-
Characterization of superconducting NbTiN films using a Dispersive Fourier Transform Spectrometer
Authors:
B. N. R. Lap,
A. Khudchenko,
R. Hesper,
K. I. Rudakov,
P. Dmitriev,
F. Khan,
V. Koshelets,
A. M. Baryshev
Abstract:
We have built a Terahertz Dispersive Fourier Transform Spectrometer \cite{Birch1987} to study frequency properties of superconducting films used for fabrication of THz detectors. The signal reflected from the tested film is measured in time domain, which allows to separate it from the other reflections. The complex conductivity of the film depends on frequency and determines the reflection coeffic…
▽ More
We have built a Terahertz Dispersive Fourier Transform Spectrometer \cite{Birch1987} to study frequency properties of superconducting films used for fabrication of THz detectors. The signal reflected from the tested film is measured in time domain, which allows to separate it from the other reflections. The complex conductivity of the film depends on frequency and determines the reflection coefficient. By comparing the film reflection in the superconducting state (temperature is below $T_c$) with the reflection of the normal state, we characterise the film quality at terahertz frequencies. The method was applied to 70 and 200nm thick Nb films on a silicon wafer and to 360nm thick NbTiN films on silicon and quartz wafers. The strong-coupling coefficient, $α$, was found to be 3.52 for Nb, and 3.71-4.02 for the NbTiN films. The experimental results were fitted using extended Mattis-Bardeen theory \cite{Noguchi2012} and show a good agreement.
△ Less
Submitted 4 October, 2021;
originally announced October 2021.
-
High Resolution Imaging of a Black Hole Shadow with Millimetron Orbit around Lagrange Point L2
Authors:
S. F. Likhachev,
A. G. Rudnitskiy,
M. A. Shchurov,
A. S. Andrianov,
A. M. Baryshev,
S. V. Chernov,
V. I. Kostenko
Abstract:
Imaging of the shadow around supermassive black hole (SMBH) horizon with a very long baseline interferometry (VLBI) is recognized recently as a powerful tool for experimental testing of Einstein's General relativity. The Event Horizon Telescope (EHT) has demonstrated that an Earth-extended VLBI with the maximum long base ($D=10,700$ km) can provide a sufficient angular resolution $θ\sim 20~μ$as at…
▽ More
Imaging of the shadow around supermassive black hole (SMBH) horizon with a very long baseline interferometry (VLBI) is recognized recently as a powerful tool for experimental testing of Einstein's General relativity. The Event Horizon Telescope (EHT) has demonstrated that an Earth-extended VLBI with the maximum long base ($D=10,700$ km) can provide a sufficient angular resolution $θ\sim 20~μ$as at $λ=1.3$ mm ($ν=230$ GHz) for imaging the shadow around SMBH located in the galaxy M87$^\ast$. However, the accuracy of critically important characteristics, such as the asymmetry of the crescent-shaped bright structure around the shadow and the sharpness of a transition zone between the shadow floor and the bright crescent silhouette, both of order $Δθ\sim 4~μ$as, is still to be improved. In our previous paper we have shown that Space-Earth VLBI observation within a joint Millimetron and EHT configuration at the near-Earth high elliptical orbit (HEO) can considerably improve the image quality. Even more solid grounds for firm experimental validation of General relativity can be obtained with a higher resolution available within the joint Millimetron and EHT program at the Lagrangian point L2 in the Sun-Earth system with an expected imaging resolution at 230~GHz of $Δθ\sim 5~μ$as. In this paper we argue that in spite of limitations of L2 orbit, an adequate sparse $(u,v)$ coverage can be achieved and the imaging of the shadows around Sgr A$^\ast$ and M87$^\ast$ can be performed with a reasonable quality.
△ Less
Submitted 2 December, 2021; v1 submitted 6 August, 2021;
originally announced August 2021.
-
APEX-SEPIA660 Early Science: Gas at densities above $10^7$ cm$^{-3}$ towards OMC-1
Authors:
A. Hacar,
M. R. Hogerheijde,
D. Harsono,
S. Portegies Zwart,
C. De Breuck,
K. Torstensson,
W. Boland,
A. M. Baryshev,
R. Hesper,
J. Barkhof,
J. Adema,
M. E. Bekema,
A. Koops,
A. Khudchenko,
R. Stark
Abstract:
Context. The star formation rates and stellar densities found in young massive clusters suggest that these stellar systems originate from gas at densities n(H$_2$) $>10^7$ cm$^{-3}$. Until today, however, the physical characterization of this ultra high density material remains largely unconstrained in observations. Aims. We investigated the density properties of the star-forming gas in the OMC-1…
▽ More
Context. The star formation rates and stellar densities found in young massive clusters suggest that these stellar systems originate from gas at densities n(H$_2$) $>10^7$ cm$^{-3}$. Until today, however, the physical characterization of this ultra high density material remains largely unconstrained in observations. Aims. We investigated the density properties of the star-forming gas in the OMC-1 region located in the vicinity of the Orion Nebula Cluster (ONC). Methods. We mapped the molecular emission at 652 GHz in OMC-1 as part of the APEX-SEPIA660 Early Science. Results. We detect bright and extended N$_2$H$^+$ (J=7-6) line emission along the entire OMC-1 region. Comparisons with previous ALMA data of the (J=1-0) transition and radiative transfer models indicate that the line intensities observed in this N$_2$H$^+$ (7-6) line are produced by large mass reservoirs of gas at densities n(H$_2$) $>10^7$ cm$^{-3}$. Conclusions. The first detection of this N$_2$H$^+$ (7-6) line at parsec-scales demonstrates the extreme density conditions of the star-forming gas in young massive clusters such as the ONC. Our results highlight the unique combination of sensitivity and map** capabilities of the new SEPIA660 receiver for the study of the ISM properties at high frequencies.
