-
Total-Body Parametric Imaging Using Relative Patlak Plot
Authors:
Siqi Li,
Yasser G. Abdelhafez,
Lorenzo Nardo,
Simon R. Cherry,
Ramsey D. Badawi,
Guobao Wang
Abstract:
Standard Patlak plot is widely used to describe FDG kinetics for dynamic PET imaging. Whole-body Patlak parametric imaging remains constrained due to the need for a full-time input function. Here, we demonstrate the Relative Patlak (RP) plot, which eliminates the need for the early-time input function, for total-body parametric imaging and its application to clinical 20-min "static" scans. We demo…
▽ More
Standard Patlak plot is widely used to describe FDG kinetics for dynamic PET imaging. Whole-body Patlak parametric imaging remains constrained due to the need for a full-time input function. Here, we demonstrate the Relative Patlak (RP) plot, which eliminates the need for the early-time input function, for total-body parametric imaging and its application to clinical 20-min "static" scans. We demonstrated that the RP intercept b' is equivalent to a ratio of standardized uptake value relative to the blood, while the RP slope Ki' is equal to the standard Patlak Ki multiplied by a global scaling factor for each subject. One challenge in applying RP to a short scan duration (20 min) is the high noise in parametric images. We applied a deep kernel method for noise reduction. Using the standard Patlak plot as the reference, the RP method was evaluated for lesion quantification, lesion-to-background contrast, and myocardial visualization in total-body parametric imaging with uEXPLORER in 22 human subjects who underwent a 1-h dynamic 18F-FDG scan. The RP method was also applied to the dynamic data regenerated from a clinical standard 20-min "static" scan either at 1-h or 2-h post-injection for two cancer patients. We demonstrated that it is feasible to obtain high-quality parametric images from 20-min dynamic scans using the RP plot with a self-supervised deep-kernel noise reduction strategy. The RP Ki' highly correlated with Ki in lesions and major organs, demonstrating its quantitative potential across subjects. Compared to conventional SUVs, the Ki' images significantly improved lesion contrast and enabled visualization of the myocardium for potential cardiac assessment. The application of RP parametric imaging to two "static" scans also showed similar benefits. Total-body PET with the RP plot is feasible to generate parametric images from the dynamic data of a 20-min clinical "static" scan.
△ Less
Submitted 14 June, 2024;
originally announced June 2024.
-
Dose-aware Diffusion Model for 3D Low-dose PET: Multi-institutional Validation with Reader Study and Real Low-dose Data
Authors:
Huidong Xie,
Weijie Gan,
Bo Zhou,
Ming-Kai Chen,
Michal Kulon,
Annemarie Boustani,
Benjamin A. Spencer,
Reimund Bayerlein,
Xiongchao Chen,
Qiong Liu,
Xueqi Guo,
Menghua Xia,
Yinchi Zhou,
Hui Liu,
Liang Guo,
Hongyu An,
Ulugbek S. Kamilov,
Hanzhong Wang,
Biao Li,
Axel Rominger,
Kuangyu Shi,
Ge Wang,
Ramsey D. Badawi,
Chi Liu
Abstract:
As PET imaging is accompanied by radiation exposure and potentially increased cancer risk, reducing radiation dose in PET scans without compromising the image quality is an important topic. Deep learning (DL) techniques have been investigated for low-dose PET imaging. However, existing models have often resulted in compromised image quality when achieving low-dose PET and have limited generalizabi…
▽ More
As PET imaging is accompanied by radiation exposure and potentially increased cancer risk, reducing radiation dose in PET scans without compromising the image quality is an important topic. Deep learning (DL) techniques have been investigated for low-dose PET imaging. However, existing models have often resulted in compromised image quality when achieving low-dose PET and have limited generalizability to different image noise-levels, acquisition protocols, patient populations, and hospitals. Recently, diffusion models have emerged as the new state-of-the-art generative model to generate high-quality samples and have demonstrated strong potential for medical imaging tasks. However, for low-dose PET imaging, existing diffusion models failed to generate consistent 3D reconstructions, unable to generalize across varying noise-levels, often produced visually-appealing but distorted image details, and produced images with biased tracer uptake. Here, we develop DDPET-3D, a dose-aware diffusion model for 3D low-dose PET imaging to address these challenges. Collected from 4 medical centers globally with different scanners and clinical protocols, we extensively evaluated the proposed model using a total of 9,783 18F-FDG studies (1,596 patients) with low-dose/low-count levels ranging from 1% to 50%. With a cross-center, cross-scanner validation, the proposed DDPET-3D demonstrated its potential to generalize to different low-dose levels, different scanners, and different clinical protocols. As confirmed with reader studies performed by nuclear medicine physicians, the proposed method produced superior denoised results that are comparable to or even better than the 100% full-count images as well as previous DL baselines. The presented results show the potential of achieving low-dose PET while maintaining image quality. Lastly, a group of real low-dose scans was also included for evaluation.
