-
Status of Xtend telescope onboard X-Ray Imaging and Spectroscopy Mission (XRISM)
Authors:
Koji Mori,
Hiroshi Tomida,
Hiroshi Nakajima,
Takashi Okajima,
Hirofumi Noda,
Hiroyuki Uchida,
Hiromasa Suzuki,
Shogo Benjamin Kobayashi,
Tomokage Yoneyama,
Kouichi Hagino,
Kumiko Nobukawa,
Takaaki Tanaka,
Hiroshi Murakami,
Hideki Uchiyama,
Masayoshi Nobukawa,
Hironori Matsumoto,
Takeshi Tsuru,
Makoto Yamauchi,
Isamu Hatsukade,
Hirokazu Odaka,
Takayoshi Kohmura,
Kazutaka Yamaoka,
Manabu Ishida,
Yoshitomo Maeda,
Takayuki Hayashi
, et al. (38 additional authors not shown)
Abstract:
Xtend is one of the two telescopes onboard the X-ray imaging and spectroscopy mission (XRISM), which was launched on September 7th, 2023. Xtend comprises the Soft X-ray Imager (SXI), an X-ray CCD camera, and the X-ray Mirror Assembly (XMA), a thin-foil-nested conically approximated Wolter-I optics. A large field of view of $38^{\prime}\times38^{\prime}$ over the energy range from 0.4 to 13 keV is…
▽ More
Xtend is one of the two telescopes onboard the X-ray imaging and spectroscopy mission (XRISM), which was launched on September 7th, 2023. Xtend comprises the Soft X-ray Imager (SXI), an X-ray CCD camera, and the X-ray Mirror Assembly (XMA), a thin-foil-nested conically approximated Wolter-I optics. A large field of view of $38^{\prime}\times38^{\prime}$ over the energy range from 0.4 to 13 keV is realized by the combination of the SXI and XMA with a focal length of 5.6 m. The SXI employs four P-channel, back-illuminated type CCDs with a thick depletion layer of 200 $μ$m. The four CCD chips are arranged in a 2$\times$2 grid and cooled down to $-110$ $^{\circ}$C with a single-stage Stirling cooler. Before the launch of XRISM, we conducted a month-long spacecraft thermal vacuum test. The performance verification of the SXI was successfully carried out in a course of multiple thermal cycles of the spacecraft. About a month after the launch of XRISM, the SXI was carefully activated and the soundness of its functionality was checked by a step-by-step process. Commissioning observations followed the initial operation. We here present pre- and post-launch results verifying the Xtend performance. All the in-orbit performances are consistent with those measured on ground and satisfy the mission requirement. Extensive calibration studies are ongoing.
△ Less
Submitted 28 June, 2024;
originally announced June 2024.
-
Multi-Image X-ray Interferometer Module: I. design concept and proof-of-concept experiments with fine-pitch slits
Authors:
Kazunori Asakura,
Kiyoshi Hayashida,
Tomoki Kawabata,
Yoneyama Tomokage,
Hirofumi Noda,
Hironori Matsumoto,
Hiroshi Tsunemi,
Hiroshi Nakajima,
Hisamitsu Awaki,
Junko S. Hiraga
Abstract:
We propose a novel x-ray imaging system, Multi-Image X-ray Interferometer Module (MIXIM), with which a very high angular resolution can be achieved even with a small system size. MIXIM is composed of equally-spaced multiple slits and an x-ray detector, and its angular resolution is inversely proportional to the distance between them. Here we report our evaluation experiments of MIXIM with a newly…
▽ More
We propose a novel x-ray imaging system, Multi-Image X-ray Interferometer Module (MIXIM), with which a very high angular resolution can be achieved even with a small system size. MIXIM is composed of equally-spaced multiple slits and an x-ray detector, and its angular resolution is inversely proportional to the distance between them. Here we report our evaluation experiments of MIXIM with a newly adopted CMOS sensor with a high spatial resolution of 2.5 μm. Our previous experiments with a prototype MIXIM were limited to one-dimensional imaging, and more importantly, the achieved angular resolution was only {\sim}1", severely constrained due to the spatial resolution of the adopted sensor with a pixel size of 4.25 μm. By contrast, one-dimensional images obtained in this experiment had a higher angular resolution of 0.5" when a configured system size was only {\sim}1 m, which demonstrates that MIXIM can simultaneously realize a high angular resolution and compact size. We also successfully obtained a two-dimensional profile of an x-ray beam for the first time for MIXIM by introducing a periodic pinhole mask. The highest angular resolution achieved in our experiments is smaller than 0.1" with a mask-sensor distance of 866.5 cm, which shows the high scalability of MIXIM.
