-
Newtonian fluid dynamics in a misaligned parallel-plate rheometer
Authors:
Jian Teng,
Sungwon La,
Jesse T. Ault
Abstract:
A parallel-plate rotational rheometer measures the viscosity of a fluid by rotating the top plate relative to the bottom plate in order to induce a shear on the fluid and measuring the torques and forces that result as a function of the induced rotation rate. Manufacturing imperfections can often lead to unintentional misalignment of the plates of the rheometer, where the top and bottom plates are…
▽ More
A parallel-plate rotational rheometer measures the viscosity of a fluid by rotating the top plate relative to the bottom plate in order to induce a shear on the fluid and measuring the torques and forces that result as a function of the induced rotation rate. Manufacturing imperfections can often lead to unintentional misalignment of the plates of the rheometer, where the top and bottom plates are not perfectly parallel, and this misalignment can affect the fluid dynamics inside the rheometer. This study examines the effect that misalignment has on the viscosity measurements of Newtonian fluids in the limit of small rheometer gap heights. A theoretical model for the behavior of a general Newtonian fluid in a misaligned rheometer with a small gap height is derived using perturbation expansions. The theoretical results show that at small gap heights, misalignment can produce additional secondary velocity components and pressures in the fluid, which affect the forces and moments in the rheometer. In such cases at small Reynolds numbers, the dominant forces and moments acting on the top plate of the rheometer are the viscous force in the direction parallel to the tilt axis, the pressure moment in the direction perpendicular to the tilt axis and in the cross-sectional plane, and the viscous moment in the direction along the height of the rheometer. These forces and moments on the top plate were found to increase as the misalignment tilt angle increases, leading to the rheometer underestimating the viscosity of the fluid by a greater magnitude with larger tilt angles. Three-dimensional numerical simulations validate the theoretical predictions.
△ Less
Submitted 2 June, 2024; v1 submitted 9 October, 2023;
originally announced October 2023.
-
Convection rolls and three-dimensional particle dynamics in merging solute streams
Authors:
Robben E. Migacz,
Guillaume Durey,
Jesse T. Ault
Abstract:
Microparticles migrate in response to gradients in solute concentration through diffusiophoresis and diffusioosmosis. Merging streams of fluid with distinct solute concentrations is a common strategy for producing a steady concentration gradient with continuous flow in microfluidic devices; the solute concentration gradient and consequent diffusiophoresis are primarily normal to the background flo…
▽ More
Microparticles migrate in response to gradients in solute concentration through diffusiophoresis and diffusioosmosis. Merging streams of fluid with distinct solute concentrations is a common strategy for producing a steady concentration gradient with continuous flow in microfluidic devices; the solute concentration gradient and consequent diffusiophoresis are primarily normal to the background flow. This is particularly useful in separation and filtration processes, as it results in regions of particle accrual and depletion in continuous flows. Such systems have been examined in several classic papers on diffusiophoresis, with a focus on the particle dynamics far from boundaries. We show, through experiments, simulations, and theory, that diffusioosmotic flow along certain boundaries can result in significant changes in particle dynamics and particle focusing in near-wall regions. The nonzero velocity at charged surfaces draws solute and particles along the boundary until the flow ultimately recirculates. These "convection rolls," which result in the spanwise migration of polystyrene particles close to boundaries, are apparent near a glass surface but vanish when the surface is coated with gold. The three-dimensional nature of the dynamics could have implications for the design of microfluidic devices: Channel materials can be selected to enhance or suppress near-wall flows. Additionally, we demonstrate the importance of considering solute concentration-dependent models for diffusiophoretic and diffusioosmotic mobility in capturing the dynamics of particles, particularly in regions of low solute concentration.
△ Less
Submitted 31 May, 2023;
originally announced May 2023.
