On the Positronium g-factor
Authors:
J. Agil,
D. Bakalov,
R. Battesti,
C. Rizzo
Abstract:
In this letter, we recall the main facts concerning the g-factor of positronium and we show how the value of the g-factor of the positronium is important. Taking it better into consideration may provide a solution to the reported discrepancy between QED theory and experiments concerning the hyperfine splitting of the fundamental level of the positronium. We also give the only experimental value th…
▽ More
In this letter, we recall the main facts concerning the g-factor of positronium and we show how the value of the g-factor of the positronium is important. Taking it better into consideration may provide a solution to the reported discrepancy between QED theory and experiments concerning the hyperfine splitting of the fundamental level of the positronium. We also give the only experimental value that existing experiments can provide, $g_{\mathrm{Ps}}=2.0023\pm 0.0012$ at $3σ$.
△ Less
Submitted 31 October, 2023; v1 submitted 26 July, 2023;
originally announced July 2023.
-
Characterisation of the waveplate associated to layers in interferential mirrors
Authors:
J. Agil,
B. Letourneur,
S. George,
R. Battesti,
C. Rizzo
Abstract:
In this paper, first we present a review of experimental data corresponding to phase retardation per reflection of interferential mirrors. Then, we report our new measurements on both commercial and tailor-made mirrors. To be able to measure the phase retardation as a function of the number of layers, additional pairs of layers are deposited on some of the mirrors. The results obtained with this s…
▽ More
In this paper, first we present a review of experimental data corresponding to phase retardation per reflection of interferential mirrors. Then, we report our new measurements on both commercial and tailor-made mirrors. To be able to measure the phase retardation as a function of the number of layers, additional pairs of layers are deposited on some of the mirrors. The results obtained with this special set of mirrors allow us to fully characterise the waveplate associated with the additional pairs of layers. We finally implemented a computational study whose results are compared with the experimental ones. Thanks to the additional layers, we have achieved reflectivity never measured before at $λ=1064$~nm, with an associated finesse of $\mathcal{F}=895~000$.
△ Less
Submitted 26 July, 2023;
originally announced July 2023.
-
On the speed of light in a vacuum in the presence of a magnetic field
Authors:
Jonathan Agil,
Rémy Battesti,
Carlo Rizzo
Abstract:
The nature of light, the existence of magnetism, the physical meaning of a vacuum are problems so deeply related to philosophy that they have been discussed for thousands of years. In this paper, we concentrate ourselves on a question that concerns the three of them: does light speed in a vacuum change when a magnetic field is present? The experimental answer to this fundamental question has not y…
▽ More
The nature of light, the existence of magnetism, the physical meaning of a vacuum are problems so deeply related to philosophy that they have been discussed for thousands of years. In this paper, we concentrate ourselves on a question that concerns the three of them: does light speed in a vacuum change when a magnetic field is present? The experimental answer to this fundamental question has not yet been given even if it has been stated in modern terms for more than a century. To fully understand the importance of such a question in physics, we review the main facts and concepts from the historical point of view.
△ Less
Submitted 6 February, 2023; v1 submitted 1 February, 2023;
originally announced February 2023.
-
A novel pulsed magnet for magnetic linear birefringence measurements
Authors:
J Béard,
Jonathan Agil,
R Battesti,
C Rizzo
Abstract:
In this paper, we describe a novel pulsed magnet, called Foil Coil, which can deliver a field transverse to the light propagation of more than 10 T over about 0.8 meters operating without cryogenic equipment. It has been designed for linear magnetic birefringence measurements. We report on testing the coil, and also show some physics data taken in vacuum during its commissioning in the framework o…
▽ More
In this paper, we describe a novel pulsed magnet, called Foil Coil, which can deliver a field transverse to the light propagation of more than 10 T over about 0.8 meters operating without cryogenic equipment. It has been designed for linear magnetic birefringence measurements. We report on testing the coil, and also show some physics data taken in vacuum during its commissioning in the framework of the BMV apparatus, with special attention to noise induced by the pulse itself. Finally, we compare the preliminary results obtained here, with data from the previous BMV coil.
△ Less
Submitted 6 October, 2021;
originally announced October 2021.
