Skip to main content

Showing 1–4 of 4 results for author: Belli, G

.
  1. arXiv:1406.2119  [pdf, other

    physics.ins-det physics.med-ph

    Multigap RPC time resolution to 511 keV annihilation photons

    Authors: G. Belli, M. Gabusi, G. Musitelli, R. Nardò, S. P. Ratti, A. Tamborini, P. Vitulo

    Abstract: The time resolution of Multigap Resistive Plate Counters (MRPCs) to $511$ keV gamma rays has been investigated using a $^{22}$Na source and four detectors. The MRPCs time resolution has been derived from the Time-of-Flight information, measured from pairs of space correlated triggered events. A GEANT4 simulation has been performed to analyze possible setup contributions and to support experimental… ▽ More

    Submitted 9 June, 2014; originally announced June 2014.

    Comments: 25 pages, 14 figures

  2. arXiv:1012.5511  [pdf, ps, other

    physics.ins-det hep-ex

    Study of gas purifiers for the CMS RPC detector

    Authors: L. Benussi, S. Bianco, S. Colafranceschi, F. L. Fabbri, F. Felli, M. Ferrini, M. Giardoni, T. Greci, A. Paolozzi, L. Passamonti, D. Piccolo, D. Pierluigi, A. Russo, G. Saviano, S. Buontempo, A. Cimmino, M. de Gruttola, F Fabozzi d A. O. M. Iorio, L. Lista, P. Paolucci, P. Baesso, G. Belli, D. Pagano, S. P. Ratti, A. Vicini , et al. (4 additional authors not shown)

    Abstract: The CMS RPC muon detector utilizes a gas recirculation system called closed loop (CL) to cope with large gas mixture volumes and costs. A systematic study of CL gas purifiers has been carried out over 400 days between July 2008 and August 2009 at CERN in a low-radiation test area, with the use of RPC chambers with currents monitoring, and gas analysis sampling points. The study aimed to fully clar… ▽ More

    Submitted 26 December, 2010; originally announced December 2010.

  3. arXiv:1012.5508  [pdf, ps, other

    physics.ins-det hep-ex

    A new approach in modeling the response of RPC detectors

    Authors: L. Benussi, S. Bianco, S. Colafranceschi, F. L. Fabbri, M. Giardoni, L. Passamonti, D. Piccolo, D. Pierluigi, A. Russo, G. Saviano, S. Buontempo, A. Cimmino, M. de Gruttola, F Fabozzi, A. O. M. Iorio, L. Lista, P. Paolucci, P. Baesso, G. Belli, D. Pagano, S. P. Ratti, A. Vicini, P. Vitulo, C. Viviani, A. Sharma , et al. (1 additional authors not shown)

    Abstract: The response of RPC detectors is highly sensitive to environmental variables. A novel approach is presented to model the response of RPC detectors in a variety of experimental conditions. The algorithm, based on Artificial Neural Networks, has been developed and tested on the CMS RPC gas gain monitoring system during commissioning.

    Submitted 26 December, 2010; originally announced December 2010.

  4. arXiv:physics/0701014  [pdf, ps, other

    physics.ins-det

    Gas Analysis and Monitoring Systems for the RPC Detector of CMS at LHC

    Authors: M. Abbrescia, A. Colaleo, R. Guida, G. Iaselli, R. Liuzzi, F. Loddo, M. Maggi, B. Marangelli, S. Natali, S. Nuzzo, G. Pugliese, A. Ranieri, F. Romano, R. Trentadue, L. Benussi, M. Bertani, S. Bianco, M. A. Caponero, D. Colonna, D. Donisi, F. L. Fabbri, F. Felli, M. Giardoni B. Ortenzi, M. Pallotta, A. Paolozzi , et al. (16 additional authors not shown)

    Abstract: The Resistive Plate Chambers (RPC) detector of the CMS experiment at the LHC proton collider (CERN, Switzerland) will employ an online gas analysis and monitoring system of the freon-based gas mixture used. We give an overview of the CMS RPC gas system, describe the project parameters and first results on gas-chromatograph analysis. Finally, we report on preliminary results for a set of monitor… ▽ More

    Submitted 30 December, 2006; originally announced January 2007.

    Comments: 9 pages, 8 figures. Presented by Stefano Bianco (Laboratori Nazionali di Frascati dell'INFN) at the IEEE NSS, San Diego (USA), October 2006

    Report number: Frascati preprint LNF-06/34 (P)