Ensuring Solution Uniqueness in Fixed-Point-Based Harmonic Power Flow Analysis with Converter-Interfaced Resources: Ex-post Conditions
Authors:
Antonio Di Pasquale,
Johanna Kristin Maria Becker,
Andreas Martin Kettner,
Mario Paolone
Abstract:
Recently, the authors of this paper proposed a method for the Harmonic Power-Flow (HPF) calculus in polyphase grids with widespread deployment of Converter-Interfaced Distributed Energy Resources (CIDERs). The HPF problem was formulated by integrating the hybrid nodal equations of the grid with a detailed representation of the CIDERs hardware, sensing, and controls as Linear Time-Periodic (LTP) sy…
▽ More
Recently, the authors of this paper proposed a method for the Harmonic Power-Flow (HPF) calculus in polyphase grids with widespread deployment of Converter-Interfaced Distributed Energy Resources (CIDERs). The HPF problem was formulated by integrating the hybrid nodal equations of the grid with a detailed representation of the CIDERs hardware, sensing, and controls as Linear Time-Periodic (LTP) systems, and solving the resulting mismatch equations using the Newton-Raphson (NR) method. This work introduces a novel problem formulation based on the fixed-point algorithm that, combined with the contraction property of the HPF problem, provides insights into the uniqueness of its solution. Notably, the effectiveness of the fixed-point formulation and the uniqueness of the solution are evaluated through numerical analyses conducted on a modified version of the CIGRE low-voltage benchmark microgrid.
△ Less
Submitted 19 March, 2024;
originally announced March 2024.
-
Harmonic Power-Flow Study of Hybrid AC/DC Grids with Converter-Interfaced Distributed Energy Resources
Authors:
Johanna Kristin Maria Becker,
Andreas Martin Kettner,
Yihui Zuo,
Mario Paolone
Abstract:
As the share of Converter-Interfaced Distributed Energy Resources (CIDERs) in power distribution systems increases, hybrid AC/DC distribution systems are drawing more interest. Indeed, CIDERs usually rely on DC power and hybrid AC/DC grids with few Network-Interfacing Converters (NICs) are a promising solution to decrease installation costs and conversion losses compared to a pure AC grid. However…
▽ More
As the share of Converter-Interfaced Distributed Energy Resources (CIDERs) in power distribution systems increases, hybrid AC/DC distribution systems are drawing more interest. Indeed, CIDERs usually rely on DC power and hybrid AC/DC grids with few Network-Interfacing Converters (NICs) are a promising solution to decrease installation costs and conversion losses compared to a pure AC grid. However, interactions between the AC and DC subsystem of a hybrid AC/DC grid can lead to undesirable amplification and propagation of harmonics. The authors of this paper have recently proposed a Harmonic Power-Flow (HPF) method that accurately represents the AC power flows including the coupling between different harmonics. The HPF framework is formulated through the mismatch equations of the nodal equations between the grid and the resource models and solved by a Newton Raphson algorithm. This paper updates the HPF method to model hybrid AC/DC grids interconnected through NICs. To this end, the model of the NICs and the resulting coupling between the AC and DC subsystems is included in the mismatch equations and the Jacobian matrix of the algorithm. The updated HPF method is applied to a typical hybrid AC/DC grid, and its accuracy is validated through detailed time-domain simulations with Simulink.
△ Less
Submitted 6 February, 2023;
originally announced February 2023.
-
Modelling of AC/DC Interactions of Converter-Interfaced Resources for Harmonic Power-Flow Studies in Microgrids
Authors:
Johanna Kristin Maria Becker,
Andreas Martin Kettner,
Yihui Zuo,
Federico Cecati,
Sante Pugliese,
Marco Liserre,
Mario Paolone
Abstract:
Power distribution systems experience a large-scale integration of Converter-Interfaced Distributed Energy Resources (CIDERs). As acknowledged by recent literature, the interaction of individual CIDER components and different CIDERs through the grid can lead to undesirable amplification of harmonic frequencies and, ultimately, compromise the distribution system stability. In this context, the inte…
▽ More
Power distribution systems experience a large-scale integration of Converter-Interfaced Distributed Energy Resources (CIDERs). As acknowledged by recent literature, the interaction of individual CIDER components and different CIDERs through the grid can lead to undesirable amplification of harmonic frequencies and, ultimately, compromise the distribution system stability. In this context, the interaction of the DC and AC sides of CIDERs has been shown to have a significant impact. In order to analyze and support the mitigation of such phenomena, the authors of this paper recently proposed a Harmonic Power-Flow (HPF) framework for polyphase grids with a high share of CIDERs. The framework considers the coupling between harmonics, but ignores the DC-side response of the CIDERs. Modelling the DC side and AC/DC converter introduces a nonlinearity into the CIDER model that needs to be approximated for the numerical solution of the HPF. This paper extends the CIDER model and HPF framework to address this aspect, whose inclusion is non-trivial. The extended HPF method is applied to a modified version of the CIGRE low-voltage benchmark microgrid. The results are compared to (i) time-domain simulations with Simulink, (ii) the predecessor of the extended HPF which neglects the DC side, and (iii) a classical decoupled HPF.