-
Monte Carlo study of the BMV vacuum linear magnetic birefringence experiment
Authors:
Jonathan Agil,
R. Battesti,
C. Rizzo
Abstract:
QED vacuum can be polarized and magnetized by an external electromagnetic field, therefore acting as a birefringent medium. This effect has not yet been measured. In this paper, after having recalled the main facts concerning Vacuum Magnetic Birefringence polarimetry detection method and the related noise sources, we detail our Monte Carlo simulation of a pulsed magnetic field data run. Our Monte…
▽ More
QED vacuum can be polarized and magnetized by an external electromagnetic field, therefore acting as a birefringent medium. This effect has not yet been measured. In this paper, after having recalled the main facts concerning Vacuum Magnetic Birefringence polarimetry detection method and the related noise sources, we detail our Monte Carlo simulation of a pulsed magnetic field data run. Our Monte Carlo results are optimized to match BMV experiment 2014 data. We show that our Monte Carlo approach can reproduce experimental results giving an important insight to the systematic effects limiting experiment sensitivity.
△ Less
Submitted 22 July, 2021;
originally announced July 2021.
-
Characterization of the Vacuum Birefringence Polarimeter at BMV: Dynamical Cavity Mirror Birefringence
Authors:
M. T. Hartman,
R. Battesti,
C. Rizzo
Abstract:
We present the current status and outlook of the optical characterization of the polarimeter at the Biréfringence Magnétique du Vide (BMV) experiment. BMV is a polarimetric search for the QED predicted anisotropy of vacuum in the presence of external electromagnetic fields. The main challenge faced in this fundamental test is the measurement of polarization ellipticity on the order of…
▽ More
We present the current status and outlook of the optical characterization of the polarimeter at the Biréfringence Magnétique du Vide (BMV) experiment. BMV is a polarimetric search for the QED predicted anisotropy of vacuum in the presence of external electromagnetic fields. The main challenge faced in this fundamental test is the measurement of polarization ellipticity on the order of ${10^{-15}}$ induced in linearly polarized laser field per pass through a magnetic field having an amplitude and length ${B^{2}L=100\,\mathrm{T}^{2}\mathrm{m}}$. This challenge is addressed by understanding the noise sources in precision cavity-enhanced polarimetry. In this paper we discuss the first investigation of dynamical birefringence in the signal-enhancing cavity as a result of cavity mirror motion.
△ Less
Submitted 5 January, 2019; v1 submitted 20 December, 2018;
originally announced December 2018.
-
High magnetic fields for fundamental physics
Authors:
Rémy Battesti,
Jerome Beard,
Sebastian Böser,
Nicolas Bruyant,
Dmitry Budker,
Scott A. Crooker,
Edward J. Daw,
Victor V. Flambaum,
Toshiaki Inada,
Igor G. Irastorza,
Felix Karbstein,
Dong Lak Kim,
Mikhail G. Kozlov,
Ziad Melhem,
Arran Phipps,
Pierre Pugnat,
Geert Rikken,
Carlo Rizzo,
Matthias Schott,
Yannis K. Semertzidis,
Herman H. J. ten Kate,
Guido Zavattini
Abstract:
Various fundamental-physics experiments such as measurement of the birefringence of the vacuum, searches for ultralight dark matter (e.g., axions), and precision spectroscopy of complex systems (including exotic atoms containing antimatter constituents) are enabled by high-field magnets. We give an overview of current and future experiments and discuss the state-of-the-art DC- and pulsed-magnet te…
▽ More
Various fundamental-physics experiments such as measurement of the birefringence of the vacuum, searches for ultralight dark matter (e.g., axions), and precision spectroscopy of complex systems (including exotic atoms containing antimatter constituents) are enabled by high-field magnets. We give an overview of current and future experiments and discuss the state-of-the-art DC- and pulsed-magnet technologies and prospects for future developments.
△ Less
Submitted 20 March, 2018;
originally announced March 2018.
