Skip to main content

Showing 1–7 of 7 results for author: Barvich, T

.
  1. arXiv:1706.00222  [pdf, other

    physics.ins-det hep-ex

    Test Beam Performance Measurements for the Phase I Upgrade of the CMS Pixel Detector

    Authors: M. Dragicevic, M. Friedl, J. Hrubec, H. Steininger, A. Gädda, J. Härkönen, T. Lampén, P. Luukka, T. Peltola, E. Tuominen, E. Tuovinen, A. Winkler, P. Eerola, T. Tuuva, G. Baulieu, G. Boudoul, L. Caponetto, C. Combaret, D. Contardo, T. Dupasquier, G. Gallbit, N. Lumb, L. Mirabito, S. Perries, M. Vander Donckt , et al. (462 additional authors not shown)

    Abstract: A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator… ▽ More

    Submitted 1 June, 2017; originally announced June 2017.

    Report number: CMS-NOTE-2017-002

  2. Trap** in irradiated p-on-n silicon sensors at fluences anticipated at the HL-LHC outer tracker

    Authors: W. Adam, T. Bergauer, M. Dragicevic, M. Friedl, R. Fruehwirth, M. Hoch, J. Hrubec, M. Krammer, W. Treberspurg, W. Waltenberger, S. Alderweireldt, W. Beaumont, X. Janssen, S. Luyckx, P. Van Mechelen, N. Van Remortel, A. Van Spilbeeck, P. Barria, C. Caillol, B. Clerbaux, G. De Lentdecker, D. Dobur, L. Favart, A. Grebenyuk, Th. Lenzi , et al. (663 additional authors not shown)

    Abstract: The degradation of signal in silicon sensors is studied under conditions expected at the CERN High-Luminosity LHC. 200 $μ$m thick n-type silicon sensors are irradiated with protons of different energies to fluences of up to $3 \cdot 10^{15}$ neq/cm$^2$. Pulsed red laser light with a wavelength of 672 nm is used to generate electron-hole pairs in the sensors. The induced signals are used to determi… ▽ More

    Submitted 7 May, 2015; originally announced May 2015.

    Journal ref: 2016 JINST 11 P04023

  3. arXiv:1212.2160  [pdf, other

    physics.ins-det hep-ex

    DEPFET active pixel detectors for a future linear $e^+e^-$ collider

    Authors: O. Alonso, R. Casanova, A. Dieguez, J. Dingfelder, T. Hemperek, T. Kishishita amd T. Kleinohl, M. Koch, H. Krueger, M. Lemarenko, F. Luetticke, C. Marinas, M. Schnell, N. Wermes, A. Campbell, T. Ferber, C. Kleinwort, C. Niebuhr, Y. Soloviev, M. Steder, R. Volkenborn, S. Yaschenko, P. Fischer, C. Kreidl, I. Peric, J. Knopf , et al. (62 additional authors not shown)

    Abstract: The DEPFET collaboration develops highly granular, ultra-transparent active pixel detectors for high-performance vertex reconstruction at future collider experiments. The characterization of detector prototypes has proven that the key principle, the integration of a first amplification stage in a detector-grade sensor material, can provide a comfortable signal to noise ratio of over 40 for a senso… ▽ More

    Submitted 10 December, 2012; originally announced December 2012.

    Comments: 10 pages

  4. arXiv:1011.0352  [pdf

    physics.ins-det hep-ex

    Belle II Technical Design Report

    Authors: T. Abe, I. Adachi, K. Adamczyk, S. Ahn, H. Aihara, K. Akai, M. Aloi, L. Andricek, K. Aoki, Y. Arai, A. Arefiev, K. Arinstein, Y. Arita, D. M. Asner, V. Aulchenko, T. Aushev, T. Aziz, A. M. Bakich, V. Balagura, Y. Ban, E. Barberio, T. Barvich, K. Belous, T. Bergauer, V. Bhardwaj , et al. (387 additional authors not shown)

    Abstract: The Belle detector at the KEKB electron-positron collider has collected almost 1 billion Y(4S) events in its decade of operation. Super-KEKB, an upgrade of KEKB is under construction, to increase the luminosity by two orders of magnitude during a three-year shutdown, with an ultimate goal of 8E35 /cm^2 /s luminosity. To exploit the increased luminosity, an upgrade of the Belle detector has been pr… ▽ More

    Submitted 1 November, 2010; originally announced November 2010.

