-
$β$-nuclear-recoil correlation from $^6$He decay in a laser trap
Authors:
P. Müller,
Y. Bagdasarova,
R. Hong,
A. Leredde,
K. G. Bailey,
X. Fléchard,
A. García,
B. Graner,
A. Knecht,
O. Naviliat-Cuncic,
T. P. O'Connor,
M. G. Sternberg,
D. W. Storm,
H. E. Swanson,
F. Wauters,
D. W. Zumwalt
Abstract:
We report the first precise measurement of a $β$-recoil correlation from a radioactive noble gas ($^6{\rm He}$) confined via a magneto-optical trap. The measurement is motivated by the search for exotic tensor-type contributions to the charged weak current. Interpreted as tensor currents with right-handed neutrinos, the measurements yield: $|C_T/C_A|^2\le 0.022$ (90\% C.L.). On the other hand, for…
▽ More
We report the first precise measurement of a $β$-recoil correlation from a radioactive noble gas ($^6{\rm He}$) confined via a magneto-optical trap. The measurement is motivated by the search for exotic tensor-type contributions to the charged weak current. Interpreted as tensor currents with right-handed neutrinos, the measurements yield: $|C_T/C_A|^2\le 0.022$ (90\% C.L.). On the other hand, for left-handed neutrinos the limits are $0.007< C_T/C_A <0.111$~(90\%\ C.L.). The sensitivity of the present measurement is mainly limited by experimental uncertainties in determining the time response properties and the distance between the atom cloud and the micro-channel plate used for recoil ion detection.
△ Less
Submitted 1 June, 2022;
originally announced June 2022.
-
Improved limits on Fierz Interference using asymmetry measurements from the UCNA experiment
Authors:
Xuan Sun,
E. Adamek,
B. Allgeier,
Y. Bagdasarova,
D. B. Berguno,
M. Blatnik,
T. J. Bowles,
L. J. Broussard,
M. A. -P. Brown,
R. Carr,
S. Clayton,
C. Cude-Woods,
S. Currie,
E. B. Dees,
X. Ding,
B. W. Filippone,
A. García,
P. Geltenbort,
S. Hasan,
K. P. Hickerson,
J. Hoagland,
R. Hong,
A. T. Holley,
T. M. Ito,
A. Knecht
, et al. (34 additional authors not shown)
Abstract:
The Ultracold Neutron Asymmetry (UCNA) experiment was designed to measure the $β$-decay asymmetry parameter, $A_0$, for free neutron decay. In the experiment, polarized ultracold neutrons are transported into a decay trap, and their $β$-decay electrons are detected with $\approx 4π$ acceptance into two detector packages which provide position and energy reconstruction. The experiment also has sens…
▽ More
The Ultracold Neutron Asymmetry (UCNA) experiment was designed to measure the $β$-decay asymmetry parameter, $A_0$, for free neutron decay. In the experiment, polarized ultracold neutrons are transported into a decay trap, and their $β$-decay electrons are detected with $\approx 4π$ acceptance into two detector packages which provide position and energy reconstruction. The experiment also has sensitivity to $b_{n}$, the Fierz interference term in the neutron $β$-decay rate. In this work, we determine $b_{n}$ from the energy dependence of $A_0$ using the data taken during the UCNA 2011-2013 run. In addition, we present the same type of analysis using the earlier 2010 $A$ dataset. Motivated by improved statistics and comparable systematic errors compared to the 2010 data-taking run, we present a new $b_{n}$ measurement using the weighted average of our asymmetry dataset fits, to obtain $b_{n} = 0.066 \pm 0.041_{\text{stat}} \pm 0.024_{\text{syst}}$ which corresponds to a limit of $-0.012 < b_{n} < 0.144$ at the 90% confidence level.
△ Less
Submitted 13 November, 2019;
originally announced November 2019.