△ Less
Submitted 4 May, 2023;
originally announced May 2023.
-
Xtend, the Soft X-ray Imaging Telescope for the X-ray Imaging and Spectroscopy Mission (XRISM)
Authors:
Koji Mori,
Hiroshi Tomida,
Hiroshi Nakajima,
Takashi Okajima,
Hirofumi Noda,
Takaaki Tanaka,
Hiroyuki Uchida,
Kouichi Hagino,
Shogo Benjamin Kobayashi,
Hiromasa Suzuki,
Tessei Yoshida,
Hiroshi Murakami,
Hideki Uchiyama,
Masayoshi Nobukawa,
Kumiko Nobukawa,
Tomokage Yoneyama,
Hironori Matsumoto,
Takeshi Tsuru,
Makoto Yamauchi,
Isamu Hatsukade,
Manabu Ishida,
Yoshitomo Maeda,
Takayuki Hayashi,
Keisuke Tamura,
Rozenn Boissay-Malaquin
, et al. (30 additional authors not shown)
Abstract:
Xtend is a soft X-ray imaging telescope developed for the X-Ray Imaging and Spectroscopy Mission (XRISM). XRISM is scheduled to be launched in the Japanese fiscal year 2022. Xtend consists of the Soft X-ray Imager (SXI), an X-ray CCD camera, and the X-ray Mirror Assembly (XMA), a thin-foil-nested conically approximated Wolter-I optics. The SXI uses the P-channel, back-illuminated type CCD with an…
▽ More
Xtend is a soft X-ray imaging telescope developed for the X-Ray Imaging and Spectroscopy Mission (XRISM). XRISM is scheduled to be launched in the Japanese fiscal year 2022. Xtend consists of the Soft X-ray Imager (SXI), an X-ray CCD camera, and the X-ray Mirror Assembly (XMA), a thin-foil-nested conically approximated Wolter-I optics. The SXI uses the P-channel, back-illuminated type CCD with an imaging area size of 31 mm on a side. The four CCD chips are arranged in a 2$\times$2 grid and can be cooled down to $-120$ $^{\circ}$C with a single-stage Stirling cooler. The XMA nests thin aluminum foils coated with gold in a confocal way with an outer diameter of 45~cm. A pre-collimator is installed in front of the X-ray mirror for the reduction of the stray light. Combining the SXI and XMA with a focal length of 5.6m, a field of view of $38^{\prime}\times38^{\prime}$ over the energy range from 0.4 to 13 keV is realized. We have completed the fabrication of the flight model of both SXI and XMA. The performance verification has been successfully conducted in a series of sub-system level tests. We also carried out on-ground calibration measurements and the data analysis is ongoing.
△ Less
Submitted 13 March, 2023;
originally announced March 2023.
