-
Beam Phase Retrieval based on Higher Order Modes in Cylindrical SRF Cavities
Authors:
L. Shi,
N. Baboi,
R. M. Jones
Abstract:
The control of beam phase relative to the accelerating RF field within a superconducting cavity is important in many accelerator applications and is of particular importance for a free electron laser facility. As standard practice, the phase is usually inferred from the beam-induced transient field with respect to a timing reference. We report here on an alternative and novel means of beam phase d…
▽ More
The control of beam phase relative to the accelerating RF field within a superconducting cavity is important in many accelerator applications and is of particular importance for a free electron laser facility. As standard practice, the phase is usually inferred from the beam-induced transient field with respect to a timing reference. We report here on an alternative and novel means of beam phase determination based on beam-excited higher order electromagnetic modes and the accelerating electromagnetic mode, which are conveniently available from the same coupler. The monopole modes are immune to the electron beam offset and therefore are best suited for the task. A coupled circuit model is used to assist the development and to rapidly assess the facility of the method. Simulations based on the circuit model indicate that the resolution of this system depends critically on the signal to noise ratio. Beam-based measurements with a test setup were carried out at the European XFEL, Germany. Based on this new method we have routinely obtained a resolution of 0.1°. The best resolution observed with the current setup was 0.03°. These results agree very well with the predictions from those predicted by a circuit model. The system investigated here can be used to provide diagnostic information for the current LLRF system employed in the European XFEL. To this end, the associated electronics are under development. This monitor is the first of its kind that can deliver direct and online measurements of the beam phase with respect to the RF field.
△ Less
Submitted 14 May, 2018;
originally announced May 2018.
-
Higher-order mode-based cavity misalignment measurements at the free-electron laser FLASH
Authors:
Thorsten Hellert,
Nicoleta Baboi,
Liangliang Shi
Abstract:
At the Free-Electron Laser in Hamburg (FLASH) and the European X-Ray Free-Electron Laser, superconducting TeV-energy superconducting linear accelerator (TESLA)-type cavities are used for the acceleration of electron bunches, generating intense free-electron laser (FEL) beams. A long rf pulse structure allows one to accelerate long bunch trains, which considerably increases the efficiency of the ma…
▽ More
At the Free-Electron Laser in Hamburg (FLASH) and the European X-Ray Free-Electron Laser, superconducting TeV-energy superconducting linear accelerator (TESLA)-type cavities are used for the acceleration of electron bunches, generating intense free-electron laser (FEL) beams. A long rf pulse structure allows one to accelerate long bunch trains, which considerably increases the efficiency of the machine. However, intrabunch-train variations of rf parameters and misalignments of rf structures induce significant trajectory variations that may decrease the FEL performance. The accelerating cavities are housed inside cryomodules, which restricts the ability for direct alignment measurements. In order to determine the transverse cavity position, we use a method based on beam-excited dipole modes in the cavities. We have developed an efficient measurement and signal processing routine and present its application to multiple accelerating modules at FLASH. The measured rms cavity offset agrees with the specification of the TESLA modules. For the first time, the tilt of a TESLA cavity inside a cryomodule is measured. The preliminary result agrees well with the ratio between the offset and angle dependence of the dipole mode which we calculated with eigenmode simulations.
△ Less
Submitted 9 January, 2018;
originally announced January 2018.
