-
GRB 070724B: the first Gamma Ray Burst localized by SuperAGILE and its Swift X-ray Afterglow
Authors:
E. Del Monte,
M. Feroci,
L. Pacciani,
Y. Evangelista,
I. Donnarumma,
P. Soffitta,
E. Costa,
I. Lapshov,
F. Lazzarotto,
M. Rapisarda,
A. Argan,
G. Barbiellini,
M. Basset,
A. Bulgarelli,
P. Caraveo,
A. Chen,
G. Di Cocco,
L. Foggetta,
F. Fuschino,
M. Galli,
F. Gianotti,
A. Giuliani,
C. Labanti,
P. Lipari,
F. Longo
, et al. (29 additional authors not shown)
Abstract:
GRB 070724B is the first Gamma Ray Burst localized by SuperAGILE, the hard X-ray monitor aboard the AGILE satellite. The coordinates of the event were published $\sim 19$ hours after the trigger. The Swift X-Ray Telescope pointed at the SuperAGILE location and detected the X-ray afterglow inside the SuperAGILE error circle. The AGILE gamma-ray Tracker and Minicalorimeter did not detect any signi…
▽ More
GRB 070724B is the first Gamma Ray Burst localized by SuperAGILE, the hard X-ray monitor aboard the AGILE satellite. The coordinates of the event were published $\sim 19$ hours after the trigger. The Swift X-Ray Telescope pointed at the SuperAGILE location and detected the X-ray afterglow inside the SuperAGILE error circle. The AGILE gamma-ray Tracker and Minicalorimeter did not detect any significant gamma ray emission associated with GRB 070724B in the MeV and GeV range, neither prompt nor delayed. Searches of the optical afterglow were performed by the Swift UVOT and the Palomar automated 60-inch telescopes without any significant detection. Similarly the Very Large Array did not detect a radio afterglow. This is the first GRB event with a firm upper limit in the 100 MeV -- 30 GeV energy range, associated with an X-ray afterglow.
△ Less
Submitted 4 December, 2007;
originally announced December 2007.
-
SuperAGILE: the hard X-ray Imager for the AGILE space mission
Authors:
M. Feroci,
E. Costa,
P. Soffitta,
E. Del Monte,
G. Di Persio,
I. Donnarumma,
Y. Evangelista,
M. Frutti,
I. Lapshov,
F. Lazzarotto,
M. Mastropietro,
E. Morelli,
L. Pacciani,
G. Porrovecchio,
M. Rapisarda,
A. Rubini,
M. Tavani,
A. Argan
Abstract:
SuperAGILE is a coded mask experiment based on silicon microstrip detectors. It operates in the 15-45 keV nominal energy range, providing crossed one-dimensional images of the X-ray sky with an on-axis angular resolution of 6 arcmin, over a field of view in excess of 1 steradian. It was designed as the hard X-ray monitor of the AGILE space mission, a small satellite of the Italian Space Agency d…
▽ More
SuperAGILE is a coded mask experiment based on silicon microstrip detectors. It operates in the 15-45 keV nominal energy range, providing crossed one-dimensional images of the X-ray sky with an on-axis angular resolution of 6 arcmin, over a field of view in excess of 1 steradian. It was designed as the hard X-ray monitor of the AGILE space mission, a small satellite of the Italian Space Agency devoted to image the gamma-ray sky in the 30 MeV - 50 GeV energy band. The AGILE mission was launched in a low-earth orbit on 23^{rd} April 2007. In this paper we describe the SuperAGILE experiment, its construction and test processes, and its performance before flight, based on the on-ground test and calibrations.
△ Less
Submitted 1 August, 2007;
originally announced August 2007.
-
Fast Electronics for the Dafne Transverse Feedback Systems
Authors:
A. Drago,
A. Argan,
M. Serio
Abstract:
Transverse feedback systems for controlling the vertical coupled-bunch instabilities in the positron and electron main rings are installed at DAFNE. They started to be operative respectively from June and September 2000. For the horizontal plane, similar systems have been installed in summer 2001 with less kicker power. Design specifications and the basic system concepts are presented. Real time…
▽ More
Transverse feedback systems for controlling the vertical coupled-bunch instabilities in the positron and electron main rings are installed at DAFNE. They started to be operative respectively from June and September 2000. For the horizontal plane, similar systems have been installed in summer 2001 with less kicker power. Design specifications and the basic system concepts are presented. Real time bunch-by-bunch offset correction is implemented using digital signal processors and dual-port RAM's. Fast analog to digital sampling is performed at the maximum bunch frequency (368 MHz). The system manages at full speed a continuous flow of 8-bits data and it has the capability to invert the sign or put to zero the output for any combination of bunches. A conversion from digital to analog produces the output correcting signal.
△ Less
Submitted 29 November, 2001;
originally announced November 2001.
-
SuperAGILE: the X-ray Monitor of the AGILE gamma-ray Mission
Authors:
M. Feroci,
E. Costa,
E. Del Monte,
I. Lapshov,
M. Mastropietro,
E. Morelli,
M. Rapisarda,
A. Rubini,
P. Soffitta,
G. Barbiellini,
F. Longo,
M. Prest,
E. Vallazza,
A. Argan,
S. Mereghetti,
M. Tavani,
S. Vercellone,
A. Morselli
Abstract:
SuperAGILE is the X-ray stage of the AGILE gamma-ray mission. It is devoted to monitor X-ray (10-40 keV) sources with a sensitivity better than 10 mCrabs in 50 ks and to detect X-ray transients in a field of view of 1.8 sr, well matched to that of the gamma-ray tracker, with few arc-minutes position resolution and better than 5 us timing resolution. SuperAGILE is designed to exploit one addition…
▽ More
SuperAGILE is the X-ray stage of the AGILE gamma-ray mission. It is devoted to monitor X-ray (10-40 keV) sources with a sensitivity better than 10 mCrabs in 50 ks and to detect X-ray transients in a field of view of 1.8 sr, well matched to that of the gamma-ray tracker, with few arc-minutes position resolution and better than 5 us timing resolution. SuperAGILE is designed to exploit one additional layer of four Si microstrip detectors placed on top of the AGILE tracker, and a system of four mutually orthogonal one-dimensional coded masks to encode the X-ray sky. The total geometric area is 1444 cm^2. Low noise electronics based on ASIC technology composes the front-end read out. We present here the instrumental and astrophysical performances of SuperAGILE as derived by analytical calculations, Monte Carlo simulations and experimental tests on a prototype of the silicon microstrip detector and front-end electronics.
△ Less
Submitted 10 January, 2001;
originally announced January 2001.