△ Less
Submitted 21 October, 2022; v1 submitted 15 June, 2022;
originally announced June 2022.
-
Harmonic Power-Flow Study of Polyphase Grids with Converter-Interfaced Distributed Energy Resources, Part II: Model Library and Validation
Authors:
Johanna Kristin Maria Becker,
Andreas Martin Kettner,
Lorenzo Reyes-Chamorro,
Zhixiang Zou,
Marco Liserre,
Mario Paolone
Abstract:
In Part I, a method for the Harmonic Power-Flow (HPF) study of three-phase power grids with Converter-Interfaced Distributed Energy Resources (CIDERs) is proposed. The method is based on generic and modular representations of the grid and the CIDERs, and explicitly accounts for coupling between harmonics. In Part II, the HPF method is validated. First, the applicability of the modeling framework i…
▽ More
In Part I, a method for the Harmonic Power-Flow (HPF) study of three-phase power grids with Converter-Interfaced Distributed Energy Resources (CIDERs) is proposed. The method is based on generic and modular representations of the grid and the CIDERs, and explicitly accounts for coupling between harmonics. In Part II, the HPF method is validated. First, the applicability of the modeling framework is demonstrated on typical grid-forming and grid-following CIDERs. Then, the HPF method is implemented in Matlab and compared against time-domain simulations with Simulink. The accuracy of the models and the performance of the solution algorithm are assessed for individual resources and a modified version of the CIGRÉ low-voltage benchmark microgrid (i.e., with additional unbalanced components). The observed maximum errors are 6.3E-5 p.u. w.r.t. voltage magnitude, 1.3E-3 p.u. w.r.t. current magnitude, and 0.9 deg w.r.t. phase. Moreover, the scalability of the method is assessed w.r.t. the number of CIDERs and the maximum harmonic order ($\leqslant$25). For the maximum problem size, the execution time of the HPF method is 6.52 sec, which is 5 times faster than the time-domain simulation. The convergence of the method is robust w.r.t. the choice of the initial point, and multiplicity of solutions has not been observed.
△ Less
Submitted 1 November, 2021; v1 submitted 23 June, 2021;
originally announced June 2021.
-
Harmonic Power-Flow Study of Polyphase Grids with Converter-Interfaced Distributed Energy Resources, Part I: Modelling Framework and Algorithm
Authors:
Andreas Martin Kettner,
Lorenzo Reyes-Chamorro,
Johanna Kristin Maria Becker,
Zhixiang Zou,
Marco Liserre,
Mario Paolone
Abstract:
Power distribution systems are experiencing a large-scale integration of Converter-Interfaced Distributed Energy Resources (CIDERs). This complicates the analysis and mitigation of harmonics, whose creation and propagation are facilitated by the interactions of converters and their controllers through the grid. In this paper, a method for the calculation of the so-called Harmonic Power-Flow (HPF)…
▽ More
Power distribution systems are experiencing a large-scale integration of Converter-Interfaced Distributed Energy Resources (CIDERs). This complicates the analysis and mitigation of harmonics, whose creation and propagation are facilitated by the interactions of converters and their controllers through the grid. In this paper, a method for the calculation of the so-called Harmonic Power-Flow (HPF) in three-phase grids with CIDERs is proposed. The distinguishing feature of this HPF method is the generic and modular representation of the system components. Notably, as opposed to most of the existing approaches, the coupling between harmonics is explicitly considered. The HPF problem is formulated by combining the hybrid nodal equations of the grid with the closed-loop transfer functions of the CIDERs, and solved using the Newton-Raphson method. The grid components are characterized by compound electrical parameters, which allow to represent both transposed or non-transposed lines. The CIDERs are represented by modular linear time-periodic systems, which allows to treat both grid-forming and grid-following control laws. The method's accuracy and computational efficiency are confirmed via time-domain simulations of the CIGRÉ low-voltage benchmark microgrid. This paper is divided in two parts, which focus on the development (Part I) and the validation (Part II) of the proposed method.
△ Less
Submitted 1 November, 2021; v1 submitted 23 June, 2021;
originally announced June 2021.