-
X-ray polarimetry reveals the magnetic field topology on sub-parsec scales in Tycho's supernova remnant
Authors:
Riccardo Ferrazzoli,
Patrick Slane,
Dmitry Prokhorov,
** Zhou,
Jacco Vink,
Niccolò Bucciantini,
Enrico Costa,
Niccolò Di Lalla,
Alessandro Di Marco,
Paolo Soffitta,
Martin C. Weisskopf,
Kazunori Asakura,
Luca Baldini,
Jeremy Heyl,
Philip E. Kaaret,
Frédéric Marin,
Tsunefumi Mizuno,
C. -Y. Ng,
Melissa Pesce-Rollins,
Stefano Silvestri,
Carmelo Sgrò,
Douglas A. Swartz,
Toru Tamagawa,
Yi-Jung Yang,
Iván Agudo
, et al. (75 additional authors not shown)
Abstract:
Supernova remnants are commonly considered to produce most of the Galactic cosmic rays via diffusive shock acceleration. However, many questions about the physical conditions at shock fronts, such as the magnetic-field morphology close to the particle acceleration sites, remain open. Here we report the detection of a localized polarization signal from some synchrotron X-ray emitting regions of Tyc…
▽ More
Supernova remnants are commonly considered to produce most of the Galactic cosmic rays via diffusive shock acceleration. However, many questions about the physical conditions at shock fronts, such as the magnetic-field morphology close to the particle acceleration sites, remain open. Here we report the detection of a localized polarization signal from some synchrotron X-ray emitting regions of Tycho's supernova remnant made by the Imaging X-ray Polarimetry Explorer. The derived polarization degree of the X-ray synchrotron emission is 9+/-2% averaged over the whole remnant, and 12+/-2% at the rim, higher than the 7-8% polarization value observed in the radio band. In the west region the polarization degree is 23+/-4%. The X-ray polarization degree in Tycho is higher than for Cassiopeia A, suggesting a more ordered magnetic-field or a larger maximum turbulence scale. The measured tangential polarization direction corresponds to a radial magnetic field, and is consistent with that observed in the radio band. These results are compatible with the expectation of turbulence produced by an anisotropic cascade of a radial magnetic-field near the shock, where we derive a magnetic-field amplification factor of 3.4+/-0.3. The fact that this value is significantly smaller than those expected from acceleration models is indicative of highly anisotropic magnetic-field turbulence, or that the emitting electrons either favor regions of lower turbulence, or accumulate close to where the magnetic-field orientation is preferentially radially oriented due to hydrodynamical instabilities.
△ Less
Submitted 22 January, 2023; v1 submitted 18 January, 2023;
originally announced January 2023.
-
X-ray polarization detection of Cassiopeia A with IXPE
Authors:
Jacco Vink,
Dmitry Prokhorov,
Riccardo Ferrazzoli,
Patrick Slane,
** Zhou,
Kazunori Asakura,
Luca Baldini,
Niccolo Bucciantini,
Enrico Costa,
Alessandro Di Marco,
Jeremy Heyl,
Frederic Marin,
Tsunefumi Mizuno,
C. Y. Ng,
Melissa Pesce-Rollins,
Brian D. Ramsey,
John Rankin,
Ajay Ratheesh,
Carmelo Sgro,
Paolo Soffitta,
Douglas A. Swartz,
Toru Tamagawa,
Martin C. Weisskopf,
Yi-Jung Yang,
Ronaldo Bellazzini
, et al. (70 additional authors not shown)
Abstract:
We report on a $\sim 5σ$ detection of polarized 3-6 keV X-ray emission from the supernova remnant Cassiopeia A with the Imaging X-ray Polarimetry Explorer (IXPE). The overall polarization degree of $1.8 \pm 0.3$% is detected by summing over a large region, assuming circular symmetry for the polarization vectors. The measurements imply an average polarization degree for the synchrotron component of…
▽ More
We report on a $\sim 5σ$ detection of polarized 3-6 keV X-ray emission from the supernova remnant Cassiopeia A with the Imaging X-ray Polarimetry Explorer (IXPE). The overall polarization degree of $1.8 \pm 0.3$% is detected by summing over a large region, assuming circular symmetry for the polarization vectors. The measurements imply an average polarization degree for the synchrotron component of $\sim 2.5$%, and close to 5% for the X-ray synchrotron-domimated forward-shock region. These numbers are based on an assessment of the thermal and non-thermal radiation contributions, for which we used a detailed spatial-spectral model based on Chandra X-ray data. A pixel-by-pixel search for polarization provides a few tentative detections from discrete regions at the $\sim 3σ$ confidence level. Given the number of pixels, the significance is {insufficient} to claim a detection for individual pixels, but implies considerable turbulence on scales smaller than the angular resolution. Cas A's X-ray continuum emission is dominated by synchrotron radiation from regions within $\lesssim 10^{17}$ cm of the forward- and reverse shocks. We find that i) the measured polarization angle corresponds to a radially-oriented magnetic field, similar to what has been inferred from radio observations; ii) the X-ray polarization degree is lower than in the radio band ($\sim 5$%). Since shock compression should impose a tangential magnetic field structure, the IXPE results imply that magnetic-fields are reoriented within $\sim 10^{17}$cm of the shock. If the magnetic-field alignment is due to locally enhanced acceleration near quasi-parallel shocks, the preferred X-ray polarization angle suggests a size of $3\times 10^{16}$ cm for cells with radial magnetic fields.