-
Diffusioosmotic dispersion
Authors:
Jian Teng,
Bhargav Rallabandi,
Jesse T. Ault
Abstract:
Solute-surface interactions have garnered considerable interest in recent years as a novel control mechanism for driving unique fluid dynamics and particle transport with potential applications in fields such as biomedicine, the development of microfluidic devices, and enhanced oil recovery. In this study, we will discuss dispersion induced by the diffusioosmotic motion near a charged wall in the…
▽ More
Solute-surface interactions have garnered considerable interest in recent years as a novel control mechanism for driving unique fluid dynamics and particle transport with potential applications in fields such as biomedicine, the development of microfluidic devices, and enhanced oil recovery. In this study, we will discuss dispersion induced by the diffusioosmotic motion near a charged wall in the presence of a solute concentration gradient. Here, we introduce a plug of salt with a Gaussian distribution at the center of a channel with no background flow. As the solute diffuses, the concentration gradient drives a diffusioosmotic slip flow at the walls, which results in a recirculating flow in the channel; this, in turn, drives an advective flux of the solute concentration. This effect leads to cross-stream diffusion of the solute, altering the effective diffusivity of the solute as it diffuses along the channel. We derive theoretical predictions for the solute dynamics using a multiple-timescale analysis to quantify the dispersion driven by the solute-surface interactions. Furthermore, we derive a cross-sectionally averaged concentration equation with an effective diffusivity analogous to that from Taylor dispersion. In addition, we use numerical simulations to validate our theoretical predictions.
△ Less
Submitted 4 May, 2023;
originally announced May 2023.
-
Vortex breakdown in the shear-driven flow in a rectangular cavity
Authors:
H. Wang,
X. Yu,
S. T. Chan,
G. Durey,
A. Shen,
J. T. Ault
Abstract:
The vortex dynamics of laminar flow past a rectangular cavity is investigated using simulations and experiments. The flow is three-dimensional and characterized by a large, dominant vortex structure that fills most of the cavity at moderate Reynolds numbers with a weak, yet significant flow in the axial direction along the vortex core. Classical bubble-type vortex breakdown is observed within the…
▽ More
The vortex dynamics of laminar flow past a rectangular cavity is investigated using simulations and experiments. The flow is three-dimensional and characterized by a large, dominant vortex structure that fills most of the cavity at moderate Reynolds numbers with a weak, yet significant flow in the axial direction along the vortex core. Classical bubble-type vortex breakdown is observed within the cavity above a certain critical Reynolds number, which is a function of the channel width. The critical Reynolds number for the onset of breakdown is determined as a function of channel width, and the evolution and dynamical transitions of the breakdown regions are investigated as functions of the channel width and Reynolds number. At large cavity widths, two vortex breakdown bubbles emerge near the sidewalls symmetric about the centerplane, which grow and eventually merge as the Reynolds number increases. For large-enough widths, the vortex breakdown regions remain well-separated and their structures become independent of the cavity width. The stability and bifurcations of the stagnation points and their transitions to stable/unstable limit cycles are analyzed, and the criticality of the vortex flow is calculated, demonstrating that the vortex breakdown in the cavity agrees with Benjamin's interpretation of criticality. At the intermediate width regime, a single vortex breakdown bubble appears above the critical Reynolds number. In the narrow width regime, the flow exhibits more complicated modes. An additional vortex breakdown mode with reversed flow patterns is observed in this width regime, along with multiple shifts in the stability of stagnation points. The experimental and numerical results also demonstrate the sensitivity of the flow to the inlet conditions, such that relatively small asymmetries upstream can result in significant changes to the vortex breakdown behavior in the cavity.
△ Less
Submitted 8 February, 2023;
originally announced February 2023.
-
Viscosity measurements of glycerol in a parallel-plate rheometer exposed to atmosphere
Authors:
Jesse T. Ault,
Sangwoo Shin,
Allan Garcia,
Antonio Perazzo,
Howard A. Stone
Abstract:
Glycerol is a hygroscopic fluid that spontaneously absorbs water vapor from the atmosphere. For applications involving glycerol, care must be taken to avoid exposure to humidity, since its viscosity decreases quickly as water is absorbed. We report experimental measurements of the viscosity of glycerol in a parallel-plate rheometer where the outer interface is exposed to atmosphere. The measuremen…
▽ More
Glycerol is a hygroscopic fluid that spontaneously absorbs water vapor from the atmosphere. For applications involving glycerol, care must be taken to avoid exposure to humidity, since its viscosity decreases quickly as water is absorbed. We report experimental measurements of the viscosity of glycerol in a parallel-plate rheometer where the outer interface is exposed to atmosphere. The measurements decrease with time as water is absorbed from the atmosphere and transported throughout the glycerol via diffusion and advection. Measured viscosities drop faster at higher relative humidities, confirming the role of hygroscopicity on the transient viscosities. The rate of viscosity decrease shows a non-monotonic relationship with the rheometer gap height. This behavior is explained by considering the transition from diffusion-dominated transport in the narrow gap regime to the large gap regime where transport is dominated by inertia-driven secondary flows. Numerical simulations of the water absorption and transport confirm this non-monotonic behavior. The experimental viscosity measurements show unexpectedly fast decreases at very small gap heights, violating the parallel-plate, axisymmetric model. We propose that this drop-off may be due to misalignment in the rheometer that becomes non-negligible for small gaps. Theoretical considerations show that secondary flows in a misaligned rheometer dominate the typical secondary inertial flows in parallel-plate rheometers at small gaps. Finally, simulations in a misaligned parallel-plate system demonstrate the same sharp drop-off in viscosity measurements at small gap heights. This modeling can be used to estimate the gap height where misalignment effects dominate the transient glycerol viscosity measurements.
