Skip to main content

Showing 1–9 of 9 results for author: Bedikian, S

.
  1. arXiv:1310.8214  [pdf, other

    astro-ph.CO astro-ph.IM hep-ex physics.ins-det

    First results from the LUX dark matter experiment at the Sanford Underground Research Facility

    Authors: LUX Collaboration, D. S. Akerib, H. M. Araujo, X. Bai, A. J. Bailey, J. Balajthy, S. Bedikian, E. Bernard, A. Bernstein, A. Bolozdynya, A. Bradley, D. Byram, S. B. Cahn, M. C. Carmona-Benitez, C. Chan, J. J. Chapman, A. A. Chiller, C. Chiller, K. Clark, T. Coffey, A. Currie, A. Curioni, S. Dazeley, L. de Viveiros, A. Dobi , et al. (78 additional authors not shown)

    Abstract: The Large Underground Xenon (LUX) experiment, a dual-phase xenon time-projection chamber operating at the Sanford Underground Research Facility (Lead, South Dakota), was cooled and filled in February 2013. We report results of the first WIMP search dataset, taken during the period April to August 2013, presenting the analysis of 85.3 live-days of data with a fiducial volume of 118 kg. A profile-li… ▽ More

    Submitted 5 February, 2014; v1 submitted 30 October, 2013; originally announced October 2013.

    Comments: Accepted by Phys. Rev. Lett. Appendix A included as supplementary material with PRL article

    Journal ref: Phys. Rev. Lett. 112, 091303 (2014)

  2. arXiv:1211.3788  [pdf, other

    physics.ins-det hep-ex

    The Large Underground Xenon (LUX) Experiment

    Authors: D. S. Akerib, X. Bai, S. Bedikian, E. Bernard, A. Bernstein, A. Bolozdynya, A. Bradley, D. Byram, S. B. Cahn, C. Camp, M. C. Carmona-Benitez, D. Carr, J. J. Chapman, A. Chiller, C. Chiller, K. Clark, T. Classen, T. Coffey, A. Curioni, E. Dahl, S. Dazeley, L. de Viveiros, A. Dobi, E. Dragowsky, E. Druszkiewicz , et al. (69 additional authors not shown)

    Abstract: The Large Underground Xenon (LUX) collaboration has designed and constructed a dual-phase xenon detector, in order to conduct a search for Weakly Interacting Massive Particles(WIMPs), a leading dark matter candidate. The goal of the LUX detector is to clearly detect (or exclude) WIMPS with a spin independent cross section per nucleon of $2\times 10^{-46}$ cm$^{2}$, equivalent to $\sim$1 event/100… ▽ More

    Submitted 21 November, 2012; v1 submitted 15 November, 2012; originally announced November 2012.

    Comments: 50 pages, 16 figures

    Journal ref: Nuclear Inst. and Methods in Physics Research A704 (2013) 111 - 126

  3. arXiv:1207.3665  [pdf, other

    physics.ins-det astro-ph.IM

    The LUX Prototype Detector: Heat Exchanger Development

    Authors: D. S. Akerib, X. Bai, S. Bedikian, A. Bernstein, A. Bolozdynya, A. Bradley, S. Cahn, D. Carr, J. J. Chapman, K. Clark, T. Classen, A. Curioni, C. E. Dahl, S. Dazeley, L. deViveiros, M. Dragowsky, E. Druszkiewicz, S. Fiorucci, R. J. Gaitskell, C. Hall, C. Faham, B. Holbrook, L. Kastens, K. Kazkaz, J. Kwong , et al. (25 additional authors not shown)

    Abstract: The LUX (Large Underground Xenon) detector is a two-phase xenon Time Projection Chamber (TPC) designed to search for WIMP-nucleon dark matter interactions. As with all noble element detectors, continuous purification of the detector medium is essential to produce a large ($>$1ms) electron lifetime; this is necessary for efficient measurement of the electron signal which in turn is essential for ac… ▽ More

    Submitted 20 January, 2013; v1 submitted 16 July, 2012; originally announced July 2012.

    Comments: 12 pages, 9 figures

  4. arXiv:1112.1376  [pdf, ps, other

    physics.ins-det hep-ex

    Radio-assay of Titanium samples for the LUX Experiment

    Authors: D. S. Akerib, X. Bai, S. Bedikian, E. Bernard, A. Bernstein, A. Bradley, S. B. Cahn, M. C. Carmona-Benitez, D. Carr, J. J. Chapman, Y-D. Chan, K. Clark, T. Classen, T. Coffey, S. Dazeley, L. deViveiros, M. Dragowsky, E. Druszkiewicz, C. H. Faham, S. Fiorucci, R. J. Gaitskell, K. R. Gibson, C. Hall, M. Hanhardt, B. Holbrook , et al. (41 additional authors not shown)

    Abstract: We report on the screening of samples of titanium metal for their radio-purity. The screening process described in this work led to the selection of materials used in the construction of the cryostats for the Large Underground Xenon (LUX) dark matter experiment. Our measurements establish titanium as a highly desirable material for low background experiments searching for rare events. The sample w… ▽ More

    Submitted 12 February, 2012; v1 submitted 6 December, 2011; originally announced December 2011.