△ Less
Submitted 26 September, 2020;
originally announced September 2020.
-
Simulations of M87 and Sgr A* Imaging with the Millimetron Space Observatory on near-Earth orbits
Authors:
A. S. Andrianov,
A. M. Baryshev,
H. Falcke,
I. A. Girin,
T. de Graauw,
V. I. Kostenko,
V. Kudriashov,
V. A. Ladygin,
S. F. Likhachev,
F. Roelofs,
A. G. Rudnitskiy,
A. R. Shaykhutdinov,
Y. A. Shchekinov,
M. A. Shchurov
Abstract:
High resolution imaging of supermassive black holes shadows is a direct way to verify the theory of general relativity at extreme gravity conditions. Very Long Baseline Interferometry (VLBI) observations at millimeter/sub-millimeter wavelengths can provide such angular resolution for supermassive black holes, located in Sgr A* and M87. Recent VLBI observations of M87 with the Event Horizon Telesco…
▽ More
High resolution imaging of supermassive black holes shadows is a direct way to verify the theory of general relativity at extreme gravity conditions. Very Long Baseline Interferometry (VLBI) observations at millimeter/sub-millimeter wavelengths can provide such angular resolution for supermassive black holes, located in Sgr A* and M87. Recent VLBI observations of M87 with the Event Horizon Telescope (EHT) has shown such capabilities. The maximum obtainable spatial resolution of EHT is limited by Earth diameter and atmospheric phase variations. In order to improve the image resolution longer baselines are required. Radioastron space mission has successfully demonstrated the capabilities of Space-Earth VLBI with baselines much larger than Earth diameter. Millimetron is a next space mission of the Russian Space Agency that will operate at millimeter wavelengths. Nominal orbit of the observatory will be located around Lagrangian L2 point of the Sun-Earth system. In order to optimize the VLBI mode, we consider a possible second stage of the mission that could use near-Earth high elliptical orbit (HEO). In this contribution a set of near-Earth orbits is used for the synthetic space-ground VLBI observations of Sgr A* and M87 in joint Millimetron and EHT configuration. General-relativistic magnetohydrodynamic models (GRMHD) for black hole environment of Sgr A* and M87 are used for static and dynamic imaging simulations at 230 GHz. A comparison preformed between ground and space-ground baselines demonstrates that joint observations with Millimetron and EHT significantly improve the image resolution and allow the EHT+Millimetron to obtain snapshot images of Sgr A* probing dynamics at fast timescales.
△ Less
Submitted 2 September, 2020; v1 submitted 17 June, 2020;
originally announced June 2020.
-
Complex beam map** and Fourier optics analysis of a wide field Microwave Kinetic Inductance Detector camera
Authors:
S. J. C. Yates,
K. K. Davis,
W. Jellema,
J. J. A. Baselmans,
A. M. Baryshev
Abstract:
For astronomical instruments, accurate knowledge of the optical pointing and coupling are essential to characterize the alignment and performance of (sub-)systems prior to integration and deployment. Ideally, this requires the phase response of the optical system, which for direct (phase insensitive) detectors was not previously accessible. Here we show development of the phase sensitive complex b…
▽ More
For astronomical instruments, accurate knowledge of the optical pointing and coupling are essential to characterize the alignment and performance of (sub-)systems prior to integration and deployment. Ideally, this requires the phase response of the optical system, which for direct (phase insensitive) detectors was not previously accessible. Here we show development of the phase sensitive complex beam pattern technique using a dual optical source heterodyne technique for a large field of view Microwave Kinetic Inductance Detector camera at 350 GHz. We show here how you can analyze the measured data with Fourier optics, which allows integration into a telescope model to calculate the on sky beam pattern and telescope aperture efficiency prior to deployment at a telescope.
△ Less
Submitted 10 February, 2020;
originally announced February 2020.
-
Analysis techniques for complex-field radiation pattern measurements
Authors:
Kristina K. Davis,
Willem Jellema,
Stephen J. C. Yates,
Christopher E. Groppi,
Jochem J. A. Baselmans,
Andrey M. Baryshev
Abstract:
Complex field measurements are increasingly becoming the standard for state-of-the-art astronomical instrumentation. Complex field measurements have been used to characterize a suite of ground, airborne, and space-based heterodyne receiver missions [1], [2], [3], [4], [5], [6], and a description of how to acquire coherent field maps for direct detector arrays was demonstrated in Davis et. al. 2017…
▽ More
Complex field measurements are increasingly becoming the standard for state-of-the-art astronomical instrumentation. Complex field measurements have been used to characterize a suite of ground, airborne, and space-based heterodyne receiver missions [1], [2], [3], [4], [5], [6], and a description of how to acquire coherent field maps for direct detector arrays was demonstrated in Davis et. al. 2017. This technique has the ability to determine both amplitude and phase radiation patterns from individual pixels on an array. Phase information helps to better characterize the optical performance of the array (as compared to total power radiation patterns) by constraining the fit in an additional plane [4].
