-
On Fabry-Pérot etalon-based instruments. IV. Analytical formulation of telecentric etalons
Authors:
F. J. Bailén,
D. Orozco Suárez,
J. C. del Toro Iniesta
Abstract:
Fabry-Pérot etalons illuminated with collimated beams have been characterized analytically in detail since their invention. Meanwhile, most of the features of etalons located in telecentric planes have been studied only numerically, despite the wide use of this configuration in astrophysical instrumentation over decades. In this work we present analytical expressions for the transmitted electric f…
▽ More
Fabry-Pérot etalons illuminated with collimated beams have been characterized analytically in detail since their invention. Meanwhile, most of the features of etalons located in telecentric planes have been studied only numerically, despite the wide use of this configuration in astrophysical instrumentation over decades. In this work we present analytical expressions for the transmitted electric field and its derivatives that are valid for etalons placed in slow telecentric beams, like the ones commonly employed in solar instruments. We use the derivatives to infer the sensitivity of the electric field to variations in the optical thickness for different reflectivities and apertures of the incident beam and we compare them to the collimated case. This allows us to estimate the wavefront degradation produced by roughness errors on the surfaces of the Fabry-Pérot and to establish the maximum allowed RMS value of the cavity irregularities across the footprint of the incident beam on the etalon that ensures diffraction-limited performance. We also evaluate the wavefront degradation intrinsic to these mounts, which is produced only by the finite aperture of the beam and that must be added to the one produced by defects. Finally, we discuss the differences in performance of telecentric and collimated etalon-based instruments and we generalize our formulation to anisotropic etalons.
△ Less
Submitted 12 May, 2022;
originally announced May 2022.
-
On Fabry-Pérot Etalon-based Instruments. III. Instrument applications
Authors:
F. J. Bailén,
D. Orozco Suárez,
J. C. del Toro Iniesta
Abstract:
The spectral, imaging, and polarimetric behavior of Fabry-Pérot etalons have an influence on imaging vector magnetograph instruments based on these devices. The impact depends, among others, on the optical configuration (collimated or telecentric), on the relative position of the etalon with respect to the polarimeter, on the type of etalon (air-gapped or crystalline), and even on the polarimetric…
▽ More
The spectral, imaging, and polarimetric behavior of Fabry-Pérot etalons have an influence on imaging vector magnetograph instruments based on these devices. The impact depends, among others, on the optical configuration (collimated or telecentric), on the relative position of the etalon with respect to the polarimeter, on the type of etalon (air-gapped or crystalline), and even on the polarimetric technique to be used (single-beam or dual-beam). In this paper we evaluate the artificial line-of-sight velocities and magnetic field strengths that arise in etalon-based instruments attending to the mentioned factors. We differentiate between signals that are implicit to telecentric mounts due to the wavelength dependence of the point-spread function and those emerging in both collimated and telecentric setups from the polarimetric response of birefringent etalons. For the anisotropic case we consider two possible locations of the etalon, between the modulator and the analyzer or after it, and we include the effect on different channels when dual-beam polarimetry is employed. We also evaluate the impact of the loss of symmetry produced in telecentric mounts due to imperfections in the illumination and/or to a tilt of the etalon relative to the incident beam.
△ Less
Submitted 3 February, 2020;
originally announced February 2020.
