-
Diffusion pore imaging in the presence of extraporal water
Authors:
Dominik Ludwig,
Frederik Bernd Laun,
Karel D. Klika,
Julian Rauch,
Mark Edward Ladd,
Peter Bachert,
Tristan Anselm Kuder
Abstract:
Diffusion-weighted imaging (DWI) is a powerful non-invasive tool which is widely used in clinical routine. Mostly, apparent diffusion coefficient maps are acquired, which cannot be directly related to cellular structure.
More recently it was shown that DWI is able to reconstruct pore shapes using a specialized magnetic field gradient scheme so that cell size distributions may be obtained. So far…
▽ More
Diffusion-weighted imaging (DWI) is a powerful non-invasive tool which is widely used in clinical routine. Mostly, apparent diffusion coefficient maps are acquired, which cannot be directly related to cellular structure.
More recently it was shown that DWI is able to reconstruct pore shapes using a specialized magnetic field gradient scheme so that cell size distributions may be obtained. So far, artificial systems have been used for experimental demonstration without extraporal signal components and relatively low gradient amplitudes.
Therefore, the aim of this study was to investigate the feasibility of diffusion pore imaging in the presence of extraporal fluids and to develop correction methods for effects arising from extraporal signal contributions. Monte Carlo simulations and validation experiments on a 14.1 T spectrometer with a dedicated diffusion probe head were performed.
Both by using a filter gradient approach suppressing extraporal signal components as well as using postprocessing methods relying on the Gaussian phase approximation, it was possible to reconstruct pore space functions in the presence of extraporal fluids with little to no deviations from the expectations. These results may be a significant step towards application of diffusion pore imaging to biological samples. While still ultra-high gradients are required, this problem may be mitigated by recent developments in the field of local gradient coils for human applications.
△ Less
Submitted 10 October, 2021;
originally announced October 2021.
-
NMR diffusion pore imaging: Experimental phase detection by double diffusion encoding
Authors:
Kerstin Demberg,
Frederik Bernd Laun,
Johannes Windschuh,
Reiner Umathum,
Peter Bachert,
Tristan Anselm Kuder
Abstract:
Diffusion pore imaging is an extension of diffusion-weighted nuclear magnetic resonance imaging enabling the direct measurement of the shape of arbitrarily formed, closed pores by probing diffusion restrictions using the motion of spin-bearing particles. Examples of such pores comprise cells in biological tissue or oil containing cavities in porous rocks. All pores contained in the measurement vol…
▽ More
Diffusion pore imaging is an extension of diffusion-weighted nuclear magnetic resonance imaging enabling the direct measurement of the shape of arbitrarily formed, closed pores by probing diffusion restrictions using the motion of spin-bearing particles. Examples of such pores comprise cells in biological tissue or oil containing cavities in porous rocks. All pores contained in the measurement volume contribute to one reconstructed image, which reduces the problem of vanishing signal at increasing resolution present in conventional magnetic resonance imaging. It has been previously experimentally demonstrated that pore imaging using a combination of a long and a narrow magnetic field gradient pulse is feasible. In this work, an experimental verification is presented showing that pores can be imaged using short gradient pulses only. Experiments were carried out using hyperpolarized xenon gas in well-defined pores. The phase required for pore image reconstruction was retrieved from double diffusion encoded (DDE) measurements, while the magnitude could either be obtained from DDE signals or classical diffusion measurements with single encoding. The occurring image artifacts caused by restrictions of the gradient system, insufficient diffusion time, and by the phase reconstruction approach were investigated. Employing short gradient pulses only is advantageous compared to the initial long-narrow approach due to a more flexible sequence design when omitting the long gradient and due to faster convergence to the diffusion long-time limit, which may enable application to larger pores.
△ Less
Submitted 6 May, 2021;
originally announced May 2021.