-
Status of Higher Order Mode Beam Position Monitors in 3.9 GHz Superconducting Accelerating Cavities at FLASH
Authors:
P. Zhang,
N. Baboi,
T. Flisgen,
U. van Rienen,
R. M. Jones,
I. R. R. Shinton
Abstract:
Higher order mode (HOM) beam position monitors (BPM) are being developed for the 3.9 GHz third harmonic superconducting accelerating cavities at FLASH. The transverse beam position in a cavity can be determined utilizing beam-excited HOMs based on dipole components. The existing couplers used for HOM suppression provide necessary signals. The diagnostics principle is similar to a cavity BPM, but r…
▽ More
Higher order mode (HOM) beam position monitors (BPM) are being developed for the 3.9 GHz third harmonic superconducting accelerating cavities at FLASH. The transverse beam position in a cavity can be determined utilizing beam-excited HOMs based on dipole components. The existing couplers used for HOM suppression provide necessary signals. The diagnostics principle is similar to a cavity BPM, but requires no additional vacuum instruments on the linac. The challenges of HOM-BPM for 3.9 GHz cavities lie in the dense HOM spectrum arising from the coupling of the majority HOMs amongst the four cavities in the cryo-module ACC39. HOMs with particularly promising diagnostics features were evaluated using a spectrum analyzer and custom-built test electronics with various data analysis techniques, data reduction was focused on. After careful theoretical and experimental assessment of the HOM spectrum, multi-cavity modes in the region of 5 GHz were chosen to provide a global position over the complete module with superior resolution (~20 um) while trapped modes in the 9 GHz region provide local position in each cavity with comparable resolution (~50 um). A similar HOM-BPM system has been planned for the European XFEL 3.9 GHz module which encompasses eight cavities. This paper reviews both the current status and the future prospects of HOM-BPMs in 3.9 GHz cavities at FLASH.
△ Less
Submitted 22 May, 2013;
originally announced May 2013.
-
Performance of a Downconverter Test-electronics with MTCA-based Digitizers for Beam Position Monitoring in 3.9 GHz Accelerating Cavities
Authors:
T. Wamsat,
N. Baboi,
B. Lorbeer,
P. Zhang
Abstract:
Beam-excited higher order modes (HOM) in 3.9GHz accelerating cavities are planned to be used for beam position monitoring at the European XFEL. The selected HOMs are located around 5440MHz, with a bandwidth of 100MHz and 9060MHz, with a bandwidth of 50MHz. A downconverter electronics, built for tests at FLASH, converts the HOMs to an intermediate frequency of 70MHz. The MTCA (Micro Telecommunicati…
▽ More
Beam-excited higher order modes (HOM) in 3.9GHz accelerating cavities are planned to be used for beam position monitoring at the European XFEL. The selected HOMs are located around 5440MHz, with a bandwidth of 100MHz and 9060MHz, with a bandwidth of 50MHz. A downconverter electronics, built for tests at FLASH, converts the HOMs to an intermediate frequency of 70MHz. The MTCA (Micro Telecommunications Computing Architecture) standard will be used for the XFEL. Thus it is important to have a performance study of the downconverter test-electronics using the MTCA digitizer card SIS8300. In the digitizer the IF frequency of 70MHz is undersampled with a clock frequency of 108MS/s. The paper presents the performance of the digitizer together with the test-electronics. A comparison with a 216MS/s VME (Versa Module Eurocard) digitizer is made.
△ Less
Submitted 15 October, 2012;
originally announced October 2012.
-
HOM Choice Study with Test Electronics for use as Beam Position Diagnostics in 3.9 GHz Accelerating Cavities in FLASH
Authors:
Nicoleta Baboi,
Bastian Lorbeer,
Pei Zhang,
Nathan Eddy,
Brian Fellenz,
Manfred Wendt
Abstract:
Higher Order Modes (HOM) excited by the beam in the 3.9 GHz accelerating cavities in FLASH can be used for beam position diagnostics, as in a cavity beam position monitor. Previous studies of the modal choices within the complicated spectrum have revealed several options: cavity modes with strong coupling to the beam, and therefore with the potential for better position resolution, but which are p…
▽ More
Higher Order Modes (HOM) excited by the beam in the 3.9 GHz accelerating cavities in FLASH can be used for beam position diagnostics, as in a cavity beam position monitor. Previous studies of the modal choices within the complicated spectrum have revealed several options: cavity modes with strong coupling to the beam, and therefore with the potential for better position resolution, but which are propagating within all 4 cavities, and modes localized in the cavities or the beam pipes, which can give localized position information, but which provide worse resolution. For a better characterization of these options, a set of test electronics has been built, which can down-convert various frequencies between about 4 and 9 GHz to 70 MHz. The performance of various 20 MHz bands has been estimated. The best resolution of 20 μm was found for some propagating modes. Based on this study one band at ca. 5 GHz was chosen for high resolution position monitoring and a band at ca. 9 GHz for localized monitoring.
