-
Searches for new physics below twice the electron mass with GERDA
Authors:
GERDA Collaboration,
M. Agostini,
A. Alexander,
G. R. Araujo,
A. M. Bakalyarov,
M. Balata,
I. Barabanov,
L. Baudis,
C. Bauer,
S. Belogurov,
A. Bettini,
L. Bezrukov,
V. Biancacci,
E. Bossio,
V. Bothe,
R. Brugnera,
A. Caldwell,
S. Calgaro,
C. Cattadori,
A. Chernogorov,
P. -J. Chiu,
T. Comellato,
V. D'Andrea,
E. V. Demidova,
N. Di Marco
, et al. (86 additional authors not shown)
Abstract:
A search for full energy depositions from bosonic keV-scale dark matter candidates of masses between 65 keV and 1021 keV has been performed with data collected during Phase II of the GERmanium Detector Array (GERDA) experiment. Our analysis includes direct dark matter absorption as well as dark Compton scattering. With a total exposure of 105.5 kg yr, no evidence for a signal above the background…
▽ More
A search for full energy depositions from bosonic keV-scale dark matter candidates of masses between 65 keV and 1021 keV has been performed with data collected during Phase II of the GERmanium Detector Array (GERDA) experiment. Our analysis includes direct dark matter absorption as well as dark Compton scattering. With a total exposure of 105.5 kg yr, no evidence for a signal above the background has been observed. The resulting exclusion limits deduced with either Bayesian or Frequentist statistics are the most stringent direct constraints in the major part of the 140-1021 keV mass range. As an example, at a mass of 150 keV the dimensionless coupling of dark photons and axion-like particles to electrons has been constrained to $α$'/$α$ < 8.7x10$^{-24}$ and g$_{ae}$ < 3.3x10$^{-12}$ at 90% credible interval (CI), respectively. Additionally, a search for peak-like signals from beyond the Standard Model decays of nucleons and electrons is performed. We find for the inclusive decay of a single neutron in $^{76}$Ge a lower lifetime limit of $τ_n$ > 1.5x10$^{24}$ yr and for a proton $τ_p$ > 1.3x10$^{24}$ yr at 90% CI. For the electron decay e$^-\rightarrowν_eγ$ a lower limit of $τ_e$ > 5.4x10$^{25}$ yr at 90% CI has been determined.
△ Less
Submitted 24 May, 2024;
originally announced May 2024.
-
Mineral Detection of Neutrinos and Dark Matter 2024. Proceedings
Authors:
Sebastian Baum,
Patrick Huber,
Patrick Stengel,
Natsue Abe,
Daniel G. Ang,
Lorenzo Apollonio,
Gabriela R. Araujo,
Levente Balogh,
Pranshu Bhaumik Yilda Boukhtouchen,
Joseph Bramante,
Lorenzo Caccianiga,
Andrew Calabrese-Day,
Qing Chang,
Juan I. Collar,
Reza Ebadi,
Alexey Elykov,
Katherine Freese,
Audrey Fung,
Claudio Galelli,
Arianna E. Gleason,
Mariano Guerrero Perez,
Janina Hakenmüller,
Takeshi Hanyu,
Noriko Hasebe,
Shigenobu Hirose
, et al. (35 additional authors not shown)
Abstract:
The second "Mineral Detection of Neutrinos and Dark Matter" (MDvDM'24) meeting was held January 8-11, 2024 in Arlington, VA, USA, hosted by Virginia Tech's Center for Neutrino Physics. This document collects contributions from this workshop, providing an overview of activities in the field. MDvDM'24 was the second topical workshop dedicated to the emerging field of mineral detection of neutrinos a…
▽ More
The second "Mineral Detection of Neutrinos and Dark Matter" (MDvDM'24) meeting was held January 8-11, 2024 in Arlington, VA, USA, hosted by Virginia Tech's Center for Neutrino Physics. This document collects contributions from this workshop, providing an overview of activities in the field. MDvDM'24 was the second topical workshop dedicated to the emerging field of mineral detection of neutrinos and dark matter, following a meeting hosted by IFPU in Trieste, Italy in October 2022. Mineral detectors have been proposed for a wide variety of applications, including searching for dark matter, measuring various fluxes of astrophysical neutrinos over gigayear timescales, monitoring nuclear reactors, and nuclear disarmament protocols; both as paleo-detectors using natural minerals that could have recorded the traces of nuclear recoils for timescales as long as a billion years and as detectors recording nuclear recoil events on laboratory timescales using natural or artificial minerals. Contributions to this proceedings discuss the vast physics potential, the progress in experimental studies, and the numerous challenges lying ahead on the path towards mineral detection. These include a better understanding of the formation and annealing of recoil defects in crystals; identifying the best classes of minerals and, for paleo-detectors, understanding their geology; modeling and control of the relevant backgrounds; develo**, combining, and scaling up imaging and data analysis techniques; and many others. During the last years, MDvDM has grown rapidly and gained attention. Small-scale experimental efforts focused on establishing various microscopic readout techniques are underway at institutions in North America, Europe and Asia. We are looking ahead to an exciting future full of challenges to overcome, surprises to be encountered, and discoveries lying ahead of us.
△ Less
Submitted 2 May, 2024;
originally announced May 2024.
-
The MONUMENT Experiment: Ordinary Muon Capture studies for 0$νββ$ decay
Authors:
Dhanurdhar Bajpai,
Laura Baudis,
Viacheslav Belov,
Elisabetta Bossio,
Thomas E. Cocolios,
Hiroyasu Ejiri,
Evgenii Sushenok,
Maria Fomina,
Izyan H. Hashim,
Michael Heines,
Konstantin Gusev,
Sergej Kazartsev,
Andreas Knecht,
Elizabeth Mondragon,
Ng Zheng Wei,
Faiznur Othman,
Igor Ostrovskiy,
Gabriela R. Araujo,
Nadyia Rumyantseva,
Mario Schwarz,
Stefan Schoenert,
Mark Shirchenko,
Egor Shevchik,
Yury Shitov,
Jouni Suhonen
, et al. (4 additional authors not shown)
Abstract:
The MONUMENT experiment measures ordinary muon capture (OMC) on isotopes relevant for neutrinoless double-beta (0$νββ$) decay and nuclear astrophysics. OMC is a particularly attractive tool for improving the theoretical description of 0$νββ$ decay. It involves similar momentum transfers and allows testing the virtual transitions involved in 0$νββ$ decay against experimental data. During the 2021 c…
▽ More
The MONUMENT experiment measures ordinary muon capture (OMC) on isotopes relevant for neutrinoless double-beta (0$νββ$) decay and nuclear astrophysics. OMC is a particularly attractive tool for improving the theoretical description of 0$νββ$ decay. It involves similar momentum transfers and allows testing the virtual transitions involved in 0$νββ$ decay against experimental data. During the 2021 campaign, MONUMENT measured OMC on $^{76}$Se and $^{136}$Ba, the isotopes relevant for next-generation 0$νββ$ decay searches, like LEGEND and nEXO. The experimental setup has been designed to accurately extract the total and partial muon capture rates, which requires precise reconstruction of energies and time-dependent intensities of the OMC-related $γ$ rays. The setup also includes a veto counter system to allow selecting a clean sample of OMC events. This work provides a detailed description of the MONUMENT setup operated during the 2021 campaign, its two DAQ systems, calibration and analysis approaches, and summarises the achieved detector performance. Future improvements are also discussed.
