-
The TES-based Cryogenic AntiCoincidence Detector (CryoAC) of ATHENA X-IFU: a large area silicon microcalorimeter for background particles detection
Authors:
M. D'Andrea,
C. Macculi,
S. Lotti,
L. Piro,
A. Argan,
G. Minervini,
G. Torrioli,
F. Chiarello,
L. Ferrari Barusso,
E. Celasco,
G. Gallucci,
F. Gatti,
D. Grosso,
M. Rigano,
D. Brienza,
E. Cavazzuti,
A. Volpe
Abstract:
We are develo** the Cryogenic AntiCoincidence detector (CryoAC) of the ATHENA X-IFU spectrometer. It is a TES-based particle detector aimed to reduce the background of the instrument. Here, we present the result obtained with the last CryoAC single-pixel prototype. It is based on a 1 cm2 silicon absorber sensed by a single 2mm x 1mm Ir/Au TES, featuring an on-chip heater for calibration and diag…
▽ More
We are develo** the Cryogenic AntiCoincidence detector (CryoAC) of the ATHENA X-IFU spectrometer. It is a TES-based particle detector aimed to reduce the background of the instrument. Here, we present the result obtained with the last CryoAC single-pixel prototype. It is based on a 1 cm2 silicon absorber sensed by a single 2mm x 1mm Ir/Au TES, featuring an on-chip heater for calibration and diagnostic purposes. We have illuminated the sample with 55Fe (6 keV line) and 241Am (60 keV line) radioactive sources, thus studying the detector response and the heater calibration accuracy at low energy. Furthermore, we have operated the sample in combination with a past-generation CryoAC prototype. Here, by analyzing the coincident detections between the two detectors, we have been able to characterize the background spectrum of the laboratory environment and disentangle the primary (i.e. cosmic muons) and secondaries (mostly secondary photons and electrons) signatures in the spectral shape.
△ Less
Submitted 19 January, 2024;
originally announced January 2024.
-
A search for $μ^+\to e^+γ$ with the first dataset of the MEG II experiment
Authors:
MEG II collaboration,
K. Afanaciev,
A. M. Baldini,
S. Ban,
V. Baranov,
H. Benmansour,
M. Biasotti,
G. Boca,
P. W. Cattaneo,
G. Cavoto,
F. Cei,
M. Chiappini,
G. Chiarello,
A. Corvaglia,
F. Cuna,
G. Dal Maso,
A. De Bari,
M. De Gerone,
L. Ferrari Barusso,
M. Francesconi,
L. Galli,
G. Gallucci,
F. Gatti,
L. Gerritzen,
F. Grancagnolo
, et al. (57 additional authors not shown)
Abstract:
The MEG II experiment, based at the Paul Scherrer Institut in Switzerland, reports the result of a search for the decay $μ^+\to e^+γ$ from data taken in the first physics run in 2021. No excess of events over the expected background is observed, yielding an upper limit on the branching ratio of B($μ^+\to e^+γ$) < $7.5 \times 10^{-13}$ (90% C.L.). The combination of this result and the limit obtain…
▽ More
The MEG II experiment, based at the Paul Scherrer Institut in Switzerland, reports the result of a search for the decay $μ^+\to e^+γ$ from data taken in the first physics run in 2021. No excess of events over the expected background is observed, yielding an upper limit on the branching ratio of B($μ^+\to e^+γ$) < $7.5 \times 10^{-13}$ (90% C.L.). The combination of this result and the limit obtained by MEG gives B($μ^+\to e^+γ$) < $3.1 \times 10^{-13}$ (90% C.L.), which is the most stringent limit to date. A ten-fold larger sample of data is being collected during the years 2022-2023, and data-taking will continue in the coming years.
△ Less
Submitted 7 January, 2024; v1 submitted 19 October, 2023;
originally announced October 2023.
-
Operation and performance of MEG II detector
Authors:
MEG II Collaboration,
K. Afanaciev,
A. M. Baldini,
S. Ban,
V. Baranov,
H. Benmansour,
M. Biasotti,
G. Boca,
P. W. Cattaneo,
G. Cavoto,
F. Cei,
M. Chiappini,
G. Chiarello,
A. Corvaglia,
F. Cuna,
G. Dal Maso,
A. De Bari,
M. De Gerone,
L. Ferrari Barusso,
M. Francesconi,
L. Galli,
G. Gallucci,
F. Gatti,
L. Gerritzen,
F. Grancagnolo
, et al. (60 additional authors not shown)
Abstract:
The MEG II experiment, located at the Paul Scherrer Institut (PSI) in Switzerland, is the successor to the MEG experiment, which completed data taking in 2013. MEG II started fully operational data taking in 2021, with the goal of improving the sensitivity of the mu+ -> e+ gamma decay down to 6e-14 almost an order of magnitude better than the current limit. In this paper, we describe the operation…
▽ More
The MEG II experiment, located at the Paul Scherrer Institut (PSI) in Switzerland, is the successor to the MEG experiment, which completed data taking in 2013. MEG II started fully operational data taking in 2021, with the goal of improving the sensitivity of the mu+ -> e+ gamma decay down to 6e-14 almost an order of magnitude better than the current limit. In this paper, we describe the operation and performance of the experiment and give a new estimate of its sensitivity versus data acquisition time.