△ Less
Submitted 14 October, 2012;
originally announced October 2012.
-
A Study of Beam Position Diagnostics with Beam-excited Dipole Higher Order Modes using a Downconverter Test Electronics in Third Harmonic 3.9 GHz Superconducting Accelerating Cavities at FLASH
Authors:
P. Zhang,
N. Baboi,
N. Eddy,
B. Fellenz,
R. M. Jones,
B. Lorbeer,
T. Wamsat,
M. Wendt
Abstract:
Beam-excited higher order modes (HOM) in accelerating cavities contain transverse beam position information. Previous studies have narrowed down three modal options for beam position diagnostics in the third harmonic 3.9 GHz cavities at FLASH. Localized modes in the beam pipes at approximately 4.1 GHz and in the fifth cavity dipole band at approximately 9 GHz were found, that can provide a local m…
▽ More
Beam-excited higher order modes (HOM) in accelerating cavities contain transverse beam position information. Previous studies have narrowed down three modal options for beam position diagnostics in the third harmonic 3.9 GHz cavities at FLASH. Localized modes in the beam pipes at approximately 4.1 GHz and in the fifth cavity dipole band at approximately 9 GHz were found, that can provide a local measurement of the beam position. In contrast, propagating modes in the first and second dipole bands between 4.2 and 5.5 GHz can reach a better resolution. All the options were assessed with a specially designed test electronics built by Fermilab. The aim is to define a mode or spectral region suitable for the HOM electronics. Two data analysis techniques are used and compared in extracting beam position information from the dipole HOMs: direct linear regression and singular value decomposition. Current experiments suggest a resolution of 50 μm accuracy in predicting local beam position using modes in the fifth dipole band, and a global resolution of 20 μm over the complete module. Based on these results we decided to build a HOM electronics for the second dipole band and the fifth dipole band, so that we will have both high resolution measurements for the whole module, and localized measurements for individual cavity. The prototype electronics is being built by Fermilab and planned to be tested in FLASH by the end of 2012.
△ Less
Submitted 10 August, 2012;
originally announced August 2012.
-
Higher order mode spectra and the dependence of localized dipole modes on the transverse beam position in third harmonic superconducting cavities at FLASH
Authors:
Pei Zhang,
Nicoleta Baboi,
Roger M. Jones
Abstract:
An electron beam entering an accelerating cavity excites a wakefield. This wakefield can be decomposed into a series of multi-poles or modes. The dominant component of the transverse wakefield is dipole. This report summarizes the higher order mode (HOM) signals of the third harmonic cavities of FLASH measured at various stages: transmission measurements in the single cavity test stand at Fermilab…
▽ More
An electron beam entering an accelerating cavity excites a wakefield. This wakefield can be decomposed into a series of multi-poles or modes. The dominant component of the transverse wakefield is dipole. This report summarizes the higher order mode (HOM) signals of the third harmonic cavities of FLASH measured at various stages: transmission measurements in the single cavity test stand at Fermilab, at CMTB (Cryo-Module Test Bench) and at FLASH, and beam-excited measurements at FLASH. Modes in the first two dipole bands and the fifth dipole band have been identified using a global Lorentzian fit technique. The beam-pipe modes at approximately 4 GHz and some modes in the fifth dipole band have been observed as localized modes, while the first two dipole bands, containing some strong coupling cavity modes, propagate. This report also presents the dependence of the localized dipole modes on the transverse beam position. Linear dependence for various modes has been observed. This makes them suitable for beam position diagnostics. These modes, together with some propagating, strong coupling modes, have been considered in the design of a dedicated electronics for beam diagnostics with HOMs for the third harmonic cavities.
△ Less
Submitted 21 June, 2012;
originally announced June 2012.