△ Less
Submitted 22 August, 2022; v1 submitted 14 June, 2022;
originally announced June 2022.
-
Metastable structure of photoexcited WO$_{3}$ determined by the pump--probe extended X-ray absorption fine structure spectroscopy and constrained thorough search analysis
Authors:
Daiki Kido,
Hiromitsu Uehara,
Satoru Takakusagi,
Jun-ya Hasegawa,
Kiyotaka Asakura,
Yohei Uemura,
Yuki Wakisaka,
Akihiro Koide,
Toshihiko Yokoyama,
Yasuhiro Niwa,
Shunsuke Nozawa,
Kohei Ichiyanagi,
Ryo Fukaya,
Shin-ichi Adachi,
Harry Jenkins,
Tokushi Sato
Abstract:
We have determined the local structure of photoexcited metastable WO$_3$ created 150 ps after 400 nm laser irradiation by the pulse pump--probe L$_3$-edge extended X-ray absorption fine structure spectroscopy and the constrained thorough search analysis. We have found a highly distorted octahedral local structure with one of the shortest W=O bonds being further shortened to 1.66 Åwhile the other f…
▽ More
We have determined the local structure of photoexcited metastable WO$_3$ created 150 ps after 400 nm laser irradiation by the pulse pump--probe L$_3$-edge extended X-ray absorption fine structure spectroscopy and the constrained thorough search analysis. We have found a highly distorted octahedral local structure with one of the shortest W=O bonds being further shortened to 1.66 Åwhile the other five bonds were elongated even though theoretical calculations predicted the reverse change. We discuss this contradiction and propose a possible structure for the metastable state.
△ Less
Submitted 17 June, 2022; v1 submitted 14 May, 2022;
originally announced May 2022.
-
Suzaku Detection of Solar Wind Charge Exchange Emission from a Variety of Highly-ionized Ions in an Interplanetary Coronal Mass Ejection
Authors:
Kazunori Asakura,
Hironori Matsumoto,
Koki Okazaki,
Tomokage Yoneyama,
Hirofumi Noda,
Kiyoshi Hayashida,
Hiroshi Tsunemi,
Hiroshi Nakajima,
Satoru Katsuda,
Daiki Ishi,
Yuichiro Ezoe
Abstract:
X-ray emission generated through solar-wind charge exchange (SWCX) is known to contaminate X-ray observation data, the amount of which is often significant or even dominant, particularly in the soft X-ray band, when the main target is comparatively weak diffuse sources, depending on the space weather during the observation. In particular, SWCX events caused by interplanetary coronal mass ejections…
▽ More
X-ray emission generated through solar-wind charge exchange (SWCX) is known to contaminate X-ray observation data, the amount of which is often significant or even dominant, particularly in the soft X-ray band, when the main target is comparatively weak diffuse sources, depending on the space weather during the observation. In particular, SWCX events caused by interplanetary coronal mass ejections (ICMEs) tend to be spectrally rich and to provide critical information about the metal abundance in the ICME plasma. We analyzed the SN1006 background data observed with Suzaku on 2005 September 11 shortly after an X6-class solar flare, signatures of which were separately detected together with an associated ICME. We found that the data include emission lines from a variety of highly ionized ions generated through SWCX. The relative abundances of the detected ions were found to be consistent with those in past ICME-driven SWCX events. Thus, we conclude that this event was ICME-driven. In addition, we detected a sulfur XVI line for the first time as one from the SWCX emission, the fact of which suggests that it is the most spectrally-rich SWCX event ever observed. We suggest that observations of ICME-driven SWCX events can provide a unique probe to study the population of highly-ionized ions in the plasma, which is difficult to measure in currently-available in-situ observations.
