Rational Approximation of Golden Angles: Accelerated Reconstructions with Simple and Numerically Reproducible Radial Sampling
Authors:
Nick Scholand,
Philip Schaten,
Christina Graf,
Daniel Mackner,
H. Christian M. Holme,
Moritz Blumenthal,
Andrew Mao,
Jakob Assländer,
Martin Uecker
Abstract:
Purpose: To develop a generic radial sampling scheme that combines the advantages of golden ratio sampling with simplicity of equidistant angular patterns. The irrational angle between consecutive spokes in golden ratio based sampling schemes enables a flexible retrospective choice of temporal resolution, while preserving good coverage of k-space for each individual bin. Nevertheless, irrational i…
▽ More
Purpose: To develop a generic radial sampling scheme that combines the advantages of golden ratio sampling with simplicity of equidistant angular patterns. The irrational angle between consecutive spokes in golden ratio based sampling schemes enables a flexible retrospective choice of temporal resolution, while preserving good coverage of k-space for each individual bin. Nevertheless, irrational increments prohibit precomputation of the point-spread function (PSF), can lead to numerical problems, and require more complex processing steps. To avoid these problems, a new sampling scheme based on a rational approximation of golden angles (RAGA) is developed.
Methods: The theoretical properties of RAGA sampling are mathematically derived. Sidelobe-to-peak ratios (SPR) are numerically computed and compared to the corresponding golden ratio sampling schemes. The sampling scheme is implemented in the BART toolbox and in a radial gradient-echo sequence. Feasibility is shown for quantitative imaging in a phantom and a cardiac scan of a healthy volunteer.
Results: RAGA sampling can accurately approximate golden ratio sampling and has almost identical PSF and SPR. In contrast to golden ratio sampling, each frame can be reconstructed with the same equidistant trajectory using different sampling masks, and the angle of each acquired spoke can be encoded as a small index, which simplifies processing of the acquired data.
Conclusion: RAGA sampling provides the advantages of golden ratio sampling while simplifying data processing, rendering it a valuable tool for dynamic and quantitative MRI.
△ Less
Submitted 30 May, 2024; v1 submitted 5 January, 2024;
originally announced January 2024.
-
Bias-Reduced Neural Networks for Parameter Estimation in Quantitative MRI
Authors:
Andrew Mao,
Sebastian Flassbeck,
Jakob Assländer
Abstract:
Purpose: To develop neural network (NN)-based quantitative MRI parameter estimators with minimal bias and a variance close to the Cramér-Rao bound.
Theory and Methods: We generalize the mean squared error loss to control the bias and variance of the NN's estimates, which involves averaging over multiple noise realizations of the same measurements during training. Bias and variance properties of…
▽ More
Purpose: To develop neural network (NN)-based quantitative MRI parameter estimators with minimal bias and a variance close to the Cramér-Rao bound.
Theory and Methods: We generalize the mean squared error loss to control the bias and variance of the NN's estimates, which involves averaging over multiple noise realizations of the same measurements during training. Bias and variance properties of the resulting NNs are studied for two neuroimaging applications.
Results: In simulations, the proposed strategy reduces the estimates' bias throughout parameter space and achieves a variance close to the Cramér-Rao bound. In vivo, we observe good concordance between parameter maps estimated with the proposed NNs and traditional estimators, such as non-linear least-squares fitting, while state-of-the-art NNs show larger deviations.
Conclusion: The proposed NNs have greatly reduced bias compared to those trained using the mean squared error and offer significantly improved computational efficiency over traditional estimators with comparable or better accuracy.
△ Less
Submitted 10 April, 2024; v1 submitted 13 November, 2023;
originally announced December 2023.
-
Cramér-Rao Bound Optimized Subspace Reconstruction in Quantitative MRI
Authors:
Andrew Mao,
Sebastian Flassbeck,
Cem Gultekin,
Jakob Assländer
Abstract:
We extend the traditional framework for estimating subspace bases that maximize the preserved signal energy to additionally preserve the Cramér-Rao bound (CRB) of the biophysical parameters and, ultimately, improve accuracy and precision in the quantitative maps. To this end, we introduce an \textit{approximate compressed CRB} based on orthogonalized versions of the signal's derivatives with respe…
▽ More
We extend the traditional framework for estimating subspace bases that maximize the preserved signal energy to additionally preserve the Cramér-Rao bound (CRB) of the biophysical parameters and, ultimately, improve accuracy and precision in the quantitative maps. To this end, we introduce an \textit{approximate compressed CRB} based on orthogonalized versions of the signal's derivatives with respect to the model parameters. This approximation permits singular value decomposition (SVD)-based minimization of both the CRB and signal losses during compression. Compared to the traditional SVD approach, the proposed method better preserves the CRB across all biophysical parameters with negligible cost to the preserved signal energy, leading to reduced bias and variance of the parameter estimates in simulation. In vivo, improved accuracy and precision are observed in two quantitative neuroimaging applications, permitting the use of smaller basis sizes in subspace reconstruction and offering significant computational savings.