-
Noise characterization for resonantly-enhanced polarimetric vacuum magnetic-birefringence experiments
Authors:
M. T. Hartman,
A. Rivere,
R. Battesti,
C. Rizzo
Abstract:
In this work we present data characterizing the sensitivity of the Biréfringence Magnetique du Vide (BMV) instrument. BMV is an experiment attempting to measure vacuum magnetic birefringence (VMB) via the measurement of an ellipticity induced in a linearly polarized laser field propagating through a birefringent region of vacuum in the presence of an external magnetic field. Correlated measurement…
▽ More
In this work we present data characterizing the sensitivity of the Biréfringence Magnetique du Vide (BMV) instrument. BMV is an experiment attempting to measure vacuum magnetic birefringence (VMB) via the measurement of an ellipticity induced in a linearly polarized laser field propagating through a birefringent region of vacuum in the presence of an external magnetic field. Correlated measurements of laser noise alongside the measurement in the main detection channel allow us to separate measured sensing noise from the inherent birefringence noise of the apparatus. To this end we model different sources of sensing noise for cavity-enhanced polarimetry experiments, such as BMV. Our goal is to determine the main sources of noise, clarifying the limiting factors of such an apparatus. We find our noise models are compatible with the measured sensitivity of BMV. In this context we compare the phase sensitivity of separate-arm interferometers to that of a polarimetry apparatus for the discussion of current and future VMB measurements.
△ Less
Submitted 4 December, 2017;
originally announced December 2017.
-
Optical spectroscopy of a microsized Rb vapour sample in magnetic fields up to 58 tesla
Authors:
D. Ciampini,
R. Battesti,
C. Rizzo,
E. Arimondo
Abstract:
We use a magnetometer probe based on the Zeeman shift of the rubidium resonant optical transition to explore the atomic magnetic response for a wide range of field values. We record optical spectra for fields from few tesla up to 60 tesla, the limit of the coil producing the magnetic field. The atomic absorption is detected by the fluorescence emissions from a very small region with a submillimite…
▽ More
We use a magnetometer probe based on the Zeeman shift of the rubidium resonant optical transition to explore the atomic magnetic response for a wide range of field values. We record optical spectra for fields from few tesla up to 60 tesla, the limit of the coil producing the magnetic field. The atomic absorption is detected by the fluorescence emissions from a very small region with a submillimiter size. We investigate a wide range of magnetic interactions from the hyperfine Paschen-Back regime to the fine one, and the transitions between them. The magnetic field measurement is based on the rubidium absorption itself. The rubidium spectroscopic constants were previously measured with high precision, except the excited state Landé $g$-factor that we derive from the position of the absorption lines in the transition to the fine Paschen-Back regime. Our spectroscopic investigation, even if limited by the Doppler broadening of the absorption lines, measures the field with a 20 ppm uncertainty at the explored high magnetic fields. Its accuracy is limited to 75 ppm by the excited state Landé $g$-factor determination.
△ Less
Submitted 1 August, 2017;
originally announced August 2017.
-
Pulsed high magnetic field measurement via a Rubidium vapor sensor
Authors:
Sylvie George,
Nicolas Bruyant,
Jérôme Béard,
Stefano Scotto,
Ennio Arimondo,
Remy Battesti,
Donatella Ciampini,
Carlo Rizzo
Abstract:
We present a new technique to measure pulsed magnetic fields based on the use of Rubidium in gas phase as a metrological standard. We have therefore developed an instrument based on laser inducing transitions at about 780~nm (D2 line) in a Rubidium gas contained in a mini-cell of 3~mm~x~3~mm cross section. To be able to insert such a cell in a standard high field pulsed magnet we have realized a f…
▽ More
We present a new technique to measure pulsed magnetic fields based on the use of Rubidium in gas phase as a metrological standard. We have therefore developed an instrument based on laser inducing transitions at about 780~nm (D2 line) in a Rubidium gas contained in a mini-cell of 3~mm~x~3~mm cross section. To be able to insert such a cell in a standard high field pulsed magnet we have realized a fibred probe kept at a fixed temperature. Transition frequencies for both the $π$ (light polarization parallel to the magnetic field) and $σ$ (light polarization perpendicular to the magnetic field) configurations are measured by a commercial wavemeter. One innovation of our sensor is that in addition of monitoring the light transmitted by the Rb cell, which is usual, we also monitor the fluorescence emission of the gas sample from a very small volume with the advantage of reducing the impact of the field inhomogeneity on the field measurement. Our sensor has been tested up to about 58~T.
△ Less
Submitted 31 March, 2017;
originally announced April 2017.