△ Less
Submitted 22 February, 2021;
originally announced February 2021.
-
Experimental studies on the charge transfer inefficiency of CCD developed for the soft X-ray imaging telescope Xtend aboard the XRISM satellite
Authors:
Yoshiaki Kanemaru,
** Sato,
Toshiyuki Takaki,
Yuta Terada,
Koji Mori,
Mariko Saito,
Kumiko K. Nobukawa,
Takaaki Tanaka,
Hiroyuki Uchida,
Kiyoshi Hayashida,
Hironori Matsumoto,
Hirofumi Noda,
Maho Hanaoka,
Tomokage Yoneyama,
Koki Okazaki,
Kazunori Asakura,
Shotaro Sakuma,
Kengo Hattori,
Ayami Ishikura,
Yuki Amano,
Hiromichi Okon,
Takeshi G. Tsuru,
Hiroshi Tomida,
Hikari Kashimura,
Hiroshi Nakajima
, et al. (16 additional authors not shown)
Abstract:
We present experimental studies on the charge transfer inefficiency (CTI) of charge-coupled device (CCD) developed for the soft X-ray imaging telescope, Xtend, aboard the XRISM satellite. The CCD is equipped with a charge injection (CI) capability, in which sacrificial charge is periodically injected to fill the charge traps. By evaluating the re-emission of the trapped charge observed behind the…
▽ More
We present experimental studies on the charge transfer inefficiency (CTI) of charge-coupled device (CCD) developed for the soft X-ray imaging telescope, Xtend, aboard the XRISM satellite. The CCD is equipped with a charge injection (CI) capability, in which sacrificial charge is periodically injected to fill the charge traps. By evaluating the re-emission of the trapped charge observed behind the CI rows, we find that there are at least three trap populations with different time constants. The traps with the shortest time constant, which is equivalent to a transfer time of approximately one pixel, are mainly responsible for the trailing charge of an X-ray event seen in the following pixel. A comparison of the trailing charge in two clocking modes reveals that the CTI depends not only on the transfer time but also on the area, namely the imaging or storage area. We construct a new CTI model with taking into account with both transfer-time and area dependence. This model reproduces the data obtained in both clocking modes consistently. We also examine apparent flux dependence of the CTI observed without the CI technique. The higher incident X-ray flux is, the lower the CTI value becomes. It is due to a sacrificial charge effect by another X-ray photon. This effect is found to be negligible when the CI technique is used.
△ Less
Submitted 15 September, 2020; v1 submitted 14 September, 2020;
originally announced September 2020.
-
Optical Blocking Performance of CCDs Developed for the X-ray Astronomy Satellite XRISM
Authors:
Hiroyuki Uchida,
Takaaki Tanaka,
Yuki Amano,
Hiromichi Okon,
Takeshi G. Tsuru,
Hirofumi Noda,
Kiyoshi Hayashida,
Hironori Matsumoto,
Maho Hanaoka,
Tomokage Yoneyama,
Koki Okazaki,
Kazunori Asakura,
Shotaro Sakuma,
Kengo Hattori,
Ayami Ishikura,
Hiroshi Nakajima,
Mariko Saito,
Kumiko K. Nobukawa,
Hiroshi Tomida,
Yoshiaki Kanemaru,
** Sato,
Toshiyuki Takaki,
Yuta Terada,
Koji Mori,
Hikari Kashimura
, et al. (21 additional authors not shown)
Abstract:
We have been develo** P-channel Charge-Coupled Devices (CCDs) for the upcoming X-ray Astronomy Satellite XRISM, planned to be launched in 2021. While the basic design of the CCD camera (Soft X-ray Imager: SXI) is almost the same as that of the lost Hitomi (ASTRO-H) observatory, we are planning to reduce the "light leakages" that is one of the largest problems recognized in Hitomi data. We adopte…
▽ More
We have been develo** P-channel Charge-Coupled Devices (CCDs) for the upcoming X-ray Astronomy Satellite XRISM, planned to be launched in 2021. While the basic design of the CCD camera (Soft X-ray Imager: SXI) is almost the same as that of the lost Hitomi (ASTRO-H) observatory, we are planning to reduce the "light leakages" that is one of the largest problems recognized in Hitomi data. We adopted a double-layer optical blocking layer on the XRISM CCDs and also added an extra aluminum layer on the backside of them. We develop a newly designed test sample CCD and irradiate it with optical light to evaluate the optical blocking performance. As a result, light leakages are effectively reduced compared with that of the Hitomi CCDs. We thus conclude that the issue is solved by the new design and that the XRISM CCDs satisfy the mission requirement for the SXI.