Here we discuss the mathematical framework used in an analysis pipeline developed to process complex field radiation pattern measurements. This routine determines and compensates misalignments of the instrument and scanning system. We begin with an overview of Gaussian beam formalism and how it relates to complex field pattern measurements. Next we discuss a scan strategy using an offset in z along the optical axis that allows first-order optical standing waves between the scanned source and optical system to be removed in post-processing. Also discussed is a method by which the co- and cross-polarization fields can be extracted individually for each pixel by rotating the two orthogonal measurement planes until the signal is the co-polarization map is maximized (and the signal in the cross-polarization field is minimized). We detail a minimization function that can fit measurement data to an arbitrary beam shape model. We conclude by discussing the angular plane wave spectral (APWS) method for beam propagation, including the near-field to far-field transformation.
△ Less
Submitted 21 September, 2018;
originally announced September 2018.
-
Eliminating stray radiation inside large area imaging arrays
Authors:
Stephen J. C. Yates,
Simon Doyle,
Peter Barry,
Andrey M. Baryshev,
Juan Bueno,
Lorenza Ferrari,
Nuria Llombart,
Vignesh Murugesan,
David J. Thoen,
Ozan Yurduseven,
Jochem J. A. Baselmans
Abstract:
With increasing array size, it is increasingly important to control stray radiation inside the detector chips themselves. We demonstrate this effect with focal plane arrays of absorber coupled Lumped Element microwave Kinetic Inductance Detectors (LEKIDs) and lens-antenna coupled distributed quarter wavelength Microwave Kinetic Inductance Detectors (MKIDs). In these arrays the response from a poin…
▽ More
With increasing array size, it is increasingly important to control stray radiation inside the detector chips themselves. We demonstrate this effect with focal plane arrays of absorber coupled Lumped Element microwave Kinetic Inductance Detectors (LEKIDs) and lens-antenna coupled distributed quarter wavelength Microwave Kinetic Inductance Detectors (MKIDs). In these arrays the response from a point source at the pixel position is at a similar level to the stray response integrated over the entire chip area. For the antenna coupled arrays, we show that this effect can be suppressed by incorporating an on-chip stray light absorber. A similar method should be possible with the LEKID array, especially when they are lens coupled.
△ Less
Submitted 11 September, 2018;
originally announced September 2018.
-
Digital compensation of the side-band-rejection ratio in a fully analog 2SB sub-millimeter receiver
Authors:
R. Rodriguez,
R. Finger,
F. P. Mena,
A. Alvear,
R. Fuentes,
A. Khudchenko,
R. Hesper,
A. M. Baryshev,
N. Reyes,
L. Bronfman
Abstract:
In observational radio astronomy, sideband-separating receivers are preferred, particularly under high atmospheric noise, which is usually the case in the sub-millimeter range. However, obtaining a good rejection ratio between the two sidebands is difficult since, unavoidably, imbalances in the different analog components appear. We describe a method to correct these imbalances without making any…
▽ More
In observational radio astronomy, sideband-separating receivers are preferred, particularly under high atmospheric noise, which is usually the case in the sub-millimeter range. However, obtaining a good rejection ratio between the two sidebands is difficult since, unavoidably, imbalances in the different analog components appear. We describe a method to correct these imbalances without making any change in the analog part of the sideband-separating receiver, specifically, kee** the intermediate-frequency hybrid in place. This opens the possibility of implementing the method in any existing receiver. We have built hardware to demonstrate the validity of the method and tested it on a fully analog receiver operating between 600 and 720GHz. We have tested the stability of calibration and performance vs time and after full resets of the receiver. We have performed an error analysis to compare the digital compensation in two configurations of analog receivers, with and without intermediate frequency (IF) hybrid. An average compensated sideband rejection ratio of 46dB is obtained. Degradation of the compensated sideband rejection ratio on time and after several resets of the receiver is minimal. A receiver with an IF hybrid is more robust to systematic errors. Moreover, we have shown that the intrinsic random errors in calibration have the same impact for configuration without IF hybrid and for a configuration with IF hybrid with analog rejection ratio better than 10dB. Compensated rejection ratios above 40dB are obtained even in the presence of high analog rejection. The method is robust allowing its use under normal operational conditions at any telescope. We also demonstrate that a full analog receiver is more robust against systematic errors. Finally, the error bars associated to the compensated rejection ratio are almost independent of whether IF hybrid is present or not.
△ Less
Submitted 11 June, 2018;
originally announced June 2018.