△ Less
Submitted 2 May, 2024;
originally announced May 2024.
-
Feasibility of PET-enabled dual-energy CT imaging: First physical phantom and patient results
Authors:
Yansong Zhu,
Siqi Li,
Zhaoheng Xie,
Edwin K. Leung,
Reimund Bayerlein,
Negar Omidvari,
Simon R. Cherry,
**yi Qi,
Ramsey D. Badawi,
Benjamin A. Spencer,
Guobao Wang
Abstract:
X-ray computed tomography (CT) in PET/CT is commonly operated with a single energy, resulting in a limitation of lacking tissue composition information. Dual-energy (DE) spectral CT enables material decomposition by using two different x-ray energies and may be combined with PET for improved multimodality imaging, but would either require hardware upgrade or increase radiation dose due to the adde…
▽ More
X-ray computed tomography (CT) in PET/CT is commonly operated with a single energy, resulting in a limitation of lacking tissue composition information. Dual-energy (DE) spectral CT enables material decomposition by using two different x-ray energies and may be combined with PET for improved multimodality imaging, but would either require hardware upgrade or increase radiation dose due to the added second x-ray CT scan. Recently proposed PET-enabled DECT method allows dual-energy spectral imaging using a conventional PET/CT scanner without the need for a second x-ray CT scan. A gamma-ray CT (gCT) image at 511 keV can be generated from the existing time-of-flight PET data with the maximum-likelihood attenuation and activity (MLAA) approach and is then combined with the low-energy x-ray CT image to form dual-energy spectral imaging. To improve the image quality of gCT, a kernel MLAA method was further proposed by incorporating x-ray CT as a priori information. The concept of this PET-enabled DECT has been validated using simulation studies, but not yet with 3D real data. In this work, we developed a general open-source implementation for gCT reconstruction from PET data and use this implementation for the first real data validation with both a physical phantom study and a human subject study on a uEXPLORER total-body PET/CT system. These results have demonstrated the feasibility of this method for spectral imaging and material decomposition.
△ Less
Submitted 11 April, 2024; v1 submitted 3 February, 2024;
originally announced February 2024.
-
Physics-Informed Neural Network for the Transient Diffusivity Equation in Reservoir Engineering
Authors:
Daniel Badawi,
Eduardo Gildin
Abstract:
Physics-Informed machine learning models have recently emerged with some interesting and unique features that can be applied to reservoir engineering. In particular, physics-informed neural networks (PINN) leverage the fact that neural networks are a type of universal function approximators that can embed the knowledge of any physical laws that govern a given data-set in the learning process, and…
▽ More
Physics-Informed machine learning models have recently emerged with some interesting and unique features that can be applied to reservoir engineering. In particular, physics-informed neural networks (PINN) leverage the fact that neural networks are a type of universal function approximators that can embed the knowledge of any physical laws that govern a given data-set in the learning process, and can be described by partial differential equations. The transient diffusivity equation is a fundamental equation in reservoir engineering and the general solution to this equation forms the basis for Pressure Transient Analysis (PTA). The diffusivity equation is derived by combining three physical principles, the continuity equation, Darcy's equation, and the equation of state for a slightly compressible liquid. Obtaining general solutions to this equation is imperative to understand flow regimes in porous media. Analytical solutions of the transient diffusivity equation are usually hard to obtain due to the stiff nature of the equation caused by the steep gradients of the pressure near the well. In this work we apply physics-informed neural networks to the one and two dimensional diffusivity equation and demonstrate that decomposing the space domain into very few subdomains can overcome the stiffness problem of the equation. Additionally, we demonstrate that the inverse capabilities of PINNs can estimate missing physics such as permeability and distance from sealing boundary similar to buildup tests without shutting in the well.