-
Limits on Non-Linear Electrodynamics
Authors:
M Fouché,
R Battesti,
C Rizzo
Abstract:
In this paper we set a framework in which experiments whose goal is to test QED predictions can be used in a more general way to test non-linear electrodynamics (NLED) which contains low-energy QED as a special case. We review some of these experiments and we establish limits on the different free parameters by generalizing QED predictions in the framework of NLED. We finally discuss the implicati…
▽ More
In this paper we set a framework in which experiments whose goal is to test QED predictions can be used in a more general way to test non-linear electrodynamics (NLED) which contains low-energy QED as a special case. We review some of these experiments and we establish limits on the different free parameters by generalizing QED predictions in the framework of NLED. We finally discuss the implications of these limits on bound systems and isolated charged particles for which QED has been widely and successfully tested.
△ Less
Submitted 13 May, 2016;
originally announced May 2016.
-
Circular and linear magnetic birefringences in xenon at $λ= 1064$ nm
Authors:
Agathe Cadène,
Mathilde Fouché,
Alice Rivère,
Remy Battesti,
Sonia Coriani,
Antonio Rizzo,
Carlo Rizzo
Abstract:
The circular and linear magnetic birefringences corresponding to the Faraday and the Cotton-Mouton effects, respectively, have been measured in xenon at $λ= 1064$ nm. The experimental setup is based on time dependent magnetic fields and a high finesse Fabry-Perot cavity. Our value of the Faraday effect is the first measurement at this wavelength. It is compared to theoretical predictions. Our unce…
▽ More
The circular and linear magnetic birefringences corresponding to the Faraday and the Cotton-Mouton effects, respectively, have been measured in xenon at $λ= 1064$ nm. The experimental setup is based on time dependent magnetic fields and a high finesse Fabry-Perot cavity. Our value of the Faraday effect is the first measurement at this wavelength. It is compared to theoretical predictions. Our uncertainty of a few percent yields an agreement at better than 1$σ$ with the computational estimate when relativistic effects are taken into account. Concerning the Cotton-Mouton effect, our measurement, the second ever published at $λ= 1064$ nm, agrees at better than $1σ$ with theoretical predictions. We also compare our error budget with those established for other experimental published values.
△ Less
Submitted 5 March, 2015;
originally announced March 2015.
-
Faraday and Cotton-Mouton Effects of Helium at $λ= 1064$ nm
Authors:
Agathe Cadène,
Delphine Sordes,
Paul Berceau,
Mathilde Fouché,
Remy Battesti,
Carlo Rizzo
Abstract:
We present measurements of the Faraday and the Cotton-Mouton effects of helium gas at $λ=~1064$\,nm. Our apparatus is based on an up-to-date resonant optical cavity coupled to longitudinal and transverse magnetic fields. This cavity increases the signal to be measured by more than a factor of 270\,000 compared to the one acquired after a single path of light in the magnetic field region. We have r…
▽ More
We present measurements of the Faraday and the Cotton-Mouton effects of helium gas at $λ=~1064$\,nm. Our apparatus is based on an up-to-date resonant optical cavity coupled to longitudinal and transverse magnetic fields. This cavity increases the signal to be measured by more than a factor of 270\,000 compared to the one acquired after a single path of light in the magnetic field region. We have reached a precision of a few percent both for Faraday effect and Cotton-Mouton effect. Our measurements give for the first time the experimental value of the Faraday effect at $λ$=\,1064\,nm. This value is compatible with the theoretical prediction. Concerning Cotton-Mouton effect, our measurement is the second reported experimental value at this wavelength, and the first to agree at better than 1$σ$ with theoretical predictions.
△ Less
Submitted 24 July, 2013;
originally announced July 2013.
-
Vacuum magnetic linear birefringence using pulsed fields: the BMV experiment
Authors:
A. Cadène,
P. Berceau,
M. Fouché,
R. Battesti,
C. Rizzo
Abstract:
We present the current status of the BMV experiment. Our apparatus is based on an up-to-date resonant optical cavity coupled to a transverse magnetic field. We detail our data acquisition and analysis procedure which takes into account the symmetry properties of the raw data with respect to the orientation of the magnetic field and the sign of the cavity birefringence. The measurement result of th…
▽ More
We present the current status of the BMV experiment. Our apparatus is based on an up-to-date resonant optical cavity coupled to a transverse magnetic field. We detail our data acquisition and analysis procedure which takes into account the symmetry properties of the raw data with respect to the orientation of the magnetic field and the sign of the cavity birefringence. The measurement result of the vacuum magnetic linear birefringence k_\mathrm{CM}$ presented in this paper was obtained with about 200 magnetic pulses and a maximum field of 6.5\,T, giving a noise floor of about $8 \times 10^{-21}$\,T$^{-2}$ at $3σ$ confidence level.
