-
Volt-PF Control Mode for Distribution Feeder Voltage Management Under High Penetration of Distributed Energy Resources
Authors:
Madhura Sondharangalla,
Dan Moldovan,
Raja Ayyanar
Abstract:
Volt-VAr control is a popular method for mitigating overvoltage violations caused by high penetration of distributed energy resources (DERs) in distribution feeders. An inherent limitation of volt-VAr control is that the reactive power (Q) absorbed/injected by the DER is determined based only on the terminal voltage, without considering the active power (P) generated by the DER. This leads to an i…
▽ More
Volt-VAr control is a popular method for mitigating overvoltage violations caused by high penetration of distributed energy resources (DERs) in distribution feeders. An inherent limitation of volt-VAr control is that the reactive power (Q) absorbed/injected by the DER is determined based only on the terminal voltage, without considering the active power (P) generated by the DER. This leads to an inequitable burden of Q support, in the sense that those DERs generating lower P, and hence contributing less to overvoltage issues, may be required to provide more than their share of $Q$ support. The resulting PF of these DERs is required to vary over a wide range, which many current DERs do not support. A new control scheme, namely volt-PF control, is proposed here where the Q support is inherently a function of both the voltage and $P$ from DERs, which alleviates the above concerns while limiting the PF variation within a narrow range of 0.9 to 1. The proposed scheme is validated through extensive static and dynamic simulations on a real, large (8000+ nodes) feeder with very high penetration (>200%) of DERs.The implementation of the new scheme in new and existing commercial hardware inverters is described.
△ Less
Submitted 28 May, 2024;
originally announced May 2024.
-
Analyzing Cross-Phase Effects of Reactive Power Intervention on Distribution Voltage Control
Authors:
Dhaval Dalal,
Anamitra Pal,
Raja Ayyanar
Abstract:
Increasing photovoltaic (PV) penetration in the distribution system can often lead to voltage violations. Mitigation of these violations requires reactive power intervention from PV inverters. However, the unbalanced nature of the distribution system leads to mixed effects on the voltages of nearby nodes for each inverter injecting or absorbing reactive power. In particular, reactive power absorpt…
▽ More
Increasing photovoltaic (PV) penetration in the distribution system can often lead to voltage violations. Mitigation of these violations requires reactive power intervention from PV inverters. However, the unbalanced nature of the distribution system leads to mixed effects on the voltages of nearby nodes for each inverter injecting or absorbing reactive power. In particular, reactive power absorption to reduce over-voltage in one phase can exacerbate over-voltage in a different phase. In this paper, the factors impacting the incremental and decremental voltage effects of reactive power intervention are analyzed in detail. The result of these effects on the distribution system performance is presented to highlight their significance and the need to factor them in for any coordinated voltage control algorithm.
△ Less
Submitted 11 March, 2024; v1 submitted 24 November, 2023;
originally announced November 2023.
-
Improving Photovoltaic Hosting Capacity of Distribution Networks with Coordinated Inverter Control -- A Case Study of the EPRI J1 Feeder
Authors:
Dhaval Dalal,
Madhura Sondharangalla,
Raja Ayyanar,
Anamitra Pal
Abstract:
Adding photovoltaic (PV) systems in distribution networks, while desirable for reducing the carbon footprint, can lead to voltage violations under high solar-low load conditions. The inability of traditional volt-VAr control in eliminating all the violations is also well-known. This paper presents a novel coordinated inverter control methodology that leverages system-wide situational awareness to…
▽ More
Adding photovoltaic (PV) systems in distribution networks, while desirable for reducing the carbon footprint, can lead to voltage violations under high solar-low load conditions. The inability of traditional volt-VAr control in eliminating all the violations is also well-known. This paper presents a novel coordinated inverter control methodology that leverages system-wide situational awareness to significantly improve hosting capacity (HC). The methodology employs a real-time voltage-reactive power (VQ) sensitivity matrix in an iterative linear optimizer to calculate the minimum reactive power intervention from PV inverters needed for mitigating over-voltage without resorting to active power curtailing or requiring step voltage regulator setting changes. The algorithm is validated using the EPRI J1 feeder under an extensive set of realistic use cases and is shown to provide 3x improvement in HC under all scenarios.
△ Less
Submitted 5 November, 2023;
originally announced November 2023.