-
Experimental determination of pore shapes using phase retrieval from q-space NMR diffraction
Authors:
Kerstin Demberg,
Frederik Bernd Laun,
Marco Bertleff,
Peter Bachert,
Tristan Anselm Kuder
Abstract:
This paper presents a novel approach on solving the phase problem in nuclear magnetic resonance (NMR) diffusion pore imaging, a method, which allows imaging the shape of arbitrary closed pores filled with an NMR-detectable medium for investigation of the microstructure of biological tissue and porous materials. Classical q-space imaging composed of two short diffusion-encoding gradient pulses yiel…
▽ More
This paper presents a novel approach on solving the phase problem in nuclear magnetic resonance (NMR) diffusion pore imaging, a method, which allows imaging the shape of arbitrary closed pores filled with an NMR-detectable medium for investigation of the microstructure of biological tissue and porous materials. Classical q-space imaging composed of two short diffusion-encoding gradient pulses yields, analogously to diffraction experiments, the modulus squared of the Fourier transform of the pore image which entails an inversion problem: An unambiguous reconstruction of the pore image requires both magnitude and phase. Here, the phase information is recovered from the Fourier modulus by applying a phase retrieval algorithm. This allows omitting experimentally challenging phase measurements using specialized temporal gradient profiles. A combination of the hybrid input-output algorithm and the error reduction algorithm was used with dynamically adapting support (shrinkwrap extension). No a priori knowledge on the pore shape was fed to the algorithm except for a finite pore extent. The phase retrieval approach proved successful for simulated data with and without noise and was validated in phantom experiments with well-defined pores using hyperpolarized xenon gas.
△ Less
Submitted 6 May, 2021;
originally announced May 2021.
-
Joint multi-contrast Variational Network reconstruction (jVN) with application to rapid 2D and 3D imaging
Authors:
Daniel Polak,
Stephen Cauley,
Berkin Bilgic,
Enhao Gong,
Peter Bachert,
Elfar Adalsteinsson,
Kawin Setsompop
Abstract:
Purpose: To improve the image quality of highly accelerated multi-channel MRI data by learning a joint variational network that reconstructs multiple clinical contrasts jointly.
Methods: Data from our multi-contrast acquisition was embedded into the variational network architecture where shared anatomical information is exchanged by mixing the input contrasts. Complementary k-space sampling acro…
▽ More
Purpose: To improve the image quality of highly accelerated multi-channel MRI data by learning a joint variational network that reconstructs multiple clinical contrasts jointly.
Methods: Data from our multi-contrast acquisition was embedded into the variational network architecture where shared anatomical information is exchanged by mixing the input contrasts. Complementary k-space sampling across imaging contrasts and Bunch-Phase/Wave-Encoding were used for data acquisition to improve the reconstruction at high accelerations. At 3T, our joint variational network approach across T1w, T2w and T2-FLAIR-weighted brain scans was tested for retrospective under-sampling at R=6 (2D) and R=4x4 (3D) acceleration. Prospective acceleration was also performed for 3D data where the combined acquisition time for whole brain coverage at 1 mm isotropic resolution across three contrasts was less than three minutes.
Results: Across all test datasets, our joint multi-contrast network better preserved fine anatomical details with reduced image-blurring when compared to the corresponding single-contrast reconstructions. Improvement in image quality was also obtained through complementary k-space sampling and Bunch-Phase/Wave-Encoding where the synergistic combination yielded the overall best performance as evidenced by exemplarily slices and quantitative error metrics.
Conclusion: By leveraging shared anatomical structures across the jointly reconstructed scans, our joint multi-contrast approach learnt more efficient regularizers which helped to retain natural image appearance and avoid over-smoothing. When synergistically combined with advanced encoding techniques, the performance was further improved, enabling up to R=16-fold acceleration with good image quality. This should help pave the way to very rapid high-resolution brain exams.
△ Less
Submitted 8 October, 2019;
originally announced October 2019.