△ Less
Submitted 3 November, 2023; v1 submitted 29 April, 2023;
originally announced May 2023.
-
Unconstrained quantitative magnetization transfer imaging: disentangling T1 of the free and semi-solid spin pools
Authors:
Jakob Assländer,
Andrew Mao,
Elisa Marchetto,
Erin S Beck,
Francesco La Rosa,
Robert W Charlson,
Timothy M Shepherd,
Sebastian Flassbeck
Abstract:
Since the inception of magnetization transfer (MT) imaging, it has been widely assumed that Henkelman's two spin pools have similar longitudinal relaxation times, which motivated many researchers to constrain them to each other. However, several recent publications reported a $T_1^s$ of the semi-solid spin pool that is much shorter than $T_1^f$ of the free pool. While these studies tailored experi…
▽ More
Since the inception of magnetization transfer (MT) imaging, it has been widely assumed that Henkelman's two spin pools have similar longitudinal relaxation times, which motivated many researchers to constrain them to each other. However, several recent publications reported a $T_1^s$ of the semi-solid spin pool that is much shorter than $T_1^f$ of the free pool. While these studies tailored experiments for robust proofs-of-concept, we here aim to quantify the disentangled relaxation processes on a voxel-by-voxel basis in a clinical imaging setting, i.e., with an effective resolution of 1.24mm isotropic and full brain coverage in 12min. To this end, we optimized a hybrid-state pulse sequence for map** the parameters of an unconstrained MT model. We scanned four people with relapsing-remitting multiple sclerosis (MS) and four healthy controls with this pulse sequence and estimated $T_1^f \approx 1.84$s and $T_1^s \approx 0.34$s in healthy white matter. Our results confirm the reports that $T_1^s \ll T_1^f$ and we argue that this finding identifies MT as an inherent driver of longitudinal relaxation in brain tissue. Moreover, we estimated a fractional size of the semi-solid spin pool of $m_0^s \approx 0.212$, which is larger than previously assumed. An analysis of $T_1^f$ in normal-appearing white matter revealed statistically significant differences between individuals with MS and controls.
△ Less
Submitted 1 April, 2024; v1 submitted 19 January, 2023;
originally announced January 2023.
-
Rapid quantitative magnetization transfer imaging: utilizing the hybrid state and the generalized Bloch model
Authors:
Jakob Assländer,
Cem Gultekin,
Andrew Mao,
Xiaoxia Zhang,
Quentin Duchemin,
Kangning Liu,
Robert W Charlson,
Timothy Shepherd,
Carlos Fernandez-Granda,
Sebastian Flassbeck
Abstract:
Purpose: To explore efficient encoding schemes for quantitative magnetization transfer (qMT) imaging with few constraints on model
Theory and Methods: We combine two recently proposed models in a Bloch-McConnell equation: the dynamics of the free spin pool are confined to the hybrid state, and the dynamics of the semi-solid spin pool are described by the generalized Bloch model. We numerically o…
▽ More
Purpose: To explore efficient encoding schemes for quantitative magnetization transfer (qMT) imaging with few constraints on model
Theory and Methods: We combine two recently proposed models in a Bloch-McConnell equation: the dynamics of the free spin pool are confined to the hybrid state, and the dynamics of the semi-solid spin pool are described by the generalized Bloch model. We numerically optimize the flip angles and durations of a train of radio frequency pulses to enhance the encoding of three qMT parameters while accounting for all 8 parameters of the 2-pool model. We sparsely sample each time frame along this spin dynamics with a 3D radial koosh-ball trajectory, reconstruct the data with subspace modeling, and fit the qMT model with a neural network for computational efficiency.