△ Less
Submitted 8 January, 2024; v1 submitted 18 October, 2023;
originally announced October 2023.
-
The Athena X-ray Integral Field Unit: a consolidated design for the system requirement review of the preliminary definition phase
Authors:
Didier Barret,
Vincent Albouys,
Jan-Willem den Herder,
Luigi Piro,
Massimo Cappi,
Juhani Huovelin,
Richard Kelley,
J. Miguel Mas-Hesse,
Stéphane Paltani,
Gregor Rauw,
Agata Rozanska,
Jiri Svoboda,
Joern Wilms,
Noriko Yamasaki,
Marc Audard,
Simon Bandler,
Marco Barbera,
Xavier Barcons,
Enrico Bozzo,
Maria Teresa Ceballos,
Ivan Charles,
Elisa Costantini,
Thomas Dauser,
Anne Decourchelle,
Lionel Duband
, et al. (274 additional authors not shown)
Abstract:
The Athena X-ray Integral Unit (X-IFU) is the high resolution X-ray spectrometer, studied since 2015 for flying in the mid-30s on the Athena space X-ray Observatory, a versatile observatory designed to address the Hot and Energetic Universe science theme, selected in November 2013 by the Survey Science Committee. Based on a large format array of Transition Edge Sensors (TES), it aims to provide sp…
▽ More
The Athena X-ray Integral Unit (X-IFU) is the high resolution X-ray spectrometer, studied since 2015 for flying in the mid-30s on the Athena space X-ray Observatory, a versatile observatory designed to address the Hot and Energetic Universe science theme, selected in November 2013 by the Survey Science Committee. Based on a large format array of Transition Edge Sensors (TES), it aims to provide spatially resolved X-ray spectroscopy, with a spectral resolution of 2.5 eV (up to 7 keV) over an hexagonal field of view of 5 arc minutes (equivalent diameter). The X-IFU entered its System Requirement Review (SRR) in June 2022, at about the same time when ESA called for an overall X-IFU redesign (including the X-IFU cryostat and the cooling chain), due to an unanticipated cost overrun of Athena. In this paper, after illustrating the breakthrough capabilities of the X-IFU, we describe the instrument as presented at its SRR, browsing through all the subsystems and associated requirements. We then show the instrument budgets, with a particular emphasis on the anticipated budgets of some of its key performance parameters. Finally we briefly discuss on the ongoing key technology demonstration activities, the calibration and the activities foreseen in the X-IFU Instrument Science Center, and touch on communication and outreach activities, the consortium organisation, and finally on the life cycle assessment of X-IFU aiming at minimising the environmental footprint, associated with the development of the instrument. Thanks to the studies conducted so far on X-IFU, it is expected that along the design-to-cost exercise requested by ESA, the X-IFU will maintain flagship capabilities in spatially resolved high resolution X-ray spectroscopy, enabling most of the original X-IFU related scientific objectives of the Athena mission to be retained. (abridged).
△ Less
Submitted 28 November, 2022; v1 submitted 30 August, 2022;
originally announced August 2022.
-
ATHENA X-IFU Demonstration Model: First joint operation of the main TES Array and its Cryogenic AntiCoincidence Detector (CryoAC)
Authors:
M. D'Andrea,
K. Ravensberg,
A. Argan,
D. Brienza,
S. Lotti,
C. Macculi,
G. Minervini,
L. Piro,
G. Torrioli,
F. Chiarello,
L. Ferrari Barusso,
M. Biasotti,
G. Gallucci,
F. Gatti,
M. Rigano,
H. Akamatsu,
J. Dercksen,
L. Gottardi,
F. de Groote,
R. den Hartog,
J. -W. den Herder,
R. Hoogeveen,
B. Jackson,
A. McCalden,
S. Rosman
, et al. (6 additional authors not shown)
Abstract:
The X-IFU is the cryogenic spectrometer onboard the future ATHENA X-ray observatory. It is based on a large array of TES microcalorimeters, which works in combination with a Cryogenic AntiCoincidence detector (CryoAC). This is necessary to reduce the particle background level thus enabling part of the mission science goals. Here we present the first joint test of X-IFU TES array and CryoAC Demonst…
▽ More
The X-IFU is the cryogenic spectrometer onboard the future ATHENA X-ray observatory. It is based on a large array of TES microcalorimeters, which works in combination with a Cryogenic AntiCoincidence detector (CryoAC). This is necessary to reduce the particle background level thus enabling part of the mission science goals. Here we present the first joint test of X-IFU TES array and CryoAC Demonstration Models, performed in a FDM setup. We show that it is possible to operate properly both detectors, and we provide a preliminary demonstration of the anti-coincidence capability of the system achieved by the simultaneous detection of cosmic muons.