-
Final results for the neutron $β$-asymmetry parameter $A_0$ from the UCNA experiment
Authors:
B. Plaster,
E. Adamek,
B. Allgeier,
J. Anaya,
H. O. Back,
Y. Bagdasarova,
D. B. Berguno,
M. Blatnik,
J. G. Boissevain,
T. J. Bowles,
L. J. Broussard,
M. A. -P. Brown,
R. Carr,
D. J. Clark,
S. Clayton,
C. Cude-Woods,
S. Currie,
E. B. Dees,
X. Ding,
S. Du,
B. W. Filippone,
A. Garcia,
P. Geltenbort,
S. Hasan,
A. Hawari
, et al. (69 additional authors not shown)
Abstract:
The UCNA experiment was designed to measure the neutron $β$-asymmetry parameter $A_0$ using polarized ultracold neutrons (UCN). UCN produced via downscattering in solid deuterium were polarized via transport through a 7 T magnetic field, and then directed to a 1 T solenoidal electron spectrometer, where the decay electrons were detected in electron detector packages located on the two ends of the…
▽ More
The UCNA experiment was designed to measure the neutron $β$-asymmetry parameter $A_0$ using polarized ultracold neutrons (UCN). UCN produced via downscattering in solid deuterium were polarized via transport through a 7 T magnetic field, and then directed to a 1 T solenoidal electron spectrometer, where the decay electrons were detected in electron detector packages located on the two ends of the spectrometer. A value for $A_0$ was then extracted from the asymmetry in the numbers of counts in the two detector packages. We summarize all of the results from the UCNA experiment, obtained during run periods in 2007, 2008--2009, 2010, and 2011--2013, which ultimately culminated in a 0.67\% precision result for $A_0$.
△ Less
Submitted 10 April, 2019;
originally announced April 2019.
-
First direct constraints on Fierz interference in free neutron $β$ decay
Authors:
K. P. Hickerson,
X. Sun,
Y. Bagdasarova,
D. Bravo-Berguño,
L. J. Broussard,
M. A. -P. Brown,
R. Carr,
S. Currie,
X. Ding,
B. W. Filippone,
A. García,
P. Geltenbort,
J. Hoagland,
A. T. Holley,
R. Hong,
T. M. Ito,
A. Knecht,
C. -Y. Liu,
J. L. Liu,
M. Makela,
R. R. Mammei,
J. W. Martin,
D. Melconian,
M. P. Mendenhall,
S. D. Moore
, et al. (18 additional authors not shown)
Abstract:
Precision measurements of free neutron $β$-decay have been used to precisely constrain our understanding of the weak interaction. However the neutron Fierz interference term $b_n$, which is particularly sensitive to Beyond-Standard-Model tensor currents at the TeV scale, has thus far eluded measurement. Here we report the first direct constraints on this term, finding…
▽ More
Precision measurements of free neutron $β$-decay have been used to precisely constrain our understanding of the weak interaction. However the neutron Fierz interference term $b_n$, which is particularly sensitive to Beyond-Standard-Model tensor currents at the TeV scale, has thus far eluded measurement. Here we report the first direct constraints on this term, finding $b_n = 0.067 \pm 0.005_{\text{stat}} {}^{+0.090}_{- 0.061}{}_{\text{sys}}$, consistent with the Standard Model. The uncertainty is dominated by absolute energy reconstruction and the linearity of the beta spectrometer energy response.
△ Less
Submitted 8 July, 2017; v1 submitted 3 July, 2017;
originally announced July 2017.
-
Charge-state distribution of Li ions from the $β$ decay of laser-trapped $^{6}$He atoms
Authors:
Ran Hong,
Arnaud Leredde,
Yelena Bagdasarova,
Xavier Fléchard,
Alejandro García,
Andreas Knecht,
Peter Müller,
Oscar Naviliat-Cuncic,
Joben Pedersen,
Eric Smith,
Matthew Sternberg,
Derek W. Storm,
Herbert. Erik Swanson,
Frederik Wauters,
David Zumwalt
Abstract:
Background: The accurate determination of atomic final states following nuclear $β$ decay plays an important role in many experiments. In particular, the charge state distributions of ions following nuclear $β$ decay are important for determinations of the $β-ν$ angular correlation with improved precision. Purpose: Our measurement aims at providing benchmarks to test theoretical calculations. Meth…
▽ More
Background: The accurate determination of atomic final states following nuclear $β$ decay plays an important role in many experiments. In particular, the charge state distributions of ions following nuclear $β$ decay are important for determinations of the $β-ν$ angular correlation with improved precision. Purpose: Our measurement aims at providing benchmarks to test theoretical calculations. Method: The kinematics of Li$^{n+}$ ions produced following the $β$ decay of $^6{\rm He}$ within an electric field were measured using $^6{\rm He}$ atoms in the metastable $(1s2s,~{^3S_1})$ and in the $(1s2p,~{^3P_2})$ states confined by a magneto-optical trap. The electron shake-off probabilities were deduced including their dependence on ion energy. Results: We find significant discrepancies on the fractions of Li ions in the different charge states with respect to a recent calculation and discuss a plausible explanation. We also point out that there is no explanation for a large discrepancy between the same calculation and a previous measurement of the Li-ion energy dependence of the charge distribution from decays of the electronic ground state.