    Comments: The LUX Collaboration

  5. arXiv:1111.2074  [pdf, other

    physics.data-an hep-ex nucl-ex

    LUXSim: A Component-Centric Approach to Low-Background Simulations

    Authors: D. S. Akerib, X. Bai, S. Bedikian, E. Bernard, A. Bernstein, A. Bradley, S. B. Cahn, M. C. Carmona-Benitez, D. Carr, J. J. Chapman, K. Clark, T. Classen, T. Coffey, S. Dazeley, L. de Viveiros, M. Dragowsky, E. Druszkiewicz, C. H. Faham, S. Fiorucci, R. J. Gaitskell, K. R. Gibson, C. Hall, M. Hanhardt, B. Holbrook, M. Ihm , et al. (38 additional authors not shown)

    Abstract: Geant4 has been used throughout the nuclear and high-energy physics community to simulate energy depositions in various detectors and materials. These simulations have mostly been run with a source beam outside the detector. In the case of low-background physics, however, a primary concern is the effect on the detector from radioactivity inherent in the detector parts themselves. From this standpo… ▽ More

    Submitted 8 November, 2011; originally announced November 2011.

    Comments: 45 pages, 15 figures

  6. arXiv:1110.0103  [pdf, other

    astro-ph.IM astro-ph.CO

    After LUX: The LZ Program

    Authors: D. C. Malling, D. S. Akerib, H. M. Araujo, X. Bai, S. Bedikian, E. Bernard, A. Bernstein, A. Bradley, S. B. Cahn, M. C. Carmona-Benitez, D. Carr, J. J. Chapman, K. Clark, T. Classen, T. Coffey, A. Curioni, A. Currie, S. Dazeley, L. de Viveiros, M. Dragowsky, E. Druszkiewicz, C. H. Faham, S. Fiorucci, R. J. Gaitskell, K. R. Gibson , et al. (49 additional authors not shown)

    Abstract: The LZ program consists of two stages of direct dark matter searches using liquid Xe detectors. The first stage will be a 1.5-3 tonne detector, while the last stage will be a 20 tonne detector. Both devices will benefit tremendously from research and development performed for the LUX experiment, a 350 kg liquid Xe dark matter detector currently operating at the Sanford Underground Laboratory. In p… ▽ More

    Submitted 13 October, 2011; v1 submitted 1 October, 2011; originally announced October 2011.

    Comments: Conference proceedings from APS DPF 2011. 9 pages, 6 figures

  7. Data Acquisition and Readout System for the LUX Dark Matter Experiment

    Authors: D. S. Akerib, X. Bai, S. Bedikian, E. Bernard, A. Bernstein, A. Bradley, S. B. Cahn, M. C. Carmona-Benitez, D. Carr, J. J. Chapman, K. Clark, T. Classen, T. Coffey, A. Curioni, S. Dazeley, L. deViveiros, M. Dragowsky, E. Druszkiewicz, C. H. Faham, S. Fiorucci, R. J. Gaitskell, K. R. Gibson, C. Hall, M. Hanhardt, B. Holbrook , et al. (38 additional authors not shown)

    Abstract: LUX is a two-phase (liquid/gas) xenon time projection chamber designed to detect nuclear recoils from interactions with dark matter particles. Signals from the LUX detector are processed by custom-built analog electronics which provide properly shaped signals for the trigger and data acquisition (DAQ) systems. The DAQ is comprised of commercial digitizers with firmware customized for the LUX exper… ▽ More

    Submitted 9 August, 2011; v1 submitted 8 August, 2011; originally announced August 2011.

  8. A 83Krm Source for Use in Low-background Liquid Xenon Time Projection Chambers

    Authors: L. W. Kastens, S. Bedikian, S. B. Cahn, A. Manzur, D. N. McKinsey

    Abstract: We report the testing of a charcoal-based Kr-83m source for use in calibrating a low background two-phase liquid xenon detector. Kr-83m atoms produced through the decay of Rb-83 are introduced into a xenon detector by flowing xenon gas past the Rb-83 source. 9.4 keV and 32.1 keV transitions from decaying 83Krm nuclei are detected through liquid xenon scintillation and ionization. The characteristi… ▽ More

    Submitted 29 April, 2010; v1 submitted 11 December, 2009; originally announced December 2009.

    Comments: Updated to version submitted to JINST

    Journal ref: JINST 5:P05006,2010

  9. arXiv:0912.0482  [pdf, ps, other

    astro-ph.CO astro-ph.IM

    Status of the LUX Dark Matter Search

    Authors: S. Fiorucci, D. S. Akerib, S. Bedikian, A. Bernstein, A. Bolozdynya, A. Bradley, D. Carr, J. Chapman, K. Clark, T. Classen, A. Curioni, E. Dahl, S. Dazeley, L. de Viveiros, E. Druszkiewicz, R. Gaitskell, C. Hall, C. Hernandez Faham, B. Holbrook, L. Kastens, K. Kazkaz, R. Lander, K. Lesko, D. Malling, R. Mannino , et al. (22 additional authors not shown)

    Abstract: The Large Underground Xenon (LUX) dark matter search experiment is currently being deployed at the Homestake Laboratory in South Dakota. We will highlight the main elements of design which make the experiment a very strong competitor in the field of direct detection, as well as an easily scalable concept. We will also present its potential reach for supersymmetric dark matter detection, within v… ▽ More

    Submitted 2 December, 2009; originally announced December 2009.

    Comments: 4 pages, in proceedings of the SUSY09 conference

    Journal ref: AIP Conf.Proc.1200:977-980,2010