Ultrathin, high-speed, all-optical photoacoustic endomicroscopy probe for guiding minimally invasive surgery
Authors:
Tianrui Zhao,
Truc Thuy Pham,
Christian Baker,
Michelle T. Ma,
Sebastien Ourselin,
Tom Vercauteren,
Edward Zhang,
Paul C. Beard,
Wenfeng Xia
Abstract:
Photoacoustic (PA) endoscopy has shown significant potential for clinical diagnosis and surgical guidance. Multimode fibres (MMFs) are becoming increasing attractive for the development of miniature endoscopy probes owing to ultrathin size, low cost and diffraction-limited spatial resolution enabled by wavefront sha**. However, current MMF-based PA endomicroscopy probes are either limited by a b…
▽ More
Photoacoustic (PA) endoscopy has shown significant potential for clinical diagnosis and surgical guidance. Multimode fibres (MMFs) are becoming increasing attractive for the development of miniature endoscopy probes owing to ultrathin size, low cost and diffraction-limited spatial resolution enabled by wavefront sha**. However, current MMF-based PA endomicroscopy probes are either limited by a bulky ultrasound detector or a low imaging speed which hindered their usability. In this work, we report the development of a highly miniaturised and high-speed PA endomicroscopy probe that is integrated within the cannula of a 20 gauge medical needle. This probe comprises a MMF for delivering the PA excitation light and a single-mode optical fibre with a plano-concave microresonator for ultrasound detection. Wavefront sha** with a digital micromirror device enabled rapid raster-scanning of a focused light spot at the distal end of the MMF for tissue interrogation. High-resolution PA imaging of mouse red blood cells covering an area 100 microns in diameter was achieved with the needle probe at ~3 frames per second. Mosaicing imaging was performed after fibre characterisation by translating the needle probe to enlarge the field-of-view in real-time. The developed ultrathin PA endomicroscopy probe is promising for guiding minimally invasive surgery by providing functional, molecular and microstructural information of tissue in real-time.
△ Less
Submitted 6 May, 2022;
originally announced May 2022.
-
Photoacoustic Reconstruction Using Sparsity in Curvelet Frame: Image versus Data Domain
Authors:
Bolin Pan,
Simon R. Arridge,
Felix Lucka,
Ben T. Cox,
Nam Huynh,
Paul C. Beard,
Edward Z. Zhang,
Marta M. Betcke
Abstract:
Curvelet frame is of special significance for photoacoustic tomography (PAT) due to its sparsifying and microlocalisation properties. We derive a one-to-one map between wavefront directions in image and data spaces in PAT which suggests near equivalence between the recovery of the initial pressure and PAT data from compressed/subsampled measurements when assuming sparsity in Curvelet frame. As the…
▽ More
Curvelet frame is of special significance for photoacoustic tomography (PAT) due to its sparsifying and microlocalisation properties. We derive a one-to-one map between wavefront directions in image and data spaces in PAT which suggests near equivalence between the recovery of the initial pressure and PAT data from compressed/subsampled measurements when assuming sparsity in Curvelet frame. As the latter is computationally more tractable, investigation to which extent this equivalence holds conducted in this paper is of immediate practical significance. To this end we formulate and compare DR, a two step approach based on the recovery of the complete volume of the photoacoustic data from the subsampled data followed by the acoustic inversion, and p0R, a one step approach where the photoacoustic image (the initial pressure, p0) is directly recovered from the subsampled data. Effective representation of the photoacoustic data requires basis defined on the range of the photoacoustic forward operator. To this end we propose a novel wedge-restriction of Curvelet transform which enables us to construct such basis. Both recovery problems are formulated in a variational framework. As the Curvelet frame is heavily overdetermined, we use reweighted l1 norm penalties to enhance the sparsity of the solution. The data reconstruction problem DR is a standard compressed sensing recovery problem, which we solve using an ADMMtype algorithm, SALSA. Subsequently, the initial pressure is recovered using time reversal as implemented in the k-Wave Toolbox. The p0 reconstruction problem, p0R, aims to recover the photoacoustic image directly via FISTA, or ADMM when in addition including a non-negativity constraint. We compare and discuss the relative merits of the two approaches and illustrate them on 2D simulated and 3D real data in a fair and rigorous manner.
△ Less
Submitted 6 August, 2021; v1 submitted 25 November, 2020;
originally announced November 2020.
-
Single-shot hybrid photoacoustic-fluorescent microendoscopy through a multi-mode fiber with wavefront sha**
Authors:
Sylvain Mezil,
Antonio M. Caravaca-Aguirre,
Edward Z. Zhang,
Philippe Moreau,
Irène Wang,
Paul C. Beard,
Emmanuel Bossy
Abstract:
We present a minimally-invasive endoscope based on a multimode fiber that combines photoacoustic and fluorescence sensing. From the measurement of a transmission matrix during a prior calibration step, a focused spot is produced and raster-scanned over a sample at the distal tip of the fiber by use of a fast spatial light modulator. An ultra-sensitive fiber-optic ultrasound sensor for photoacousti…
▽ More
We present a minimally-invasive endoscope based on a multimode fiber that combines photoacoustic and fluorescence sensing. From the measurement of a transmission matrix during a prior calibration step, a focused spot is produced and raster-scanned over a sample at the distal tip of the fiber by use of a fast spatial light modulator. An ultra-sensitive fiber-optic ultrasound sensor for photoacoustic detection placed next to the fiber is combined with a photodetector to obtain both fluorescence and photoacoustic images with a distal imaging tip no larger than 250um. The high signal-to-noise ratio provided by wavefront sha** based focusing and the ultra-sensitive ultrasound sensor enables imaging with a single laser shot per pixel, demonstrating fast two-dimensional hybrid imaging of red blood cells and fluorescent beads.
△ Less
Submitted 18 June, 2020;
originally announced June 2020.
-
Acoustic Wave Field Reconstruction from Compressed Measurements with Application in Photoacoustic Tomography
Authors:
Marta M. Betcke,
Ben T. Cox,
Nam Huynh,
Edward Z. Zhang,
Paul C. Beard,
Simon R. Arridge
Abstract:
We present a method for the recovery of compressively sensed acoustic fields using patterned, instead of point-by-point, detection. From a limited number of such compressed measurements, we propose to reconstruct the field on the sensor plane in each time step independently assuming its sparsity in a Curvelet frame. A modification of the Curvelet frame is proposed to account for the smoothing effe…
▽ More
We present a method for the recovery of compressively sensed acoustic fields using patterned, instead of point-by-point, detection. From a limited number of such compressed measurements, we propose to reconstruct the field on the sensor plane in each time step independently assuming its sparsity in a Curvelet frame. A modification of the Curvelet frame is proposed to account for the smoothing effects of data acquisition and motivated by a frequency domain model for photoacoustic tomography. An ADMM type algorithm, SALSA, is used to recover the pointwise data in each individual time step from the patterned measurements. For photoacoustic applications, the photoacoustic image of the initial pressure is reconstructed using time reversal in ${\bf k}$-Wave Toolbox.
△ Less
Submitted 9 September, 2016;
originally announced September 2016.