-
SEPIA - a new single pixel receiver at the APEX Telescope
Authors:
V. Belitsky,
I. Lapkin,
M. Fredrixon,
D. Meledin,
E. Sundin,
B. Billade,
S. -E. Ferm,
A. Pavolotsky,
H. Rashid,
M. Strandberg,
V. Desmaris,
A. Ermakov,
S. Krause,
M. Olberg,
P. Aghdam,
S. Shafiee,
P. Bergman,
E. De Beck,
H. Olofsson,
J. Conway,
C. De Breuck,
K. Immer,
P. Yagoubov,
F. M. Montenegro-Montes,
K. Torstensson
, et al. (9 additional authors not shown)
Abstract:
Context: We describe the new SEPIA (Swedish-ESO PI Instrument for APEX) receiver, which was designed and built by the Group for Advanced Receiver Development (GARD), at Onsala Space Observatory (OSO) in collaboration with ESO. It was installed and commissioned at the APEX telescope during 2015 with an ALMA Band 5 receiver channel and updated with a new frequency channel (ALMA Band 9) in February 2…
▽ More
Context: We describe the new SEPIA (Swedish-ESO PI Instrument for APEX) receiver, which was designed and built by the Group for Advanced Receiver Development (GARD), at Onsala Space Observatory (OSO) in collaboration with ESO. It was installed and commissioned at the APEX telescope during 2015 with an ALMA Band 5 receiver channel and updated with a new frequency channel (ALMA Band 9) in February 2016. Aims: This manuscript aims to provide, for observers who use the SEPIA receiver, a reference in terms of the hardware description, optics and performance as well as the commissioning results. Methods: Out of three available receiver cartridge positions in SEPIA, the two current frequency channels, corresponding to ALMA Band 5, the RF band 158--211 GHz, and Band 9, the RF band 600--722 GHz, provide state-of-the-art dual polarization receivers. The Band 5 frequency channel uses 2SB SIS mixers with an average SSB noise temperature around 45K with IF (intermediate frequency) band 4--8 GHz for each sideband providing total 4x4 GHz IF band. The Band 9 frequency channel uses DSB SIS mixers with a noise temperature of 75--125K with IF band 4--12 GHz for each polarization. Results: Both current SEPIA receiver channels are available to all APEX observers.
△ Less
Submitted 20 December, 2017;
originally announced December 2017.
-
Surface wave control for large arrays of microwave kinetic inductance detectors
Authors:
Stephen J. C. Yates,
Andrey M. Baryshev,
Ozan Yurduseven,
Juan Bueno,
Kristina K. Davis,
Lorenza Ferrari,
Willem Jellema,
Nuria Llombart,
Vignesh Murugesan,
David J. Thoen,
Jochem J. A. Baselmans
Abstract:
Large ultra-sensitive detector arrays are needed for present and future observatories for far infra-red, submillimeter wave (THz), and millimeter wave astronomy. With increasing array size, it is increasingly important to control stray radiation inside the detector chips themselves, the surface wave. We demonstrate this effect with focal plane arrays of 880 lens-antenna coupled Microwave Kinetic I…
▽ More
Large ultra-sensitive detector arrays are needed for present and future observatories for far infra-red, submillimeter wave (THz), and millimeter wave astronomy. With increasing array size, it is increasingly important to control stray radiation inside the detector chips themselves, the surface wave. We demonstrate this effect with focal plane arrays of 880 lens-antenna coupled Microwave Kinetic Inductance Detectors (MKIDs). Presented here are near field measurements of the MKID optical response versus the position on the array of a reimaged optical source. We demonstrate that the optical response of a detector in these arrays saturates off-pixel at the $\sim-30$ dB level compared to the peak pixel response. The result is that the power detected from a point source at the pixel position is almost identical to the stray response integrated over the chip area. With such a contribution, it would be impossible to measure extended sources, while the point source sensitivity is degraded due to an increase of the stray loading. However, we show that by incorporating an on-chip stray light absorber, the surface wave contribution is reduced by a factor $>$10. With the on-chip stray light absorber the point source response is close to simulations down to the $\sim-35$ dB level, the simulation based on an ideal Gaussian illumination of the optics. In addition, as a crosscheck we show that the extended source response of a single pixel in the array with the absorbing grid is in agreement with the integral of the point source measurements.
△ Less
Submitted 7 July, 2017;
originally announced July 2017.
-
A kilo-pixel imaging system for future space based far-infrared observatories using microwave kinetic inductance detectors
Authors:
J. J. A. Baselmans,
J. Bueno,
S. J. C. Yates,
O. Yurduseven,
N. Llombart,
K. Karatsu,
A. M. Baryshev,
L. Ferrari,
A. Endo,
D. J. Thoen,
P. J. de Visser,
R. M. J. Janssen,
V. Murugesan,
E. F. C. Driessen,
G. Coiffard,
J. Martin-Pintado,
P. Hargrave,
M. Griffin
Abstract:
Future astrophysics and cosmic microwave background space missions operating in the far-infrared to millimetre part of the spectrum will require very large arrays of ultra-sensitive detectors in combination with high multiplexing factors and efficient low-noise and low-power readout systems. We have developed a demonstrator system suitable for such applications. The system combines a 961 pixel ima…
▽ More
Future astrophysics and cosmic microwave background space missions operating in the far-infrared to millimetre part of the spectrum will require very large arrays of ultra-sensitive detectors in combination with high multiplexing factors and efficient low-noise and low-power readout systems. We have developed a demonstrator system suitable for such applications. The system combines a 961 pixel imaging array based upon Microwave Kinetic Inductance Detectors (MKIDs) with a readout system capable of reading out all pixels simultaneously with only one readout cable pair and a single cryogenic amplifier. We evaluate, in a representative environment, the system performance in terms of sensitivity, dynamic range, optical efficiency, cosmic ray rejection, pixel-pixel crosstalk and overall yield at at an observation centre frequency of 850 GHz and 20% fractional bandwidth. The overall system has an excellent sensitivity, with an average detector sensitivity NEPdet=3x10^-19 W/rt(Hz) measured using a thermal calibration source. At a loading power per pixel of 50fW we demonstrate white, photon noise limited detector noise down to 300 mHz. The dynamic range would allow the detection of 1 Jy bright sources within the field of view without tuning the readout of the detectors. The expected dead time due to cosmic ray interactions, when operated in an L2 or a similar far-Earth orbit, is found to be <4%. Additionally, the achieved pixel yield is 83% and the crosstalk between the pixels is <-30dB. This demonstrates that MKID technology can provide multiplexing ratios on the order of a 1000 with state-of-the-art single pixel performance, and that the technology is now mature enough to be considered for future space based observatories and experiments.