-
Higher Order Modes for Beam Diagnostics in Third Harmonic 3.9 GHz Accelerating Module
Authors:
N. Baboi,
N. Eddy,
T. Flisgen,
H. -W. Glock,
R. M. Jones,
I. R. R. Shinton,
P. Zhang
Abstract:
An international team is currently investigating the best way to use Higher Order Modes (HOM) for beam diagnostics in 3.9 GHz cavities. HOMs are excited by charged particles when passing through an accelerating structure. Third harmonic cavities working at 3.9 GHz have been installed in FLASH to linearize the bunch energy profile. A proof-of-principle of using HOMs for beam monitoring has been mad…
▽ More
An international team is currently investigating the best way to use Higher Order Modes (HOM) for beam diagnostics in 3.9 GHz cavities. HOMs are excited by charged particles when passing through an accelerating structure. Third harmonic cavities working at 3.9 GHz have been installed in FLASH to linearize the bunch energy profile. A proof-of-principle of using HOMs for beam monitoring has been made at FLASH in the TESLA 1.3 GHz cavities. Since the wakefields generated in the 3.9 GHz cavities are significantly larger, their impact on the beam should be carefully minimized. Therefore our target is to monitor HOMs and minimize them by aligning the beam on the cavity axis. The difficulty is that, in comparison to the 1.3 GHz cavities, the HOM-spectrum is dense, making it difficult to identify individual modes. Also, most modes propagate through the whole cryo-module containing several cavities, making it difficult to measure local beam properties. In this paper the options for the HOM-based beam position monitors are discussed.
△ Less
Submitted 19 June, 2012;
originally announced June 2012.
-
Eigenmode Simulations of Third Harmonic Superconducting Accelerating Cavities for FLASH and the European XFEL
Authors:
Pei Zhang,
Nicoleta Baboi,
Roger M. Jones
Abstract:
The third harmonic nine-cell cavity (3.9 GHz) for FLASH and the European XFEL has been investigated using simulations performed with the computer code CST Microwave Studio. The band structure of monopole, dipole, quadrupole and sextupole modes for an ideal cavity has been studied. The higher order modes for the nine-cell structure are compared with that of the cavity mid-cell. The R/Q of these eig…
▽ More
The third harmonic nine-cell cavity (3.9 GHz) for FLASH and the European XFEL has been investigated using simulations performed with the computer code CST Microwave Studio. The band structure of monopole, dipole, quadrupole and sextupole modes for an ideal cavity has been studied. The higher order modes for the nine-cell structure are compared with that of the cavity mid-cell. The R/Q of these eigenmodes are calculated.
△ Less
Submitted 13 June, 2012;
originally announced June 2012.
-
A Study of Beam Alignment Based on Coupling Modes in Third Harmonic Superconducting Cavities at FLASH
Authors:
P. Zhang,
N. Baboi,
R. M. Jones
Abstract:
This paper presents a study of beam alignment in accelerating cavities based on beam-excited higher order modes (HOM). Among the transverse HOMs, dipole modes have the dominant contribution, and may have an adverse effect on the beam quality. Since they depend linearly on the transverse beam offset, their effect can be reduced by aligning the beam in the cavity. The study has been made on the four…
▽ More
This paper presents a study of beam alignment in accelerating cavities based on beam-excited higher order modes (HOM). Among the transverse HOMs, dipole modes have the dominant contribution, and may have an adverse effect on the beam quality. Since they depend linearly on the transverse beam offset, their effect can be reduced by aligning the beam in the cavity. The study has been made on the four third harmonic superconducting cavities installed in the ACC39 module at FLASH. Modes with strong beam coupling were monitored while moving the beam and searching for the minimum excited HOM power.
△ Less
Submitted 15 November, 2011;
originally announced November 2011.
