-
Accurate Determination of an alkali-inert gas diffusion coefficient using coherent transient emission from a density grating
Authors:
A. Pouliot,
G. Carlse,
T. Vacheresse,
H. C. Beica,
U. Shim,
S. B. Cahn,
A. Turlapov,
T. Sleator,
A. Kumarakrishnan
Abstract:
We demonstrate a new technique for the accurate measurement of diffusion coefficients for alkali vapor in an inert buffer gas. The measurement was performed by establishing a spatially periodic density grating in isotopically pure $^{87}$Rb vapor and observing the decaying coherent emission from the grating due to the diffusive motion of the vapor through N$_2$ buffer gas. We obtain a diffusion co…
▽ More
We demonstrate a new technique for the accurate measurement of diffusion coefficients for alkali vapor in an inert buffer gas. The measurement was performed by establishing a spatially periodic density grating in isotopically pure $^{87}$Rb vapor and observing the decaying coherent emission from the grating due to the diffusive motion of the vapor through N$_2$ buffer gas. We obtain a diffusion coefficient of $0.245 \pm0.002 ~\textrm{cm}^{2}/\textrm{s}$ at 50$\degree$C and 564~Torr. Scaling to atmospheric pressure, we obtain $D_0 = 0.1819 \pm 0.0024~\textrm{cm}^2/\textrm{s}$. To the best of our knowledge, this represents the most accurate determination of the Rb--N$_2$ diffusion coefficient to date. Our measurements can be extended to different buffer gases and alkali vapors used for magnetometry and can be used to constrain theoretical diffusion models for these systems.
△ Less
Submitted 16 February, 2021; v1 submitted 12 February, 2021;
originally announced February 2021.
-
Technique for rapid mass determination of airborne micro-particles based on release and recapture from an optical dipole force trap
Authors:
Gehrig Carlse,
Kevin B. Borsos,
Hermina C. Beica,
Thomas Vacheresse,
Alex Pouliot,
Jorge Perez-Garcia,
Andrejs Vorozcovs,
Boris Barron,
Shira Jackson,
Louis Marmet,
A. Kumarakrishnan
Abstract:
We describe a new method for the rapid determination of the mass of particles confined in a free-space optical dipole-force trap. The technique relies on direct imaging of drop-and-restore experiments without the need for a vacuum environment. In these experiments, the trap** light is rapidly shuttered with an acousto-optic modulator causing the particle to be released from and subsequently reca…
▽ More
We describe a new method for the rapid determination of the mass of particles confined in a free-space optical dipole-force trap. The technique relies on direct imaging of drop-and-restore experiments without the need for a vacuum environment. In these experiments, the trap** light is rapidly shuttered with an acousto-optic modulator causing the particle to be released from and subsequently recaptured by the trap** force. The trajectories of both the falls and restorations, imaged using a high-speed CMOS sensor, are combined to determine the particle mass. We corroborate these measurements using an analysis of position autocorrelation functions of the trapped particles. We report a statistical uncertainty of less than 2% for masses on the order of $5\times10^{-14}$ kg using a data acquisition time of approximately 90 seconds.
△ Less
Submitted 1 June, 2020;
originally announced June 2020.
-
Investigations of optical pum** for magnetometry using an auto-locking laser system
Authors:
Alexander Pouliot,
Hermina C. Beica,
Adam Carew,
Andrejs Vorozcovs,
Gehrig Carlse,
Brynle Barrett,
Anantharaman Kumarakrishnan
Abstract:
We have developed a versatile pulsed laser system for high precision magnetometry. The operating wavelength of the system can be configured to optically pump alkali vapors such as rubidium and cesium. The laser system consists of an auto-locked, interference filter stabilized, external cavity diode laser (ECDL), a tapered waveguide amplifier, and a pulsing module. The auto-locking controller can b…
▽ More
We have developed a versatile pulsed laser system for high precision magnetometry. The operating wavelength of the system can be configured to optically pump alkali vapors such as rubidium and cesium. The laser system consists of an auto-locked, interference filter stabilized, external cavity diode laser (ECDL), a tapered waveguide amplifier, and a pulsing module. The auto-locking controller can be used by an untrained operator to stabilize the laser frequency with respect to a library of atomic, molecular, and solid-state spectral markers. The ECDL output can be amplified from 20 mW to 2 W in continuous wave (CW) mode. The pulsing module, which includes an acousto-optic modulator (AOM), can generate pulses with durations of 20 ns and repetition rates of several MHz. Accordingly, the laser system is well suited for applications such as gravimetry, magnetometry, and differential-absorption lidar. In this work, we focus on magnetometric applications and demonstrate that the laser source is suitable for optically pum** rubidium vapor. We also describe numerical simulations of optical pum** relevant to the rubidium D1 and D2 transitions at 795 nm and 780 nm respectively. These studies are relevant to the design and construction of a new generation of portable, rubidium, spin-exchange relaxation-free (SERF) magnetometers, capable of sensitivities of 1 fT Hz-1/2 1.