    Comments: Edited by: Z. Doležal and S. Uno

    Report number: KEK Report 2010-1

  5. arXiv:1008.4107  [pdf, other

    physics.ins-det hep-ex

    Czochralski Silicon as a Detector Material for S-LHC Tracker Volumes

    Authors: Leonard Spiegel, Tobias Barvich, Burt Betchart, Saptaparna Bhattacharya, Sandor Czellar, Regina Demina, Alexander Dierlamm, Martin Frey, Yuri Gotra, Jaakko Härkönen, Frank Hartmann, Ivan Kassamakov, Sergey Korjenevski, Matti J. Kortelainen, Tapio Lampén, Teppo Mäenpää, Henri Moilanen, Meenakshi Narain, Maike Neuland, Douglas Orbaker, Hans-Jürgen Simonis, Pia Steck, Eija Tuominen, Esa Tuovinen

    Abstract: With an expected ten-fold increase in luminosity in S-LHC, the radiation environment in the tracker volumes will be considerably harsher for silicon-based detectors than the already harsh LHC environment. Since 2006, a group of CMS institutes, using a modified CMS DAQ system, has been exploring the use of Magnetic Czochralski silicon as a detector element for the strip tracker layers in S-LHC expe… ▽ More

    Submitted 24 August, 2010; originally announced August 2010.

    Comments: 4 pages, 6 figures, 12th Vienna Conference on Instrumentation

    Report number: Fermilab-PUB-10-298-E

    Journal ref: Nucl.Instrum.Meth.A628:242-245,2011

  6. arXiv:0901.4815  [pdf, other

    physics.ins-det

    Silicon Detectors for the Large Prototype TPC test setup at DESY

    Authors: S. Haensel, T. Bergauer, M. Dragicevic, J. Hrubec, M. Krammer, A. Dierlamm, T. Barvich, F. Hartmann, Th. Müller

    Abstract: The Linear Collider TPC collaboration constructed a Large Prototype TPC (LPTPC) which is now installed at the EUDET facility, in DESY. The SiLC-collaboration (Silicon for the Linear Collider) will install position sensitive silicon strip sensors outside the field cage of the LPTPC, to provide precise tracking information. The data acquisition system (DAQ) is an adapted CMS readout system. The si… ▽ More

    Submitted 19 February, 2009; v1 submitted 30 January, 2009; originally announced January 2009.

    Comments: proceeding of the International Linear Collider Workshop 2008 (LCWS08); corrected typos and added reference for section 1

  7. Construction and Performance of a Micro-Pattern Stereo Detector with Two Gas Electron Multipliers

    Authors: T. Barvich, P. Bluem, M. Erdmann, M. Fahrer, K. Kaercher, F. Kuehn, D. Moermann, Th. Mueller, D. Neuberger, F. Roederer, H. J. Simonis, A. Skiba, W. H. Thuemmel, Th. Weiler, S. Weseler

    Abstract: The construction of a micro-pattern gas detector of dimensions 40x10 cm**2 is described. Two gas electron multiplier foils (GEM) provide the internal amplification stages. A two-layer readout structure was used, manufactured in the same technology as the GEM foils. The strips of each layer cross at an effective crossing angle of 6.7 degrees and have a 406 um pitch. The performance of the detecto… ▽ More

    Submitted 4 October, 2001; originally announced October 2001.

    Comments: 21 pages, 17 figures

    Report number: IEKP-KA/2001-20

    Journal ref: Nucl.Instrum.Meth. A485 (2002) 477-489