△ Less
Submitted 19 January, 2023;
originally announced January 2023.
-
Enhanced singular jet formation in oil-coated bubble bursting
Authors:
Zhengyu Yang,
Bingqiang Ji,
Jesse T Ault,
Jie Feng
Abstract:
Bubbles are ubiquitous in many natural and engineering processes, and bubble bursting aerosols are of particular interest because of their critical role in mass and momentum transfer across interfaces. All prior studies claim that bursting of a millimeter-sized bare bubble at an aqueous surface produces jet drops with a typical size of $\boldsymbol{O}$(100 $\si{\micro\relax}$m), much larger than f…
▽ More
Bubbles are ubiquitous in many natural and engineering processes, and bubble bursting aerosols are of particular interest because of their critical role in mass and momentum transfer across interfaces. All prior studies claim that bursting of a millimeter-sized bare bubble at an aqueous surface produces jet drops with a typical size of $\boldsymbol{O}$(100 $\si{\micro\relax}$m), much larger than film drops of $\boldsymbol{O}$(1 $\si{\micro\relax}$m) from the disintegration of a bubble cap. Here, we document the hitherto unknown phenomenon that jet drops can be as small as a few microns when the bursting bubble is coated by a thin oil layer. We provide evidence that the faster and smaller jet drops result from the singular dynamics of the oil-coated cavity collapse. The unique air-oil-water compound interface offers a distinct dam** mechanism to smooth out the precursor capillary waves during cavity collapse, leading to a more efficient focusing of the dominant wave and thus allowing singular jets over a much wider parameter space beyond that of a bare bubble. We develop a theoretical explanation for the parameter limits of the singular jet regime by considering the interplay among inertia, surface tension, and viscous effects. As such contaminated bubbles are widely observed, the previously unrecognized fast and small contaminant-laden jet drops may enhance bubble-driven flux across the interface, contributing to the aerosolization and airborne transmission of bulk substances.
△ Less
Submitted 16 November, 2022;
originally announced November 2022.
-
CO$_2$-driven diffusiophoresis for removal of bacteria
Authors:
Suin Shim,
Sepideh Khodaparast,
Ching-Yao Lai,
**g Yan,
Jesse T. Ault,
Bhargav Rallabandi,
Orest Shardt,
Howard A. Stone
Abstract:
We investigate CO$_2$-driven diffusiophoresis of colloidal particles and bacterial cells in a Hele-Shaw geometry. Combining experiments and a model, we understand the characteristic length and time scales of CO$_2$-driven diffusiophoresis in relation to system dimensions and CO$_2$ diffusivity. Directional migration of wild-type V. cholerae and a mutant lacking flagella, as well as S. aureus and P…
▽ More
We investigate CO$_2$-driven diffusiophoresis of colloidal particles and bacterial cells in a Hele-Shaw geometry. Combining experiments and a model, we understand the characteristic length and time scales of CO$_2$-driven diffusiophoresis in relation to system dimensions and CO$_2$ diffusivity. Directional migration of wild-type V. cholerae and a mutant lacking flagella, as well as S. aureus and P. aeruginosa, near a dissolving CO$_2$ source shows that diffusiophoresis of bacteria is achieved independent of cell shape and Gram stain. Long-time experiments suggest possible applications for bacterial diffusiophoresis to cleaning systems or anti-biofouling surfaces.
△ Less
Submitted 14 September, 2020;
originally announced September 2020.