-
Discovery of Radio Emission from the Brown Dwarf LP944-20
Authors:
E. Berger,
S. Ball,
K. M. Becker,
M. Clarke,
D. A. Frail,
T. A. Fukuda,
I. M. Hoffman,
S. R. Kulkarni,
R. Mellon,
E. Momjian,
N. W. Murphy,
S. H. Teng,
T. Woodruff,
B. A. Zauderer,
R. T. Zavala
Abstract:
Brown dwarfs are classified as objects which are not massive enough to sustain nuclear fusion of hydrogen, and are distinguished from planets by their ability to burn deuterium. Old (>10 Myr) brown dwarfs are expected to possess short-lived magnetic fields and, since they no longer generate energy from collapse and accretion, weak radio and X-ray emitting coronae. Several efforts have been under…
▽ More
Brown dwarfs are classified as objects which are not massive enough to sustain nuclear fusion of hydrogen, and are distinguished from planets by their ability to burn deuterium. Old (>10 Myr) brown dwarfs are expected to possess short-lived magnetic fields and, since they no longer generate energy from collapse and accretion, weak radio and X-ray emitting coronae. Several efforts have been undertaken in the past to detect chromospheric activity from the brown dwarf LP944-20 at X-ray and optical wavelengths, but only recently an X-ray flare from this object was detected. Here we report on the discovery of quiescent and flaring radio emission from this source, which represents the first detection of persistent radio emission from a brown dwarf, with luminosities that are several orders of magnitude larger than predicted from an empirical relation between the X-ray and radio luminosities of many stellar types. We show in the context of synchrotron emission, that LP944-20 possesses an unusually weak magnetic field in comparison to active dwarf M stars, which might explain the null results from previous optical and X-ray observations of this source, and the deviation from the empirical relations.
△ Less
Submitted 16 February, 2001;
originally announced February 2001.
-
GRB 000418: A Hidden Jet Revealed?
Authors:
E. Berger,
A. Diercks,
D. A. Frail,
S. R. Kulkarni,
J. S. Bloom,
R. Sari,
J. Halpern,
N. Mirabal,
G. B. Taylor,
K. Hurley,
G. Pooley,
K. M. Becker,
R. M. Wagner,
D. M. Terndrup,
T. Statler,
E. Mazets,
T. Cline
Abstract:
We report on optical, near-infrared and centimeter radio observations of GRB000418 which allow us to follow the evolution of the afterglow from 2 to 200 days after the gamma-ray burst. In modeling these broad-band data, we find that an isotropic explosion in a constant density medium is unable to simultaneously fit both the radio and optical data. However, a jet-like outflow with an opening angl…
▽ More
We report on optical, near-infrared and centimeter radio observations of GRB000418 which allow us to follow the evolution of the afterglow from 2 to 200 days after the gamma-ray burst. In modeling these broad-band data, we find that an isotropic explosion in a constant density medium is unable to simultaneously fit both the radio and optical data. However, a jet-like outflow with an opening angle of 10-20 degress provides a good description of the data. The evidence in favor of a jet interpretation is based on the behavior of the radio light curves, since the expected jet break is masked at optical wavelengths by the light of the host galaxy. We also find evidence for extinction, presumably arising from within the host galaxy, with A(V)=0.4 mag, and host flux densities of F_R=1.1 uJy and F_K=1.7 uJy. These values supercede previous work on this burst due to the availability of a broad-band data set allowing a global fitting approach. A model in which the GRB explodes into a wind-stratified circumburst medium cannot be ruled out by these data. However, in examining a sample of other bursts (e.g. GRB990510, GRB000301C) we favor the jet interpretation for GRB000418.
△ Less
Submitted 15 February, 2001;
originally announced February 2001.
-
Faint Scattering Around Pulsars: Probing the Interstellar Medium on Solar System Size Scales
Authors:
D. R. Stinebring,
M. A. McLaughlin,
J. M. Cordes,
K. M. Becker,
J. E. Espinoza Goodman,
M. A. Kramer,
J. L. Sheckard,
T. C. T. Smith
Abstract:
We have made high-resolution, high-sensitivity dynamic spectra of a sample of strong pulsars at 430 MHz with the Arecibo radiotelescope. For 4 pulsars we find faint but sharply delineated features in the secondary spectra. These are examples of the previously observed ``crisscross'' or ``multiple drift slope'' phenomenon presumed to be due to multiple imaging of the pulsar by the interstellar me…
▽ More
We have made high-resolution, high-sensitivity dynamic spectra of a sample of strong pulsars at 430 MHz with the Arecibo radiotelescope. For 4 pulsars we find faint but sharply delineated features in the secondary spectra. These are examples of the previously observed ``crisscross'' or ``multiple drift slope'' phenomenon presumed to be due to multiple imaging of the pulsar by the interstellar medium. The unprecedented resolution and dynamic range of our observations allow a deeper level of analysis. Distances to the dominant scattering screen along the line of sight are determined and are shown to agree well with those inferred from other scintillation phenomena. Multiple imaging of the pulsar by the ISM is required. A compact central image surrounded by a faint scattering halo, roughly circularly symmetric, is consistent with the data. Scattering from filaments may also be consistent. The angular extent of the scattering material parallel to the direction of the pulsar velocity is roughly 5 mas, corresponding to a linear extent of about 2 AU. Further observations of these features should allow better discrimination between models and an identification of the scattering structures.
△ Less
Submitted 15 December, 2000; v1 submitted 18 October, 2000;
originally announced October 2000.