-
Study of Beam Diagnostics with Trapped Modes in Third Harmonic Superconducting Cavities at FLASH
Authors:
P. Zhang,
N. Baboi,
R. M. Jones,
I. R. R. Shinton
Abstract:
Off-axis beams passing through an accelerating cavity excite dipole modes among other higher order modes (HOMs). These modes have linear dependence on the transverse beam offset from the cavity axis. Therefore they can be used to monitor the beam position within the cavity. The fifth dipole passband of the third harmonic superconducting cavities at FLASH has modes trapped within each cavity and do…
▽ More
Off-axis beams passing through an accelerating cavity excite dipole modes among other higher order modes (HOMs). These modes have linear dependence on the transverse beam offset from the cavity axis. Therefore they can be used to monitor the beam position within the cavity. The fifth dipole passband of the third harmonic superconducting cavities at FLASH has modes trapped within each cavity and do not propagate through the adjacent beam pipes, while most other cavity modes do. This could enable the beam position measurement in individual cavities. This paper investigates the possibility to use the fifth dipole band for beam alignment in the third harmonic cavity module. Simulations and measurements both with and without beam-excitations are presented. Various analysis methods are used and compared. A good correlation of HOM signals to the beam position is observed.
△ Less
Submitted 10 September, 2011;
originally announced September 2011.
-
Beam-based HOM Study in Third Harmonic SC Cavities for Beam Alignment at FLASH
Authors:
P. Zhang,
N. Baboi,
H. Ecklebe,
T. Flisgen,
H. W. Glock,
R. M. Jones,
B. Lorbeer,
I. R. R. Shinton
Abstract:
An electron beam entering an accelerator cavity excites higher order modes (HOM). These are radiated to HOM couplers and subsequently damped. They can also be used to facilitate beam position monitoring. The modes excited by off-axis beams are the focus of this study. Results are presented on the first analysis of HOM dependency on the beam position for the third harmonic cavities at FLASH. The an…
▽ More
An electron beam entering an accelerator cavity excites higher order modes (HOM). These are radiated to HOM couplers and subsequently damped. They can also be used to facilitate beam position monitoring. The modes excited by off-axis beams are the focus of this study. Results are presented on the first analysis of HOM dependency on the beam position for the third harmonic cavities at FLASH. The analysis is based on the beampipe and cavity dipole modes. Various analysis methods are used and compared to satisfy the needs emerging from the characteristics of those modes. The electric center of each mode is observed by looking for the minima of the HOM signals of different beam positions. A single electron bunch per RF pulse is used.
△ Less
Submitted 22 May, 2011;
originally announced May 2011.
-
Higher Order Modes In Third Harmonic Cavities at Flash
Authors:
I. R. R. Shinton,
N. Baboi,
T. Flisgen,
H. W. Glock,
R. M. Jones,
U van Rienen,
P. Zhang
Abstract:
Transverse modes in the 3.9 GHz cavities, designed and fabricated by FNAL, are reported on. These modes have the potential to cause significant emittance dilution if they are not sufficiently suppressed. Recent probe-based-experiments have indicated significant discrepancies between modes predicted in stand-alone 9-cell cavities compared to those in 4-cavity modules. We employ the code HFSS to ana…
▽ More
Transverse modes in the 3.9 GHz cavities, designed and fabricated by FNAL, are reported on. These modes have the potential to cause significant emittance dilution if they are not sufficiently suppressed. Recent probe-based-experiments have indicated significant discrepancies between modes predicted in stand-alone 9-cell cavities compared to those in 4-cavity modules. We employ the code HFSS to analyze these modes, coupled through beam tubes whose cut-off is above that of the first dipole band.
△ Less
Submitted 3 October, 2010;
originally announced October 2010.
-
First Beam Spectra of SC Third Harmonic Cavity at FLASH
Authors:
P. Zhang,
N. Baboi,
T. Flisgen,
H. W. Glock,
R. M. Jones,
B. Lorbeer,
U van Rienen,
I. R. R. Shinton
Abstract:
Third harmonic superconducting cavities have been designed and fabricated by FNAL to minimise the energy spread along bunches in the FLASH facility at DESY. A module, consisting of four nine-cell 3.9 GHz cavities, has been installed in FLASH. The first measurement with beam excitation is presented, and the comparisons to transmission measurement without beam and simulations are made. Higher order…
▽ More
Third harmonic superconducting cavities have been designed and fabricated by FNAL to minimise the energy spread along bunches in the FLASH facility at DESY. A module, consisting of four nine-cell 3.9 GHz cavities, has been installed in FLASH. The first measurement with beam excitation is presented, and the comparisons to transmission measurement without beam and simulations are made. Higher order modes (HOMs) are able to propagate to adjacent cavities through attached beam tubes. Modes from 1.3 GHz cavities in the module nearby also propagate into this module.
