Partial Discharges detection in 1 MV power supplies in MITICA experiment, the ITER Heating Neutral Beam Injector prototype
Authors:
Marco Boldrin,
Mattia Dan,
Vanni Toigo,
Loris Zanotto,
Paolo Barbato,
Lucio Baseggio,
Manola Carraro,
Raffaele Ghiraldelli,
Enrico Zerbetto,
Stefano Malgarotti,
Alberto Rizzi,
Giuseppe Rizzi,
Hans Decamps,
Hiroyuki Tobari
Abstract:
MITICA (Megavolt ITER Injector & Concept Advancement), the full scale prototype of ITER Heating Neutral Beam, is under realization at the Neutral Beam Test Facility (Padova, Italy). It is designed to deliver 16.5 MW to ITER plasma, obtained by accelerating negative Deuterium ions up to 1 MeV for a total ion current of 40 A and then neutralized. MITICA Acceleration Power Supply is composed of sever…
▽ More
MITICA (Megavolt ITER Injector & Concept Advancement), the full scale prototype of ITER Heating Neutral Beam, is under realization at the Neutral Beam Test Facility (Padova, Italy). It is designed to deliver 16.5 MW to ITER plasma, obtained by accelerating negative Deuterium ions up to 1 MeV for a total ion current of 40 A and then neutralized. MITICA Acceleration Power Supply is composed of several non-standard equipment, beyond industrial standard for insulation voltage level (-1 MVdc) and dimensions. Voltage withstand tests (up to 1.265 MVdc) have been performed in five subsequent steps (from 2018 to 2019), according to the installation progress, after connecting equipment belonging to different procurements. During integrated commissioning, started in 2021, two breakdowns occurred in a position of the HV plant not still identified, so they could be occurred either in air or in SF6. To identify the locations of possible weak insulation points, the existing diagnostics for partial discharge detection (the precursor of breakdowns) as a first step have been improved on air-insulated parts by consisting in a set of instrumentation, like capacitive probes and off-the-shelf instruments for AC application (acoustic and electromagnetic sensors). The paper deals with the instruments qualification to assess their suitability for DC usage and then with the investigation performed in MITICA, in particular: 1) sensitivity assessment campaign, with artificially produced corona effect to identify the minimum threshold of each diagnostics 2) voltage application to MITICA plant, moving the instrumentation around equipment and increasing progressively the voltage looking for corona phenomena to identify possible weak insulation points.
△ Less
Submitted 5 April, 2023;
originally announced April 2023.
-
Overview on electrical issues faced during the SPIDER experimental campaigns
Authors:
Alberto Maistrello,
Matteo Agostini,
Marco Bigi,
Matteo Brombin,
Mattia Dan,
Riccardo Casagrande,
Marco De Nardi,
Alberto Ferro,
Elena Gaio,
Palak Jain,
Francesco Lunardon,
Nicolò Marconato,
Diego Marcuzzi,
Mauro Recchia,
Tommaso Patton,
Mauro Pavei,
Francesco Santoro,
Vanni Toigo,
Loris Zanotto,
Marco Barbisan,
Lucio Baseggio,
Marco Bernardi,
Giovanni Berton,
Marco Boldrin,
Samuele Dal Bello
, et al. (17 additional authors not shown)
Abstract:
SPIDER is the full-scale prototype of the ion source of the ITER Heating Neutral Beam Injector, where negative ions of Hydrogen or Deuterium are produced by a RF generated plasma and accelerated with a set of grids up to ~100 keV. The Power Supply System is composed of high voltage dc power supplies capable of handling frequent grid breakdowns, high current dc generators for the magnetic filter fi…
▽ More
SPIDER is the full-scale prototype of the ion source of the ITER Heating Neutral Beam Injector, where negative ions of Hydrogen or Deuterium are produced by a RF generated plasma and accelerated with a set of grids up to ~100 keV. The Power Supply System is composed of high voltage dc power supplies capable of handling frequent grid breakdowns, high current dc generators for the magnetic filter field and RF generators for the plasma generation. During the first 3 years of SPIDER operation different electrical issues were discovered, understood and addressed thanks to deep analyses of the experimental results supported by modelling activities. The paper gives an overview on the observed phenomena and relevant analyses to understand them, on the effectiveness of the short-term modifications provided to SPIDER to face the encountered issues and on the design principle of long-term solutions to be introduced during the currently ongoing long shutdown.
△ Less
Submitted 5 April, 2023;
originally announced April 2023.
-
Continuous pulse advances in the negative ion source NIO1
Authors:
M. Barbisan,
R. Agnello,
M. Cavenago,
R. S. Delogu,
A. Pimazzoni,
L. Balconi,
P. Barbato,
L. Baseggio,
A. Castagni,
B. Pouradier Duteil,
L. Franchin,
B. Laterza,
F. Molon,
M. Maniero,
L. Migliorato,
R. Milazzo,
G. Passalacqua,
C. Poggi,
D. Ravarotto,
R. Rizzieri,
L. Romanato,
F. Rossetto,
L Trevisan,
M. Ugoletti,
B. Zaniol
, et al. (1 additional authors not shown)
Abstract:
Consorzio RFX and INFN-LNL have designed, built and operated the compact radiofrequency negative ion source NIO1 (Negative Ion Optimization phase 1) with the aim of studying the production and acceleration of H- ions. In particular, NIO1 was designed to keep plasma generation and beam extraction continuously active for several hours. Since 2020 the production of negative ions at the plasma grid (t…
▽ More
Consorzio RFX and INFN-LNL have designed, built and operated the compact radiofrequency negative ion source NIO1 (Negative Ion Optimization phase 1) with the aim of studying the production and acceleration of H- ions. In particular, NIO1 was designed to keep plasma generation and beam extraction continuously active for several hours. Since 2020 the production of negative ions at the plasma grid (the first grid of the acceleration system) has been enhanced by a Cs layer, deposited though active Cs evaporation in the source volume. For the negative ion sources applied to fusion neutral beam injectors, it is essential to keep the beam current and the fraction of co-extracted electrons stable for at least 1 h, against the consequences of Cs sputtering and redistribution operated by the plasma. The paper presents the latest results of the NIO1 source, in terms of caesiation process and beam performances during continuous (6÷7 h) plasma pulses. Due to the small dimensions of the NIO1 source (20 x (diam.)10 cm), the Cs density in the volume is high (10^15 ÷10^16 m^-3) and dominated by plasma-wall interaction. The maximum beam current density and minimum fraction of co-extracted electrons were respectively about 30 A/m^2 and 2. Similarly to what done in other negative ion sources, the plasma grid temperature in NIO1 was raised for the first time, up to 80 °C, although this led to a minimal improvement of the beam current and to an increase of the co-extracted electron current.
△ Less
Submitted 24 August, 2023; v1 submitted 12 December, 2022;
originally announced December 2022.