△ Less
Submitted 1 March, 2017; v1 submitted 7 September, 2016;
originally announced September 2016.
-
Measurements and analysis of optical crosstalk in a microwave kinetic inductance detector array
Authors:
L. Bisigello,
S. J. C. Yates,
L. Ferrari,
J. J. A. Baselmans,
A. M. Baryshev
Abstract:
The main advantage of Microwave Kinetic Inductance Detector arrays (MKID) is their multiplexing capability, which allows for building cameras with a large number of pixels and good sensitivity, particularly suitable to perform large blank galaxy surveys. However, to have as many pixels as possible it is necessary to arrange detectors close in readout frequency. Consequently KIDs overlap in frequen…
▽ More
The main advantage of Microwave Kinetic Inductance Detector arrays (MKID) is their multiplexing capability, which allows for building cameras with a large number of pixels and good sensitivity, particularly suitable to perform large blank galaxy surveys. However, to have as many pixels as possible it is necessary to arrange detectors close in readout frequency. Consequently KIDs overlap in frequency and are coupled to each other producing crosstalk. Because crosstalk can be only minimised by improving the array design, in this work we aim to correct for this effect a posteriori. We analysed a MKID array consisting of 880 KIDs with readout frequencies at 4-8 GHz. We measured the beam patterns for every detector in the array and described the response of each detector by using a two-dimensional Gaussian fit. Then, we identified detectors affected by crosstalk above -30 dB level from the maximum and removed the signal of the crosstalking detectors. Moreover, we modelled the crosstalk level for each KID as a function of the readout frequency separation starting from the assumption that the transmission of a KID is a Lorenztian function in power. We were able to describe the general crosstalk level of the array and the crosstalk of each KID within 5 dB, so enabling the design of future arrays with the crosstalk as a design criterion. In this work, we demonstrate that it is possible to process MKID images a posteriori to decrease the crosstalk effect, subtracting the response of each coupled KID from the original map.
△ Less
Submitted 1 September, 2016;
originally announced September 2016.
-
Calibration scheme for large Kinetic Inductance Detector Arrays based on Readout Frequency Response
Authors:
L. Bisigello,
S. J. C. Yates,
V. Murugesan,
J. J. A. Baselmans,
A. M. Baryshev
Abstract:
Microwave kinetic inductance detector (MKID) provides a way to build large ground based sub-mm instruments such as NIKA and A-MKID. For such instruments, therefore, it is important to understand and characterize the response to ensure good linearity and calibration over wide dynamic range. We propose to use the MKID readout frequency response to determine the MKID responsivity to an input optical…
▽ More
Microwave kinetic inductance detector (MKID) provides a way to build large ground based sub-mm instruments such as NIKA and A-MKID. For such instruments, therefore, it is important to understand and characterize the response to ensure good linearity and calibration over wide dynamic range. We propose to use the MKID readout frequency response to determine the MKID responsivity to an input optical source power. A signal can be measured in a KID as a change in the phase of the readout signal with respect to the KID resonant circle. Fundamentally, this phase change is due to a shift in the KID resonance frequency, in turn due to a radiation induced change in the quasiparticle number in the superconducting resonator. We show that shift in resonant frequency can be determined from the phase shift by using KID phase versus frequency dependence using a previously measured resonant frequency. Working in this calculated resonant frequency, we gain near linearity and constant calibration to a constant optical signal applied in a wide range of operating points on the resonance and readout powers. This calibration method has three particular advantages: first, it is fast enough to be used to calibrate large arrays, with pixel counts in the thousand of pixels; second, it is based on data that are already necessary to determine KID positions; third, it can be done without applying any optical source in front of the array.
△ Less
Submitted 1 February, 2016;
originally announced February 2016.
-
The non-equilibrium response of a superconductor to pair-breaking radiation measured over a broad frequency band
Authors:
P. J. de Visser,
S. J. C. Yates,
T. Guruswamy,
D. J. Goldie,
S. Withington,
A. Neto,
N. Llombart,
A. M. Baryshev,
T. M. Klapwijk,
J. J. A. Baselmans
Abstract:
We have measured the absorption of terahertz radiation in a BCS superconductor over a broad range of frequencies from 200 GHz to 1.1 THz, using a broadband antenna-lens system and a tantalum microwave resonator. From low frequencies, the response of the resonator rises rapidly to a maximum at the gap edge of the superconductor. From there on the response drops to half the maximum response at twice…
▽ More
We have measured the absorption of terahertz radiation in a BCS superconductor over a broad range of frequencies from 200 GHz to 1.1 THz, using a broadband antenna-lens system and a tantalum microwave resonator. From low frequencies, the response of the resonator rises rapidly to a maximum at the gap edge of the superconductor. From there on the response drops to half the maximum response at twice the pair-breaking energy. At higher frequencies, the response rises again due to trap** of pair-breaking phonons in the superconductor. In practice this is the first measurement of the frequency dependence of the quasiparticle creation efficiency due to pair-breaking in a superconductor. The efficiency, calculated from the different non-equilibrium quasiparticle distribution functions at each frequency, is in agreement with the measurements.