Results: We extracted qMT parameter maps of the whole brain with an effective resolution of 1.24mm from a 12.6-minute scan. In lesions of multiple sclerosis subjects, we observe a decreased size of the semi-solid spin pool and longer relaxation times, consistent with previous
Conclusion: The encoding power of the hybrid state, combined with regularized image reconstruction, and the accuracy of the generalized Bloch model provide an excellent basis for efficient quantitative magnetization transfer imaging with few constraints on model parameters.
△ Less
Submitted 24 November, 2023; v1 submitted 17 July, 2022;
originally announced July 2022.
-
Minimization of Eddy Current Artifacts in Sequences with Periodic Dynamics
Authors:
Sebastian Flassbeck,
Jakob Assländer
Abstract:
Purpose: To minimize eddy current artifacts in periodic pulse sequences with balanced gradient moments as, e.g., used for quantitative MRI.
Theory and Methods: Eddy current artifacts in balanced sequences result from large jumps in k-space. In quantitative MRI, one often samples some spin dynamics repeatedly while acquiring different parts of k-space. We swap individual k-space lines between dif…
▽ More
Purpose: To minimize eddy current artifacts in periodic pulse sequences with balanced gradient moments as, e.g., used for quantitative MRI.
Theory and Methods: Eddy current artifacts in balanced sequences result from large jumps in k-space. In quantitative MRI, one often samples some spin dynamics repeatedly while acquiring different parts of k-space. We swap individual k-space lines between different repetitions in order to minimize jumps in temporal succession without changing the overall trajectory. This reordering can be formulated as a traveling salesman problem and we tackle the discrete optimization with a simulated annealing algorithm.
Results: Compared to the default ordering, we observe a substantial reduction of artifacts in the reconstructed images and the derived quantitative parameter maps. Comparing two variants of our algorithm, one that resembles the pairing approach originally proposed by Bieri et al., and one that minimizes all k-space jumps equally, we observe slightly lower artifact levels in the latter.
Conclusion: The proposed reordering scheme effectively reduces eddy current artifacts in sequences with balanced gradient moments. In contrast to previous approaches, we capitalize on the periodicity of the sampled signal dynamics, enabling both efficient k-space sampling and minimizing artifacts caused by eddy currents.
△ Less
Submitted 17 November, 2023; v1 submitted 11 March, 2022;
originally announced March 2022.
-
Cramér-Rao bound-informed training of neural networks for quantitative MRI
Authors:
Xiaoxia Zhang,
Quentin Duchemin,
Kangning Liu,
Sebastian Flassbeck,
Cem Gultekin,
Carlos Fernandez-Granda,
Jakob Assländer
Abstract:
Neural networks are increasingly used to estimate parameters in quantitative MRI, in particular in magnetic resonance fingerprinting. Their advantages over the gold standard non-linear least square fitting are their superior speed and their immunity to the non-convexity of many fitting problems. We find, however, that in heterogeneous parameter spaces, i.e. in spaces in which the variance of the e…
▽ More
Neural networks are increasingly used to estimate parameters in quantitative MRI, in particular in magnetic resonance fingerprinting. Their advantages over the gold standard non-linear least square fitting are their superior speed and their immunity to the non-convexity of many fitting problems. We find, however, that in heterogeneous parameter spaces, i.e. in spaces in which the variance of the estimated parameters varies considerably, good performance is hard to achieve and requires arduous tweaking of the loss function, hyper parameters, and the distribution of the training data in parameter space. Here, we address these issues with a theoretically well-founded loss function: the Cramér-Rao bound (CRB) provides a theoretical lower bound for the variance of an unbiased estimator and we propose to normalize the squared error with respective CRB. With this normalization, we balance the contributions of hard-to-estimate and not-so-hard-to-estimate parameters and areas in parameter space, and avoid a dominance of the former in the overall training loss. Further, the CRB-based loss function equals one for a maximally-efficient unbiased estimator, which we consider the ideal estimator. Hence, the proposed CRB-based loss function provides an absolute evaluation metric. We compare a network trained with the CRB-based loss with a network trained with the commonly used means squared error loss and demonstrate the advantages of the former in numerical, phantom, and in vivo experiments.
△ Less
Submitted 5 October, 2021; v1 submitted 22 September, 2021;
originally announced September 2021.