△ Less
Submitted 19 April, 2024;
originally announced April 2024.
-
An improved limit on the neutrinoless double-electron capture of $^{36}$Ar with GERDA
Authors:
GERDA Collaboration,
M. Agostini,
A. Alexander,
G. R. Araujo,
A. M. Bakalyarov,
M. Balata,
I. Barabanov,
L. Baudis,
C. Bauer,
S. Belogurov,
A. Bettini,
L. Bezrukov,
V. Biancacci,
E. Bossio,
V. Bothe,
V. Brudanin,
R. Brugnera,
A. Caldwell,
C. Cattadori,
A. Chernogorov,
T. Comellato,
V. D'Andrea,
E. V. Demidova,
N. Di Marco,
E. Doroshkevich
, et al. (88 additional authors not shown)
Abstract:
The GERmanium Detector Array (GERDA) experiment operated enriched high-purity germanium detectors in a liquid argon cryostat, which contains 0.33% of $^{36}$Ar, a candidate isotope for the two-neutrino double-electron capture (2$ν$ECEC) and therefore for the neutrinoless double-electron capture (0$ν$ECEC). If detected, this process would give evidence of lepton number violation and the Majorana na…
▽ More
The GERmanium Detector Array (GERDA) experiment operated enriched high-purity germanium detectors in a liquid argon cryostat, which contains 0.33% of $^{36}$Ar, a candidate isotope for the two-neutrino double-electron capture (2$ν$ECEC) and therefore for the neutrinoless double-electron capture (0$ν$ECEC). If detected, this process would give evidence of lepton number violation and the Majorana nature of neutrinos. In the radiative 0$ν$ECEC of $^{36}$Ar, a monochromatic photon is emitted with an energy of 429.88 keV, which may be detected by the GERDA germanium detectors. We searched for the $^{36}$Ar 0$ν$ECEC with GERDA data, with a total live time of 4.34 yr (3.08 yr accumulated during GERDA Phase II and 1.26 yr during GERDA Phase I). No signal was found and a 90% C.L. lower limit on the half-life of this process was established T$_{1/2}$ > 1.5x10$^{22}$ yr
△ Less
Submitted 3 November, 2023;
originally announced November 2023.
-
Final Results of GERDA on the Two-Neutrino Double-$β$ Decay Half-Life of $^{76}$Ge
Authors:
GERDA collaboration,
M. Agostini,
A. Alexander,
G. R. Araujo,
A. M. Bakalyarov,
M. Balata,
I. Barabanov,
L. Baudis,
C. Bauer,
S. Belogurov,
A. Bettini,
L. Bezrukov,
V. Biancacci,
E. Bossio,
V. Bothe,
R. Brugnera,
A. Caldwell,
S. Calgaro,
C. Cattadori,
A. Chernogorov,
P. -J. Chiu,
T. Comellato,
V. D'Andrea,
E. V. Demidova,
A. Di Giacinto
, et al. (94 additional authors not shown)
Abstract:
We present the measurement of the two-neutrino double-$β$ decay rate of $^{76}$Ge performed with the GERDA Phase II experiment. With a subset of the entire GERDA exposure, 11.8 kg$\cdot$yr, the half-life of the process has been determined: $T^{2ν}_{1/2} = (2.022 \pm 0.018_{stat} \pm 0.038_{sys})\times10^{21}$ yr. This is the most precise determination of the $^{76}$Ge two-neutrino double-$β$ decay…
▽ More
We present the measurement of the two-neutrino double-$β$ decay rate of $^{76}$Ge performed with the GERDA Phase II experiment. With a subset of the entire GERDA exposure, 11.8 kg$\cdot$yr, the half-life of the process has been determined: $T^{2ν}_{1/2} = (2.022 \pm 0.018_{stat} \pm 0.038_{sys})\times10^{21}$ yr. This is the most precise determination of the $^{76}$Ge two-neutrino double-$β$ decay half-life and one of the most precise measurements of a double-$β$ decay process. The relevant nuclear matrix element can be extracted: $M^{2ν}_{\text{eff}} = (0.101\pm0.001).$
△ Less
Submitted 18 August, 2023;
originally announced August 2023.
-
Precision Measurement of the Specific Activity of $^{39}$Ar in Atmospheric Argon with the DEAP-3600 Detector
Authors:
P. Adhikari,
R. Ajaj,
M. Alpízar-Venegas,
P. -A. Amaudruz,
J. Anstey,
G. R. Araujo,
D. J. Auty,
M. Baldwin,
M. Batygov,
B. Beltran,
H. Benmansour,
C. E. Bina,
J. Bonatt,
W. Bonivento,
M. G. Boulay,
B. Broerman,
J. F. Bueno,
P. M. Burghardt,
A. Butcher,
M. Cadeddu,
B. Cai,
M. Cárdenas-Montes,
S. Cavuoti,
M. Chen,
Y. Chen
, et al. (125 additional authors not shown)
Abstract:
The specific activity of the beta decay of $^{39}$Ar in atmospheric argon is measured using the DEAP-3600 detector. DEAP-3600, located 2 km underground at SNOLAB, uses a total of (3269 $\pm$ 24) kg of liquid argon distilled from the atmosphere to search for dark matter. This detector with very low background uses pulseshape discrimination to differentiate between nuclear recoils and electron recoi…
▽ More
The specific activity of the beta decay of $^{39}$Ar in atmospheric argon is measured using the DEAP-3600 detector. DEAP-3600, located 2 km underground at SNOLAB, uses a total of (3269 $\pm$ 24) kg of liquid argon distilled from the atmosphere to search for dark matter. This detector with very low background uses pulseshape discrimination to differentiate between nuclear recoils and electron recoils and is well-suited to measure the decay of $^{39}$Ar. With 167 live-days of data, the measured specific activity at the time of atmospheric extraction is [0.964 $\pm$ 0.001 (stat) $\pm$ 0.024 (sys)] Bq/kg$_{\rm atmAr}$ which is consistent with results from other experiments. A cross-check analysis using different event selection criteria provides a consistent result.
