-
WIN-PDQ: A Wiener-estimator-based projection-domain quantitative SPECT method that accounts for intra-regional uptake heterogeneity
Authors:
Zekun Li,
Nadia Benabdallah,
Daniel L. J. Thorek,
Abhinav K. Jha
Abstract:
SPECT can enable the quantification of activity uptake in lesions and at-risk organs in α-particle-emitting radiopharmaceutical therapies (α-RPTs). But this quantification is challenged by the low photon counts, complicated isotope physics, and the image-degrading effects in α-RPT SPECT. Thus, strategies to optimize the SPECT system and protocol designs for the task of regional uptake quantificati…
▽ More
SPECT can enable the quantification of activity uptake in lesions and at-risk organs in α-particle-emitting radiopharmaceutical therapies (α-RPTs). But this quantification is challenged by the low photon counts, complicated isotope physics, and the image-degrading effects in α-RPT SPECT. Thus, strategies to optimize the SPECT system and protocol designs for the task of regional uptake quantification are needed. Objectively performing this task-based optimization requires a reliable (accurate and precise) regional uptake quantification method. Conventional reconstruction-based quantification (RBQ) methods have been observed to be erroneous for α-RPT SPECT. Projection-domain quantification methods, which estimate regional uptake directly from SPECT projections, have demonstrated potential in providing reliable regional uptake estimates, but these methods assume constant uptake within the regions, an assumption that may not hold. To address these challenges, we propose WIN-PDQ, a Wiener-estimator-based projection-domain quantitative SPECT method. The method accounts for the heterogeneity within the regions of interest while estimating mean uptake. An early-stage evaluation of the method was conducted using 3D Monte Carlo-simulated SPECT of anthropomorphic phantoms with radium-223 uptake and lumpy-model-based intra-regional uptake heterogeneity. In this evaluation with phantoms of varying mean regional uptake and intra-regional uptake heterogeneity, the WIN-PDQ method yielded ensemble unbiased estimates and significantly outperformed both reconstruction-based and previously proposed projection-domain quantification methods. In conclusion, based on these preliminary findings, the proposed method is showing potential for estimating mean regional uptake in α-RPTs and towards enabling the objective task-based optimization of SPECT system and protocol designs.
△ Less
Submitted 25 March, 2024;
originally announced March 2024.
-
Joint regional uptake quantification of Thorium-227 and Radium-223 using a multiple-energy-window projection-domain quantitative SPECT method
Authors:
Zekun Li,
Nadia Benabdallah,
Richard Laforest,
Richard L. Wahl,
Daniel L. J. Thorek,
Abhinav K. Jha
Abstract:
Thorium-227-based alpha-particle radiopharmaceutical therapies (α-RPTs) are being investigated in several clinical and pre-clinical studies. After administration, Thorium-227 decays to Radium-223, another alpha-particle-emitting isotope, which redistributes within the patient. Reliable dose quantification of both Thorium-227 and Radium-223 is clinically important, and SPECT may perform this quanti…
▽ More
Thorium-227-based alpha-particle radiopharmaceutical therapies (α-RPTs) are being investigated in several clinical and pre-clinical studies. After administration, Thorium-227 decays to Radium-223, another alpha-particle-emitting isotope, which redistributes within the patient. Reliable dose quantification of both Thorium-227 and Radium-223 is clinically important, and SPECT may perform this quantification as these isotopes also emit X- and gamma-ray photons. However, reliable quantification is challenged by the orders-of-magnitude lower activity compared to conventional SPECT, resulting in a very low number of detected counts, the presence of multiple photopeaks, substantial overlap in the emission spectra of these isotopes, and the image-degrading effects in SPECT. To address these issues, we propose a multiple-energy-window projection-domain quantification (MEW-PDQ) method that jointly estimates the regional activity uptake of both Thorium-227 and Radium-223 directly using the SPECT projection from multiple energy windows. We evaluated the method with realistic simulation studies using anthropomorphic digital phantoms, in the context of imaging patients with bone metastases of prostate cancer and treated with Thorium-227-based α-RPTs. The proposed method yielded reliable (accurate and precise) regional uptake estimates of both isotopes and outperformed state-of-the-art methods across different lesion sizes and contrasts, in a virtual imaging trial, as well as with moderate levels of intra-regional heterogeneous uptake and with moderate inaccuracies in the definitions of the support of various regions. Additionally, we demonstrated the effectiveness of using multiple energy windows and the variance of the estimated uptake using the proposed method approached the Cramér-Rao-lower-bound-defined theoretical limit.
△ Less
Submitted 1 July, 2024; v1 submitted 26 May, 2023;
originally announced May 2023.
-
A projection-domain low-count quantitative SPECT method for alpha-particle emitting radiopharmaceutical therapy
Authors:
Zekun Li,
Nadia Benabdallah,
Diane S. Abou,
Brian C. Baumann,
Farrokh Dehdashti,
David H. Ballard,
Jonathan Liu,
Uday Jammalamadaka,
Richard Laforest,
Richard L. Wahl,
Daniel L. J. Thorek,
Abhinav K. Jha
Abstract:
Single-photon emission computed tomography (SPECT) provides a mechanism to estimate regional isotope uptake in lesions and at-risk organs after administration of α-particle-emitting radiopharmaceutical therapies (α-RPTs). However, this estimation task is challenging due to the complex emission spectra, the very low number of detected counts, the impact of stray-radiation-related noise at these low…
▽ More
Single-photon emission computed tomography (SPECT) provides a mechanism to estimate regional isotope uptake in lesions and at-risk organs after administration of α-particle-emitting radiopharmaceutical therapies (α-RPTs). However, this estimation task is challenging due to the complex emission spectra, the very low number of detected counts, the impact of stray-radiation-related noise at these low counts, and the multiple image-degrading processes in SPECT. The conventional reconstruction-based quantification methods are observed to be erroneous for α-RPT SPECT. To address these challenges, we developed a low-count quantitative SPECT (LC-QSPECT) method that directly estimates the regional activity uptake from the projection data, compensates for stray-radiation-related noise, and for the radioisotope and SPECT physics. The method was validated in the context of three-dimensional SPECT with 223 Ra. Validation was performed using both realistic simulation studies, including a virtual clinical trial, and synthetic and anthropomorphic physical-phantom studies. Across all studies, the LC-QSPECT method yielded reliable regional-uptake estimates and outperformed the conventional ordered subset expectation maximization (OSEM)-based reconstruction and geometric transfer matrix (GTM)-based post-reconstruction partial-volume compensation methods. Further, the method yielded reliable uptake across different lesion sizes, contrasts, and different levels of intra-lesion heterogeneity. Additionally, the variance of the estimated uptake approached the Cramé-Rao bound-defined theoretical limit.
△ Less
Submitted 11 May, 2022; v1 submitted 1 July, 2021;
originally announced July 2021.