-
Nonlinear Dipole Inversion (NDI) enables Quantitative Susceptibility Map** (QSM) without parameter tuning
Authors:
Daniel Polak,
Itthi Chatnuntawech,
Jaeyeon Yoon,
Siddharth Srinivasan Iyer,
Jongho Lee,
Peter Bachert,
Elfar Adalsteinsson,
Kawin Setsompop,
Berkin Bilgic
Abstract:
We propose Nonlinear Dipole Inversion (NDI) for high-quality Quantitative Susceptibility Map** (QSM) without regularization tuning, while matching the image quality of state-of-the-art reconstruction techniques. In addition to avoiding over-smoothing that these techniques often suffer from, we also obviate the need for parameter selection. NDI is flexible enough to allow for reconstruction from…
▽ More
We propose Nonlinear Dipole Inversion (NDI) for high-quality Quantitative Susceptibility Map** (QSM) without regularization tuning, while matching the image quality of state-of-the-art reconstruction techniques. In addition to avoiding over-smoothing that these techniques often suffer from, we also obviate the need for parameter selection. NDI is flexible enough to allow for reconstruction from an arbitrary number of head orientations, and outperforms COSMOS even when using as few as 1-direction data. This is made possible by a nonlinear forward-model that uses the magnitude as an effective prior, for which we derived a simple gradient descent update rule. We synergistically combine this physics-model with a Variational Network (VN) to leverage the power of deep learning in the VaNDI algorithm. This technique adopts the simple gradient descent rule from NDI and learns the network parameters during training, hence requires no additional parameter tuning. Further, we evaluate NDI at 7T using highly accelerated Wave-CAIPI acquisitions at 0.5 mm isotropic resolution and demonstrate high-quality QSM from as few as 2-direction data.
△ Less
Submitted 30 September, 2019;
originally announced September 2019.
-
Inverse Z-spectrum analysis for MT- and spillover-corrected and T1-compensated steady-state pulsed CEST-MRI - application to pH-weighted MRI of acute stroke
Authors:
Moritz Zaiss,
Junzhong Xu,
Steffen Goerke,
Imad S. Khan,
Robert J. Singer,
John C. Gore,
Daniel F. Gochberg,
Peter Bachert
Abstract:
Endogenous chemical exchange saturation transfer (CEST) effects are always diluted by competing effects such as direct water proton saturation (spillover) and macromolecular magnetization transfer (MT). This leads to T2-and MT-shine-through effects in the actual biochemical contrast of CEST. Therefore, a simple evaluation algorithm which corrects the CEST signal was searched for. By employing a re…
▽ More
Endogenous chemical exchange saturation transfer (CEST) effects are always diluted by competing effects such as direct water proton saturation (spillover) and macromolecular magnetization transfer (MT). This leads to T2-and MT-shine-through effects in the actual biochemical contrast of CEST. Therefore, a simple evaluation algorithm which corrects the CEST signal was searched for. By employing a recent eigenspace theory valid for spinlock and continuous wave (cw) CEST we predict that the inverse Z-spectrum is beneficial to Z-spectrum itself. Based on this we propose a new spillover- and MT-corrected magnetization transfer ratio (MTRRex) yielding Rex, the exchange dependent relaxation rate in the rotating frame. For verification, the amine proton exchange of creatine in solutions with different agar concentration was studied experimentally at clinical field strength of 3T. In contrast to the compared standard evaluation for pulsed CEST experiments, MTRasym, our approach shows no T2 or MT shine through effect. We demonstrate that spillover can be corrected properly and also quantitative evaluation of pH and creatine concentration is possible which proves MTRRex as quantitative CEST-MRI method. A spillover correction is of special interest for clinical static field strengths and protons resonating near the water peak. This is the case for -OH-CEST effects like gagCEST or glucoCEST, but also amine exchange of creatine or glutamate which require high B1. Although, only showed for amine exchange, we propose our normalization to work generally for DIACEST, PARACEST in slow- and fast exchange regime not just as a correction, but also for quantitative CEST-MRI. Applied to acute stroke induced in rat brain, the corrected CEST signal shows significantly higher contrast between stroke area and normal tissue as well as less B1 dependency compared to conventional approaches.
