Tomographic phase and attenuation extraction for a sample composed of unknown materials using X-ray propagation-based phase-contrast imaging
Authors:
Samantha J. Alloo,
David M. Paganin,
Kaye S. Morgan,
Timur E. Gureyev,
Sherry C. Mayo,
Sara Mohammadi,
Darren Lockie,
Ralf Hendrik Menk,
Fulvia Arfelli,
Fabrizio Zanconati,
Giuliana Tromba,
Konstantin M. Pavlov
Abstract:
Propagation-based phase-contrast X-ray imaging (PB-PCXI) generates image contrast by utilizing sample-imposed phase-shifts. This has proven useful when imaging weakly-attenuating samples, as conventional attenuation-based imaging does not always provide adequate contrast. We present a PB-PCXI algorithm capable of extracting the X-ray attenuation, $β$, and refraction, $δ$, components of the complex…
▽ More
Propagation-based phase-contrast X-ray imaging (PB-PCXI) generates image contrast by utilizing sample-imposed phase-shifts. This has proven useful when imaging weakly-attenuating samples, as conventional attenuation-based imaging does not always provide adequate contrast. We present a PB-PCXI algorithm capable of extracting the X-ray attenuation, $β$, and refraction, $δ$, components of the complex refractive index of distinct materials within an unknown sample. The method involves curve-fitting an error-function-based model to a phase-retrieved interface in a PB-PCXI tomographic reconstruction, which is obtained when Paganin-type phase-retrieval is applied with incorrect values of $δ$ and $β$. The fit parameters can then be used to calculate true $δ$ and $β$ values for composite materials. This approach requires no a priori sample information, making it broadly applicable. Our PB-PCXI reconstruction is single distance, requiring only one exposure per tomographic angle, which is important for radiosensitive samples. We apply this approach to a breast-tissue sample, recovering the refraction component, $δ$, with 0.6 - 2.4\% accuracy compared to theoretical values.
△ Less
Submitted 14 October, 2021; v1 submitted 12 October, 2021;
originally announced October 2021.
Monte Carlo Simulation of X-rays Multiple Refractive Scattering from Fine Structure Objects imaged with the DEI Technique
Authors:
A. N. Khromova,
L. Rigon,
F. Arfelli,
R. H. Menk,
H. J. Besch,
H. Plothow-Besch
Abstract:
In this work we present a novel 3D Monte Carlo photon transport program for simulation of multiple refractive scattering based on the refractive properties of X-rays in highly scattering media, like lung tissue. Multiple scattering reduces not only the quality of the image, but contains also information on the internal structure of the object. This information can be exploited utilizing image mo…
▽ More
In this work we present a novel 3D Monte Carlo photon transport program for simulation of multiple refractive scattering based on the refractive properties of X-rays in highly scattering media, like lung tissue. Multiple scattering reduces not only the quality of the image, but contains also information on the internal structure of the object. This information can be exploited utilizing image modalities such as Diffraction Enhanced Imaging (DEI). To study the effect of multiple scattering a Monte Carlo program was developed that simulates multiple refractive scattering of X-ray photons on monodisperse PMMA (poly-methyl-methacrylate) microspheres representing alveoli in lung tissue. Eventually, the results of the Monte Carlo program were compared to the measurements taken at the SYRMEP beamline at Elettra (Trieste, Italy) on special phantoms showing a good agreement between both data.
△ Less
Submitted 1 February, 2010;
originally announced February 2010.
Imaging with high Dynamic using an Ionization Chamber
Authors:
Ralf-Hendrik Menk,
Heinz Amenitsch,
Fulvia Arfelli,
Sigrid Bernstorff,
Hans Juergen Besch,
Francesco Voltolina
Abstract:
In this work a combination of an ionization chamber with one-dimensional spatial resolution and a MicroCAT structure will be presented. The combination between gas gain operations and integrating front-end electronics yields a dynamic range as high as eight to nine orders of magnitude. Therefore this device is well suitable for medical imaging or applications such as small angle x-ray scattering…
▽ More
In this work a combination of an ionization chamber with one-dimensional spatial resolution and a MicroCAT structure will be presented. The combination between gas gain operations and integrating front-end electronics yields a dynamic range as high as eight to nine orders of magnitude. Therefore this device is well suitable for medical imaging or applications such as small angle x-ray scattering, where the requirements on the dynamic of the detector are exceptional high. Basically the described detector is an ionization chamber adapted to fan beam geometry with an active area of 192 cm and a pitch of the anode strips of 150 micrometer. In the vertical direction beams as high as 10 mm can be accepted. Every read-out strip is connected to an analogue integrating electronics channel realized in a custom made VLSI chip. A MicroCAT structure utilized as a shielding grid enables frame rates as high as 10kHz. The high dynamic range observed stems from the fact that the MicroCAT enables active electron amplification in the gas. Thus a single photon resolution can be obtained for low photon fluxes even with the integrating electronics. The specialty of this device is that for each photon flux the gas amplification can be adjusted in such a fashion that the maximum DQE value is achieved.
△ Less
Submitted 31 January, 2010;
originally announced February 2010.