△ Less
Submitted 29 November, 2023; v1 submitted 29 September, 2023;
originally announced September 2023.
-
Supplemental Transmission Aided Attenuation Correction for Quantitative Cardiac PET/MR
Authors:
Mi-Ae Park,
Vlad G. Zaha,
Ramsey D. Badawi,
Spencer L. Bowen
Abstract:
Quantitative PET attenuation correction (AC) for combined cardiac PET/MR is a challenging problem. We propose and evaluate an AC approach that uses coincidences from a relatively weak and physically fixed sparse external source, in combination with that from the patient, to correct for PET attenuation based on physics principles alone. The low 30 ml volume of the source makes it easy to fill and p…
▽ More
Quantitative PET attenuation correction (AC) for combined cardiac PET/MR is a challenging problem. We propose and evaluate an AC approach that uses coincidences from a relatively weak and physically fixed sparse external source, in combination with that from the patient, to correct for PET attenuation based on physics principles alone. The low 30 ml volume of the source makes it easy to fill and place, and the method does not use prior image data or attenuation map assumptions. Our supplemental transmission aided maximum likelihood reconstruction of attenuation and activity (sTX-MLAA) algorithm contains an attenuation map update that maximizes the likelihood of terms representing coincidences originating from tracer in the patient and a weighted expression of counts segmented from the external source alone. Both external source and patient scatter and randoms are fully corrected. We evaluated performance of sTX-MLAA compared to reference standard CT-based AC with FDG PET/CT phantom studies; including modeling a patient with myocardial inflammation. Through an ROI analysis we measured less than 5% bias in activity concentrations for PET images generated with sTX-MLAA relative to CT-AC. PET background variability (from noise and sparse sampling) was substantially reduced with sTX-MLAA compared to using coincidences segmented from the transmission source alone for AC. The study suggests that sTX-MLAA will produce PET images on PET/MR with quantification comparable to PET/CT results during human cardiac exams.
△ Less
Submitted 29 December, 2022;
originally announced December 2022.
-
Block Walsh-Hadamard Transform Based Binary Layers in Deep Neural Networks
Authors:
Hongyi Pan,
Diaa Badawi,
Ahmet Enis Cetin
Abstract:
Convolution has been the core operation of modern deep neural networks. It is well-known that convolutions can be implemented in the Fourier Transform domain. In this paper, we propose to use binary block Walsh-Hadamard transform (WHT) instead of the Fourier transform. We use WHT-based binary layers to replace some of the regular convolution layers in deep neural networks. We utilize both one-dime…
▽ More
Convolution has been the core operation of modern deep neural networks. It is well-known that convolutions can be implemented in the Fourier Transform domain. In this paper, we propose to use binary block Walsh-Hadamard transform (WHT) instead of the Fourier transform. We use WHT-based binary layers to replace some of the regular convolution layers in deep neural networks. We utilize both one-dimensional (1-D) and two-dimensional (2-D) binary WHTs in this paper. In both 1-D and 2-D layers, we compute the binary WHT of the input feature map and denoise the WHT domain coefficients using a nonlinearity which is obtained by combining soft-thresholding with the tanh function. After denoising, we compute the inverse WHT. We use 1D-WHT to replace the $1\times 1$ convolutional layers, and 2D-WHT layers can replace the 3$\times$3 convolution layers and Squeeze-and-Excite layers. 2D-WHT layers with trainable weights can be also inserted before the Global Average Pooling (GAP) layers to assist the dense layers. In this way, we can reduce the number of trainable parameters significantly with a slight decrease in trainable parameters. In this paper, we implement the WHT layers into MobileNet-V2, MobileNet-V3-Large, and ResNet to reduce the number of parameters significantly with negligible accuracy loss. Moreover, according to our speed test, the 2D-FWHT layer runs about 24 times as fast as the regular $3\times 3$ convolution with 19.51\% less RAM usage in an NVIDIA Jetson Nano experiment.