△ Less
Submitted 22 November, 2013; v1 submitted 21 February, 2013;
originally announced February 2013.
-
Magnetic and electric properties of quantum vacuum
Authors:
Rémy Battesti,
Carlo Rizzo
Abstract:
In this report we show that vacuum is a nonlinear optical medium and we discuss what are the optical phenomena that should exist in the framework of the standard model of particle physics. We pay special attention to the low energy limit. The predicted effects for photons of energy smaller than the electron rest mass are of such a level that none has been observed experimentally yet. Progresses in…
▽ More
In this report we show that vacuum is a nonlinear optical medium and we discuss what are the optical phenomena that should exist in the framework of the standard model of particle physics. We pay special attention to the low energy limit. The predicted effects for photons of energy smaller than the electron rest mass are of such a level that none has been observed experimentally yet. Progresses in field sources and related techniques seem to indicate that in few years vacuum nonlinear optics will be accessible to human investigation.
△ Less
Submitted 5 November, 2012;
originally announced November 2012.
-
Magnetic Linear Birefringence Measurements Using Pulsed Fields
Authors:
Paul Berceau,
Mathilde Fouché,
Remy Battesti,
Carlo Rizzo
Abstract:
In this paper we present the realization of further steps towards the measurement of the magnetic birefringence of the vacuum using pulsed fields. After describing our experiment, we report the calibration of our apparatus using nitrogen gas and we discuss the precision of our measurement giving a detailed error budget. Our best present vacuum upper limit is Dn < 5.0x10^(-20) T^-2 per 4 ms acquisi…
▽ More
In this paper we present the realization of further steps towards the measurement of the magnetic birefringence of the vacuum using pulsed fields. After describing our experiment, we report the calibration of our apparatus using nitrogen gas and we discuss the precision of our measurement giving a detailed error budget. Our best present vacuum upper limit is Dn < 5.0x10^(-20) T^-2 per 4 ms acquisition time. We finally discuss the improvements necessary to reach our final goal.
△ Less
Submitted 28 November, 2011; v1 submitted 22 September, 2011;
originally announced September 2011.
-
Observation of the Inverse Cotton-Mouton Effect
Authors:
Andrei Ben-Amar Baranga,
Remy Battesti,
Mathilde Fouché,
Carlo Rizzo,
G. L. J. A. Rikken
Abstract:
We report the observation of the Inverse Cotton-Mouton Effect (ICME) i.e. a magnetization induced in a medium by non resonant linearly polarized light propagating in the presence of a transverse magnetic field. We present a detailed study of the ICME in a TGG crystal showing the dependence of the measured effect on the light intensity, the optical polarization, and on the external magnetic field.…
▽ More
We report the observation of the Inverse Cotton-Mouton Effect (ICME) i.e. a magnetization induced in a medium by non resonant linearly polarized light propagating in the presence of a transverse magnetic field. We present a detailed study of the ICME in a TGG crystal showing the dependence of the measured effect on the light intensity, the optical polarization, and on the external magnetic field. We derive a relation between the Cotton-Mouton and Inverse Cotton-Mouton effects that is roughly in agreement with existing experimental data. Our results open the way to applications of the ICME in optical devices.
△ Less
Submitted 11 March, 2011; v1 submitted 16 September, 2010;
originally announced September 2010.
-
A Photon Regeneration Experiment for Axionlike Particle Search using X-rays
Authors:
Remy Battesti,
Mathilde Fouché,
C. Detlefs,
T. Roth,
Paul Berceau,
F. Duc,
P. Frings,
G. L. J. A. Rikken,
Carlo Rizzo
Abstract:
In this letter we describe our novel photon regeneration experiment for the axionlike particle search using a x-ray beam with a photon energy of 50.2 keV and 90.7 keV, two superconducting magnets of 3 T, and a Ge detector with a high quantum efficiency. A counting rate of regenerated photons compatible with zero has been measured. The corresponding limits on the pseudoscalar axionlike particle-two…
▽ More
In this letter we describe our novel photon regeneration experiment for the axionlike particle search using a x-ray beam with a photon energy of 50.2 keV and 90.7 keV, two superconducting magnets of 3 T, and a Ge detector with a high quantum efficiency. A counting rate of regenerated photons compatible with zero has been measured. The corresponding limits on the pseudoscalar axionlike particle-two photon coupling constant is obtained as a function of the particle mass. Our setup widens the energy window of purely terrestrial experiments devoted to the axionlike particle search by coupling to two photons. It also opens a new domain of experimental investigation of photon propagation in magnetic fields.
