A Resonant Tank Based Approach for Realizing ZPA in Inductive Power Transfer Systems
Authors:
Abhilash B,
Arun Karuppaswamy B
Abstract:
A load-independent constant current (CC) - constant voltage (CV) output is an important requirement of inductive power transfer (IPT) systems for electric vehicle charging applications. Zero phase angle (ZPA) is also a desirable feature, to ensure a lower power rating requirement for the switching converter. CC and CV output along with ZPA can be achieved by using a suitable compensation topology.…
▽ More
A load-independent constant current (CC) - constant voltage (CV) output is an important requirement of inductive power transfer (IPT) systems for electric vehicle charging applications. Zero phase angle (ZPA) is also a desirable feature, to ensure a lower power rating requirement for the switching converter. CC and CV output along with ZPA can be achieved by using a suitable compensation topology. Equation manipulation techniques can be used for designing the compensation topology. But, it can be mathematically intensive especially for higher order topologies. To overcome this problem, resonant-tank based approaches are adopted in several works to achieve CC and CV conditions. However, equation-based approaches are depended upon either wholly or partly for realizing ZPA. This approach can be tedious and lacks physical insight. The proposed method extends resonant tank approach to achieve ZPA also, besides CC and CV. The need for a separate method to achieve ZPA is eliminated. Further, it simplifies the process in arriving at the constraints that ensure ZPA. As a sample validation, the proposed method is applied to a S-SP compensation topology. The CC-ZPA and CV-ZPA constraints for the S-SP topology are shown to be in line with the ones arrived at using an existing equation-based impedance approach. The simplicity of the proposed method can be observed from the sample validation.
△ Less
Submitted 1 May, 2023;
originally announced May 2023.
Performance Analysis Techniques for Real-time Broadband RFI Filtering System of uGMRT
Authors:
Kaushal D. Buch,
Ruta Kale,
Kishor D. Naik,
Rahul Aragade,
Mekhala Muley,
Sanjay Kudale,
Ajith Kumar B
Abstract:
Electromagnetic radiation from human activities, known as man-made Radio Frequency Interference (RFI), adversely affects radio astronomy observations. In the vicinity of the Upgraded Giant Metrewave Radio Telescope (uGMRT) array, the sparking on power lines is the major cause of interference at observing frequencies less than 800 MHz. A real-time broadband RFI detection and filtering system is imp…
▽ More
Electromagnetic radiation from human activities, known as man-made Radio Frequency Interference (RFI), adversely affects radio astronomy observations. In the vicinity of the Upgraded Giant Metrewave Radio Telescope (uGMRT) array, the sparking on power lines is the major cause of interference at observing frequencies less than 800 MHz. A real-time broadband RFI detection and filtering system is implemented as part of the uGMRT wideband signal processing backend to mitigate the effect of broadband RFI. Performance analysis techniques used for testing and commissioning the system for observations in the beamformer and correlator modes of the uGMRT are presented. The concept and implementation of recording simultaneous unfiltered and filtered data along with data analysis and interpretation is illustrated using an example. For the beamformer mode, spectrogram, single spectral channel, and its Fourier transform is used for performance analysis whereas, in the correlator mode, the cross-correlation function, closure phase, and visibilities from the simultaneously recorded unfiltered and filtered is carried out. These techniques are used for testing the performance of the broadband RFI filter and releasing it for uGMRT users.
△ Less
Submitted 20 September, 2022;
originally announced September 2022.