Skip to main content

Showing 1–4 of 4 results for author: Battu, S

.
  1. arXiv:1211.0960  [pdf, other

    hep-ex nucl-ex physics.ins-det

    Detailed Report of the MuLan Measurement of the Positive Muon Lifetime and Determination of the Fermi Constant

    Authors: V. Tishchenko, S. Battu, R. M. Carey, D. B. Chitwood, J. Crnkovic, P. T. Debevec, S. Dhamija, W. Earle, A. Gafarov, K. Giovanetti, T. P. Gorringe, F. E. Gray, Z. Hartwig, D. W. Hertzog, B. Johnson, P. Kammel, B. Kiburg, S. Kizilgul, J. Kunkle, B. Lauss, I. Logashenko, K. R. Lynch, R. McNabb, J. P. Miller, F. Mulhauser , et al. (8 additional authors not shown)

    Abstract: We present a detailed report of the method, setup, analysis and results of a precision measurement of the positive muon lifetime. The experiment was conducted at the Paul Scherrer Institute using a time-structured, nearly 100%-polarized, surface muon beam and a segmented, fast-timing, plastic scintillator array. The measurement employed two target arrangements; a magnetized ferromagnetic target wi… ▽ More

    Submitted 5 November, 2012; originally announced November 2012.

    Comments: Submitted for publication in Phys. Rev. D (32 pages, 28 figures, 5 tables)

  2. Measurement of the Positive Muon Lifetime and Determination of the Fermi Constant to Part-per-Million Precision

    Authors: D. M. Webber, V. Tishchenko, Q. ~Peng, S. Battu, R. M. Carey, D. B. Chitwood, J. Crnkovic, P. T. Debevec, S. Dhamija, W. Earle, A. Gafarov, K. Giovanetti, T. P. Gorringe, F. E. Gray, Z. Hartwig, D. W. Hertzog, B. Johnson, P. Kammel, B. Kiburg, S. Kizilgul, J. Kunkle, B. Lauss, I. Logashenko, K. R. Lynch, R. McNabb , et al. (8 additional authors not shown)

    Abstract: We report a measurement of the positive muon lifetime to a precision of 1.0 parts per million (ppm); it is the most precise particle lifetime ever measured. The experiment used a time-structured, low-energy muon beam and a segmented plastic scintillator array to record more than 2 x 10^{12} decays. Two different stop** target configurations were employed in independent data-taking periods. The c… ▽ More

    Submitted 6 December, 2010; v1 submitted 5 October, 2010; originally announced October 2010.

    Comments: Accepted for publication in Phys. Rev. Lett

    Journal ref: Phys.Rev.Lett.106:041803,2011; Phys.Rev.Lett.106:079901,2011

  3. Data acquisition system for the MuLan muon lifetime experiment

    Authors: V. Tishchenko, S. Battu, S. Cheekatmalla, D. B. Chitwood, S. Dhamija, T. P. Gorringe, F. Gray, K. R. Lynch, I. Logashenko, S. Rath, D. M. Webber

    Abstract: We describe the data acquisition system for the MuLan muon lifetime experiment at Paul Scherrer Institute. The system was designed to record muon decays at rates up to 1 MHz and acquire data at rates up to 60 MB/sec. The system employed a parallel network of dual-processor machines and repeating acquisition cycles of deadtime-free time segments in order to reach the design goals. The system inco… ▽ More

    Submitted 7 February, 2008; originally announced February 2008.

    Comments: 19 pages, 8 figures, submitted to Nuclear Instruments and Methods A

    Journal ref: Nucl.Instrum.Meth.A592:114-122,2008

  4. Improved Measurement of the Positive Muon Lifetime and Determination of the Fermi Constant

    Authors: MuLan Collaboration, D. B. Chitwood, T. I. Banks, M. J. Barnes, S. Battu, R. M. Carey, S. Cheekatmalla, S. M. Clayton, J. Crnkovic, K. M. Crowe, P. T. Debevec, S. Dhamija, W. Earle, A. Gafarov, K. Giovanetti, T. P. Gorringe, F. E. Gray, M. Hance, D. W. Hertzog, M. F. Hare, P. Kammel, B. Kiburg, J. Kunkle, B. Lauss, I. Logashenko , et al. (16 additional authors not shown)

    Abstract: The mean life of the positive muon has been measured to a precision of 11 ppm using a low-energy, pulsed muon beam stopped in a ferromagnetic target, which was surrounded by a scintillator detector array. The result, tau_mu = 2.197013(24) us, is in excellent agreement with the previous world average. The new world average tau_mu = 2.197019(21) us determines the Fermi constant G_F = 1.166371(6) x… ▽ More

    Submitted 8 February, 2008; v1 submitted 16 April, 2007; originally announced April 2007.

    Comments: As published version (PRL, July 2007)

    Journal ref: Phys.Rev.Lett.99:032001,2007