Resolving non-equilibrium shape variations amongst millions of gold nanoparticles
Authors:
Zhou Shen,
Salah Awel,
Anton Barty,
Richard Bean,
Johan Bielecki,
Martin Bergemann,
Benedikt J. Daurer,
Tomas Ekeberg,
Armando D. Estillore,
Hans Fangohr,
Klaus Giewekemeyer,
Mark S. Hunter,
Mikhail Karnevskiy,
Richard A. Kirian,
Henry Kirkwood,
Yoonhee Kim,
Jayanath Koliyadu,
Holger Lange,
Romain Letrun,
Jannik Lübke,
Abhishek Mall,
Thomas Michelat,
Andrew J. Morgan,
Nils Roth,
Amit K. Samanta
, et al. (14 additional authors not shown)
Abstract:
Nanoparticles, exhibiting functionally relevant structural heterogeneity, are at the forefront of cutting-edge research. Now, high-throughput single-particle imaging (SPI) with x-ray free-electron lasers (XFELs) creates unprecedented opportunities for recovering the shape distributions of millions of particles that exhibit functionally relevant structural heterogeneity. To realize this potential,…
▽ More
Nanoparticles, exhibiting functionally relevant structural heterogeneity, are at the forefront of cutting-edge research. Now, high-throughput single-particle imaging (SPI) with x-ray free-electron lasers (XFELs) creates unprecedented opportunities for recovering the shape distributions of millions of particles that exhibit functionally relevant structural heterogeneity. To realize this potential, three challenges have to be overcome: (1) simultaneous parametrization of structural variability in real and reciprocal spaces; (2) efficiently inferring the latent parameters of each SPI measurement; (3) scaling up comparisons between $10^5$ structural models and $10^6$ XFEL-SPI measurements. Here, we describe how we overcame these three challenges to resolve the non-equilibrium shape distributions within millions of gold nanoparticles imaged at the European XFEL. These shape distributions allowed us to quantify the degree of asymmetry in these particles, discover a relatively stable `shape envelope' amongst nanoparticles, discern finite-size effects related to shape-controlling surfactants, and extrapolate nanoparticles' shapes to their idealized thermodynamic limit. Ultimately, these demonstrations show that XFEL SPI can help transform nanoparticle shape characterization from anecdotally interesting to statistically meaningful.
△ Less
Submitted 9 January, 2024;
originally announced January 2024.
-
On the use of multilayer Laue lenses with X-ray Free Electron Lasers
Authors:
Mauro Prasciolu,
Kevin T. Murray,
Nikolay Ivanov,
Holger Fleckenstein,
Martin Domaracký,
Luca Gelisio,
Fabian Trost,
Kartik Ayyer,
Dietrich Krebs,
Steve Aplin,
Salah Awel,
Ulrike Boesenberg,
Anton Barty,
Armando D. Estillore,
Matthias Fuchs,
Yaroslav Gevorkov,
Joerg Hallmann,
Chan Kim,
Juraj Knoška,
Jochen Küpper,
Chufeng Li,
Wei Lu,
Valerio Mariani,
Andrew J. Morgan,
Johannes Möller
, et al. (12 additional authors not shown)
Abstract:
Multilayer Laue lenses were used for the first time to focus x-rays from an X-ray Free Electron Laser (XFEL). In an experiment, which was performed at the European XFEL, we demonstrated focusing to a spot size of a few tens of nanometers. A series of runs in which the number of pulses per train was increased from 1 to 2, 3, 4, 5, 6, 7, 10, 20 and 30 pulses per train, all with a pulse separation of…
▽ More
Multilayer Laue lenses were used for the first time to focus x-rays from an X-ray Free Electron Laser (XFEL). In an experiment, which was performed at the European XFEL, we demonstrated focusing to a spot size of a few tens of nanometers. A series of runs in which the number of pulses per train was increased from 1 to 2, 3, 4, 5, 6, 7, 10, 20 and 30 pulses per train, all with a pulse separation of 3.55 us, was done using the same set of lenses. The increase in the number of pulses per train was accompanied with an increase of x-ray intensity (transmission) from 9% to 92% at 5 pulses per train, and then the transmission was reduced to 23.5 % when the pulses were increased further. The final working condition was 30 pulses per train and 23.5% transmission. Only at this condition we saw that the diffraction efficiency of the MLLs changed over the course of a pulse train, and this variation was reproducible from train to train. We present the procedure to align and characterize these lenses and discuss challenges working with the pulse trains from this unique x-ray source.
△ Less
Submitted 22 March, 2022;
originally announced March 2022.