△ Less
Submitted 3 December, 2010; v1 submitted 16 August, 2010;
originally announced August 2010.
-
Inverse Cotton-Mouton effect of the Vacuum and of atomic systems
Authors:
C. Rizzo,
A. Dupays,
R. Battesti,
M. Fouché,
G. L. J. A. Rikken
Abstract:
In this letter we calculate the Inverse Cotton-Mouton Effect (ICME) for the vacuum following the predictions of Quantum ElectroDynamics. We compare the value of this effect for the vacuum with the one expected for atomic systems. We finally show that ICME could be measured for the first time for noble gases using state-of-the-art laser systems and for the quantum vacuum with near-future laser faci…
▽ More
In this letter we calculate the Inverse Cotton-Mouton Effect (ICME) for the vacuum following the predictions of Quantum ElectroDynamics. We compare the value of this effect for the vacuum with the one expected for atomic systems. We finally show that ICME could be measured for the first time for noble gases using state-of-the-art laser systems and for the quantum vacuum with near-future laser facilities like ELI and HiPER, providing in particular a test of the nonlinear behaviour of quantum vacuum at intensities below the Schwinger limit of 4.5x10^33 W/m^2.
△ Less
Submitted 4 May, 2010;
originally announced May 2010.
-
Dynamical behaviour of birefringent Fabry-Perot cavities
Authors:
Paul Berceau,
Mathilde Fouché,
Remy Battesti,
Franck Bielsa,
Julien Mauchain,
Carlo Rizzo
Abstract:
In this paper we present a theoretical and experimental study of the dynamical behaviour of birefringent cavities. Our experimental data show that usual hypothesis which provides that a Fabry-Perot cavity is a first-order low pass filter cannot explain the behaviour of a birefringent cavity. We explain this phenomenon, and give the theoretical expression of the equivalent cavity filter which corre…
▽ More
In this paper we present a theoretical and experimental study of the dynamical behaviour of birefringent cavities. Our experimental data show that usual hypothesis which provides that a Fabry-Perot cavity is a first-order low pass filter cannot explain the behaviour of a birefringent cavity. We explain this phenomenon, and give the theoretical expression of the equivalent cavity filter which corresponds to a second-order low pass filter.
△ Less
Submitted 26 March, 2010;
originally announced March 2010.
-
Status of the BMV experiment
Authors:
Franck Bielsa,
Remy Battesti,
Mathilde Fouché,
Paul Berceau,
Cécile Robilliard,
G. Bailly,
S. Batut,
Julien Mauchain,
Marc Nardone,
O. Portugall,
Carlo Rizzo
Abstract:
In this contribution we present the status of the BMV experiment whose goal is to measure the vacuum magnetic birefringence.
In this contribution we present the status of the BMV experiment whose goal is to measure the vacuum magnetic birefringence.
△ Less
Submitted 22 February, 2010; v1 submitted 24 November, 2009;
originally announced November 2009.
-
Birefringence of interferential mirrors at normal incidence Experimental and computational study
Authors:
Franck Bielsa,
Arnaud Dupays,
Mathilde Fouché,
Remy Battesti,
Cécile Robilliard,
Carlo Rizzo
Abstract:
In this paper we present a review of the existing data on interferential mirror birefringence. We also report new measurements of two sets of mirrors that confirm that mirror phase retardation per reflection decreases when mirror reflectivity increases. We finally developed a computational code to calculate the expected phase retardation per reflection as a function of the total number of layers…
▽ More
In this paper we present a review of the existing data on interferential mirror birefringence. We also report new measurements of two sets of mirrors that confirm that mirror phase retardation per reflection decreases when mirror reflectivity increases. We finally developed a computational code to calculate the expected phase retardation per reflection as a function of the total number of layers constituting the mirror. Different cases have been studied and we have compared computational results with the trend of the experimental data. Our study indicates that the origin of the mirror intrinsic birefringence can be ascribed to the reflecting layers close to the substrate.