△ Less
Submitted 10 October, 2023; v1 submitted 27 February, 2023;
originally announced February 2023.
-
Mineral Detection of Neutrinos and Dark Matter. A Whitepaper
Authors:
Sebastian Baum,
Patrick Stengel,
Natsue Abe,
Javier F. Acevedo,
Gabriela R. Araujo,
Yoshihiro Asahara,
Frank Avignone,
Levente Balogh,
Laura Baudis,
Yilda Boukhtouchen,
Joseph Bramante,
Pieter Alexander Breur,
Lorenzo Caccianiga,
Francesco Capozzi,
Juan I. Collar,
Reza Ebadi,
Thomas Edwards,
Klaus Eitel,
Alexey Elykov,
Rodney C. Ewing,
Katherine Freese,
Audrey Fung,
Claudio Galelli,
Ulrich A. Glasmacher,
Arianna Gleason
, et al. (44 additional authors not shown)
Abstract:
Minerals are solid state nuclear track detectors - nuclear recoils in a mineral leave latent damage to the crystal structure. Depending on the mineral and its temperature, the damage features are retained in the material from minutes (in low-melting point materials such as salts at a few hundred degrees C) to timescales much larger than the 4.5 Gyr-age of the Solar System (in refractory materials…
▽ More
Minerals are solid state nuclear track detectors - nuclear recoils in a mineral leave latent damage to the crystal structure. Depending on the mineral and its temperature, the damage features are retained in the material from minutes (in low-melting point materials such as salts at a few hundred degrees C) to timescales much larger than the 4.5 Gyr-age of the Solar System (in refractory materials at room temperature). The damage features from the $O(50)$ MeV fission fragments left by spontaneous fission of $^{238}$U and other heavy unstable isotopes have long been used for fission track dating of geological samples. Laboratory studies have demonstrated the readout of defects caused by nuclear recoils with energies as small as $O(1)$ keV. This whitepaper discusses a wide range of possible applications of minerals as detectors for $E_R \gtrsim O(1)$ keV nuclear recoils: Using natural minerals, one could use the damage features accumulated over $O(10)$ Myr$-O(1)$ Gyr to measure astrophysical neutrino fluxes (from the Sun, supernovae, or cosmic rays interacting with the atmosphere) as well as search for Dark Matter. Using signals accumulated over months to few-years timescales in laboratory-manufactured minerals, one could measure reactor neutrinos or use them as Dark Matter detectors, potentially with directional sensitivity. Research groups in Europe, Asia, and America have started develo** microscopy techniques to read out the $O(1) - O(100)$ nm damage features in crystals left by $O(0.1) - O(100)$ keV nuclear recoils. We report on the status and plans of these programs. The research program towards the realization of such detectors is highly interdisciplinary, combining geoscience, material science, applied and fundamental physics with techniques from quantum information and Artificial Intelligence.
△ Less
Submitted 16 May, 2023; v1 submitted 17 January, 2023;
originally announced January 2023.
-
Liquid argon light collection and veto modeling in GERDA Phase II
Authors:
GERDA collaboration,
M. Agostini,
A. Alexander,
G. R. Araujo,
A. M. Bakalyarov,
M. Balata,
I. Barabanov,
L. Baudis,
C. Bauer,
S. Belogurov,
A. Bettini,
L. Bezrukov,
V. Biancacci,
E. Bossio,
V. Bothe,
R. Brugnera,
A. Caldwell,
S. Calgaro,
C. Cattadori,
A. Chernogorov,
P-J. Chiu,
T. Comellato,
V. D'Andrea,
E. V. Demidova,
A. Di Giacinto
, et al. (94 additional authors not shown)
Abstract:
The ability to detect liquid argon scintillation light from within a densely packed high-purity germanium detector array allowed the GERDA experiment to reach an exceptionally low background rate in the search for neutrinoless double beta decay of $^{76}$Ge. Proper modeling of the light propagation throughout the experimental setup, from any origin in the liquid argon volume to its eventual detect…
▽ More
The ability to detect liquid argon scintillation light from within a densely packed high-purity germanium detector array allowed the GERDA experiment to reach an exceptionally low background rate in the search for neutrinoless double beta decay of $^{76}$Ge. Proper modeling of the light propagation throughout the experimental setup, from any origin in the liquid argon volume to its eventual detection by the novel light read-out system, provides insight into the rejection capability and is a necessary ingredient to obtain robust background predictions. In this paper, we present a model of the GERDA liquid argon veto, as obtained by Monte Carlo simulations and constrained by calibration data, and highlight its application for background decomposition.
△ Less
Submitted 6 December, 2022;
originally announced December 2022.
-
The upgraded low-background germanium counting facility Gator for high-sensitivity $γ$-ray spectrometry
Authors:
G. R. Araujo,
L. Baudis,
Y. Biondi,
A. Bismark,
M. Galloway
Abstract:
We describe the upgrade and performance of the high-purity germanium counting facility Gator, which is dedicated to low-background $γ$-ray spectrometry. Gator is operated at the Gran Sasso Underground Laboratory in Italy, at an average depth of 3600 meter water equivalent, and employed for material screening and selection in ultra-low background, rare-event search experiments in astroparticle phys…
▽ More
We describe the upgrade and performance of the high-purity germanium counting facility Gator, which is dedicated to low-background $γ$-ray spectrometry. Gator is operated at the Gran Sasso Underground Laboratory in Italy, at an average depth of 3600 meter water equivalent, and employed for material screening and selection in ultra-low background, rare-event search experiments in astroparticle physics. The detector is equipped with a passive shield made of layers of copper, lead and polyethylene, and the sample cavity is purged with gaseous nitrogen maintained at positive pressure for radon suppression. After upgrading its enclosure, the background rate is (82.0$\pm$0.7) counts/(kg$\cdot$day) in the energy region 100 keV to 2700 keV, a 20% reduction compared to the previously reported rate. We show the stability of various operation parameters as a function of time. We also summarize the sample analysis procedure, and demonstrate Gator's sensitivity by examining one material sample, a candidate photosensor for the DARWIN experiment.