△ Less
Submitted 22 May, 2015;
originally announced May 2015.
-
The ALMA Band 9 receiver - Design, construction, characterization, and first light
Authors:
A. M. Baryshev,
R. Hesper,
F. P. Mena,
T. M. Klapwijk,
T. A. van Kempen,
M. R. Hogerheijde,
B. D. Jackson,
J. Adema,
G. J. Gerlofsma,
M. E. Bekema,
J. Barkhof,
L. H. R. de Haan-Stijkel,
M. van den Bemt,
A. Koops,
K. Keizer,
C. Pieters,
J. Koops van het Jagt,
H. H. A. Schaeffer,
T. Zijlstra,
M. Kroug,
C. F. J. Lodewijk,
K. Wielinga,
W. Boland,
M. W. M. de Graauw,
E. F. van Dishoeck
, et al. (2 additional authors not shown)
Abstract:
We describe the design, construction, and characterization of the Band 9 heterodyne receivers (600-720 GHz) for the Atacama Large Millimeter / submillimeter Array (ALMA). The ALMA Band 9 receiver units ("cartridges"), which are installed in the telescope's front end, have been designed to detect and down-convert two orthogonal linear polarization components of the light collected by the ALMA anten…
▽ More
We describe the design, construction, and characterization of the Band 9 heterodyne receivers (600-720 GHz) for the Atacama Large Millimeter / submillimeter Array (ALMA). The ALMA Band 9 receiver units ("cartridges"), which are installed in the telescope's front end, have been designed to detect and down-convert two orthogonal linear polarization components of the light collected by the ALMA antennas. The light entering the front end is refocused with a compact arrangement of mirrors, which is fully contained within the cartridge. The arrangement contains a grid to separate the polarizations and two beam splitters to combine each resulting beam with a local oscillator signal. The combined beams are fed into independent double-sideband mixers, each with a corrugated feedhorn coupling the radiation by way of a waveguide with backshort cavity into an impedance-tuned SIS junction that performs the heterodyne down-conversion. Finally, the generated intermediate frequency signals are amplified by cryogenic and room-temperature HEMT amplifiers and exported to the telescope's back end for further processing and, finally, correlation. The receivers have been constructed and tested in the laboratory and they show excellent performance, complying with ALMA requirements. Performance statistics on all 73 Band 9 receivers are reported. On-sky characterization and tests of the performance of the Band 9 cartridges are presented using commissioning data.
△ Less
Submitted 6 March, 2015;
originally announced March 2015.
-
Performance of Hybrid NbTiN-Al Microwave Kinetic Inductance Detectors as Direct Detectors for Sub-millimeter Astronomy
Authors:
R. M. J. Janssen,
J. J. A. Baselmans,
A. Endo,
L. Ferrari,
S. J. C. Yates,
A. M. Baryshev,
T. M. Klapwijk
Abstract:
In the next decades millimeter and sub-mm astronomy requires large format imaging arrays and broad-band spectrometers to complement the high spatial and spectral resolution of the Atacama Large Millimeter/sub-millimeter Array. The desired sensors for these instruments should have a background limited sensitivity and a high optical efficiency and enable arrays thousands of pixels in size. Hybrid mi…
▽ More
In the next decades millimeter and sub-mm astronomy requires large format imaging arrays and broad-band spectrometers to complement the high spatial and spectral resolution of the Atacama Large Millimeter/sub-millimeter Array. The desired sensors for these instruments should have a background limited sensitivity and a high optical efficiency and enable arrays thousands of pixels in size. Hybrid microwave kinetic inductance detectors consisting of NbTiN and Al have shown to satisfy these requirements. We present the second generation hybrid NbTiN-Al MKIDs, which are photon noise limited in both phase and amplitude readout for loading levels $P_{850GHz} \geq 10$ fW. Thanks to the increased responsivity, the photon noise level achieved in phase allows us to simultaneously read out approximately 8000 pixels using state-of-the-art electronics. In addition, the choice of superconducting materials and the use of a Si lens in combination with a planar antenna gives these resonators the flexibility to operate within the frequency range $0.09 < ν< 1.1$ THz. Given these specifications, hybrid NbTiN-Al MKIDs will enable astronomically usable kilopixel arrays for sub-mm imaging and moderate resolution spectroscopy.
△ Less
Submitted 14 August, 2014;
originally announced August 2014.
