-
Tapered ultra-high Numerical Aperture optical fiber tip for Nitrogen Vacancy ensembles based endoscope in a fluidic environment
Authors:
Dewen Duan,
Vinaya Kumar Kavatamane,
Sri Ran**i Arumugam,
Yan-Kai Tzeng,
Huan-Cheng Chang,
Gopalakrishnan Balasubramanian
Abstract:
Fixing a diamond containing a high density of Nitrogen-Vacancy (NV) center ensembles on the apex of a multimode optical fiber (MMF) extends the applications of NV-based endoscope sensors. Replacing the normal MMF with a tapered MMF (MMF-taper) has enhanced the fluorescence (FL) collection efficiency from the diamond and achieved a high spatial resolution NV-based endoscope. The MMF-taper's high FL…
▽ More
Fixing a diamond containing a high density of Nitrogen-Vacancy (NV) center ensembles on the apex of a multimode optical fiber (MMF) extends the applications of NV-based endoscope sensors. Replacing the normal MMF with a tapered MMF (MMF-taper) has enhanced the fluorescence (FL) collection efficiency from the diamond and achieved a high spatial resolution NV-based endoscope. The MMF-taper's high FL collection efficiency is the direct result of multiple internal reflections in the tapered region caused by silica, which has a higher refractive index (RI) than the surrounding air. However, for applications involving fluidic environments whose RI is close to or higher than that of the silica, the MMF-taper loses its FL collection significantly. Here, to overcome this challenge, we replaced the MMF-taper with an ultra-high numerical aperture (NA) microstructured optical fiber (MOF) which is tapered and sealed its air capillaries at the tapered end. Since the end-sealed air capillaries along the tapered MOF (MOF-taper) have isolated the MOF core from the surrounding medium, the core retains its high FL collection and NV excitation efficiency in liquids regardless of their RI values. Such a versatile NV-based endoscope could potentially find broad applications in fluidic environments where many biological processes and chemical reactions occur.
△ Less
Submitted 24 December, 2019;
originally announced December 2019.
-
Efficient nitrogen-vacancy centers' fluorescence excitation and collection from micrometer-sized diamond by a tapered optical fiber
Authors:
Dewen Duan,
Guanxiang Du,
Vinaya Kumar Kavatamane,
Sri Ran**i Arumugam,
Yan-Kai Tzeng,
Huan-Cheng Chang,
Gopalakrishnan Balasubramanian
Abstract:
Efficiently excite nitrogen-vacancy (NV) centers in diamond and collect their fluorescence significantly benefit the fiber-optic-based NV sensors. Here, using a tapered optical fiber (TOF) tip, we significantly improve the efficiency of the laser excitation and fluorescence collection of the NV, thus enhance the sensitivity of the fiber-optic based micron-sized diamond magnetic sensor. Numerical c…
▽ More
Efficiently excite nitrogen-vacancy (NV) centers in diamond and collect their fluorescence significantly benefit the fiber-optic-based NV sensors. Here, using a tapered optical fiber (TOF) tip, we significantly improve the efficiency of the laser excitation and fluorescence collection of the NV, thus enhance the sensitivity of the fiber-optic based micron-sized diamond magnetic sensor. Numerical calculation shows that the TOF tip delivers a high numerical aperture (NA) and has a high fluorescence excitation and collection efficiency. Experiments demonstrate that using such TOF tip can obtain up to over 7-fold the fluorescence excitation efficiency and over15-fold the fluorescence collection efficiency of a flat-ended (non-TOF) fiber. Such fluorescence collection enhances the sensitivity of the optical fiber-based diamond NV magnetometer, thus extending its potential application region.
△ Less
Submitted 9 October, 2018; v1 submitted 8 October, 2018;
originally announced October 2018.
-
Enhancing fluorescence excitation and collection from the nitrogen-vacancy center in diamond through a micro-concave mirror
Authors:
Dewen Duan,
Vinaya Kumar Kavatamane,
Sri Ran**i Arumugam,
Ganesh Rahane,
Yan-Kai Tzeng,
Huan-Cheng Chang,
Hitoshi Sumiya,
Shinobu Onoda,
Junichi Isoya,
Gopalakrishnan Balasubramanian
Abstract:
We experimentally demonstrate a simple and robust optical fibers based method to achieve simultaneously efficient excitation and fluorescence collection from Nitrogen-Vacancy (NV) defects containing micro-crystalline diamond. We fabricate a suitable micro-concave (MC) mirror that focuses scattered excitation laser light into the diamond located at the focal point of the mirror. At the same instanc…
▽ More
We experimentally demonstrate a simple and robust optical fibers based method to achieve simultaneously efficient excitation and fluorescence collection from Nitrogen-Vacancy (NV) defects containing micro-crystalline diamond. We fabricate a suitable micro-concave (MC) mirror that focuses scattered excitation laser light into the diamond located at the focal point of the mirror. At the same instance, the mirror also couples the fluorescence light exiting out of the diamond crystal in the opposite direction of the optical fiber back into the optical fiber within its light acceptance cone. This part of fluorescence would have been otherwise lost from reaching the detector. Our proof-of-principle demonstration achieves a 25 times improvement in fluorescence collection compared to the case of not using any mirrors. The increase in light collection favors getting high signal-to-noise ratio (SNR) optically detected magnetic resonance (ODMR) signals hence offers a practical advantage in fiber-based NV quantum sensors. Additionally, we compacted the NV sensor system by replacing some bulky optical elements in the optical path with a 1x2 fiber optical coupler in our optical system. This reduces the complexity of the system and provides portability and robustness needed for applications like magnetic endoscopy and remote-magnetic sensing.
△ Less
Submitted 24 August, 2018; v1 submitted 12 April, 2018;
originally announced April 2018.