△ Less
Submitted 5 July, 2022; v1 submitted 26 April, 2022;
originally announced April 2022.
-
Passive low energy nuclear recoil detection with color centers -- PALEOCCENE
Authors:
Krystal Alfonso,
Gabriela R. Araujo,
Laura Baudis,
Nathaniel Bowden,
Bernadette K. Cogswell,
Anna Erickson,
Michelle Galloway,
Adam A. Hecht,
Rathsara R. H. Herath Mudiyanselage,
Patrick Huber,
Igor Jovanovic,
Giti A. Khodaparast,
Brenden A. Magill,
Thomas O'Donnell,
Nicholas W. G. Smith,
Xianyi Zhang
Abstract:
The PALEOCCENE concept offers the potential for room-temperature, passive and robust detectors in the gram to kilogram range for the detection of low-energy nuclear recoil events. Nuclear recoil events can be caused by neutron scattering, coherent elastic neutrino nucleus scattering (CEvNS) or dark matter scattering and therefore, PALEOCCENE could find applications in all three areas. In this whit…
▽ More
The PALEOCCENE concept offers the potential for room-temperature, passive and robust detectors in the gram to kilogram range for the detection of low-energy nuclear recoil events. Nuclear recoil events can be caused by neutron scattering, coherent elastic neutrino nucleus scattering (CEvNS) or dark matter scattering and therefore, PALEOCCENE could find applications in all three areas. In this white paper we present current and planned R&D efforts to study the feasibility of this technique.
△ Less
Submitted 10 March, 2022;
originally announced March 2022.
-
Ultraviolet-induced fluorescence of poly(methyl methacrylate) compared to 1,1,4,4-tetraphenyl-1,3-butadiene down to 4 K
Authors:
E. Ellingwood,
H. Benmansour,
Q. Hars,
J. Hucker,
V. Pereimak,
J. M. Corning,
P. Perrin,
G. R. Araujo,
P. C. F. Di Stefano,
M. Kuźniak,
T. R. Pollmann,
M. Hamel,
M. G. Boulay,
B. Cai,
D. Gallacher,
A. Kemp,
J. Mason,
P. Skensved,
M. Stringer
Abstract:
Several particle-physics experiments use poly(methyl methacrylate) (a.k.a. PMMA or acrylic) vessels to contain liquid scintillators. Superluminal charged particles emitted from radioactive impurities in or near the acrylic can emit Cherenkov radiation in the ultraviolet (UV) spectra range. If acrylic fluoresces in the visible range due to this UV light, it could be a source of background in experi…
▽ More
Several particle-physics experiments use poly(methyl methacrylate) (a.k.a. PMMA or acrylic) vessels to contain liquid scintillators. Superluminal charged particles emitted from radioactive impurities in or near the acrylic can emit Cherenkov radiation in the ultraviolet (UV) spectra range. If acrylic fluoresces in the visible range due to this UV light, it could be a source of background in experiments where the main signal is visible scintillation light, or UV scintillation light that is absorbed and re-emitted at visible wavelengths by a wavelength shifter. Some of these experiments operate at low temperature. The fluorescence of these materials could change with temperature so we have studied the fluorescence of the acrylic used in the DEAP-3600 experiment down to a temperature of 4 K, and compared it to the common wavelength shifter 1,1,4,4-tetraphenyl-1,3-butadiene (TPB). The light yield and wavelength spectra of these materials were characterized by exciting the sample with 285 nm UV light which acted as a proxy for Cherenkov light in the detector. Spectral measurements indicate at least part of the fluorescence of the acrylic is due to additives. Time-resolved measurements show the light yields of our acrylic sample, TPB sample, and the relative light between both samples, all increase when cooling down. At room temperature, the light yield of our acrylic sample relative to the TPB sample is 0.3 %, while it reaches 0.5 % at 4 K. The main fluorescence time constant of the acrylic is less than a few nanoseconds.
△ Less
Submitted 21 December, 2021;
originally announced December 2021.
-
R&D of Wavelength-Shifting Reflectors and Characterization of the Quantum Efficiency of Tetraphenyl Butadiene and Polyethylene Naphthalate in Liquid Argon
Authors:
G. R. Araujo,
L. Baudis,
N. McFadden,
P. Krause,
S. Schönert,
V. H. S. Wu
Abstract:
Detectors based on liquid argon (LAr) often require surfaces that can shift vacuum ultraviolet (VUV) light and reflect the visible shifted light. For the LAr instrumentation of the LEGEND-200 neutrinoless double beta decay experiment, several square meters of wavelength-shifting reflectors (WLSR) were prepared: the reflector Tetratex (TTX) was in-situ evaporated with the wavelength shifter tetraph…
▽ More
Detectors based on liquid argon (LAr) often require surfaces that can shift vacuum ultraviolet (VUV) light and reflect the visible shifted light. For the LAr instrumentation of the LEGEND-200 neutrinoless double beta decay experiment, several square meters of wavelength-shifting reflectors (WLSR) were prepared: the reflector Tetratex (TTX) was in-situ evaporated with the wavelength shifter tetraphenyl butadiene (TPB). For even larger detectors, TPB evaporation will be more challenging and plastic films of polyethylene naphthalate (PEN) are considered as an option to ease scalability.
In this work, we first characterized the absorption (and reflectivity) of PEN, TPB (and TTX) films in response to visible light. We then measured TPB and PEN coupled to TTX in a LAr setup equipped with a VUV sensitive photomultiplier tube. The effective light yield in the setup was first measured using an absorbing reference sample, and the VUV reflectivity of TTX quantified. The characterization and simulation of the setup along with the measurements and modelling of the optical parameters of TPB, PEN and TTX allowed to estimate the quantum efficiency (QE) of TPB and PEN in LAr (at 87K) for the first time: these were found to be above 67% and 49%, respectively (at 90% CL). These results provide relevant input for the optical simulations of experiments that use TPB in LAr, such as LEGEND-200, and for experiments that plan to use TPB or PEN to shift VUV scintillation light.
△ Less
Submitted 14 May, 2022; v1 submitted 13 December, 2021;
originally announced December 2021.