△ Less
Submitted 23 July, 2009;
originally announced July 2009.
-
The BMV project: Search for photon oscillations into massive particles
Authors:
C. Robilliard,
B. Pinto Da Souza,
F. Bielsa,
J. Mauchain,
M. Nardone,
G. Bailly,
M. Fouché,
R. Battesti,
C. Rizzo
Abstract:
In this contribution to PSAS08 we report on the research activities developed in our Toulouse group, in the framework of the BMV project, concerning the search for photon oscillations into massive particles, such as axion-like particles in the presence of a strong transverse magnetic field. We recall our main result obtained in collaboration with LULI at École Polytechnique (Palaiseau, France).…
▽ More
In this contribution to PSAS08 we report on the research activities developed in our Toulouse group, in the framework of the BMV project, concerning the search for photon oscillations into massive particles, such as axion-like particles in the presence of a strong transverse magnetic field. We recall our main result obtained in collaboration with LULI at École Polytechnique (Palaiseau, France). We also present the very preliminary results obtained with the BMV experiment which is set up at LNCMP (Toulouse, France).
△ Less
Submitted 4 December, 2008;
originally announced December 2008.
-
Search for photon oscillations into massive particles
Authors:
Mathilde Fouché,
Cécile Robilliard,
Stéphane Faure,
Carlo Rizzo,
Julien Mauchain,
Marc Nardone,
Remy Battesti,
Luc Martin,
Anne-Marie Sautivet,
Jean-Luc Paillard,
François Amiranoff
Abstract:
In this paper, we present the final results of our experiment on photon-axion oscillations in the presence of a magnetic field, which took place at LULI (Laboratoire pour l'Utilisation des Lasers Intenses, Palaiseau, France). Our null measurement allowed us to exclude the existence of axions with inverse coupling constant $M>9.\times 10^5$ GeV for low axion masses and to improve the preceding BF…
▽ More
In this paper, we present the final results of our experiment on photon-axion oscillations in the presence of a magnetic field, which took place at LULI (Laboratoire pour l'Utilisation des Lasers Intenses, Palaiseau, France). Our null measurement allowed us to exclude the existence of axions with inverse coupling constant $M>9.\times 10^5$ GeV for low axion masses and to improve the preceding BFRT limits by a factor 3 or more for axion masses $1.1 {meV} <m_a<2.6 {meV}$. We also show that our experimental results improve the existing limits on the parameters of a low mass hidden-sector boson usually dubbed "paraphoton" because of its similarity with the usual photon.
△ Less
Submitted 20 August, 2008;
originally announced August 2008.
-
The BMV experiment : a novel apparatus to study the propagation of light in a transverse magnetic field
Authors:
Remy Battesti,
Benoit Pinto Da Souza,
Sebastien Batut,
Cecile Robilliard,
Gilles Bailly,
Christophe Michel,
Marc Nardone,
Laurent Pinard,
Oliver Portugall,
Gerard Trenec,
Jean-Marie Mackowski,
Geert L. J. A. Rikken,
Jacques Vigue,
Carlo Rizzo
Abstract:
In this paper, we describe in detail the BMV (Biréfringence Magnétique du Vide) experiment, a novel apparatus to study the propagation of light in a transverse magnetic field. It is based on a very high finesse Fabry-Perot cavity and on pulsed magnets specially designed for this purpose. We justify our technical choices and we present the current status and perspectives.
In this paper, we describe in detail the BMV (Biréfringence Magnétique du Vide) experiment, a novel apparatus to study the propagation of light in a transverse magnetic field. It is based on a very high finesse Fabry-Perot cavity and on pulsed magnets specially designed for this purpose. We justify our technical choices and we present the current status and perspectives.
△ Less
Submitted 9 October, 2007;
originally announced October 2007.