-
A SOCP-based ACOPF for Operational Scheduling of Three-phase Unbalanced Distribution Systems and Coordination of PV Smart Inverters
Authors:
Mingyue He,
Zahra Soltani,
Mohammad Ghaljehei,
Masoud Esmaili,
Shanshan Ma,
Mengxi Chen,
Mojdeh Khorsand,
Raja Ayyanar,
Vijay Vittal
Abstract:
The proliferation of distributed energy resources (DERs) im-poses new challenges to distribution system operation, e.g., power quality issues. To overcome these challenges and enhance system operation, it is critical to effectively utilize all available resources and accurately characterize unbalanced distribution networks in operational tools. This paper proposes a convex second-order-cone progra…
▽ More
The proliferation of distributed energy resources (DERs) im-poses new challenges to distribution system operation, e.g., power quality issues. To overcome these challenges and enhance system operation, it is critical to effectively utilize all available resources and accurately characterize unbalanced distribution networks in operational tools. This paper proposes a convex second-order-cone programming (SOCP)-based AC optimal power flow (ACOPF) model for three-phase unbalanced distribution net-works, including smart inverters and Volt-VAr controller (VVC) devices. Reactive power-voltage (Q-V) characteristics of smart inverters of solar photovoltaic (PV) units are also modeled. More-over, the settings of Q-V characteristics of VVC are co-optimized within the proposed ACOPF, considering the allowable range of the IEEE 1547-2018 standard. Furthermore, dynamic analyses are conducted to verify the stability of optimal settings of VVC. The proposed models are tested on an actual 1747-node primary distribution feeder in Arizona. The results illustrate the effective-ness of the proposed ACOPF for unbalanced systems in provid-ing a global optimal solution while capturing the non-linearity and non-convexity of ACOPF. By co-optimizing settings, system operation is improved due to the flexibility of adjusting reactive power output from PV units with VVC. The time-domain simu-lations show that the optimal settings result in a stable system
△ Less
Submitted 12 September, 2022;
originally announced September 2022.
-
Optimal Placement of PV Smart Inverters with Volt-VAr Control in Electric Distribution Systems
Authors:
Mengxi Chen,
Shanshan Ma,
Zahra Soltani,
Raja Ayyanar,
Vijay Vittal,
Mojdeh Khorsand
Abstract:
The high R/X ratio of typical distribution systems makes the system voltage vulnerable to the active power injection from distributed energy resources (DERs). Moreover, the intermittent and uncertain nature of the DER generation brings new challenges to the voltage control. This paper proposes a two-stage stochastic optimization strategy to optimally place the PV smart inverters with Volt-VAr capa…
▽ More
The high R/X ratio of typical distribution systems makes the system voltage vulnerable to the active power injection from distributed energy resources (DERs). Moreover, the intermittent and uncertain nature of the DER generation brings new challenges to the voltage control. This paper proposes a two-stage stochastic optimization strategy to optimally place the PV smart inverters with Volt-VAr capability for distribution systems with high photovoltaic (PV) penetration to mitigate voltage violation issues. The proposed optimization strategy enables a planningstage guide for upgrading the existing PV inverters to smart inverters with Volt-VAr capability while considering the operationstage characteristics of the Volt-VAr control. One advantage of this planning strategy is that it utilizes the local control capability of the smart inverter that requires no communication, thus avoiding issues related to communication delays and failures. Another advantage is that the Volt-VAr control characteristic is internally integrated into the optimization model as a set of constraints, making placement decisions more accurate. The objective of the optimization is to minimize the upgrading cost and the number of the smart inverters required while maintaining the voltage profile within the acceptable range. Case studies on an actual 12.47kV, 9km long Arizona utility feeder have been conducted using OpenDSS to validate the effectiveness of the proposed placement strategy in both static and dynamic simulations. Index Terms
△ Less
Submitted 1 July, 2022;
originally announced July 2022.
-
Detailed Primary and Secondary Distribution System Model Enhancement Using AMI Data
Authors:
Karen Montano-Martinez,
Sushrut Thakar,
Shanshan Ma,
Zahra Soltani,
Vijay Vittal,
Mojdeh Khorsand,
Raja Ayyanar,
Cynthia Rojas
Abstract:
Reliable and accurate distribution system modeling, including the secondary network, is essential in examining distribution system performance with high penetration of distributed energy resources (DERs). This paper presents a highly automated, novel method to enhance the accuracy of utility distribution feeder models to capture their performance by matching simulation results with corresponding f…
▽ More
Reliable and accurate distribution system modeling, including the secondary network, is essential in examining distribution system performance with high penetration of distributed energy resources (DERs). This paper presents a highly automated, novel method to enhance the accuracy of utility distribution feeder models to capture their performance by matching simulation results with corresponding field measurements. The method is demonstrated using an actual feeder from an electrical utility with high penetration of DERs. The method proposed uses advanced metering infrastructure (AMI) voltage and derived active power measurements at the customer level, and data acquisition systems (DAS) measurements at the feeder-head, in conjunction with an AC optimal power flow (ACOPF) to estimate customer active and reactive power consumption over a time horizon, while accounting for unmetered loads. Additionally, the method proposed estimates both voltage magnitude and angle for each phase at the unbalanced distribution substation. Furthermore, the accuracy of the method developed is verified by comparing the time-series power flow results obtained from the enhancement algorithm with OpenDSS results. The proposed approach seamlessly manages the data available from the optimization procedure through the final model verification automatically.
△ Less
Submitted 28 May, 2021;
originally announced May 2021.