-
LEGEND-1000 Preconceptual Design Report
Authors:
LEGEND Collaboration,
N. Abgrall,
I. Abt,
M. Agostini,
A. Alexander,
C. Andreoiu,
G. R. Araujo,
F. T. Avignone III,
W. Bae,
A. Bakalyarov,
M. Balata,
M. Bantel,
I. Barabanov,
A. S. Barabash,
P. S. Barbeau,
C. J. Barton,
P. J. Barton,
L. Baudis,
C. Bauer,
E. Bernieri,
L. Bezrukov,
K. H. Bhimani,
V. Biancacci,
E. Blalock,
A. Bolozdynya
, et al. (239 additional authors not shown)
Abstract:
We propose the construction of LEGEND-1000, the ton-scale Large Enriched Germanium Experiment for Neutrinoless $ββ$ Decay. This international experiment is designed to answer one of the highest priority questions in fundamental physics. It consists of 1000 kg of Ge detectors enriched to more than 90% in the $^{76}$Ge isotope operated in a liquid argon active shield at a deep underground laboratory…
▽ More
We propose the construction of LEGEND-1000, the ton-scale Large Enriched Germanium Experiment for Neutrinoless $ββ$ Decay. This international experiment is designed to answer one of the highest priority questions in fundamental physics. It consists of 1000 kg of Ge detectors enriched to more than 90% in the $^{76}$Ge isotope operated in a liquid argon active shield at a deep underground laboratory. By combining the lowest background levels with the best energy resolution in the field, LEGEND-1000 will perform a quasi-background-free search and can make an unambiguous discovery of neutrinoless double-beta decay with just a handful of counts at the decay $Q$ value. The experiment is designed to probe this decay with a 99.7%-CL discovery sensitivity in the $^{76}$Ge half-life of $1.3\times10^{28}$ years, corresponding to an effective Majorana mass upper limit in the range of 9-21 meV, to cover the inverted-ordering neutrino mass scale with 10 yr of live time.
△ Less
Submitted 23 July, 2021;
originally announced July 2021.
-
Probing the screening of the Casimir interaction with optical tweezers
Authors:
L. B. Pires,
D. S. Ether,
B. Spreng,
G. R. S. Araújo,
R. S. Decca,
R. S. Dutra,
M. Borges,
F. S. S. Rosa,
G. -L. Ingold,
M. J. B. Moura,
S. Frases,
B. Pontes,
H. M. Nussenzveig,
S. Reynaud,
N. B. Viana,
P. A. Maia Neto
Abstract:
We measure the colloidal interaction between two silica microspheres in aqueous solution in the distance range from $0.2\,μ$m to $0.5\,μ$m with the help of optical tweezers. When employing a sample with a low salt concentration, the resulting interaction is dominated by the repulsive double-layer interaction which is fully characterized. The double-layer interaction is suppressed when adding…
▽ More
We measure the colloidal interaction between two silica microspheres in aqueous solution in the distance range from $0.2\,μ$m to $0.5\,μ$m with the help of optical tweezers. When employing a sample with a low salt concentration, the resulting interaction is dominated by the repulsive double-layer interaction which is fully characterized. The double-layer interaction is suppressed when adding $0.22\,$M of salt to our sample, thus leading to a purely attractive Casimir signal. When analyzing the experimental data for the potential energy and force, we find good agreement with theoretical results based on the scattering approach. At the distance range probed experimentally, the interaction arises mainly from the unscreened transverse magnetic contribution in the zero-frequency limit, with nonzero Matsubara frequencies providing a negligible contribution. In contrast, such unscreened contribution is not included by the standard theoretical model of the Casimir interaction in electrolyte solutions, in which the zero-frequency term is treated separately as an electrostatic fluctuational effect. As a consequence, the resulting attraction is too weak in this standard model, by approximately one order of magnitude, to explain the experimental data. Overall, our experimental results shed light on the nature of the thermal zero-frequency contribution and indicate that the Casimir attraction across polar liquids has a longer range than previously predicted.
△ Less
Submitted 24 June, 2021; v1 submitted 31 March, 2021;
originally announced April 2021.
-
Characterization of inverted coaxial $^{76}$Ge detectors in GERDA for future double-$β$ decay experiments
Authors:
GERDA collaboration,
M. Agostini,
G. R. Araujo,
A. M. Bakalyarov,
M. Balata,
I. Barabanov,
L. Baudis,
C. Bauer,
E. Bellotti,
S. Belogurov,
A. Bettini,
L. Bezrukov,
V. Biancacci,
E. Bossio,
V. Bothe,
V. Brudanin,
R. Brugnera,
A. Caldwell,
C. Cattadori,
A. Chernogorov,
T. Comellato,
V. D'Andrea,
E. V. Demidova,
N. Di Marco,
E. Doroshkevich
, et al. (86 additional authors not shown)
Abstract:
Neutrinoless double-$β$ decay of $^{76}$Ge is searched for with germanium detectors where source and detector of the decay are identical. For the success of future experiments it is important to increase the mass of the detectors. We report here on the characterization and testing of five prototype detectors manufactured in inverted coaxial (IC) geometry from material enriched to 88% in $^{76}$Ge.…
▽ More
Neutrinoless double-$β$ decay of $^{76}$Ge is searched for with germanium detectors where source and detector of the decay are identical. For the success of future experiments it is important to increase the mass of the detectors. We report here on the characterization and testing of five prototype detectors manufactured in inverted coaxial (IC) geometry from material enriched to 88% in $^{76}$Ge. IC detectors combine the large mass of the traditional semi-coaxial Ge detectors with the superior resolution and pulse shape discrimination power of point contact detectors which exhibited so far much lower mass. Their performance has been found to be satisfactory both when operated in vacuum cryostat and bare in liquid argon within the GERDA setup. The measured resolutions at the Q-value for double-$β$ decay of $^{76}$Ge (Q$_{ββ}$ = 2039 keV) are about 2.1 keV full width at half maximum in vacuum cryostat. After 18 months of operation within the ultra-low background environment of the GERmanium Detector Array (GERDA) experiment and an accumulated exposure of 8.5 kg$\cdot$yr, the background index after analysis cuts is measured to be $4.9^{+7.3}_{-3.4}\times 10^{-4}$ counts /(keV$\cdot$kg$\cdot$yr) around Q$_{ββ}$. This work confirms the feasibility of IC detectors for the next-generation experiment LEGEND.
△ Less
Submitted 28 March, 2021;
originally announced March 2021.