-
Generalized Bloch model: a theory for pulsed magnetization transfer
Authors:
Jakob Assländer,
Cem Gultekin,
Sebastian Flassbeck,
Steffen J Glaser,
Daniel K Sodickson
Abstract:
Purpose: The paper introduces a classical model to describe the dynamics of large spin-1/2 ensembles associated with nuclei bound in large molecule structures, commonly referred to as the semi-solid spin pool, and their magnetization transfer (MT) to spins of nuclei in
Theory and Methods: Like quantum-mechanical descriptions of spin dynamics and like the original Bloch equations, but unlike exis…
▽ More
Purpose: The paper introduces a classical model to describe the dynamics of large spin-1/2 ensembles associated with nuclei bound in large molecule structures, commonly referred to as the semi-solid spin pool, and their magnetization transfer (MT) to spins of nuclei in
Theory and Methods: Like quantum-mechanical descriptions of spin dynamics and like the original Bloch equations, but unlike existing MT models, the proposed model is based on the algebra of angular momentum in the sense that it explicitly models the rotations induced by radio-frequency (RF) pulses. It generalizes the original Bloch model to non-exponential decays, which are, e.g., observed for semi-solid spin pools. The combination of rotations with non-exponential decays is facilitated by describing the latter as Green's functions, comprised in an integro-differential equation.
Results: Our model describes the data of an inversion-recovery magnetization-transfer experiment with varying durations of the inversion pulse substantially better than established models. We made this observation for all measured data, but in particular for pulse durations small than 300$μ$s. Furthermore, we provide a linear approximation of the generalized Bloch model that reduces the simulation time by approximately a factor 15,000, enabling simulation of the spin dynamics caused by a rectangular RF-pulse in roughly 2$μ$s.
Conclusion: The proposed theory unifies the original Bloch model, Henkelman's steady-state theory for magnetization transfer, and the commonly assumed rotation induced by hard pulses (i.e., strong and infinitesimally short applications of RF fields) and describes experimental data better than previous models.
△ Less
Submitted 11 October, 2021; v1 submitted 22 July, 2021;
originally announced July 2021.
-
Hybrid-State Free Precession in Nuclear Magnetic Resonance
Authors:
Jakob Assländer,
Dmitry S. Novikov,
Riccardo Lattanzi,
Daniel K. Sodickson,
Martijn A. Cloos
Abstract:
The dynamics of large spin-1/2 ensembles in the presence of a varying magnetic field are commonly described by the Bloch equation. Most magnetic field variations result in unintuitive spin dynamics, which are sensitive to small deviations in the driving field. Although simplistic field variations can produce robust dynamics, the captured information content is impoverished. Here, we identify adiab…
▽ More
The dynamics of large spin-1/2 ensembles in the presence of a varying magnetic field are commonly described by the Bloch equation. Most magnetic field variations result in unintuitive spin dynamics, which are sensitive to small deviations in the driving field. Although simplistic field variations can produce robust dynamics, the captured information content is impoverished. Here, we identify adiabaticity conditions that span a rich experiment design space with tractable dynamics. These adiabaticity conditions trap the spin dynamics in a one-dimensional subspace. Namely, the dynamics is captured by the absolute value of the magnetization, which is in a transient state, while its direction adiabatically follows the steady state. We define the hybrid state as the co-existence of these two states and identify the polar angle as the effective driving force of the spin dynamics. As an example, we optimize this drive for robust and efficient quantification of spin relaxation times and utilize it for magnetic resonance imaging of the human brain.
△ Less
Submitted 9 July, 2018;
originally announced July 2018.
-
Multicompartment Magnetic Resonance Fingerprinting
Authors:
Sunli Tang,
Carlos Fernandez-Granda,
Sylvain Lannuzel,
Brett Bernstein,
Riccardo Lattanzi,
Martijn Cloos,
Florian Knoll,
Jakob Assländer
Abstract:
Magnetic resonance fingerprinting (MRF) is a technique for quantitative estimation of spin-relaxation parameters from magnetic-resonance data. Most current MRF approaches assume that only one tissue is present in each voxel, which neglects the tissue's microstructure, and may lead to artifacts in the recovered parameter maps at boundaries between tissues. In this work, we propose a multicompartmen…
▽ More
Magnetic resonance fingerprinting (MRF) is a technique for quantitative estimation of spin-relaxation parameters from magnetic-resonance data. Most current MRF approaches assume that only one tissue is present in each voxel, which neglects the tissue's microstructure, and may lead to artifacts in the recovered parameter maps at boundaries between tissues. In this work, we propose a multicompartment MRF model that accounts for the presence of multiple tissues per voxel. The model is fit to the data by iteratively solving a sparse linear inverse problem at each voxel, in order to express the magnetization signal as a linear combination of a few fingerprints in the precomputed dictionary. Thresholding-based methods commonly used for sparse recovery and compressed sensing do not perform well in this setting due to the high local coherence of the dictionary. Instead, we solve this challenging sparse-recovery problem by applying reweighted-l1-norm regularization, implemented using an efficient interior-point method. The proposed approach is validated with simulated data at different noise levels and undersampling factors, as well as with a controlled phantom imaging experiment on a clinical magnetic-resonance system.
