Fermilab Booster Beam Emittances from Quadrupole Modes Measured by BPMs
Authors:
C. Y. Tan,
M. Balcewicz
Abstract:
The measurement of beam emittances by extracting the quadrupole mode signal from a 4 plate beam position monitor (BPM) was published at least 40 years ago. Unfortunately, in practice, this method suffers from poor signal to noise ratio and requires a lot of tuning to extract out the emittances. In this paper, an improved method where multiple BPMs are used together with better mathematical analysi…
▽ More
The measurement of beam emittances by extracting the quadrupole mode signal from a 4 plate beam position monitor (BPM) was published at least 40 years ago. Unfortunately, in practice, this method suffers from poor signal to noise ratio and requires a lot of tuning to extract out the emittances. In this paper, an improved method where multiple BPMs are used together with better mathematical analysis is described. The BPM derived emittances are then compared with those measured by the Ion Profile Monitor (IPM). Surprisingly, the BPM measured emittances behave very well and are more realistic than those measured by the IPM.
△ Less
Submitted 21 June, 2024;
originally announced June 2024.
-
Observation of a Synchro-betatron Instability in Fermilab Booster
Authors:
M. Balcewicz,
J. Eldred
Abstract:
In preparation for PIP-II, there has been interest in running the Fermilab Booster at a higher current more indicative of the PIP-II era operation. In July 2023, an experiment was performed to study collective instabilities over the transition crossing at the Fermilab Booster. Over the transition crossing, the synchrotron tune becomes small and synchro-betatron instabilities become possible. Durin…
▽ More
In preparation for PIP-II, there has been interest in running the Fermilab Booster at a higher current more indicative of the PIP-II era operation. In July 2023, an experiment was performed to study collective instabilities over the transition crossing at the Fermilab Booster. Over the transition crossing, the synchrotron tune becomes small and synchro-betatron instabilities become possible. During the experiment, an intensity threshold was observed, above which a dipole instability with losses concentrated in the tail of the bunch. These losses are consistent with the Convective Instability.
△ Less
Submitted 20 June, 2024;
originally announced June 2024.
-
Reconstruction of Storage Ring 's Linear Optics with Bayesian Inference
Authors:
Yue Hao,
Yongjun Li,
Michael Balcewicz,
Leo Neufcourt,
Weixing Cheng
Abstract:
A novel approach of accurately reconstructing storage ring's linear optics from turn-by-turn (TbT) data containing measurement error is introduced. This approach adopts a Bayesian inference based on the Markov Chain Monte-Carlo (MCMC) algorithm, which is widely used in data-driven discoveries. By assuming a preset accelerator model with unknown parameters, the inference process yields the their po…
▽ More
A novel approach of accurately reconstructing storage ring's linear optics from turn-by-turn (TbT) data containing measurement error is introduced. This approach adopts a Bayesian inference based on the Markov Chain Monte-Carlo (MCMC) algorithm, which is widely used in data-driven discoveries. By assuming a preset accelerator model with unknown parameters, the inference process yields the their posterior distribution. This approach is demonstrated by inferring the linear optics Twiss parameters and their measurement uncertainties using a set of data measured at the National Synchrotron Light Source-II (NSLS-II) storage ring. Some critical effects, such as radiation dam** rate, decoherence due to nonlinearity and chromaticity can also be included in the model and inferred. These effects are usually ignored in existing approaches. One advantage of the MCMC based Bayesian inference is that it doesn't require a large data pool, thus a complete optics reconstruction can be accomplished from a limited number of turns in a single data snapshot, before a significant machine drift can happen. The precise reconstruction of the parameter in accelerator model with the uncertainties is crucial prior information for applying the them to improve machine performance.
△ Less
Submitted 27 June, 2019; v1 submitted 28 February, 2019;
originally announced February 2019.