-
Calibration of the GERDA experiment
Authors:
GERDA collaboration,
M. Agostini,
G. R. Araujo,
A. M. Bakalyarov,
M. Balata,
I. Barabanov,
L. Baudis,
C. Bauer,
E. Bellotti,
S. Belogurov,
A. Bettini,
L. Bezrukov,
V. Biancacci,
E. Bossio,
V. Bothe,
V. Brudanin,
R. Brugnera,
A. Caldwell,
C. Cattadori,
A. Chernogorov,
T. Comellato,
V. D'Andrea,
E. V. Demidova,
N. Di Marco,
E. Doroshkevich
, et al. (87 additional authors not shown)
Abstract:
The GERmanium Detector Array (GERDA) collaboration searched for neutrinoless double-$β$ decay in $^{76}$Ge with an array of about 40 high-purity isotopically-enriched germanium detectors. The experimental signature of the decay is a monoenergetic signal at Q$_{ββ}$ = 2039.061(7)keV in the measured summed energy spectrum of the two emitted electrons. Both the energy reconstruction and resolution of…
▽ More
The GERmanium Detector Array (GERDA) collaboration searched for neutrinoless double-$β$ decay in $^{76}$Ge with an array of about 40 high-purity isotopically-enriched germanium detectors. The experimental signature of the decay is a monoenergetic signal at Q$_{ββ}$ = 2039.061(7)keV in the measured summed energy spectrum of the two emitted electrons. Both the energy reconstruction and resolution of the germanium detectors are crucial to separate a potential signal from various backgrounds, such as neutrino-accompanied double-$β$ decays allowed by the Standard Model. The energy resolution and stability were determined and monitored as a function of time using data from regular $^{228}$Th calibrations. In this work, we describe the calibration process and associated data analysis of the full GERDA dataset, tailored to preserve the excellent resolution of the individual germanium detectors when combining data over several years.
△ Less
Submitted 25 March, 2021;
originally announced March 2021.
-
Final Results of GERDA on the Search for Neutrinoless Double-$β$ Decay
Authors:
GERDA collaboration,
M. Agostini,
G. R. Araujo,
A. M. Bakalyarov,
M. Balata,
I. Barabanov,
L. Baudis,
C. Bauer,
E. Bellotti,
S. Belogurov,
A. Bettini,
L. Bezrukov,
V. Biancacci,
D. Borowicz,
E. Bossio,
V. Bothe,
V. Brudanin,
R. Brugnera,
A. Caldwell,
C. Cattadori,
A. Chernogorov,
T. Comellato,
V. D'Andrea,
E. V. Demidova,
N. Di Marco
, et al. (90 additional authors not shown)
Abstract:
The GERmanium Detector Array (GERDA) experiment searched for the lepton-number-violating neutrinoless double-$β$ ($0νββ$) decay of $^{76}$Ge, whose discovery would have far-reaching implications in cosmology and particle physics. By operating bare germanium diodes, enriched in $^{76}$Ge, in an active liquid argon shield, GERDA achieved an unprecedently low background index of $5.2\times10^{-4}$ co…
▽ More
The GERmanium Detector Array (GERDA) experiment searched for the lepton-number-violating neutrinoless double-$β$ ($0νββ$) decay of $^{76}$Ge, whose discovery would have far-reaching implications in cosmology and particle physics. By operating bare germanium diodes, enriched in $^{76}$Ge, in an active liquid argon shield, GERDA achieved an unprecedently low background index of $5.2\times10^{-4}$ counts/(keV$\cdot$kg$\cdot$yr) in the signal region and met the design goal to collect an exposure of 100 kg$\cdot$yr in a background-free regime. When combined with the result of Phase I, no signal is observed after 127.2 kg$\cdot$yr of total exposure. A limit on the half-life of $0νββ$ decay in $^{76}$Ge is set at $T_{1/2}>1.8\times10^{26}$ yr at 90% C.L., which coincides with the sensitivity assuming no signal.
△ Less
Submitted 13 September, 2020;
originally announced September 2020.
-
Temperature-dependent fluorescence emission spectra of acrylic (PMMA) and tetraphenyl butadiene (TPB) excited with UV light
Authors:
J. M. Corning,
G. R. Araujo,
P. C. F. Di Stefano,
V. Pereymak,
T. Pollmann,
P. Skensved
Abstract:
Acrylic (poly(methyl methacrylate) or PMMA) is commonly used as a vessel to hold scintillating liquids in rare-event searches. Certain types of PMMA can fluoresce with a low efficiency at room temperature. We have investigated the fluorescence spectra under 280nm ultraviolet (UV) excitation of the PMMA used in the DEAP dark matter search at various low temperatures. Fluorescence of this PMMA is ob…
▽ More
Acrylic (poly(methyl methacrylate) or PMMA) is commonly used as a vessel to hold scintillating liquids in rare-event searches. Certain types of PMMA can fluoresce with a low efficiency at room temperature. We have investigated the fluorescence spectra under 280nm ultraviolet (UV) excitation of the PMMA used in the DEAP dark matter search at various low temperatures. Fluorescence of this PMMA is observed, with an increasing intensity as the sample is cooled from a temperature of 300K down to 4K. The common wavelength-shifter tetraphenyl butadiene (TPB) is also measured for use as a reference.
△ Less
Submitted 4 December, 2019;
originally announced December 2019.