△ Less
Submitted 18 May, 2018;
originally announced May 2018.
-
Auto-locking Waveguide Amplifier System for Lidar and Magnetometric Applications
Authors:
Alexander Pouliot,
Hermina C. Beica,
Adam Carew,
Andrejs Vorozcovs,
Gehrig Carlse,
Anantharaman Kumarakrishnan
Abstract:
We describe a compact waveguide amplifier system that is suitable for optically pum** rubidium magnetometers. The system consists of an auto-locking vacuum-sealed external cavity diode laser, a semiconductor tapered amplifier and a pulsing unit based on an acousto-optic modulator. The diode laser utilises optical feedback from an interference filter to narrow the linewidth of an inexpensive lase…
▽ More
We describe a compact waveguide amplifier system that is suitable for optically pum** rubidium magnetometers. The system consists of an auto-locking vacuum-sealed external cavity diode laser, a semiconductor tapered amplifier and a pulsing unit based on an acousto-optic modulator. The diode laser utilises optical feedback from an interference filter to narrow the linewidth of an inexpensive laser diode to ~500 kHz. This output is scannable over an 8 GHz range (at 780 nm) and can be locked without human intervention to any spectral marker in an expandable library of reference spectra, using the autolocking controller. The tapered amplifier amplifies the output from 50 mW up to 2 W with negligible distortions in the spectral quality. The system can operate at visible and near infrared wavelengths with MHz repetition rates. We demonstrate optical pum** of rubidium vapour with this system for magnetometric applications. The magnetometer detects the differential absorption of two orthogonally polarized components of a linearly polarized probe laser following optical pum** by a circularly polarized pump laser. The differential absorption signal is studied for a range of pulse lengths, pulse amplitudes and DC magnetic fields. Our results suggest that this laser system is suitable for optically pum** spin-exchange free magnetometers.
△ Less
Submitted 18 May, 2018;
originally announced May 2018.
-
Prospects for Precise Measurements with Echo Atom Interferometry
Authors:
Brynle Barrett,
Adam Carew,
Hermina C. Beica,
Andrejs Vorozcovs,
Alexander Pouliot,
A. Kumarakrishnan
Abstract:
Echo atom interferometers have emerged as interesting alternatives to Raman interferometers for the realization of precise measurements of the gravitational acceleration $g$ and the determination of the atomic fine structure through measurements of the atomic recoil frequency $ω_q$. Here we review the development of different configurations of echo interferometers that are best suited to achieve t…
▽ More
Echo atom interferometers have emerged as interesting alternatives to Raman interferometers for the realization of precise measurements of the gravitational acceleration $g$ and the determination of the atomic fine structure through measurements of the atomic recoil frequency $ω_q$. Here we review the development of different configurations of echo interferometers that are best suited to achieve these goals. We describe experiments that utilize near-resonant excitation of laser-cooled rubidium atoms by a sequence of standing wave pulses to measure $ω_q$ with a statistical uncertainty of 37 parts per billion (ppb) on a time scale of $\sim 50$ ms and $g$ with a statistical precision of 75 ppb. Related coherent transient techniques that have achieved the most statistically precise measurements of atomic g-factor ratios are also outlined. We discuss the reduction of prominent systematic effects in these experiments using off-resonant excitation by low-cost, high-power lasers.
△ Less
Submitted 22 June, 2016;
originally announced June 2016.