△ Less
Submitted 28 February, 2018;
originally announced February 2018.
-
Optimized Quantification of Spin Relaxation Times in the Hybrid State
Authors:
Jakob Assländer,
Riccardo Lattanzi,
Daniel K Sodickson,
Martijn A Cloos
Abstract:
Purpose: The analysis of optimized spin ensemble trajectories for relaxometry in the hybrid state.
Methods: First, we constructed visual representations to elucidate the differential equation that governs spin dynamics in hybrid state. Subsequently, numerical optimizations were performed to find spin ensemble trajectories that minimize the Cramér-Rao bound for $T_1$-encoding, $T_2$-encoding, and…
▽ More
Purpose: The analysis of optimized spin ensemble trajectories for relaxometry in the hybrid state.
Methods: First, we constructed visual representations to elucidate the differential equation that governs spin dynamics in hybrid state. Subsequently, numerical optimizations were performed to find spin ensemble trajectories that minimize the Cramér-Rao bound for $T_1$-encoding, $T_2$-encoding, and their weighted sum, respectively, followed by a comparison of the Cramér-Rao bounds obtained with our optimized spin-trajectories, as well as Look-Locker and multi-spin-echo methods. Finally, we experimentally tested our optimized spin trajectories with in vivo scans of the human brain.
Results: After a nonrecurring inversion segment on the southern hemisphere of the Bloch sphere, all optimized spin trajectories pursue repetitive loops on the northern half of the sphere in which the beginning of the first and the end of the last loop deviate from the others. The numerical results obtained in this work align well with intuitive insights gleaned directly from the governing equation. Our results suggest that hybrid-state sequences outperform traditional methods. Moreover, hybrid-state sequences that balance $T_1$- and $T_2$-encoding still result in near optimal signal-to-noise efficiency. Thus, the second parameter can be encoded at virtually no extra cost.
Conclusion: We provide insights regarding the optimal encoding processes of spin relaxation times in order to guide the design of robust and efficient pulse sequences. We find that joint acquisitions of $T_1$ and $T_2$ in the hybrid state are substantially more efficient than sequential encoding techniques.
△ Less
Submitted 2 December, 2018; v1 submitted 1 March, 2017;
originally announced March 2017.
-
Low Rank Alternating Direction Method of Multipliers Reconstruction for MR Fingerprinting
Authors:
Jakob Assländer,
Martijn A Cloos,
Florian Knoll,
Daniel K Sodickson,
Jürgen Hennig,
Riccardo Lattanzi
Abstract:
Purpose
The proposed reconstruction framework addresses the reconstruction accuracy, noise propagation and computation time for Magnetic Resonance Fingerprinting (MRF).
Methods
Based on a singular value decomposition (SVD) of the signal evolution, MRF is formulated as a low rank inverse problem in which one image is reconstructed for each singular value under consideration. This low rank app…
▽ More
Purpose
The proposed reconstruction framework addresses the reconstruction accuracy, noise propagation and computation time for Magnetic Resonance Fingerprinting (MRF).
Methods
Based on a singular value decomposition (SVD) of the signal evolution, MRF is formulated as a low rank inverse problem in which one image is reconstructed for each singular value under consideration. This low rank approximation of the signal evolution reduces the computational burden by reducing the number of Fourier transformations. Also, the low rank approximation improves the conditioning of the problem, which is further improved by extending the low rank inverse problem to an augmented Lagrangian that is solved by the alternating direction method of multipliers (ADMM). The root mean square error and the noise propagation are analyzed in simulations. For verification, in vivo examples are provided.
Results
The proposed low rank ADMM approach shows a reduced root mean square error compared to the original fingerprinting reconstruction, to a low rank approximation alone and to an ADMM approach without a low rank approximation. Incorporating sensitivity encoding allows for further artifact reduction.
Conclusion
The proposed reconstruction provides robust convergence, reduced computational burden and improved image quality compared to other MRF reconstruction approaches evaluated in this study.
△ Less
Submitted 22 November, 2016; v1 submitted 24 August, 2016;
originally announced August 2016.