-
Map** of transrectal ultrasonographic prostate biopsies: quality control and learning curve assessment by image processing
Authors:
Pierre Mozer,
Michael Baumann,
Gregoire Chevreau,
Alexandre Moreau-Gaudry,
Stephane Bart,
Raphaele Renard-Penna,
Eva Comperat,
Pierre Conort,
Marc-Olivier Bitker,
Emmanuel Chartier-Kastler,
Francois Richard,
Jocelyne Troccaz
Abstract:
Objective: Map** of transrectal ultrasonographic (TRUS) prostate biopsies is of fundamental importance for either diagnostic purposes or the management and treatment of prostate cancer, but the localization of the cores seems inaccurate. Our objective was to evaluate the capacities of an operator to plan transrectal prostate biopsies under 2-dimensional TRUS guidance using a registration algor…
▽ More
Objective: Map** of transrectal ultrasonographic (TRUS) prostate biopsies is of fundamental importance for either diagnostic purposes or the management and treatment of prostate cancer, but the localization of the cores seems inaccurate. Our objective was to evaluate the capacities of an operator to plan transrectal prostate biopsies under 2-dimensional TRUS guidance using a registration algorithm to represent the localization of biopsies in a reference 3-dimensional ultrasonographic volume.
Methods: Thirty-two patients underwent a series of 12 prostate biopsies under local anesthesia performed by 1 operator using a TRUS probe combined with specific third-party software to verify that the biopsies were indeed conducted within the planned targets. RESULTS: The operator reached 71% of the planned targets with substantial variability that depended on their localization (100% success rate for targets in the middle and right parasagittal parts versus 53% for targets in the left lateral base). Feedback from this system after each series of biopsies enabled the operator to significantly improve his dexterity over the course of time (first 16 patients: median score, 7 of 10 and cumulated median biopsy length in targets of 90 mm; last 16 patients, median score, 9 of 10 and a cumulated median length of 121 mm; P = .046).
Conclusions: In addition to being a useful tool to improve the distribution of prostate biopsies, the potential of this system is above all the preparation of a detailed "map" of each patient showing biopsy zones without substantial changes in routine clinical practices.
△ Less
Submitted 30 March, 2009;
originally announced March 2009.
-
Medical image computing and computer-aided medical interventions applied to soft tissues. Work in progress in urology
Authors:
Jocelyne Troccaz,
Michael Baumann,
Peter Berkelman,
Philippe Cinquin,
Vincent Daanen,
Antoine Leroy,
Maud Marchal,
Yohan Payan,
Emmanuel Promayon,
Sandrine Voros,
Stéphane Bart,
Michel Bolla,
Emmanuel Chartier-Kastler,
Jean-Luc Descotes,
Andrée Dusserre,
Jean-Yves Giraud,
Jean-Alexandre Long,
Ronan Moalic,
Pierre Mozer
Abstract:
Until recently, Computer-Aided Medical Interventions (CAMI) and Medical Robotics have focused on rigid and non deformable anatomical structures. Nowadays, special attention is paid to soft tissues, raising complex issues due to their mobility and deformation. Mini-invasive digestive surgery was probably one of the first fields where soft tissues were handled through the development of simulators…
▽ More
Until recently, Computer-Aided Medical Interventions (CAMI) and Medical Robotics have focused on rigid and non deformable anatomical structures. Nowadays, special attention is paid to soft tissues, raising complex issues due to their mobility and deformation. Mini-invasive digestive surgery was probably one of the first fields where soft tissues were handled through the development of simulators, tracking of anatomical structures and specific assistance robots. However, other clinical domains, for instance urology, are concerned. Indeed, laparoscopic surgery, new tumour destruction techniques (e.g. HIFU, radiofrequency, or cryoablation), increasingly early detection of cancer, and use of interventional and diagnostic imaging modalities, recently opened new challenges to the urologist and scientists involved in CAMI. This resulted in the last five years in a very significant increase of research and developments of computer-aided urology systems. In this paper, we propose a description of the main problems related to computer-aided diagnostic and therapy of soft tissues and give a survey of the different types of assistance offered to the urologist: robotization, image fusion, surgical navigation. Both research projects and operational industrial systems are discussed.