△ Less
Submitted 27 January, 2022; v1 submitted 7 January, 2022;
originally announced January 2022.
-
Detecting Anomaly in Chemical Sensors via L1-Kernels based Principal Component Analysis
Authors:
Hongyi Pan,
Diaa Badawi,
Ishaan Bassi,
Sule Ozev,
Ahmet Enis Cetin
Abstract:
We propose a kernel-PCA based method to detect anomaly in chemical sensors. We use temporal signals produced by chemical sensors to form vectors to perform the Principal Component Analysis (PCA). We estimate the kernel-covariance matrix of the sensor data and compute the eigenvector corresponding to the largest eigenvalue of the covariance matrix. The anomaly can be detected by comparing the diffe…
▽ More
We propose a kernel-PCA based method to detect anomaly in chemical sensors. We use temporal signals produced by chemical sensors to form vectors to perform the Principal Component Analysis (PCA). We estimate the kernel-covariance matrix of the sensor data and compute the eigenvector corresponding to the largest eigenvalue of the covariance matrix. The anomaly can be detected by comparing the difference between the actual sensor data and the reconstructed data from the dominant eigenvector. In this paper, we introduce a new multiplication-free kernel, which is related to the l1-norm for the anomaly detection task. The l1-kernel PCA is not only computationally efficient but also energy-efficient because it does not require any actual multiplications during the kernel covariance matrix computation. Our experimental results show that our kernel-PCA method achieves a higher area under curvature (AUC) score (0.7483) than the baseline regular PCA method (0.7366).
△ Less
Submitted 28 September, 2022; v1 submitted 7 January, 2022;
originally announced January 2022.
-
Neural KEM: A Kernel Method with Deep Coefficient Prior for PET Image Reconstruction
Authors:
Siqi Li,
Kuang Gong,
Ramsey D. Badawi,
Edward J. Kim,
**yi Qi,
Guobao Wang
Abstract:
Image reconstruction of low-count positron emission tomography (PET) data is challenging. Kernel methods address the challenge by incorporating image prior information in the forward model of iterative PET image reconstruction. The kernelized expectation-maximization (KEM) algorithm has been developed and demonstrated to be effective and easy to implement. A common approach for a further improveme…
▽ More
Image reconstruction of low-count positron emission tomography (PET) data is challenging. Kernel methods address the challenge by incorporating image prior information in the forward model of iterative PET image reconstruction. The kernelized expectation-maximization (KEM) algorithm has been developed and demonstrated to be effective and easy to implement. A common approach for a further improvement of the kernel method would be adding an explicit regularization, which however leads to a complex optimization problem. In this paper, we propose an implicit regularization for the kernel method by using a deep coefficient prior, which represents the kernel coefficient image in the PET forward model using a convolutional neural-network. To solve the maximum-likelihood neural network-based reconstruction problem, we apply the principle of optimization transfer to derive a neural KEM algorithm. Each iteration of the algorithm consists of two separate steps: a KEM step for image update from the projection data and a deep-learning step in the image domain for updating the kernel coefficient image using the neural network. This optimization algorithm is guaranteed to monotonically increase the data likelihood. The results from computer simulations and real patient data have demonstrated that the neural KEM can outperform existing KEM and deep image prior methods.