-
Electromagnetic Backgrounds and Potassium-42 Activity in the DEAP-3600 Dark Matter Detector
Authors:
R. Ajaj,
G. R. Araujo,
M. Batygov,
B. Beltran,
C. E. Bina,
M. G. Boulay,
B. Broerman,
J. F. Bueno,
P. M. Burghardt,
A. Butcher,
M. Cárdenas-Montes,
S. Cavuoti,
M. Chen,
Y. Chen,
B. T. Cleveland,
K. Dering,
F. A. Duncan,
M. Dunford,
A. Erlandson,
N. Fatemighomi,
G. Fiorillo,
A. Flower,
R. J. Ford,
D. Gallacher,
P. García Abia
, et al. (66 additional authors not shown)
Abstract:
The DEAP-3600 experiment is searching for WIMP dark matter with a 3.3 tonne single phase liquid argon (LAr) target, located 2.1 km underground at SNOLAB. The experimental signature of dark matter interactions is keV-scale $^{40}$Ar nuclear recoils (NR) producing 128 nm LAr scintillation photons observed by PMTs. The largest backgrounds in DEAP-3600 are electronic recoils (ER) induced by $β$ and…
▽ More
The DEAP-3600 experiment is searching for WIMP dark matter with a 3.3 tonne single phase liquid argon (LAr) target, located 2.1 km underground at SNOLAB. The experimental signature of dark matter interactions is keV-scale $^{40}$Ar nuclear recoils (NR) producing 128 nm LAr scintillation photons observed by PMTs. The largest backgrounds in DEAP-3600 are electronic recoils (ER) induced by $β$ and $γ$-rays originating from internal and external radioactivity in the detector material. A background model of the ER interactions in DEAP-3600 was developed and is described in this work. The model is based on several components which are expected from radioisotopes in the LAr, from ex-situ material assay measurements, and from dedicated independent in-situ analyses. This prior information is used in a Bayesian fit of the ER components to a 247.2 d dataset to model the radioactivity in the surrounding detector materials. While excellent discrimination between ERs and NRs is reached with pulse shape discrimination, utilizing the large difference between fast and slow components of LAr scintillation light, detailed knowledge of the ER background and activity of detector components, sets valuable constraints on other key types of backgrounds in the detector: neutrons and alphas. In addition, the activity of $^{42}$Ar in LAr in DEAP-3600 is determined by measuring the daughter decay of $^{42}$K. This cosmogenically activated trace isotope is a relevant background at higher energies for other rare event searches using atmospheric argon e.g. DarkSide-20k, GERDA or LEGEND. The specific activity of $^{42}$Ar in the atmosphere is found to be $40.4 \pm 5.9$ $μ$Bq/kg of argon.
△ Less
Submitted 14 May, 2019;
originally announced May 2019.
-
Photoluminescence response of acrylic (PMMA) and polytetrafluoroethylene (PTFE) to ultraviolet light
Authors:
G. R. Araujo,
T. Pollmann,
A. Ulrich
Abstract:
Some publications indicate that poly(methyl methacrylate) (PMMA) and polytetrafluoroethylene (PTFE) exhibit low levels of photoluminesence (fluorescence and/or phosphorescence) when irradiated with photons in the ultraviolet (UV) to visible range. PMMA (also known as acrylic) and PTFE are commonly used to contain the liquid argon (LAr) or xenon (LXe) target material in rare-event search experiment…
▽ More
Some publications indicate that poly(methyl methacrylate) (PMMA) and polytetrafluoroethylene (PTFE) exhibit low levels of photoluminesence (fluorescence and/or phosphorescence) when irradiated with photons in the ultraviolet (UV) to visible range. PMMA (also known as acrylic) and PTFE are commonly used to contain the liquid argon (LAr) or xenon (LXe) target material in rare-event search experiments. LAr and LXe scintillate in the vacuum UV region, and the PMMA and PTFE can be directly illuminated by these photons. Photoluminescence from support materials could cause unexpected signals in these detectors.
We investigate photoluminesence in the 400 nm to 550 nm region in response to excitation with UV light between 130 nm and 250 nm at levels relevant to rare-event search experiments. Measurements are done at room temperature and the signal intensity is time-integrated over several minutes.
We tested PMMA and PTFE samples from the batches used in the DEAP-3600 and LUX experiments and observed no photoluminescence signal. We put limits on the efficiency of the plastics to shift UV photons to a wavelengths region of 400 nm to 550 nm at 0.05% to 0.35% relative to the wavelength shifting efficiency of tetraphenyl-butadiene.
△ Less
Submitted 20 May, 2019; v1 submitted 8 May, 2019;
originally announced May 2019.
-
Search for dark matter with a 231-day exposure of liquid argon using DEAP-3600 at SNOLAB
Authors:
R. Ajaj,
P. -A. Amaudruz,
G. R. Araujo,
M. Baldwin,
M. Batygov,
B. Beltran,
C. E. Bina,
J. Bonatt,
M. G. Boulay,
B. Broerman,
J. F. Bueno,
P. M. Burghardt,
A. Butcher,
B. Cai,
S. Cavuoti,
M. Chen,
Y. Chen,
B. T. Cleveland,
D. Cranshaw,
K. Dering,
J. DiGioseffo,
L. Doria,
F. A. Duncan,
M. Dunford,
A. Erlandson
, et al. (77 additional authors not shown)
Abstract:
DEAP-3600 is a single-phase liquid argon (LAr) direct-detection dark matter experiment, operating 2 km underground at SNOLAB (Sudbury, Canada). The detector consists of 3279 kg of LAr contained in a spherical acrylic vessel. This paper reports on the analysis of a 758 tonne\cdot day exposure taken over a period of 231 live-days during the first year of operation. No candidate signal events are obs…
▽ More
DEAP-3600 is a single-phase liquid argon (LAr) direct-detection dark matter experiment, operating 2 km underground at SNOLAB (Sudbury, Canada). The detector consists of 3279 kg of LAr contained in a spherical acrylic vessel. This paper reports on the analysis of a 758 tonne\cdot day exposure taken over a period of 231 live-days during the first year of operation. No candidate signal events are observed in the WIMP-search region of interest, which results in the leading limit on the WIMP-nucleon spin-independent cross section on a LAr target of $3.9\times10^{-45}$ cm$^{2}$ ($1.5\times10^{-44}$ cm$^{2}$) for a 100 GeV/c$^{2}$ (1 TeV/c$^{2}$) WIMP mass at 90\% C. L. In addition to a detailed background model, this analysis demonstrates the best pulse-shape discrimination in LAr at threshold, employs a Bayesian photoelectron-counting technique to improve the energy resolution and discrimination efficiency, and utilizes two position reconstruction algorithms based on PMT charge and photon arrival times.
△ Less
Submitted 4 July, 2019; v1 submitted 11 February, 2019;
originally announced February 2019.
-
Polyethylene naphthalate film as a wavelength shifter in liquid argon detectors
Authors:
M. Kuźniak,
B. Broerman,
T. Pollmann,
G. R. Araujo
Abstract:
Liquid argon-based scintillation detectors are important for dark matter searches and neutrino physics. Argon scintillation light is in the vacuum ultraviolet region, making it hard to be detected by conventional means. Polyethylene naphthalate (PEN), an optically transparent thermoplastic polyester commercially available as large area sheets or rolls, is proposed as an alternative wavelength shif…
▽ More
Liquid argon-based scintillation detectors are important for dark matter searches and neutrino physics. Argon scintillation light is in the vacuum ultraviolet region, making it hard to be detected by conventional means. Polyethylene naphthalate (PEN), an optically transparent thermoplastic polyester commercially available as large area sheets or rolls, is proposed as an alternative wavelength shifter to the commonly-used tetraphenyl butadiene (TPB). By combining the existing literature data and spectrometer measurements relative to TPB, we conclude that the fluorescence yield and timing of both materials may be very close. The evidence collected suggests that PEN is a suitable replacement for TPB in liquid argon neutrino detectors, and is also a promising candidate for dark matter detectors. Advantages of PEN are discussed in the context of scaling-up existing technologies to the next generation of very large ktonne-scale detectors. Its simplicity has a potential to facilitate such scale-ups, revolutionizing the field.