△ Less
Submitted 24 September, 2010;
originally announced September 2010.
-
Higher Order Modes in Third Harmonic Cavities for XFEL/FLASH
Authors:
I. R. R. Shinton,
N. Baboi,
N. Eddy,
T. Flisgen,
H. W. Glock,
R. M. Jones,
N. Juntong,
T. N. Khabiboulline,
U van Rienen,
P. Zhang
Abstract:
We analyse higher order modes in the 3.9 GHz bunch sha** cavities recently installed in the FLASH facility at DESY. We report on recent experimental results on the frequency spectrum from probe based measurements made at CMTB at DESY. These are compared to those predicted by finite difference and finite element computer codes. This study is focused mainly on the dipole component of the multi-pol…
▽ More
We analyse higher order modes in the 3.9 GHz bunch sha** cavities recently installed in the FLASH facility at DESY. We report on recent experimental results on the frequency spectrum from probe based measurements made at CMTB at DESY. These are compared to those predicted by finite difference and finite element computer codes. This study is focused mainly on the dipole component of the multi-pole expansion of the wakefield.. The modes are readily identifiable as single-cavity modes provided the frequencies of these modes are below the cut-off of the inter-connecting beam pipes. The modes above cut-off are coupled to the 4 cavities and are distinct from single cavity modes
△ Less
Submitted 1 June, 2010;
originally announced June 2010.
-
Transverse Impedance Bench Measurements in NLC/JLC Accelerating Structures
Authors:
N. Baboi,
G. B. Bowden,
R. M. Jones,
S. G. Tantawi,
J. R. Lewandowski
Abstract:
The wire method is a more rapid and less costly method to measure impedances of RF components compared to methods using a beam. A setup using a single displaced wire to excite and measure transverse resonant modes in accelerating structures for the Next Linear Collider/ Japanese Linear Collider (NLC/JLC) has been built. The RF signal is coupled into and out of the structure using two matching se…
▽ More
The wire method is a more rapid and less costly method to measure impedances of RF components compared to methods using a beam. A setup using a single displaced wire to excite and measure transverse resonant modes in accelerating structures for the Next Linear Collider/ Japanese Linear Collider (NLC/JLC) has been built. The RF signal is coupled into and out of the structure using two matching sections with a broadband frequency from 11 to 18 GHz. Their contribution to the scattering parameter is minimized by a calibration technique. A standing wave structure has been measured. Difficulties in accurately predicting the modal loss factors were encountered related to the approximations made and to experimental issues. The measurements are presented and comparisons with simulations are made.
△ Less
Submitted 23 May, 2003;
originally announced May 2003.
-
Impedance Measurement Setup for Higher-Order Mode Studies in NLC Accelerator Structures with the Wire Method
Authors:
N. Baboi,
R. M. Jones,
J. W. Wang,
G. B. Bowden,
V. A. Dolgashev,
J. Lewandowski,
S. G. Tantawi,
P. B. Wilson
Abstract:
Dipole modes are the main cause of transverse emittance dilution in the Japanese Linear Collider / Next Linear Collider (JLC/NLC). A diagnostic setup has been built in order to investigate them. The method is based on using a coaxial wire to excite and measure electromagnetic modes of accelerating structures. This method can offer a more efficient and less expensive procedure than the ASSET faci…
▽ More
Dipole modes are the main cause of transverse emittance dilution in the Japanese Linear Collider / Next Linear Collider (JLC/NLC). A diagnostic setup has been built in order to investigate them. The method is based on using a coaxial wire to excite and measure electromagnetic modes of accelerating structures. This method can offer a more efficient and less expensive procedure than the ASSET facility. Initial measurements have been made and are presented in this paper.