-
Unsupervised learning approaches to characterize heterogeneous samples using X-ray single particle imaging
Authors:
Yulong Zhuang,
Salah Awel,
Anton Barty,
Richard Bean,
Johan Bielecki,
Martin Bergemann,
Benedikt J. Daurer,
Tomas Ekeberg,
Armando D. Estillore,
Hans Fangohr,
Klaus Giewekemeyer,
Mark S. Hunter,
Mikhail Karnevskiy,
Richard A. Kirian,
Henry Kirkwood,
Yoonhee Kim,
Jayanath Koliyadu,
Holger Lange,
Romain Letrun,
Jannik Lübke,
Abhishek Mall,
Thomas Michelat,
Andrew J. Morgan,
Nils Roth,
Amit K. Samanta
, et al. (17 additional authors not shown)
Abstract:
One of the outstanding analytical problems in X-ray single particle imaging (SPI) is the classification of structural heterogeneity, which is especially difficult given the low signal-to-noise ratios of individual patterns and that even identical objects can yield patterns that vary greatly when orientation is taken into consideration. We propose two methods which explicitly account for this orien…
▽ More
One of the outstanding analytical problems in X-ray single particle imaging (SPI) is the classification of structural heterogeneity, which is especially difficult given the low signal-to-noise ratios of individual patterns and that even identical objects can yield patterns that vary greatly when orientation is taken into consideration. We propose two methods which explicitly account for this orientation-induced variation and can robustly determine the structural landscape of a sample ensemble. The first, termed common-line principal component analysis (PCA) provides a rough classification which is essentially parameter-free and can be run automatically on any SPI dataset. The second method, utilizing variation auto-encoders (VAEs) can generate 3D structures of the objects at any point in the structural landscape. We implement both these methods in combination with the noise-tolerant expand-maximize-compress (EMC) algorithm and demonstrate its utility by applying it to an experimental dataset from gold nanoparticles with only a few thousand photons per pattern and recover both discrete structural classes as well as continuous deformations. These developments diverge from previous approaches of extracting reproducible subsets of patterns from a dataset and open up the possibility to move beyond studying homogeneous sample sets and study open questions on topics such as nanocrystal growth and dynamics as well as phase transitions which have not been externally triggered.
△ Less
Submitted 13 September, 2021;
originally announced September 2021.
-
Optical funnel to guide and focus virus particles for X-ray laser imaging
Authors:
Salah Awel,
Sebastian Lavin-Varela,
Nils Roth,
Daniel A. Horke,
Andrei V. Rode,
Richard A. Kirian,
Jochen Küpper,
Henry N. Chapman
Abstract:
The need for precise manipulation of nanoparticles in gaseous or near-vacuum environments is encountered in many studies that include aerosol morphology, nanodroplet physics, nanoscale optomechanics, and biomolecular physics. Photophoretic forces, whereby momentum exchange between a particle and surrounding gas is induced with optical light, were recently shown to be a robust means of trap** and…
▽ More
The need for precise manipulation of nanoparticles in gaseous or near-vacuum environments is encountered in many studies that include aerosol morphology, nanodroplet physics, nanoscale optomechanics, and biomolecular physics. Photophoretic forces, whereby momentum exchange between a particle and surrounding gas is induced with optical light, were recently shown to be a robust means of trap** and manipulating nanoparticles in air. We previously proposed a photophoretic "optical funnel" concept for the delivery of bioparticles to the focus of an x-ray free-electron laser (XFEL) beam for femtosecond x-ray diffractive imaging. Here, we describe the formation of a high-aspect-ratio optical funnel and provide a first experimental demonstration of this concept by transversely compressing and concentrating a high-speed beam of aerosolized viruses by a factor of three in a low-pressure environment. These results pave the way toward improved sample delivery efficiency for XFEL imaging experiments as well as other forms of imaging and spectroscopy.
△ Less
Submitted 8 February, 2021; v1 submitted 4 February, 2021;
originally announced February 2021.
-
3D diffractive imaging of nanoparticle ensembles using an X-ray laser
Authors:
Kartik Ayyer,
P. Lourdu Xavier,
Johan Bielecki,
Zhou Shen,
Benedikt J. Daurer,
Amit K. Samanta,
Salah Awel,
Richard Bean,
Anton Barty,
Tomas Ekeberg,
Armando D. Estillore,
Klaus Giewekemeyer,
Mark S. Hunter,
Richard A. Kirian,
Henry Kirkwood,
Yoonhee Kim,
Jayanath Koliyadu,
Holger Lange,
Romain Letruin,
Jannik Lübke,
Andrew J. Morgan,
Nils Roth,
Tokushi Sato,
Marcin Sikorski,
Florian Schulz
, et al. (12 additional authors not shown)
Abstract:
We report the 3D structure determination of gold nanoparticles (AuNPs) by X-ray single particle imaging (SPI). Around 10 million diffraction patterns from gold nanoparticles were measured in less than 100 hours of beam time, more than 100 times the amount of data in any single prior SPI experiment, using the new capabilities of the European X-ray free electron laser which allow measurements of 150…
▽ More
We report the 3D structure determination of gold nanoparticles (AuNPs) by X-ray single particle imaging (SPI). Around 10 million diffraction patterns from gold nanoparticles were measured in less than 100 hours of beam time, more than 100 times the amount of data in any single prior SPI experiment, using the new capabilities of the European X-ray free electron laser which allow measurements of 1500 frames per second. A classification and structural sorting method was developed to disentangle the heterogeneity of the particles and to obtain a resolution of better than 3 nm. With these new experimental and analytical developments, we have entered a new era for the SPI method and the path towards close-to-atomic resolution imaging of biomolecules is apparent.