△ Less
Submitted 19 December, 2017; v1 submitted 21 March, 2017;
originally announced March 2017.
-
High accuracy position response calibration method for a micro-channel plate ion detector
Authors:
Ran Hong,
Arnaud Leredde,
Yelena Bagdasarova,
Xavier Flechard,
Alejandro Garcia,
Peter Mueller,
Andreas Knecht,
Etienne Lienard,
Michael Kossin,
Matthew G. Sternberg,
H. E. Swanson,
David W. Zumwalt
Abstract:
We have developed a position response calibration method for a micro-channel plate (MCP) detector with a delay-line anode position readout scheme. Using an {\em in situ} calibration mask, an accuracy of 8~$μ$m and a resolution of 85~$μ$m (FWHM) have been achieved for MeV-scale $α$ particles and ions with energies of $\sim$10~keV. At this level of accuracy, the difference between the MCP position r…
▽ More
We have developed a position response calibration method for a micro-channel plate (MCP) detector with a delay-line anode position readout scheme. Using an {\em in situ} calibration mask, an accuracy of 8~$μ$m and a resolution of 85~$μ$m (FWHM) have been achieved for MeV-scale $α$ particles and ions with energies of $\sim$10~keV. At this level of accuracy, the difference between the MCP position responses to high-energy $α$ particles and low-energy ions is significant. The improved performance of the MCP detector can find applications in many fields of AMO and nuclear physics. In our case, it helps reducing systematic uncertainties in a high-precision nuclear $β$-decay experiment.
△ Less
Submitted 8 September, 2016; v1 submitted 27 May, 2016;
originally announced May 2016.
-
Measurements of ultracold neutron upscattering and absorption in polyethylene and vanadium
Authors:
E. I. Sharapov,
C. L. Morris,
M. Makela,
A. Saunders,
Evan R. Adamek,
Yelena Bagdasarova,
L. J. Broussard,
C. B. Cude-Woods,
Deon E Fellers,
Peter Geltenbort,
S. I. Hasan,
K. P. Hickerson,
G. Hogan,
A. T. Holley,
Chen-Yu Liu,
M. P. Mendenhall,
J. Ortiz,
R. W. Pattie Jr.,
D. G. Phillips,
J. Ramsey,
D. J. Salvat,
S. J. Seestrom,
E. Shaw,
Sky Sjue,
W. E. Sondheim
, et al. (5 additional authors not shown)
Abstract:
The study of neutron cross sections for elements used as efficient ``absorbers'' of ultracold neutrons (UCN) is crucial for many precision experiments in nuclear and particle physics, cosmology and gravity. In this context, ``absorption'' includes both the capture and upscattering of neutrons to the energies above the UCN energy region. The available data, especially for hydrogen, do not agree bet…
▽ More
The study of neutron cross sections for elements used as efficient ``absorbers'' of ultracold neutrons (UCN) is crucial for many precision experiments in nuclear and particle physics, cosmology and gravity. In this context, ``absorption'' includes both the capture and upscattering of neutrons to the energies above the UCN energy region. The available data, especially for hydrogen, do not agree between themselves or with the theory. In this report we describe measurements performed at the Los Alamos National Laboratory UCN facility of the UCN upscattering cross sections for vanadium and for hydrogen in CH$_2$ using simultaneous measurements of the radiative capture cross sections for these elements. We measured $σ_{up}=1972\pm130$ b for hydrogen in CH$_2$, which is below theoretical expectations, and $σ_{up} < 25\pm9$ b for vanadium, in agreement with the expectation for the neutron heating by thermal excitations in solids.
△ Less
Submitted 5 June, 2013;
originally announced June 2013.