△ Less
Submitted 15 March, 2019; v1 submitted 11 June, 2018;
originally announced June 2018.
-
DarkSide-50 532-day Dark Matter Search with Low-Radioactivity Argon
Authors:
The DarkSide Collaboration,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
G. R. Araujo,
M. Ave,
H. O. Back,
B. Baldin,
G. Batignani,
K. Biery,
V. Bocci,
G. Bonfini,
W. Bonivento,
B. Bottino,
F. Budano,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
A. Caminata,
N. Canci,
A. Candela,
M. Caravati,
M. Cariello
, et al. (150 additional authors not shown)
Abstract:
The DarkSide-50 direct-detection dark matter experiment is a dual-phase argon time projection chamber operating at Laboratori Nazionali del Gran Sasso. This paper reports on the blind analysis of a (16,660+-270) kg d exposure using a target of low-radioactivity argon extracted from underground sources. We find no events in the dark matter selection box and set a 90% C.L. upper limit on the dark ma…
▽ More
The DarkSide-50 direct-detection dark matter experiment is a dual-phase argon time projection chamber operating at Laboratori Nazionali del Gran Sasso. This paper reports on the blind analysis of a (16,660+-270) kg d exposure using a target of low-radioactivity argon extracted from underground sources. We find no events in the dark matter selection box and set a 90% C.L. upper limit on the dark matter-nucleon spin-independent cross section of 1.14E-44 cm^2 (3.78E-44 cm^2, 3.43E-43 cm^2) for a WIMP mass of 100 GeV/c^2 (1 TeV/c^2, 10 TeV/c^2).
△ Less
Submitted 19 November, 2018; v1 submitted 20 February, 2018;
originally announced February 2018.
-
Constraints on Sub-GeV Dark Matter-Electron Scattering from the DarkSide-50 Experiment
Authors:
The DarkSide Collaboration,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
G. R. Araujo,
D. M. Asner,
M. Ave,
H. O. Back,
B. Baldin,
G. Batignani,
K. Biery,
V. Bocci,
G. Bonfini,
W. Bonivento,
B. Bottino,
F. Budano,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
A. Caminata,
N. Canci,
A. Candela,
M. Caravati
, et al. (171 additional authors not shown)
Abstract:
We present new constraints on sub-GeV dark matter particles scattering off electrons in argon based on an analysis of ionization signal data from the DarkSide-50 detector.
We present new constraints on sub-GeV dark matter particles scattering off electrons in argon based on an analysis of ionization signal data from the DarkSide-50 detector.
△ Less
Submitted 3 October, 2018; v1 submitted 20 February, 2018;
originally announced February 2018.
-
Low-Mass Dark Matter Search with the DarkSide-50 Experiment
Authors:
The DarkSide Collaboration,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
G. R. Araujo,
D. M. Asner,
M. Ave,
H. O. Back,
B. Baldin,
G. Batignani,
K. Biery,
V. Bocci,
G. Bonfini,
W. Bonivento,
B. Bottino,
F. Budano,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
A. Caminata,
N. Canci,
A. Candela,
M. Caravati
, et al. (170 additional authors not shown)
Abstract:
We present the results of a search for dark matter WIMPs in the mass range below 20 GeV/c^2 using a target of low-radioactivity argon. The data were obtained using the DarkSide-50 apparatus at Laboratori Nazionali del Gran Sasso (LNGS). The analysis is based on the ionization signal, for which the DarkSide-50 time projection chamber is fully efficient at 0.1 keVee. The observed rate in the detecto…
▽ More
We present the results of a search for dark matter WIMPs in the mass range below 20 GeV/c^2 using a target of low-radioactivity argon. The data were obtained using the DarkSide-50 apparatus at Laboratori Nazionali del Gran Sasso (LNGS). The analysis is based on the ionization signal, for which the DarkSide-50 time projection chamber is fully efficient at 0.1 keVee. The observed rate in the detector at 0.5 keVee is about 1.5 events/keVee/kg/day and is almost entirely accounted for by known background sources. We obtain a 90% C.L. exclusion limit above 1.8 GeV/c^2 for the spin-independent cross section of dark matter WIMPs on nucleons, extending the exclusion region for dark matter below previous limits in the range 1.8-6 GeV/c^2.
△ Less
Submitted 28 August, 2018; v1 submitted 20 February, 2018;
originally announced February 2018.
-
Probing the Casimir force with optical tweezers
Authors:
D. S. Ether Jr,
L. B. Pires,
S. Umrath,
D. Martinez,
Y. Ayala,
B. Pontes,
G. R. de S. Araújo,
S. Frases,
G. -L. Ingold,
F. S. S. Rosa,
N. B. Viana,
H. M. Nussenzveig,
P. A. Maia Neto
Abstract:
We propose to use optical tweezers to probe the Casimir interaction between microspheres inside a liquid medium for geometric aspect ratios far beyond the validity of the widely employed proximity force approximation. This setup has the potential for revealing unprecedented features associated to the non-trivial role of the spherical curvatures. For a proof of concept, we measure femtonewton doubl…
▽ More
We propose to use optical tweezers to probe the Casimir interaction between microspheres inside a liquid medium for geometric aspect ratios far beyond the validity of the widely employed proximity force approximation. This setup has the potential for revealing unprecedented features associated to the non-trivial role of the spherical curvatures. For a proof of concept, we measure femtonewton double layer forces between polystyrene microspheres at distances above $400$ nm by employing very soft optical tweezers, with stiffness of the order of fractions of a fN/nm. As a future application, we propose to tune the Casimir interaction between a metallic and a polystyrene microsphere in saline solution from attraction to repulsion by varying the salt concentration. With those materials, the screened Casimir interaction may have a larger magnitude than the unscreened one. This line of investigation has the potential for bringing together different fields including classical and quantum optics, statistical physics and colloid science, while paving the way for novel quantitative applications of optical tweezers in cell and molecular biology.
△ Less
Submitted 6 November, 2015;
originally announced November 2015.