-
No light shining through a wall : new results from a photoregeneration experiment
Authors:
Cecile Robilliard,
Remy Battesti,
Mathilde Fouche,
Julien Mauchain,
Anne-Marie Sautivet,
Francois Amiranoff,
Carlo Rizzo
Abstract:
Recently, axion-like particle search has received renewed interest. In particular, several groups have started ``light shining through a wall'' experiments based on magnetic field and laser both continuous, which is very demanding in terms of detector background. We present here the 2$σ$ limits obtained so far with our novel set-up consisting of a pulsed magnetic field and a pulsed laser. In par…
▽ More
Recently, axion-like particle search has received renewed interest. In particular, several groups have started ``light shining through a wall'' experiments based on magnetic field and laser both continuous, which is very demanding in terms of detector background. We present here the 2$σ$ limits obtained so far with our novel set-up consisting of a pulsed magnetic field and a pulsed laser. In particular, we have found that the axion-like particle two photons inverse coupling constant $M$ is $> 8\times 10^5$ GeV provided that the particle mass $m_\mathrm{a} \sim$ 1 meV. Our results definitively invalidate the axion interpretation of the original PVLAS optical measurements with a confidence level greater than 99.9%.
△ Less
Submitted 22 October, 2007; v1 submitted 9 July, 2007;
originally announced July 2007.
-
Axion Searches in the Past, at Present, and in the Near Future
Authors:
R. Battesti,
B. Beltran,
H. Davoudiasl,
M. Kuster,
P. Pugnat,
R. Rabadan,
A. Ringwald,
N. Spooner,
K. Zioutas
Abstract:
Theoretical axion models state that axions are very weakly interacting particles. In order to experimentally detect them, the use of colorful and inspired techniques becomes mandatory. There is a wide variety of experimental approaches that were developed during the last 30 years, most of them make use of the Primakoff effect, by which axions convert into photons in the presence of an electromag…
▽ More
Theoretical axion models state that axions are very weakly interacting particles. In order to experimentally detect them, the use of colorful and inspired techniques becomes mandatory. There is a wide variety of experimental approaches that were developed during the last 30 years, most of them make use of the Primakoff effect, by which axions convert into photons in the presence of an electromagnetic field. We review the experimental techniques used to search for axions and will give an outlook on experiments planned for the near future.
△ Less
Submitted 4 May, 2007;
originally announced May 2007.
-
Comment to Manipulating the polarization of laser beams by an external magnetic field, arXiv:physics/0603175v1
Authors:
R. Battesti,
B. Pinto Da Souza,
C. Rizzo,
C. Robilliard,
J. Vigue
Abstract:
The basic assumption of the authors of manuscript arXiv:physics/0603175v1 (21 Mar 2006) is that a laser wave differs from a plane wave because of photon coherence. This is not true and therefore their conclusion is also wrong.
The basic assumption of the authors of manuscript arXiv:physics/0603175v1 (21 Mar 2006) is that a laser wave differs from a plane wave because of photon coherence. This is not true and therefore their conclusion is also wrong.
△ Less
Submitted 24 March, 2006;
originally announced March 2006.
-
Bloch oscillations of ultracold atoms: a tool for a metrological determination of $h/m_{Rb}$
Authors:
Remy Battesti,
Pierre Clade,
Saida Guellati-Khelifa,
Catherine Schwob,
Benoit Gremaud,
Francois Nez,
Lucile Julien,
Francois Biraben
Abstract:
We use Bloch oscillations in a horizontal moving standing wave to transfer a large number of photon recoils to atoms with a high efficiency (99.5% per cycle). By measuring the photon recoil of $^{87}Rb$, using velocity selective Raman transitions to select a subrecoil velocity class and to measure the final accelerated velocity class, we have determined $h/m_{Rb}$ with a relative precision of 0.…
▽ More
We use Bloch oscillations in a horizontal moving standing wave to transfer a large number of photon recoils to atoms with a high efficiency (99.5% per cycle). By measuring the photon recoil of $^{87}Rb$, using velocity selective Raman transitions to select a subrecoil velocity class and to measure the final accelerated velocity class, we have determined $h/m_{Rb}$ with a relative precision of 0.4 ppm. To exploit the high momentum transfer efficiency of our method, we are develo** a vertical standing wave set-up. This will allow us to measure $h/m_{Rb}$ better than $10^{-8}$ and hence the fine structure constant $α$ with an uncertainty close to the most accurate value coming from the ($g-2$) determination.
△ Less
Submitted 3 May, 2004;
originally announced May 2004.