-supervised learning via FCM loss (RFCM+alpha*LFCM) showed improved performance compared to supervised approaches. Considering the time-consuming nature of expert manual delineations and intra-observer variabilities, semi-supervised approaches have significant potential for automated segmentation workflows.
△ Less
Submitted 25 March, 2024; v1 submitted 19 December, 2022;
originally announced December 2022.
-
SleepNet: Automated Sleep Analysis via Dense Convolutional Neural Network Using Physiological Time Series
Authors:
Bahareh Pourbabaee,
Matthew Howe-Patterson,
Matthew Patterson,
Frederic Benard
Abstract:
In this work, a dense recurrent convolutional neural network (DRCNN) was constructed to detect sleep disorders including arousal, apnea and hypopnea using Polysomnography (PSG) measurement channels provided in the 2018 Physionet challenge database. Our model structure is composed of multiple dense convolutional units (DCU) followed by a bidirectional long-short term memory (LSTM) layer followed by…
▽ More
In this work, a dense recurrent convolutional neural network (DRCNN) was constructed to detect sleep disorders including arousal, apnea and hypopnea using Polysomnography (PSG) measurement channels provided in the 2018 Physionet challenge database. Our model structure is composed of multiple dense convolutional units (DCU) followed by a bidirectional long-short term memory (LSTM) layer followed by a softmax output layer. The sleep events including sleep stages, arousal regions and multiple types of apnea and hypopnea are manually annotated by experts which enables us to train our proposed network using a multi-task learning mechanism. Three binary cross-entropy loss functions corresponding to sleep/wake, target arousal and apnea-hypopnea/normal detection tasks are summed up to generate our overall network loss function that is optimized using the Adam method. Our model performance was evaluated using two metrics: the area under the precision-recall curve (AUPRC) and the area under the receiver operating characteristic curve (AUROC). To measure our model generalization, 4-fold cross-validation was also performed. For training, our model was applied to full night recording data. Finally, the average AUPRC and AUROC values associated with the arousal detection task were 0.505 and 0.922, respectively on our testing dataset. An ensemble of four models trained on different data folds improved the AUPRC and AUROC to 0.543 and 0.931, respectively. Our proposed algorithm achieved the first place in the official stage of the 2018 Physionet challenge for detecting sleep arousals with AUPRC of 0.54 on the blind testing dataset.
△ Less
Submitted 24 July, 2019; v1 submitted 11 March, 2019;
originally announced March 2019.
-
Liquid Xenon Detectors for Positron Emission Tomography
Authors:
A. Miceli,
P. Amaudruz,
F. Benard,
D. A. Bryman,
L. Kurchaninov,
J. P. Martin,
A. Muennich,
F. Retiere,
T. J. Ruth,
V. Sossi,
A. J. Stoessl
Abstract:
PET is a functional imaging technique based on detection of annihilation photons following beta decay producing positrons. In this paper, we present the concept of a new PET system for preclinical applications consisting of a ring of twelve time projection chambers filled with liquid xenon viewed by avalanche photodiodes. Simultaneous measurement of ionization charge and scintillation light leads…
▽ More
PET is a functional imaging technique based on detection of annihilation photons following beta decay producing positrons. In this paper, we present the concept of a new PET system for preclinical applications consisting of a ring of twelve time projection chambers filled with liquid xenon viewed by avalanche photodiodes. Simultaneous measurement of ionization charge and scintillation light leads to a significant improvement to spatial resolution, image quality, and sensitivity. Simulated performance shows that an energy resolution of <10% (FWHM) and a sensitivity of 15% are achievable. First tests with a prototype TPC indicate position resolution <1 mm (FWHM).
△ Less
Submitted 7 April, 2011;
originally announced April 2011.