△ Less
Submitted 13 December, 2007;
originally announced December 2007.
-
Weak decays of 4He-Lambda
Authors:
J. D. Parker,
M. J. Athanas,
P. D. Barnes,
S. Bart,
B. Bassalleck,
R. Chrien,
G. Diebold,
G. B. Franklin,
K. Johnston,
P. Pile,
B. Quinn,
F. Rozon,
R. Sawafta,
R. A. Schumacher,
R. Stearns,
I. Sukaton,
R. Sutter,
J. J. Szymanski,
V. J. Zeps
Abstract:
We measured the lifetime and the mesonic and non-mesonic decay rates of the 4He-Lambda hypernucleus. The hypernuclei were created using a 750 MeV/c momentum K- beam on a liquid 4He target by the reaction 4He(K-,pi-)4He-Lambda. The 4He-Lambda lifetime was directly measured using protons from Lambda p -> n p non-mesonic decay (also referred to as proton-stimulated decay) and was found to have a va…
▽ More
We measured the lifetime and the mesonic and non-mesonic decay rates of the 4He-Lambda hypernucleus. The hypernuclei were created using a 750 MeV/c momentum K- beam on a liquid 4He target by the reaction 4He(K-,pi-)4He-Lambda. The 4He-Lambda lifetime was directly measured using protons from Lambda p -> n p non-mesonic decay (also referred to as proton-stimulated decay) and was found to have a value of tau = 245 +/- 24 ps. The mesonic decay rates were determined from the observed numbers of pi-'s and pi0's as Gamma_pi-/Gamma_tot = 0.270 +/- 0.024 and Gamma_pi0/Gamma_tot = 0.564 +/- 0.036, respectively, and the values of the proton- and neutron-stimulated decay rates were extracted as Gamma_p/Gamma_tot = 0.169 +/- 0.019 and Gamma_n/Gamma_tot <= 0.032 (95% CL), respectively. The effects of final-state interactions and possible 3-body Lambda N N decay contributions were studied in the context of a simple model of nucleon-stimulated decay. Nucleon-nucleon coincidence events were observed and were used in the determination of the non-mesonic branching fractions. The implications of the results of this analysis were considered for the empirical Delta I = 1/2 rule and the decay rates of the 4H-Lambda hypernucleus.
△ Less
Submitted 13 September, 2007; v1 submitted 23 May, 2007;
originally announced May 2007.
-
K$^+$-nucleus quasielastic scattering
Authors:
C. M. Kormanyos,
R. J. Peterson,
J. R. Shepard,
J. E. Wise,
S. Bart,
R. E. Chrien,
L. Lee,
B. L. Clausen,
J. Piekarewicz,
M. B. Barakat,
R. A. Michael,
T. Kishimoto
Abstract:
K$^+$--nucleus quasielastic cross sections measured for a laboratory kaon beam momentum of 705 MeV/$c$ are presented for 3--momentum transfers of 300 and 500 MeV/$c$. The measured differential cross sections for C, Ca and Pb at 500 MeV/$c$ are used to deduce the effective number of nucleons participating in the scattering, which are compared with estimates based on the eikonal approximation. The…
▽ More
K$^+$--nucleus quasielastic cross sections measured for a laboratory kaon beam momentum of 705 MeV/$c$ are presented for 3--momentum transfers of 300 and 500 MeV/$c$. The measured differential cross sections for C, Ca and Pb at 500 MeV/$c$ are used to deduce the effective number of nucleons participating in the scattering, which are compared with estimates based on the eikonal approximation. The long mean free path expected for K$^+$ mesons in nuclei is found. Double differential cross sections for C and Ca are compared to relativistic nuclear structure calculations.
△ Less
Submitted 30 July, 1993;
originally announced July 1993.