-
Multichannel-GaAsP-photomultiplier-based fiber bundle ISM-STED microscope
Authors:
Marcus Babin,
Simone Fabian,
Michael Reibe,
Lukas Spantzel,
Michael Börsch,
Erik Beckert
Abstract:
The usage of a GaAsP (gallium arsenide phosphide) photomultiplier for microscopical imaging allows the evaluation of low-light luminescent objects. We designed a setup for collecting a confocal microscopic image signal, which is divided into 14 equal-sized input channels. The division is achieved with a beamsplitter and two fiber bundles consisting of seven fibers each. Re-imaging the confocal pin…
▽ More
The usage of a GaAsP (gallium arsenide phosphide) photomultiplier for microscopical imaging allows the evaluation of low-light luminescent objects. We designed a setup for collecting a confocal microscopic image signal, which is divided into 14 equal-sized input channels. The division is achieved with a beamsplitter and two fiber bundles consisting of seven fibers each. Re-imaging the confocal pinhole by such a densely packed fiber bundle permits the utilization of a photon re-localization approach to overcome the optical resolution limit. The center fiber creates a real-time image, while the outer fibers enable a higher-resolution image via an image scanning microscope (ISM) signal calculation. The fiber bundles are enclosed in a fused silica capillary and are drawn out to create one solid fiber bundle. During the drawing process, the fiber bundles are tapered down to an outer diameter size of 400 μm, with each fiber having a less than 0.3 Airy unit diameter. For the photomultiplier interface, all fibers of both fiber bundles are integrated into a v-groove array, with each fiber representing a detection input, which is followed by projection optics for imaging onto the multichannel detector. The resulting confocal super-resolution microscope is suitable for the application of time-correlated single photon counting (TCSPC) techniques such as fluorescence lifetime imaging (FLIM), time-resolved anisotropy, or Förster resonance energy transfer (FRET) imaging.
△ Less
Submitted 19 April, 2024; v1 submitted 18 April, 2024;
originally announced April 2024.
-
Space QUEST mission proposal: Experimentally testing decoherence due to gravity
Authors:
Siddarth Koduru Joshi,
Jacques Pienaar,
Timothy C. Ralph,
Luigi Cacciapuoti,
Will McCutcheon,
John Rarity,
Dirk Giggenbach,
** Gyu Lim,
Vadim Makarov,
Ivette Fuentes,
Thomas Scheidl,
Erik Beckert,
Mohamed Bourennane,
David Edward Bruschi,
Adan Cabello,
Jose Capmany,
Alberto Carrasco-Casado,
Eleni Diamanti,
Miloslav Duusek,
Dominique Elser,
Angelo Gulinatti,
Robert H. Hadfield,
Thomas Jennewein,
Rainer Kaltenbaek,
Michael A. Krainak
, et al. (20 additional authors not shown)
Abstract:
Models of quantum systems on curved space-times lack sufficient experimental verification. Some speculative theories suggest that quantum properties, such as entanglement, may exhibit entirely different behavior to purely classical systems. By measuring this effect or lack thereof, we can test the hypotheses behind several such models. For instance, as predicted by Ralph and coworkers [T C Ralph,…
▽ More
Models of quantum systems on curved space-times lack sufficient experimental verification. Some speculative theories suggest that quantum properties, such as entanglement, may exhibit entirely different behavior to purely classical systems. By measuring this effect or lack thereof, we can test the hypotheses behind several such models. For instance, as predicted by Ralph and coworkers [T C Ralph, G J Milburn, and T Downes, Phys. Rev. A, 79(2):22121, 2009, T C Ralph and J Pienaar, New Journal of Physics, 16(8):85008, 2014], a bipartite entangled system could decohere if each particle traversed through a different gravitational field gradient. We propose to study this effect in a ground to space uplink scenario. We extend the above theoretical predictions of Ralph and coworkers and discuss the scientific consequences of detecting/failing to detect the predicted gravitational decoherence. We present a detailed mission design of the European Space Agency's (ESA) Space QUEST (Space - Quantum Entanglement Space Test) mission, and study the feasibility of the mission schema.
△ Less
Submitted 9 January, 2018; v1 submitted 23 March, 2017;
originally announced March 2017.
-
PEPSI: The high-resolution echelle spectrograph and polarimeter for the Large Binocular Telescope
Authors:
K. G. Strassmeier,
I. Ilyin,
A. Järvinen,
M. Weber,
M. Woche,
S. I. Barnes,
S. -M. Bauer,
E. Beckert,
W. Bittner,
R. Bredthauer,
T. A. Carroll,
C. Denker,
F. Dionies,
I. DiVarano,
D. Döscher,
T. Fechner,
D. Feuerstein,
T. Granzer,
T. Hahn,
G. Harnisch,
A. Hofmann,
M. Lesser,
J. Paschke,
S. Pankratow,
V. Plank
, et al. (4 additional authors not shown)
Abstract:
PEPSI is the bench-mounted, two-arm, fibre-fed and stabilized Potsdam Echelle Polarimetric and Spectroscopic Instrument for the 2x8.4 m Large Binocular Telescope (LBT). Three spectral resolutions of either 43 000, 120 000 or 270 000 can cover the entire optical/red wavelength range from 383 to 907 nm in three exposures. Two 10.3kx10.3k CCDs with 9-μm pixels and peak quantum efficiencies of 96 % re…
▽ More
PEPSI is the bench-mounted, two-arm, fibre-fed and stabilized Potsdam Echelle Polarimetric and Spectroscopic Instrument for the 2x8.4 m Large Binocular Telescope (LBT). Three spectral resolutions of either 43 000, 120 000 or 270 000 can cover the entire optical/red wavelength range from 383 to 907 nm in three exposures. Two 10.3kx10.3k CCDs with 9-μm pixels and peak quantum efficiencies of 96 % record a total of 92 echelle orders. We introduce a new variant of a wave-guide image slicer with 3, 5, and 7 slices and peak efficiencies between 96 %. A total of six cross dispersers cover the six wavelength settings of the spectrograph, two of them always simultaneously. These are made of a VPH-grating sandwiched by two prisms. The peak efficiency of the system, including the telescope, is 15% at 650 nm, and still 11% and 10% at 390 nm and 900 nm, respectively. In combination with the 110 m2 light-collecting capability of the LBT, we expect a limiting magnitude of 20th mag in V in the low-resolution mode. The R=120 000 mode can also be used with two, dual-beam Stokes IQUV polarimeters. The 270 000-mode is made possible with the 7-slice image slicer and a 100- μm fibre through a projected sky aperture of 0.74", comparable to the median seeing of the LBT site. The 43000-mode with 12-pixel sampling per resolution element is our bad seeing or faint-object mode. Any of the three resolution modes can either be used with sky fibers for simultaneous sky exposures or with light from a stabilized Fabry-Perot etalon for ultra-precise radial velocities. CCD-image processing is performed with the dedicated data-reduction and analysis package PEPSI-S4S. A solar feed makes use of PEPSI during day time and a 500-m feed from the 1.8 m VATT can be used when the LBT is busy otherwise. In this paper, we present the basic instrument design, its realization, and its characteristics.
△ Less
Submitted 24 May, 2015;
originally announced May 2015.