-
High optical efficiency and photon noise limited sensitivity of microwave kinetic inductance detectors using phase readout
Authors:
R. M. J. Janssen,
J. J. A. Baselmans,
A. Endo,
L. Ferrari,
S. J. C. Yates,
A. M. Baryshev,
T. M. Klapwijk
Abstract:
We demonstrate photon noise limited performance in both phase and amplitude readout in microwave kinetic inductance detectors (MKIDs) consisting of NbTiN and Al, down to 100 fW of optical power. We simulate the far field beam pattern of the lens-antenna system used to couple radiation into the MKID and derive an aperture efficiency of 75%. This is close to the theoretical maximum of 80% for a sing…
▽ More
We demonstrate photon noise limited performance in both phase and amplitude readout in microwave kinetic inductance detectors (MKIDs) consisting of NbTiN and Al, down to 100 fW of optical power. We simulate the far field beam pattern of the lens-antenna system used to couple radiation into the MKID and derive an aperture efficiency of 75%. This is close to the theoretical maximum of 80% for a single-moded detector. The beam patterns are verified by a detailed analysis of the optical coupling within our measurement setup.
△ Less
Submitted 11 November, 2013;
originally announced November 2013.
-
On-chip filter bank spectroscopy at 600-700 GHz using NbTiN superconducting resonators
Authors:
A. Endo,
C. Sfiligoj,
S. J. C. Yates,
J. J. A. Baselmans,
D. J. Thoen,
S. M. H. Javadzadeh,
P. P. van der Werf,
A. M. Baryshev,
T. M. Klapwijk
Abstract:
We experimentally demonstrate the principle of an on-chip submillimeter wave filter bank spectrometer, using superconducting microresonators as narrow band-separation filters. The filters are made of NbTiN/SiNx/NbTiN microstrip line resonators, which have a resonance frequency in the range of 614-685 GHz---two orders of magnitude higher in frequency than what is currently studied for use in circui…
▽ More
We experimentally demonstrate the principle of an on-chip submillimeter wave filter bank spectrometer, using superconducting microresonators as narrow band-separation filters. The filters are made of NbTiN/SiNx/NbTiN microstrip line resonators, which have a resonance frequency in the range of 614-685 GHz---two orders of magnitude higher in frequency than what is currently studied for use in circuit quantum electrodynamics and photodetectors. The frequency resolution of the filters decreases from 350 to 140 with increasing frequency, most likely limited by dissipation of the resonators.
△ Less
Submitted 21 June, 2013; v1 submitted 28 March, 2013;
originally announced March 2013.
-
Photon noise limited radiation detection with lens-antenna coupled Microwave Kinetic Inductance Detectors
Authors:
S. J. C. Yates,
J. J. A. Baselmans,
A. Endo,
R. M. J. Janssen,
L. Ferrari,
P. Diener,
A. M. Baryshev
Abstract:
Microwave Kinetic Inductance Detectors (MKIDs) have shown great potential for sub-mm instrumentation because of the high scalability of the technology. Here we demonstrate for the first time in the sub-mm band (0.1...2 mm) a photon noise limited performance of a small antenna coupled MKID detector array and we describe the relation between photon noise and MKID intrinsic generation-recombination n…
▽ More
Microwave Kinetic Inductance Detectors (MKIDs) have shown great potential for sub-mm instrumentation because of the high scalability of the technology. Here we demonstrate for the first time in the sub-mm band (0.1...2 mm) a photon noise limited performance of a small antenna coupled MKID detector array and we describe the relation between photon noise and MKID intrinsic generation-recombination noise. Additionally we use the observed photon noise to measure the optical efficiency of detectors to be 0.8+-0.2.
△ Less
Submitted 21 July, 2011;
originally announced July 2011.
-
Integrated Filterbank for DESHIMA: A Submillimeter Imaging Spectrograph Based on Superconducting Resonators
Authors:
A. Endo,
P. van der Werf,
R. M. J. Janssen,
P. J. de Visser,
T. M. Klapwijk,
J. J. A. Baselmans,
L. Ferrari,
A. M. Baryshev,
S. J. C. Yates
Abstract:
An integrated filterbank (IFB) in combination with microwave kinetic inductance detectors (MKIDs), both based on superconducting resonators, could be used to make broadband submillimeter imaging spectrographs that are compact and flexible. In order to investigate the possibility of adopting an IFB configuration for DESHIMA (Delft SRON High-redshift Mapper), we study the basic properties of a copla…
▽ More
An integrated filterbank (IFB) in combination with microwave kinetic inductance detectors (MKIDs), both based on superconducting resonators, could be used to make broadband submillimeter imaging spectrographs that are compact and flexible. In order to investigate the possibility of adopting an IFB configuration for DESHIMA (Delft SRON High-redshift Mapper), we study the basic properties of a coplanar-waveguide-based IFB using electromagnetic simulation. We show that a coupling efficiency greater than 1/2 can be achieved if transmission losses are negligible. We arrive at a practical design for a 9 pixel x 920 color 3 dimensional imaging device that fits on a 4 inch wafer, which instantaneously covers multiple submillimeter telluric windows with a dispersion of f/df = 1000.
△ Less
Submitted 17 July, 2011;
originally announced July 2011.