△ Less
Submitted 24 October, 2022; v1 submitted 4 January, 2022;
originally announced January 2022.
-
Multiplication-Avoiding Variant of Power Iteration with Applications
Authors:
Hongyi Pan,
Diaa Badawi,
Runxuan Miao,
Erdem Koyuncu,
Ahmet Enis Cetin
Abstract:
Power iteration is a fundamental algorithm in data analysis. It extracts the eigenvector corresponding to the largest eigenvalue of a given matrix. Applications include ranking algorithms, recommendation systems, principal component analysis (PCA), among many others. In this paper, we introduce multiplication-avoiding power iteration (MAPI), which replaces the standard $\ell_2$-inner products that…
▽ More
Power iteration is a fundamental algorithm in data analysis. It extracts the eigenvector corresponding to the largest eigenvalue of a given matrix. Applications include ranking algorithms, recommendation systems, principal component analysis (PCA), among many others. In this paper, we introduce multiplication-avoiding power iteration (MAPI), which replaces the standard $\ell_2$-inner products that appear at the regular power iteration (RPI) with multiplication-free vector products which are Mercer-type kernel operations related with the $\ell_1$ norm. Precisely, for an $n\times n$ matrix, MAPI requires $n$ multiplications, while RPI needs $n^2$ multiplications per iteration. Therefore, MAPI provides a significant reduction of the number of multiplication operations, which are known to be costly in terms of energy consumption. We provide applications of MAPI to PCA-based image reconstruction as well as to graph-based ranking algorithms. When compared to RPI, MAPI not only typically converges much faster, but also provides superior performance.
△ Less
Submitted 31 January, 2022; v1 submitted 22 October, 2021;
originally announced October 2021.
-
Robust Principal Component Analysis Using a Novel Kernel Related with the L1-Norm
Authors:
Hongyi Pan,
Diaa Badawi,
Erdem Koyuncu,
A. Enis Cetin
Abstract:
We consider a family of vector dot products that can be implemented using sign changes and addition operations only. The dot products are energy-efficient as they avoid the multiplication operation entirely. Moreover, the dot products induce the $\ell_1$-norm, thus providing robustness to impulsive noise. First, we analytically prove that the dot products yield symmetric, positive semi-definite ge…
▽ More
We consider a family of vector dot products that can be implemented using sign changes and addition operations only. The dot products are energy-efficient as they avoid the multiplication operation entirely. Moreover, the dot products induce the $\ell_1$-norm, thus providing robustness to impulsive noise. First, we analytically prove that the dot products yield symmetric, positive semi-definite generalized covariance matrices, thus enabling principal component analysis (PCA). Moreover, the generalized covariance matrices can be constructed in an Energy Efficient (EEF) manner due to the multiplication-free property of the underlying vector products. We present image reconstruction examples in which our EEF PCA method result in the highest peak signal-to-noise ratios compared to the ordinary $\ell_2$-PCA and the recursive $\ell_1$-PCA.
△ Less
Submitted 24 May, 2021;
originally announced May 2021.
-
MF-Net: Compute-In-Memory SRAM for Multibit Precision Inference using Memory-immersed Data Conversion and Multiplication-free Operators
Authors:
Shamma Nasrin,
Diaa Badawi,
Ahmet Enis Cetin,
Wilfred Gomes,
Amit Ranjan Trivedi
Abstract:
We propose a co-design approach for compute-in-memory inference for deep neural networks (DNN). We use multiplication-free function approximators based on ell_1 norm along with a co-adapted processing array and compute flow. Using the approach, we overcame many deficiencies in the current art of in-SRAM DNN processing such as the need for digital-to-analog converters (DACs) at each operating SRAM…
▽ More
We propose a co-design approach for compute-in-memory inference for deep neural networks (DNN). We use multiplication-free function approximators based on ell_1 norm along with a co-adapted processing array and compute flow. Using the approach, we overcame many deficiencies in the current art of in-SRAM DNN processing such as the need for digital-to-analog converters (DACs) at each operating SRAM row/column, the need for high precision analog-to-digital converters (ADCs), limited support for multi-bit precision weights, and limited vector-scale parallelism. Our co-adapted implementation seamlessly extends to multi-bit precision weights, it doesn't require DACs, and it easily extends to higher vector-scale parallelism. We also propose an SRAM-immersed successive approximation ADC (SA-ADC), where we exploit the parasitic capacitance of bit lines of SRAM array as a capacitive DAC. Since the dominant area overhead in SA-ADC comes due to its capacitive DAC, by exploiting the intrinsic parasitic of SRAM array, our approach allows low area implementation of within-SRAM SA-ADC. Our 8$\times$62 SRAM macro, which requires a 5-bit ADC, achieves $\sim$105 tera operations per second per Watt (TOPS/W) with 8-bit input/weight processing at 45 nm CMOS.