△ Less
Submitted 19 September, 2002;
originally announced September 2002.
-
Coaxial Wire Measurements In NLC Accelerating Structures
Authors:
N. Baboi,
R. M. Jones,
G. B. Bowden,
V. Dolgashev,
S. G. Tantawi,
J. W. Wang
Abstract:
The coaxial wire method provides an experimental way of measuring wake fields without the need for a particle beam. A special setup has been designed and is in the process of being fabricated at SLAC to measure the loss factors and synchronous frequencies of dipole modes in both traveling and standing wave structures for the Next Linear Collider (NLC). The method is described and predictions bas…
▽ More
The coaxial wire method provides an experimental way of measuring wake fields without the need for a particle beam. A special setup has been designed and is in the process of being fabricated at SLAC to measure the loss factors and synchronous frequencies of dipole modes in both traveling and standing wave structures for the Next Linear Collider (NLC). The method is described and predictions based on electromagnetic field simulations are discussed
△ Less
Submitted 27 June, 2002;
originally announced June 2002.
-
Multi-Band Dipole And Multipole Wakefields In NLC Traveling Wave Accelerators Using A Wire Measurement Technique
Authors:
R. M. Jones,
N. Baboi,
N. M. Kroll
Abstract:
Dipole wakefields in NLC (Next Linear Collider) structures have been measured with ASSET [1] and well predicted by a circuit model [2]. However, the experimental technique is both time-consuming and expensive. Here, we report on kick factor and synchronous frequency determination for 1st and higher order dipole bands for TW (Traveling Wave) accelerators via a wire measurement technique. This sta…
▽ More
Dipole wakefields in NLC (Next Linear Collider) structures have been measured with ASSET [1] and well predicted by a circuit model [2]. However, the experimental technique is both time-consuming and expensive. Here, we report on kick factor and synchronous frequency determination for 1st and higher order dipole bands for TW (Traveling Wave) accelerators via a wire measurement technique. This stand-alone technique is relatively inexpensive and may lead to an efficient determination of wakefield parameters. The perturbative effect of the wire on the dipole band is pointed out and a two-wire scheme with a limited perturbative effect is also discussed.
[1] C. Adolphsen, 1997, SLAC-PUB-7519 [2] R.M. Jones et al, LINAC96, SLAC-PUB-7287
△ Less
Submitted 27 June, 2002;
originally announced June 2002.
-
Superconducting Superstructure for the TESLA Collider: New Results
Authors:
N. Baboi,
M. Ferrario,
M. Liepe,
J. Sekutowicz
Abstract:
A new cavity-chain layout has been proposed for the main linac of the TESLA linear collider. This superstructure-layout is based upon four 7-cell superconducting standing-wave cavities, coupled by short beam pipes. The main advantages of the superstructure are an increase in the active accelerating length in TESLA and a saving in rf components, especially power couplers, as compared to the prese…
▽ More
A new cavity-chain layout has been proposed for the main linac of the TESLA linear collider. This superstructure-layout is based upon four 7-cell superconducting standing-wave cavities, coupled by short beam pipes. The main advantages of the superstructure are an increase in the active accelerating length in TESLA and a saving in rf components, especially power couplers, as compared to the present 9-cell cavities. The proposed scheme allows to handle the field-flatness tuning and the HOM dam** at sub-unit level, in contrast to standard multi-cell cavities. The superstructure-layout is extensively studied at DESY since 1999. Computations have been performed for the rf properties of the cavity-chain, the bunch-to-bunch energy spread and multibunch dynamics. A copper model of the superstructure has been built in order to compare with the simulations and for testing the field-profile tuning and the HOM dam** scheme. A "proof of principle" niobium prototype of the superstructure is now under construction and will be tested with beam at the TESLA Test Facility in 2001. In this paper we present latest results of these investigations.
△ Less
Submitted 17 August, 2000;
originally announced August 2000.