△ Less
Submitted 16 July, 2020; v1 submitted 15 July, 2020;
originally announced July 2020.
-
Radiation hardness of a p-channel notch CCD developed for the X-ray CCD camera onboard the XRISM satellite
Authors:
Yoshiaki Kanemaru,
** Sato,
Koji Mori,
Hiroshi Nakajima,
Yusuke Nishioka,
Ayaki Takeda,
Kiyoshi Hayashida,
Hironori Matsumoto,
Junichi Iwagaki,
Koki Okazaki,
Kazunori Asakura,
Tomokage Yoneyama,
Hiroyuki Uchida,
Hiromichi Okon,
Takaaki Tanaka,
Takeshi G. Tsuru,
Hiroshi Tomida,
Takeo Shimoi,
Takayoshi Kohmura,
Kouichi Hagino,
Hiroshi Murakami,
Shogo B. Kobayashi,
Makoto Yamauchi,
Isamu Hatsukade,
Masayoshi Nobukawa
, et al. (8 additional authors not shown)
Abstract:
We report the radiation hardness of a p-channel CCD developed for the X-ray CCD camera onboard the XRISM satellite. This CCD has basically the same characteristics as the one used in the previous Hitomi satellite, but newly employs a notch structure of potential for signal charges by increasing the implant concentration in the channel. The new device was exposed up to approximately…
▽ More
We report the radiation hardness of a p-channel CCD developed for the X-ray CCD camera onboard the XRISM satellite. This CCD has basically the same characteristics as the one used in the previous Hitomi satellite, but newly employs a notch structure of potential for signal charges by increasing the implant concentration in the channel. The new device was exposed up to approximately $7.9 \times 10^{10} \mathrm{~protons~cm^{-2}}$ at 100 MeV. The charge transfer inefficiency was estimated as a function of proton fluence with an ${}^{55} \mathrm{Fe}$ source. A device without the notch structure was also examined for comparison. The result shows that the notch device has a significantly higher radiation hardness than those without the notch structure including the device adopted for Hitomi. This proves that the new CCD is radiation tolerant for space applications with a sufficient margin.
△ Less
Submitted 1 June, 2019;
originally announced June 2019.
-
X-ray imaging polarimetry with a 2.5-$\mathrmμ$m pixel CMOS sensor for visible light at room temperature
Authors:
Kazunori Asakura,
Kiyoshi Hayashida,
Takashi Hanasaka,
Tomoki Kawabata,
Tomokage Yoneyama,
Koki Okazaki,
Shuntaro Ide,
Hirofumi Noda,
Hironori Matsumoto,
Hiroshi Tsunemi,
Hisamitsu Awaki,
Hiroshi Nakajima
Abstract:
X-ray polarimetry in astronomy has not been exploited well, despite its importance. The recent innovation of instruments is changing this situation. We focus on a complementary MOS (CMOS) pixel detector with small pixel size and employ it as an x-ray photoelectron tracking polarimeter. The CMOS detector we employ is developed by GPixel Inc., and has a pixel size of 2.5 $\mathrmμ$m $\times$ 2.5…
▽ More
X-ray polarimetry in astronomy has not been exploited well, despite its importance. The recent innovation of instruments is changing this situation. We focus on a complementary MOS (CMOS) pixel detector with small pixel size and employ it as an x-ray photoelectron tracking polarimeter. The CMOS detector we employ is developed by GPixel Inc., and has a pixel size of 2.5 $\mathrmμ$m $\times$ 2.5 $\mathrmμ$m. Although it is designed for visible light, we succeed in detecting x-ray photons with an energy resolution of 176 eV (FWHM) at 5.9 keV at room temperature and the atmospheric condition. We measure the x-ray detection efficiency and polarimetry sensitivity by irradiating polarized monochromatic x-rays at BL20B2 in SPring-8, the synchrotron radiation facility in Japan. We obtain modulation factors of 7.63% $\pm$ 0.07% and 15.5% $\pm$ 0.4% at 12.4 keV and 24.8 keV, respectively. It demonstrates that this sensor can be used as an x-ray imaging spectrometer and polarimeter with the highest spatial resolution ever tested.