△ Less
Submitted 26 September, 2013; v1 submitted 26 February, 2013;
originally announced February 2013.
-
Diffusion Pore Imaging by Hyperpolarized Xenon-129 Nuclear Magnetic Resonance
Authors:
Tristan Anselm Kuder,
Peter Bachert,
Johannes Windschuh,
Frederik Bernd Laun
Abstract:
Nuclear magnetic resonance (NMR) diffusion measurements are widely used to derive parameters indirectly related to the microstructure of biological tissues and porous media. However, a direct imaging of cell or pore shapes and sizes would be of high interest. For a long time, determining pore shapes by NMR diffusion acquisitions seemed impossible, because the necessary phase information could not…
▽ More
Nuclear magnetic resonance (NMR) diffusion measurements are widely used to derive parameters indirectly related to the microstructure of biological tissues and porous media. However, a direct imaging of cell or pore shapes and sizes would be of high interest. For a long time, determining pore shapes by NMR diffusion acquisitions seemed impossible, because the necessary phase information could not be preserved. Here we demonstrate experimentally using the measurement technique which we have recently proposed theoretically that the shape of arbitrary closed pores can be imaged by diffusion acquisitions, which yield the phase information. For this purpose, we use hyperpolarized xenon gas in well-defined geometries. The signal can be collected from the whole sample which mainly eliminates the problem of vanishing signal at increasing resolution of conventional NMR imaging. This could be used to non-invasively gain structural information inaccessible so far such as pore or cell shapes, cell density or axon integrity.
△ Less
Submitted 6 December, 2012;
originally announced December 2012.
-
Exchange-dependent relaxation in the rotating frame for slow and intermediate exchange - modeling off-resonant spin-lock and chemical exchange saturation transfer
Authors:
Moritz Zaiss,
Peter Bachert
Abstract:
Chemical exchange observed by NMR saturation transfer (CEST) and spin-lock (SL) experiments provide an MRI contrast by indirect detection of exchanging protons. The determination of the relative concentrations and exchange rates is commonly achieved by numerical integration of the Bloch-McConnell equations. We derive an analytical solution of the Bloch-McConnell equations that describes the magnet…
▽ More
Chemical exchange observed by NMR saturation transfer (CEST) and spin-lock (SL) experiments provide an MRI contrast by indirect detection of exchanging protons. The determination of the relative concentrations and exchange rates is commonly achieved by numerical integration of the Bloch-McConnell equations. We derive an analytical solution of the Bloch-McConnell equations that describes the magnetization of coupled spin populations under radiofrequency irradiation.As CEST and off-resonant SL are equivalent, their steady-state magnetization and dynamics can be predicted by the same single eigenvalue: the longitudinal relaxation rate in the rotating frame R1rho. For the case of slowly exchanging systems, e.g. amide protons, the saturation of the small proton pool is affected by transverse relaxation (R2b). It turns out, that R2b is also significant for intermediate exchange, such as amine- or hydroxyl-exchange or paramagnetic CEST agents, if pools are only partially saturated. We propose a solution for R1rho that includes R2 of the exchanging pool by extending existing approaches, and verify it by numerical simulations. With the appropriate projection factors, we obtain an analytical solution for CEST and SL for nonzero R2 of the exchanging pool, whilst considering the dilution by direct water saturation across the entire Z-spectra. This allows the optimization of irradiation parameters and the quantification of pH-dependent exchange rates and metabolite concentrations. In addition, we propose evaluation methods that correct for concomitant direct saturation effects. It is shown that existing theoretical treatments for CEST are special cases of this approach.
△ Less
Submitted 30 December, 2012; v1 submitted 9 March, 2012;
originally announced March 2012.