Skip to main content

Showing 1–4 of 4 results for author: Bart, S

.
  1. arXiv:0903.5201  [pdf

    physics.med-ph cs.OH

    Map** of transrectal ultrasonographic prostate biopsies: quality control and learning curve assessment by image processing

    Authors: Pierre Mozer, Michael Baumann, Gregoire Chevreau, Alexandre Moreau-Gaudry, Stephane Bart, Raphaele Renard-Penna, Eva Comperat, Pierre Conort, Marc-Olivier Bitker, Emmanuel Chartier-Kastler, Francois Richard, Jocelyne Troccaz

    Abstract: Objective: Map** of transrectal ultrasonographic (TRUS) prostate biopsies is of fundamental importance for either diagnostic purposes or the management and treatment of prostate cancer, but the localization of the cores seems inaccurate. Our objective was to evaluate the capacities of an operator to plan transrectal prostate biopsies under 2-dimensional TRUS guidance using a registration algor… ▽ More

    Submitted 30 March, 2009; originally announced March 2009.

    Journal ref: Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine 28, 4 (2009) 455-60

  2. arXiv:0712.2100  [pdf

    cs.OH cs.RO

    Medical image computing and computer-aided medical interventions applied to soft tissues. Work in progress in urology

    Authors: Jocelyne Troccaz, Michael Baumann, Peter Berkelman, Philippe Cinquin, Vincent Daanen, Antoine Leroy, Maud Marchal, Yohan Payan, Emmanuel Promayon, Sandrine Voros, Stéphane Bart, Michel Bolla, Emmanuel Chartier-Kastler, Jean-Luc Descotes, Andrée Dusserre, Jean-Yves Giraud, Jean-Alexandre Long, Ronan Moalic, Pierre Mozer

    Abstract: Until recently, Computer-Aided Medical Interventions (CAMI) and Medical Robotics have focused on rigid and non deformable anatomical structures. Nowadays, special attention is paid to soft tissues, raising complex issues due to their mobility and deformation. Mini-invasive digestive surgery was probably one of the first fields where soft tissues were handled through the development of simulators… ▽ More

    Submitted 13 December, 2007; originally announced December 2007.

    Journal ref: Proceedings of the IEEE 94, 9 (2006) 1665-1677

  3. Weak decays of 4He-Lambda

    Authors: J. D. Parker, M. J. Athanas, P. D. Barnes, S. Bart, B. Bassalleck, R. Chrien, G. Diebold, G. B. Franklin, K. Johnston, P. Pile, B. Quinn, F. Rozon, R. Sawafta, R. A. Schumacher, R. Stearns, I. Sukaton, R. Sutter, J. J. Szymanski, V. J. Zeps

    Abstract: We measured the lifetime and the mesonic and non-mesonic decay rates of the 4He-Lambda hypernucleus. The hypernuclei were created using a 750 MeV/c momentum K- beam on a liquid 4He target by the reaction 4He(K-,pi-)4He-Lambda. The 4He-Lambda lifetime was directly measured using protons from Lambda p -> n p non-mesonic decay (also referred to as proton-stimulated decay) and was found to have a va… ▽ More

    Submitted 13 September, 2007; v1 submitted 23 May, 2007; originally announced May 2007.

    Comments: 15 pages, 11 figures, published in PRC, revised content to match published version

    Journal ref: Phys.Rev.C76:035501,2007; Erratum-ibid.C75:039904,2007

  4. K$^+$-nucleus quasielastic scattering

    Authors: C. M. Kormanyos, R. J. Peterson, J. R. Shepard, J. E. Wise, S. Bart, R. E. Chrien, L. Lee, B. L. Clausen, J. Piekarewicz, M. B. Barakat, R. A. Michael, T. Kishimoto

    Abstract: K$^+$--nucleus quasielastic cross sections measured for a laboratory kaon beam momentum of 705 MeV/$c$ are presented for 3--momentum transfers of 300 and 500 MeV/$c$. The measured differential cross sections for C, Ca and Pb at 500 MeV/$c$ are used to deduce the effective number of nucleons participating in the scattering, which are compared with estimates based on the eikonal approximation. The… ▽ More

    Submitted 30 July, 1993; originally announced July 1993.

    Comments: 8 pages University of Colorado Nuclear Physics Lab. Preprint NPL-1098. 2 PostScript figures available on request from J.Shepard at ``[email protected]''

    Journal ref: Phys.Rev.Lett. 71 (1993) 2571-2574