-
Status and initial physics performance studies of the MPD experiment at NICA
Authors:
MPD Collaboration,
V. Abgaryan,
R. Acevedo Kado,
S. V. Afanasyev,
G. N. Agakishiev,
E. Alpatov,
G. Altsybeev,
M. Alvarado Hernández,
S. V. Andreeva,
T. V. Andreeva,
E. V. Andronov,
N. V. Anfimov,
A. A. Aparin,
V. I. Astakhov,
E. Atkin,
T. Aushev,
G. S. Averichev,
A. V. Averyanov,
A. Ayala,
V. A. Babkin,
T. Babutsidze,
I. A. Balashov,
A. Bancer,
M. Yu. Barabanov,
D. A. Baranov
, et al. (454 additional authors not shown)
Abstract:
The Nuclotron-base Ion Collider fAcility (NICA) is under construction at the Joint Institute for Nuclear Research (JINR), with commissioning of the facility expected in late 2022. The Multi-Purpose Detector (MPD) has been designed to operate at NICA and its components are currently in production. The detector is expected to be ready for data taking with the first beams from NICA. This document pro…
▽ More
The Nuclotron-base Ion Collider fAcility (NICA) is under construction at the Joint Institute for Nuclear Research (JINR), with commissioning of the facility expected in late 2022. The Multi-Purpose Detector (MPD) has been designed to operate at NICA and its components are currently in production. The detector is expected to be ready for data taking with the first beams from NICA. This document provides an overview of the landscape of the investigation of the QCD phase diagram in the region of maximum baryonic density, where NICA and MPD will be able to provide significant and unique input. It also provides a detailed description of the MPD set-up, including its various subsystems as well as its support and computing infrastructures. Selected performance studies for particular physics measurements at MPD are presented and discussed in the context of existing data and theoretical expectations.
△ Less
Submitted 16 February, 2022;
originally announced February 2022.
-
First results on the measurements of the proton beam polarization at internal target at Nuclotron
Authors:
V. P. Ladygin,
Yu. V. Gurchin,
A. Yu. Isupov,
M. Janek,
A. N. Khrenov,
P. K. Kurilkin,
A. N. Livanov,
S. M. Piyadin,
S. G. Reznikov,
Ya. T. Skhomenko,
A. A. Terekhin,
A. V. Tishevsky,
A. V. Averyanov,
S. N. Bazylev,
A. S. Belov,
A. V. Butenko,
E. V. Chernykh,
Yu. N. Filatov,
V. V. Fimushkin,
D. O. Krivenkov,
A. M. Kondratenko,
M. A. Kondratenko,
A. D. Kovalenko,
I. V. Slepnev,
V. M. Slepnev
, et al. (4 additional authors not shown)
Abstract:
The spin program at NICA using SPD and MPD requires high intensity polarized proton beam with high value of the beam polarization. First results on the measurements of the proton beam polarization performed at internal target at Nuclotron are reported. The polarization of the proton beam provided by new source of polarized ions has been measured at 500 MeV using quasielastic proton-proton scatteri…
▽ More
The spin program at NICA using SPD and MPD requires high intensity polarized proton beam with high value of the beam polarization. First results on the measurements of the proton beam polarization performed at internal target at Nuclotron are reported. The polarization of the proton beam provided by new source of polarized ions has been measured at 500 MeV using quasielastic proton-proton scattering and DSS setup at internal target. The obtained value of the vertical polarization of ~35 % is consistent with the calculations taking into account the current magnetic optics of the Nuclotron injection line.
△ Less
Submitted 8 November, 2017;
originally announced November 2017.
-
Development of the MRPC for the TOF system of the MultiPurpose Detector
Authors:
V. A. Babkin,
S. N. Bazylev,
I. S. Burdenyuk,
M. G. Buryakov,
A. V. Dmitriev,
P. O. Dulov,
V. M. Golovatyuk,
S. P. Lobastov,
M. M. Rumyantsev,
A. V. Schipunov,
A. V. Shutov,
I. V. Slepnev,
V. M. Slepnev,
A. V. Terletskiy,
S. V. Volgin
Abstract:
The Multipurpose Detector (MPD) \cite{cite1.MPD_CDR} is designed to study of hot and dense baryonic matter in collisions of heavy ions over the atomic mass range 1--197 at the centre of mass energy up to $\sqrt{S_{NN}}$ = 11 GeV (for Au79+). The MPD experiment will be carried out at the JINR accelerator complex NICA \cite{cite2.NICA_CDR} which is under construction. The barrel part of the MPD cons…
▽ More
The Multipurpose Detector (MPD) \cite{cite1.MPD_CDR} is designed to study of hot and dense baryonic matter in collisions of heavy ions over the atomic mass range 1--197 at the centre of mass energy up to $\sqrt{S_{NN}}$ = 11 GeV (for Au79+). The MPD experiment will be carried out at the JINR accelerator complex NICA \cite{cite2.NICA_CDR} which is under construction. The barrel part of the MPD consists of various detectors surrounding the interaction point. It includes a precise tracking system (time projection chamber (TPC) and silicon inner tracker (IT)) and high-performance particle identification system based on time-of-flight (TOF) and calorimeter (ECal). The triple-stack multigap resistive plate chamber is chosen as an active element of the TOF. It provides good time resolution and long term stability.
This article presents parameters of the MRPC obtained using the deuteron beam of JINR accelerator Nuclotron. The time resolution is $\sim$40 ps with efficiency of 99\%. Rate capability studies resulted with a time resolution of 60 ps and efficiency higher than 90\% on the beam with particle flux densities up to 2 kHz/cm$^2$.
△ Less
Submitted 6 June, 2016;
originally announced June 2016.
-
Construction and Commissioning of the CALICE Analog Hadron Calorimeter Prototype
Authors:
C. Adloff,
Y. Karyotakis,
J. Repond,
A. Brandt,
H. Brown,
K. De,
C. Medina,
J. Smith,
J. Li,
M. Sosebee,
A. White,
J. Yu,
T. Buanes,
G. Eigen,
Y. Mikami,
O. Miller,
N. K. Watson,
J. A. Wilson,
T. Goto,
G. Mavromanolakis,
M. A. Thomson,
D. R. Ward,
W. Yan,
D. Benchekroun,
A. Hoummada
, et al. (205 additional authors not shown)
Abstract:
An analog hadron calorimeter (AHCAL) prototype of 5.3 nuclear interaction lengths thickness has been constructed by members of the CALICE Collaboration. The AHCAL prototype consists of a 38-layer sandwich structure of steel plates and highly-segmented scintillator tiles that are read out by wavelength-shifting fibers coupled to SiPMs. The signal is amplified and shaped with a custom-designed ASIC.…
▽ More
An analog hadron calorimeter (AHCAL) prototype of 5.3 nuclear interaction lengths thickness has been constructed by members of the CALICE Collaboration. The AHCAL prototype consists of a 38-layer sandwich structure of steel plates and highly-segmented scintillator tiles that are read out by wavelength-shifting fibers coupled to SiPMs. The signal is amplified and shaped with a custom-designed ASIC. A calibration/monitoring system based on LED light was developed to monitor the SiPM gain and to measure the full SiPM response curve in order to correct for non-linearity. Ultimately, the physics goals are the study of hadron shower shapes and testing the concept of particle flow. The technical goal consists of measuring the performance and reliability of 7608 SiPMs. The AHCAL was commissioned in test beams at DESY and CERN. The entire prototype was completed in 2007 and recorded hadron showers, electron showers and muons at different energies and incident angles in test beams at CERN and Fermilab.
△ Less
Submitted 12 March, 2010;
originally announced March 2010.