-
Precision Measurement of the Neutron Beta-Decay Asymmetry
Authors:
M. P. Mendenhall,
R. W. Pattie Jr,
Y. Bagdasarova,
D. B. Berguno,
L. J. Broussard,
R. Carr,
S. Currie,
X. Ding,
B. W. Filippone,
A. García,
P. Geltenbort,
K. P. Hickerson,
J. Hoagland,
A. T. Holley,
R. Hong,
T. M. Ito,
A. Knecht,
C. -Y. Liu,
J. L. Liu,
M. Makela,
R. R. Mammei,
J. W. Martin,
D. Melconian,
S. D. Moore,
C. L. Morris
, et al. (16 additional authors not shown)
Abstract:
A new measurement of the neutron $β$-decay asymmetry $A_0$ has been carried out by the UCNA collaboration using polarized ultracold neutrons (UCN) from the solid deuterium UCN source at the Los Alamos Neutron Science Center (LANSCE). Improvements in the experiment have led to reductions in both statistical and systematic uncertainties leading to $A_0 = -0.11954(55)_{\rm stat.}(98)_{\rm syst.}$, co…
▽ More
A new measurement of the neutron $β$-decay asymmetry $A_0$ has been carried out by the UCNA collaboration using polarized ultracold neutrons (UCN) from the solid deuterium UCN source at the Los Alamos Neutron Science Center (LANSCE). Improvements in the experiment have led to reductions in both statistical and systematic uncertainties leading to $A_0 = -0.11954(55)_{\rm stat.}(98)_{\rm syst.}$, corresponding to the ratio of axial-vector to vector coupling $λ\equiv g_A/g_V = -1.2756(30)$.
△ Less
Submitted 19 February, 2013; v1 submitted 25 October, 2012;
originally announced October 2012.
-
Weak Interaction Studies with 6He
Authors:
A. Knecht,
Z. T. Alexander,
Y. Bagdasarova,
T. M. Cope,
B. G. Delbridge,
X. Flechard,
A. Garcia,
R. Hong,
E. Lienard,
P. Mueller,
O. Naviliat-Cuncic,
A. S. C. Palmer,
R. G. H. Robertson,
D. W. Storm,
H. E. Swanson,
S. Utsuno,
F. Wauters,
W. Williams,
C. Wrede,
D. W. Zumwalt
Abstract:
The 6He nucleus is an ideal candidate to study the weak interaction. To this end we have built a high-intensity source of 6He delivering ~10^10 atoms/s to experiments. Taking full advantage of that available intensity we have performed a high-precision measurement of the 6He half-life that directly probes the axial part of the nuclear Hamiltonian. Currently, we are preparing a measurement of the b…
▽ More
The 6He nucleus is an ideal candidate to study the weak interaction. To this end we have built a high-intensity source of 6He delivering ~10^10 atoms/s to experiments. Taking full advantage of that available intensity we have performed a high-precision measurement of the 6He half-life that directly probes the axial part of the nuclear Hamiltonian. Currently, we are preparing a measurement of the beta-neutrino angular correlation in 6He beta decay that will allow to search for new physics beyond the Standard Model in the form of tensor currents.
△ Less
Submitted 19 October, 2012; v1 submitted 31 August, 2012;
originally announced August 2012.
-
From x-ray telescopes to neutron scattering: using axisymmetric mirrors to focus a neutron beam
Authors:
B. Khaykovich,
M. V. Gubarev,
Y. Bagdasarova,
B. D. Ramsey,
D. E. Moncton
Abstract:
We demonstrate neutron beam focusing by axisymmetric mirror systems based on a pair of mirrors consisting of a confocal ellipsoid and hyperboloid. Such a system, known as a Wolter mirror configuration, is commonly used in x-ray telescopes. The axisymmetric Wolter geometry allows nesting of several mirror pairs to increase collection efficiency. We have implemented a system containing four nested N…
▽ More
We demonstrate neutron beam focusing by axisymmetric mirror systems based on a pair of mirrors consisting of a confocal ellipsoid and hyperboloid. Such a system, known as a Wolter mirror configuration, is commonly used in x-ray telescopes. The axisymmetric Wolter geometry allows nesting of several mirror pairs to increase collection efficiency. We have implemented a system containing four nested Ni mirror pairs, which was tested by focusing a polychromatic neutron beam at the MIT Reactor. In addition, we have carried out extensive ray-tracing simulations of the mirrors and their performance in different situations. The major advantages of the Wolter mirrors are nesting for large angular collection, and aberration-free performance. We discuss how these advantages can be utilized to benefit various neutron scattering methods, such as imaging, SANS, and time-of-flight spectroscopy.
△ Less
Submitted 13 April, 2012;
originally announced April 2012.