-
A dual-band millimeter-wave kinetic inductance camera for the IRAM 30-meter telescope
Authors:
A. Monfardini,
A. Benoit,
A. Bideaud,
L. J. Swenson,
M. Roesch,
F. X. Desert,
S. Doyle,
A. Endo,
A. Cruciani,
P. Ade,
A. M. Baryshev,
J. J. A. Baselmans,
O. Bourrion,
M. Calvo,
P. Camus,
L. Ferrari,
C. Giordano,
C. Hoffmann,
S. Leclercq,
J. F. Macias-Perez,
P. Mauskopf,
K. F. Schuster,
C. Tucker,
C. Vescovi,
S. J. C. Yates
Abstract:
Context. The Neel IRAM KIDs Array (NIKA) is a fully-integrated measurement system based on kinetic inductance detectors (KIDs) currently being developed for millimeter wave astronomy. In a first technical run, NIKA was successfully tested in 2009 at the Institute for Millimetric Radio Astronomy (IRAM) 30-meter telescope at Pico Veleta, Spain. This prototype consisted of a 27-42 pixel camera imagin…
▽ More
Context. The Neel IRAM KIDs Array (NIKA) is a fully-integrated measurement system based on kinetic inductance detectors (KIDs) currently being developed for millimeter wave astronomy. In a first technical run, NIKA was successfully tested in 2009 at the Institute for Millimetric Radio Astronomy (IRAM) 30-meter telescope at Pico Veleta, Spain. This prototype consisted of a 27-42 pixel camera imaging at 150 GHz. Subsequently, an improved system has been developed and tested in October 2010 at the Pico Veleta telescope. The instrument upgrades included dual-band optics allowing simultaneous imaging at 150 GHz and 220 GHz, faster sampling electronics enabling synchronous measurement of up to 112 pixels per measurement band, improved single-pixel sensitivity, and the fabrication of a sky simulator to replicate conditions present at the telescope. Results. The new dual-band NIKA was successfully tested in October 2010, performing in-line with sky simulator predictions. Initially the sources targeted during the 2009 run were re-imaged, verifying the improved system performance. An optical NEP was then calculated to be around 2 \dot 10-16 W/Hz1/2. This improvement in comparison with the 2009 run verifies that NIKA is approaching the target sensitivity for photon-noise limited ground-based detectors. Taking advantage of the larger arrays and increased sensitivity, a number of scientifically-relevant faint and extended objects were then imaged including the Galactic Center SgrB2(FIR1), the radio galaxy Cygnus A and the NGC1068 Seyfert galaxy. These targets were all observed simultaneously in the 150 GHz and 220 GHz atmospheric windows.
△ Less
Submitted 8 February, 2011; v1 submitted 4 February, 2011;
originally announced February 2011.
-
NIKA: A millimeter-wave kinetic inductance camera
Authors:
A. Monfardini,
L. J. Swenson,
A. Bideaud,
F. X. Désert,
S. J. C. Yates,
A. Benoit,
A. M. Baryshev,
J. J. A. Baselmans,
S. Doyle,
B. Klein,
M. Roesch,
C. Tucker,
P. Ade,
M. Calvo,
P. Camus,
C. Giordano,
R. Guesten,
C. Hoffmann,
S. Leclercq,
P. Mauskopf,
K. F. Schuster
Abstract:
Current generation millimeter wavelength detectors suffer from scaling limits imposed by complex cryogenic readout electronics. To circumvent this it is imperative to investigate technologies that intrinsically incorporate strong multiplexing. One possible solution is the kinetic inductance detector (KID). In order to assess the potential of this nascent technology, a prototype instrument optimize…
▽ More
Current generation millimeter wavelength detectors suffer from scaling limits imposed by complex cryogenic readout electronics. To circumvent this it is imperative to investigate technologies that intrinsically incorporate strong multiplexing. One possible solution is the kinetic inductance detector (KID). In order to assess the potential of this nascent technology, a prototype instrument optimized for the 2 mm atmospheric window was constructed. Known as the Néel IRAM KIDs Array (NIKA), it was recently tested at the Institute for Millimetric Radio Astronomy (IRAM) 30-meter telescope at Pico Veleta, Spain. The measurement resulted in the imaging of a number of sources, including planets, quasars, and galaxies. The images for Mars, radio star MWC349, quasar 3C345, and galaxy M87 are presented. From these results, the optical NEP was calculated to be around $1 \times 10^{-15}$ W$ / $Hz$^{1/2}$. A factor of 10 improvement is expected to be readily feasible by improvements in the detector materials and reduction of performance-degrading spurious radiation.
△ Less
Submitted 20 June, 2010; v1 submitted 13 April, 2010;
originally announced April 2010.
-
FFTS readout for large arrays of Microwave Kinetic Inductance Detectors
Authors:
S. J. C. Yates,
A. M. Baryshev,
J. J. A. Baselmans,
B. Klein,
R. Güsten
Abstract:
Microwave Kinetic Inductance Detectors (MKIDs) have great potential for large very sensitive detector arrays for use in, for example, sub-mm imaging. Being intrinsically readout in the frequency domain, they are particularly suited for frequency domain multiplexing allowing $\sim$1000s of devices to be readout with one pair of coaxial cables. However, this moves the complexity of the detector fr…
▽ More
Microwave Kinetic Inductance Detectors (MKIDs) have great potential for large very sensitive detector arrays for use in, for example, sub-mm imaging. Being intrinsically readout in the frequency domain, they are particularly suited for frequency domain multiplexing allowing $\sim$1000s of devices to be readout with one pair of coaxial cables. However, this moves the complexity of the detector from the cryogenics to the warm electronics. We present here the concept and experimental demonstration of the use of Fast Fourier Transform Spectrometer (FFTS) readout, showing no deterioration of the noise performance compared to low noise analog mixing while allowing high multiplexing ratios.
△ Less
Submitted 13 March, 2009;
originally announced March 2009.