△ Less
Submitted 31 May, 2019;
originally announced June 2019.
-
Search for double-beta decay of 136Xe to excited states of 136Ba with the KamLAND-Zen experiment
Authors:
KamLAND-Zen Collaboration,
:,
K. Asakura,
A. Gando,
Y. Gando,
T. Hachiya,
S. Hayashida,
H. Ikeda,
K. Inoue,
K. Ishidoshiro,
T. Ishikawa,
S. Ishio,
M. Koga,
S. Matsuda,
T. Mitsui,
D. Motoki,
K. Nakamura,
S. Obara,
M. Otani,
T. Oura,
I. Shimizu,
Y. Shirahata,
J. Shirai,
A. Suzuki,
H. Tachibana
, et al. (21 additional authors not shown)
Abstract:
A search for double-beta decays of 136Xe to excited states of 136Ba has been performed with the first phase data set of the KamLAND-Zen experiment. The 0+1, 2+1 and 2+2 transitions of 0ν\{beta}\{beta} decay were evaluated in an exposure of 89.5kg-yr of 136Xe, while the same transitions of 2ν\{beta}\{beta} decay were evaluated in an exposure of 61.8kg-yr. No excess over background was found for all…
▽ More
A search for double-beta decays of 136Xe to excited states of 136Ba has been performed with the first phase data set of the KamLAND-Zen experiment. The 0+1, 2+1 and 2+2 transitions of 0ν\{beta}\{beta} decay were evaluated in an exposure of 89.5kg-yr of 136Xe, while the same transitions of 2ν\{beta}\{beta} decay were evaluated in an exposure of 61.8kg-yr. No excess over background was found for all decay modes. The lower half-life limits of the 2+1 state transitions of 0ν\{beta}\{beta} and 2ν\{beta}\{beta} decay were improved to T(0ν, 0+ \rightarrow 2+) > 2.6\times10^25 yr and T(2ν, 0+ \rightarrow 2+) > 4.6\times10^23 yr (90% C.L.), respectively. We report on the first experimental lower half-life limits for the transitions to the 0+1 state of 136Xe for 0ν\{beta}\{beta} and 2ν\{beta}\{beta} decay. They are T (0ν, 0+ \rightarrow 0+) > 2.4\times10^25 yr and T(2ν, 0+ \rightarrow 0+) > 8.3\times10^23 yr (90% C.L.). The transitions to the 2+2 states are also evaluated for the first time to be T(0ν, 0+ \rightarrow 2+) > 2.6\times10^25 yr and T(2ν, 0+ \rightarrow 2+) > 9.0\times10^23 yr (90% C.L.). These results are compared to recent theoretical predictions.
△ Less
Submitted 8 December, 2015; v1 submitted 12 September, 2015;
originally announced September 2015.