△ Less
Submitted 17 July, 2020;
originally announced July 2020.
-
Optimizing aerodynamic lenses for single-particle imaging
Authors:
Nils Roth,
Salah Awel,
Daniel A. Horke,
Jochen Küpper
Abstract:
A numerical simulation infrastructure capable of calculating the flow of gas and the trajectories of particles through an aerodynamic lens injector is presented. The simulations increase the fundamental understanding and predict optimized injection geometries and parameters. Our simulation results were compared to previous reports and also validated against experimental data for 500 nm polystyrene…
▽ More
A numerical simulation infrastructure capable of calculating the flow of gas and the trajectories of particles through an aerodynamic lens injector is presented. The simulations increase the fundamental understanding and predict optimized injection geometries and parameters. Our simulation results were compared to previous reports and also validated against experimental data for 500 nm polystyrene spheres from an aerosol-beam- characterization setup. The simulations yielded a detailed understanding of the radial phase-space distribution and highlighted weaknesses of current aerosol injectors for single-particle diffractive imaging. With the aid of these simulations we developed new experimental implementations to overcome current limitations.
△ Less
Submitted 2 July, 2018; v1 submitted 5 December, 2017;
originally announced December 2017.
-
Femtosecond x-ray diffraction from an aerosolized beam of protein nanocrystals
Authors:
Salah Awel,
Richard A. Kirian,
Max O. Wiedorn,
Kenneth R. Beyerlein,
Nils Roth,
Daniel A. Horke,
Dominik Oberthür,
Juraj Knoska,
Valerio Mariani,
Andrew Morgan,
Luigi Adriano,
Alexandra Tolstikova,
P. Lourdu Xavier,
Oleksandr Yefanov,
Andrew Aquila,
Anton Barty,
Shatabdi Roy-Chowdhury,
Mark S. Hunter,
Daniel James,
Joseph S. Robinson,
Uwe Weierstall,
Andrei V. Rode,
Saša Bajt,
Jochen Küpper,
Henry N. Chapman
Abstract:
We demonstrate near-atomic-resolution Bragg diffraction from aerosolized single granulovirus crystals using an x-ray free-electron laser. The form of the aerosol injector is nearly identical to conventional liquid-microjet nozzles, but the x-ray-scattering background is reduced by several orders of magnitude by the use of helium carrier gas rather than liquid. This approach provides a route to stu…
▽ More
We demonstrate near-atomic-resolution Bragg diffraction from aerosolized single granulovirus crystals using an x-ray free-electron laser. The form of the aerosol injector is nearly identical to conventional liquid-microjet nozzles, but the x-ray-scattering background is reduced by several orders of magnitude by the use of helium carrier gas rather than liquid. This approach provides a route to study the weak diffuse or lattice-transform signal arising from small crystals. The high speed of the particles is particularly well suited to upcoming MHz-repetition-rate x-ray free-electron lasers.
△ Less
Submitted 13 January, 2018; v1 submitted 13 February, 2017;
originally announced February 2017.
-
Visualizing aerosol-particle injection for diffractive-imaging experiments
Authors:
Salah Awel,
Richard A. Kirian,
Niko Eckerskorn,
Max Wiedorn,
Daniel A. Horke,
Andrei V. Rode,
Jochen Küpper,
Henry N. Chapman
Abstract:
Delivering sub-micrometer particles to an intense x-ray focus is a crucial aspect of single-particle diffractive-imaging experiments at x-ray free-electron lasers. Enabling direct visualization of sub-micrometer aerosol particle streams without interfering with the operation of the particle injector can greatly improve the overall efficiency of single-particle imaging experiments by reducing the a…
▽ More
Delivering sub-micrometer particles to an intense x-ray focus is a crucial aspect of single-particle diffractive-imaging experiments at x-ray free-electron lasers. Enabling direct visualization of sub-micrometer aerosol particle streams without interfering with the operation of the particle injector can greatly improve the overall efficiency of single-particle imaging experiments by reducing the amount of time and sample consumed during measurements. We have developed in-situ non-destructive imaging diagnostics to aid real-time particle injector optimization and x-ray/particle-beam alignment, based on laser illumination schemes and fast imaging detectors. Our diagnostics are constructed to provide a non-invasive rapid feedback on injector performance during measurements, and have been demonstrated during diffraction measurements at the FLASH free-electron laser.
△ Less
Submitted 19 December, 2015;
originally announced December 2015.