△ Less
Submitted 30 June, 2022;
originally announced June 2022.
-
The large scale polarization explorer (LSPE) for CMB measurements: performance forecast
Authors:
The LSPE collaboration,
G. Addamo,
P. A. R. Ade,
C. Baccigalupi,
A. M. Baldini,
P. M. Battaglia,
E. S. Battistelli,
A. Baù,
P. de Bernardis,
M. Bersanelli,
M. Biasotti,
A. Boscaleri,
B. Caccianiga,
S. Caprioli,
F. Cavaliere,
F. Cei,
K. A. Cleary,
F. Columbro,
G. Coppi,
A. Coppolecchia,
F. Cuttaia,
G. D'Alessandro,
G. De Gasperis,
M. De Petris,
V. Fafone
, et al. (80 additional authors not shown)
Abstract:
[Abridged] The measurement of the polarization of the Cosmic Microwave Background radiation is one of the current frontiers in cosmology. In particular, the detection of the primordial B-modes, could reveal the presence of gravitational waves in the early Universe. The detection of such component is at the moment the most promising technique to probe the inflationary theory describing the very ear…
▽ More
[Abridged] The measurement of the polarization of the Cosmic Microwave Background radiation is one of the current frontiers in cosmology. In particular, the detection of the primordial B-modes, could reveal the presence of gravitational waves in the early Universe. The detection of such component is at the moment the most promising technique to probe the inflationary theory describing the very early evolution of the Universe. We present the updated performance forecast of the Large Scale Polarization Explorer (LSPE), a program dedicated to the measurement of the CMB polarization. LSPE is composed of two instruments: Strip, a radiometer-based telescope on the ground in Tenerife, and SWIPE (Short-Wavelength Instrument for the Polarization Explorer) a bolometer-based instrument designed to fly on a winter arctic stratospheric long-duration balloon. The program is among the few dedicated to observation of the Northern Hemisphere, while most of the international effort is focused into ground-based observation in the Southern Hemisphere. Measurements are currently scheduled in Winter 2021/22 for SWIPE, with a flight duration up to 15 days, and in Summer 2021 with two years observations for Strip. We describe the main features of the two instruments, identifying the most critical aspects of the design, in terms of impact into performance forecast. We estimate the expected sensitivity of each instrument and propagate their combined observing power to the sensitivity to cosmological parameters, including the effect of scanning strategy, component separation, residual foregrounds and partial sky coverage. We also set requirements on the control of the most critical systematic effects and describe techniques to mitigate their impact. LSPE can reach a sensitivity in tensor-to-scalar ratio of $σ_r<0.01$, and improve constrains on other cosmological parameters.
△ Less
Submitted 9 August, 2021; v1 submitted 25 August, 2020;
originally announced August 2020.
-
The Demonstration Model of the ATHENA X-IFU Cryogenic AntiCoincidence Detector
Authors:
Matteo D'Andrea,
Claudio Macculi,
Guido Torrioli,
Andrea Argan,
Daniele Brienza,
Simone Lotti,
Gabriele Minervini,
Luigi Piro,
Michele Biasotti,
Lorenzo Ferrari Barusso,
Flavio Gatti,
Manuela Rigano,
Angela Volpe,
Elia Stefano Battistelli
Abstract:
The Cryogenic AntiCoincidence Detector (CryoAC) of ATHENA X-IFU is designed to reduce the particle background of the instrument and to enable the mission science goals. It is a 4 pixel silicon microcalorimeter sensed by an Ir/Au TES network. We have developed the CryoAC Demonstration Model, a prototype aimed to probe the critical technologies of the detector, i.e. the suspended absorber with an ac…
▽ More
The Cryogenic AntiCoincidence Detector (CryoAC) of ATHENA X-IFU is designed to reduce the particle background of the instrument and to enable the mission science goals. It is a 4 pixel silicon microcalorimeter sensed by an Ir/Au TES network. We have developed the CryoAC Demonstration Model, a prototype aimed to probe the critical technologies of the detector, i.e. the suspended absorber with an active area of 1 cm2; the low energy threshold of 20 keV; and the operation connected to a 50 mK thermal bath with a power dissipation less than 40 nW. Here we report the test performed on the first CryoAC DM sample (namely the AC-S10 prototype), showing that it is fully compliant with its requirements.
△ Less
Submitted 13 December, 2019;
originally announced December 2019.