-
KamLAND Sensitivity to Neutrinos from Pre-Supernova Stars
Authors:
K. Asakura,
A. Gando,
Y. Gando,
T. Hachiya,
S. Hayashida,
H. Ikeda,
K. Inoue,
K. Ishidoshiro,
T. Ishikawa,
S. Ishio,
M. Koga,
S. Matsuda,
T. Mitsui,
D. Motoki,
K. Nakamura,
S. Obara,
T. Oura,
I. Shimizu,
Y. Shirahata,
J. Shirai,
A. Suzuki,
H. Tachibana,
K. Tamae,
K. Ueshima,
H. Watanabe
, et al. (22 additional authors not shown)
Abstract:
In the late stages of nuclear burning for massive stars ($M>8~M_{\sun}$), the production of neutrino-antineutrino pairs through various processes becomes the dominant stellar cooling mechanism. As the star evolves, the energy of these neutrinos increases and in the days preceding the supernova a significant fraction of emitted electron anti-neutrinos exceeds the energy threshold for inverse beta d…
▽ More
In the late stages of nuclear burning for massive stars ($M>8~M_{\sun}$), the production of neutrino-antineutrino pairs through various processes becomes the dominant stellar cooling mechanism. As the star evolves, the energy of these neutrinos increases and in the days preceding the supernova a significant fraction of emitted electron anti-neutrinos exceeds the energy threshold for inverse beta decay on free hydrogen. This is the golden channel for liquid scintillator detectors because the coincidence signature allows for significant reductions in background signals. We find that the kiloton-scale liquid scintillator detector KamLAND can detect these pre-supernova neutrinos from a star with a mass of $25~M_{\sun}$ at a distance less than 690~pc with 3$σ$ significance before the supernova. This limit is dependent on the neutrino mass ordering and background levels. KamLAND takes data continuously and can provide a supernova alert to the community.
△ Less
Submitted 22 January, 2016; v1 submitted 3 June, 2015;
originally announced June 2015.
-
Study of electron anti-neutrinos associated with gamma-ray bursts using KamLAND
Authors:
K. Asakura,
A. Gando,
Y. Gando,
T. Hachiya,
S. Hayashida,
H. Ikeda,
K. Inoue,
K. Ishidoshiro,
T. Ishikawa,
S. Ishio,
M. Koga,
S. Matsuda,
T. Mitsui,
D. Motoki,
K. Nakamura,
S. Obara,
Y. Oki,
T. Oura,
I. Shimizu,
Y. Shirahata,
J. Shirai,
A. Suzuki,
H. Tachibana,
K. Tamae,
K. Ueshima
, et al. (23 additional authors not shown)
Abstract:
We search for electron anti-neutrinos ($\overlineν_e$) from long and short-duration gamma-ray bursts~(GRBs) using data taken by the KamLAND detector from August 2002 to June 2013. No statistically significant excess over the background level is found. We place the tightest upper limits on $\overlineν_e$ fluence from GRBs below 7 MeV and place first constraints on the relation between…
▽ More
We search for electron anti-neutrinos ($\overlineν_e$) from long and short-duration gamma-ray bursts~(GRBs) using data taken by the KamLAND detector from August 2002 to June 2013. No statistically significant excess over the background level is found. We place the tightest upper limits on $\overlineν_e$ fluence from GRBs below 7 MeV and place first constraints on the relation between $\overlineν_e$ luminosity and effective temperature.
△ Less
Submitted 15 June, 2015; v1 submitted 7 March, 2015;
originally announced March 2015.
-
Super Bloch oscillations with modulated interaction
Authors:
Elena Díaz,
Alberto García Mena,
Kunihiko Asakura,
Christopher Gaul
Abstract:
We study super Bloch oscillations of ultracold atoms in a shaken lattice potential, subjected to a harmonically modulated mean-field interaction. Usually, any interaction leads to the decay of the wave packet and its super Bloch oscillation. Here, we use the phases of interaction and shaking with respect to the free Bloch oscillation as control parameters. We find two types of long-living cases: (…
▽ More
We study super Bloch oscillations of ultracold atoms in a shaken lattice potential, subjected to a harmonically modulated mean-field interaction. Usually, any interaction leads to the decay of the wave packet and its super Bloch oscillation. Here, we use the phases of interaction and shaking with respect to the free Bloch oscillation as control parameters. We find two types of long-living cases: (i) suppression of the immediate broadening of the wave packet, and (ii) dynamical stability of all degrees of freedom. The latter relies on the rather robust symmetry argument of cyclic time [Gaul et al., Phys. Rev. A 84, 053627 (2011)].
△ Less
Submitted 21 January, 2013; v1 submitted 6 December, 2012;
originally announced December 2012.