△ Less
Submitted 29 January, 2021;
originally announced February 2021.
-
Discrete Cosine Transform Based Causal Convolutional Neural Network for Drift Compensation in Chemical Sensors
Authors:
Diaa Badawi,
Agamyrat Agambayev,
Sule Ozev,
A. Enis Cetin
Abstract:
Sensor drift is a major problem in chemical sensors that requires addressing for reliable and accurate detection of chemical analytes. In this paper, we develop a causal convolutional neural network (CNN) with a Discrete Cosine Transform (DCT) layer to estimate the drift signal. In the DCT module, we apply soft-thresholding nonlinearity in the transform domain to denoise the data and obtain a spar…
▽ More
Sensor drift is a major problem in chemical sensors that requires addressing for reliable and accurate detection of chemical analytes. In this paper, we develop a causal convolutional neural network (CNN) with a Discrete Cosine Transform (DCT) layer to estimate the drift signal. In the DCT module, we apply soft-thresholding nonlinearity in the transform domain to denoise the data and obtain a sparse representation of the drift signal. The soft-threshold values are learned during training. Our results show that DCT layer-based CNNs are able to produce a slowly varying baseline drift signal. We train the CNN on synthetic data and test it on real chemical sensor data. Our results show that we can have an accurate and smooth drift estimate even when the observed sensor signal is very noisy.
△ Less
Submitted 12 November, 2020;
originally announced November 2020.
-
Multiparametric Cardiac 18F-FDG PET: Pilot Comparison of FDG Delivery Rate with 82Rb Myocardial Blood Flow
Authors:
Yang Zuo,
Javier E. Lopez,
Thomas W. Smith,
Cameron C. Foster,
Richard E. Carson,
Ramsey D. Badawi,
Guobao Wang
Abstract:
Myocardial blood flow (MBF) and flow reserve are usually quantified in the clinic with positron emission tomography (PET) using a perfusion-specific radiotracer (e.g. 82Rbchloride). However, the clinical accessibility of existing perfusion tracers remains limited. Meanwhile, 18F-fluorodeoxyglucose (FDG) is a commonly used radiotracer for PET metabolic imaging without similar limitations. In this p…
▽ More
Myocardial blood flow (MBF) and flow reserve are usually quantified in the clinic with positron emission tomography (PET) using a perfusion-specific radiotracer (e.g. 82Rbchloride). However, the clinical accessibility of existing perfusion tracers remains limited. Meanwhile, 18F-fluorodeoxyglucose (FDG) is a commonly used radiotracer for PET metabolic imaging without similar limitations. In this paper, we explore the potential of 18F-FDG for myocardial perfusion imaging by comparing the myocardial FDG delivery rate K1 with MBF as determined by dynamic 82Rb PET in fourteen human subjects with heart disease. Two sets of FDG K1 were derived from one-hour dynamic FDG scans. One was the original FDG K1 estimates and the other was the corresponding K1 values that were linearly normalized for blood glucose levels. A generalized Renkin-Crone model was used to fit FDG K1 with Rb MBF, which then allowed for a nonlinear extraction fraction correction for converting FDG K1 to MBF. The linear correlation between FDG-derived MBF and Rb MBF was moderate (r=0.79) before the glucose normalization and became much improved (r>0.9) after glucose normalization. The extraction fraction of FDG was also similar to that of Rb-chloride in the myocardium. The results from this pilot study suggest that dynamic cardiac FDG-PET with tracer kinetic modeling has the potential to provide MBF in addition to its conventional use for metabolic imaging.