-
On Fabry Pérot Etalon based Instruments. II. The Anisotropic (Birefringent) Case
Authors:
F. J. Bailén,
D. Orozco Suárez,
J. C. del Toro Iniesta
Abstract:
Crystalline etalons present several advantages with respect to other types of filtergraphs when employed in magnetographs. Specially that they can be tuned by only applying electric fields. However, anisotropic crystalline etalons can also introduce undesired birefringent effects that corrupt the polarization of the incoming light. In particular, uniaxial Fabry-Pérots, such as LiNbO3 etalons, are…
▽ More
Crystalline etalons present several advantages with respect to other types of filtergraphs when employed in magnetographs. Specially that they can be tuned by only applying electric fields. However, anisotropic crystalline etalons can also introduce undesired birefringent effects that corrupt the polarization of the incoming light. In particular, uniaxial Fabry-Pérots, such as LiNbO3 etalons, are birefringent when illuminated with an oblique beam. The farther the incidence from the normal, the larger the induced retardance between the two orthogonal polarization states. The application of high-voltages, as well as fabrication defects, can also change the direction of the optical axis of the crystal, introducing birefringence even at normal illumination. Here we obtain analytical expressions for the induced retardance and for the Mueller matrix of uniaxial etalons located in both collimated and telecentric configurations. We also evaluate the polarimetric behavior of Z-cut crystalline etalons with the incident angle, with the orientation of the optical axis, and with the f-number of the incident beam for the telecentric case. We study artificial signals produced in the output Stokes vector in the two configurations. Last, we discuss the polarimetric dependence of the imaging response of the etalon for both collimated and telecentric setups.
△ Less
Submitted 25 June, 2019;
originally announced June 2019.
-
On Fabry Pérot Etalon based Instruments. I. The Isotropic Case
Authors:
F. J. Bailén,
D. Orozco Suárez,
J. C. del Toro Iniesta
Abstract:
Here we assess the spectral and imaging properties of Fabry Pérot etalons when located in solar magnetographs. We discuss the chosen configuration (collimated or telecentric) for both ideal and real cases. For the real cases, we focus on the effects caused by the polychromatic illumination of the filter by the irregularities in the optical thickness of the etalon and by deviations from the ideal i…
▽ More
Here we assess the spectral and imaging properties of Fabry Pérot etalons when located in solar magnetographs. We discuss the chosen configuration (collimated or telecentric) for both ideal and real cases. For the real cases, we focus on the effects caused by the polychromatic illumination of the filter by the irregularities in the optical thickness of the etalon and by deviations from the ideal illumination in both setups. We first review the general properties of Fabry Pérots and we then address the different sources of degradation of the spectral transmission profile. We review and extend the general treatment of defects followed by different authors. We discuss the differences between the point spread functions (PSFs) of the collimated and telecentric configurations for both monochromatic and (real) quasi-monochromatic illumination of the etalon. The PSF corresponding to collimated mounts is shown to have a better performance, although it varies from point to point due to an apodization of the image inherent to this configuration. This is in contrast to the (perfect) telecentric case, where the PSF remains constant but produces artificial velocities and magnetic field signals because of its strong spectral dependence. We find that the unavoidable presence of imperfections in the telecentrism produces a decrease of flux of photons and a shift, a broadening and a loss of symmetrization of both the spectral and PSF profiles over the field of view, thus compromising their advantages over the collimated configuration. We evaluate these effects for different apertures of the incident beam.
△ Less
Submitted 15 March, 2019;
originally announced March 2019.
-
Effective mass theory for the anisotropic exciton in 2D crystals: Application to phosphorene
Authors:
Elsa Prada,
J. V. Alvarez,
K. L. Narasimha-Acharya,
F. J. Bailen,
J. J. Palacios
Abstract:
We present a theoretical study of the exciton binding energy for anisotropic two-dimensional crystals. We obtain analytical expressions from variational wave functions in different limits of the screening length to exciton size ratio and compare them with numerical solutions, both variational and exact. As an example, we apply these results to phosphorene, a monolayer of black phosphorous. Aided b…
▽ More
We present a theoretical study of the exciton binding energy for anisotropic two-dimensional crystals. We obtain analytical expressions from variational wave functions in different limits of the screening length to exciton size ratio and compare them with numerical solutions, both variational and exact. As an example, we apply these results to phosphorene, a monolayer of black phosphorous. Aided by density functional theory calculations for the evaluation of the two-dimensional polarizability, our analytical solution for the exciton binding energy gives a result which is very close to the numerical ones and, in turn, is comparable to the experimental value, as recently reported.
△ Less
Submitted 14 March, 2016; v1 submitted 9 April, 2015;
originally announced April 2015.