△ Less
Submitted 12 July, 2021; v1 submitted 23 October, 2020;
originally announced October 2020.
-
Multiparametric Cardiac 18F-FDG PET in Humans: Kinetic Model Selection and Identifiability Analysis
Authors:
Yang Zuo,
Ramsey D. Badawi,
Cameron C. Foster,
Thomas Smith,
Javier E. Lopez,
Guobao Wang
Abstract:
Cardiac 18F-FDG PET has been used in clinics to assess myocardial glucose metabolism. Its ability for imaging myocardial glucose transport, however, has rarely been exploited in clinics. Using the dynamic FDG-PET scans of ten patients with coronary artery disease, we investigate in this paper appropriate dynamic scan and kinetic modeling protocols for efficient quantification of myocardial glucose…
▽ More
Cardiac 18F-FDG PET has been used in clinics to assess myocardial glucose metabolism. Its ability for imaging myocardial glucose transport, however, has rarely been exploited in clinics. Using the dynamic FDG-PET scans of ten patients with coronary artery disease, we investigate in this paper appropriate dynamic scan and kinetic modeling protocols for efficient quantification of myocardial glucose transport. Three kinetic models and the effect of scan duration were evaluated by using statistical fit quality, assessing the impact on kinetic quantification, and analyzing the practical identifiability. The results show that the kinetic model selection depends on the scan duration. The reversible two-tissue model was needed for a one-hour dynamic scan. The irreversible two-tissue model was optimal for a scan duration of around 10-15 minutes. If the scan duration was shortened to 2-3 minutes, a one-tissue model was the most appropriate. For global quantification of myocardial glucose transport, we demonstrated that an early dynamic scan with a duration of 10-15 minutes and irreversible kinetic modeling was comparable to the full one-hour scan with reversible kinetic modeling. Myocardial glucose transport quantification provides an additional physiological parameter on top of the existing assessment of glucose metabolism and has the potential to enable single tracer multiparametric imaging in the myocardium.
△ Less
Submitted 23 October, 2020; v1 submitted 12 August, 2020;
originally announced August 2020.
-
Detecting Gas Vapor Leaks Using Uncalibrated Sensors
Authors:
Diaa Badawi,
Tuba Ayhan,
Sule Ozev,
Chengmo Yang,
Alex Orailoglu,
A. Enis Çetin
Abstract:
Chemical and infra-red sensors generate distinct responses under similar conditions because of sensor drift, noise or resolution errors. In this work, we use different time-series data sets obtained by infra-red and E-nose sensors in order to detect Volatile Organic Compounds (VOCs) and Ammonia vapor leaks. We process time-series sensor signals using deep neural networks (DNN). Three neural networ…
▽ More
Chemical and infra-red sensors generate distinct responses under similar conditions because of sensor drift, noise or resolution errors. In this work, we use different time-series data sets obtained by infra-red and E-nose sensors in order to detect Volatile Organic Compounds (VOCs) and Ammonia vapor leaks. We process time-series sensor signals using deep neural networks (DNN). Three neural network algorithms are utilized for this purpose. Additive neural networks (termed AddNet) are based on a multiplication-devoid operator and consequently exhibit energy-efficiency compared to regular neural networks. The second algorithm uses generative adversarial neural networks so as to expose the classifying neural network to more realistic data points in order to help the classifier network to deliver improved generalization. Finally, we use conventional convolutional neural networks as a baseline method and compare their performance with the two aforementioned deep neural network algorithms in order to evaluate their effectiveness empirically.
△ Less
Submitted 20 August, 2019;
originally announced August 2019.