Relativistic ultrafast electron diffraction at high repetition rates
Authors:
K. M. Siddiqui,
D. B. Durham,
F. Cropp,
F. Ji,
S. Paiagua,
C. Ophus,
N. C. Andresen,
L. **,
J. Wu,
S. Wang,
X. Zhang,
W. You,
M. Murnane,
M. Centurion,
X. Wang,
D. S. Slaughter,
R. A. Kaindl,
P. Musumeci,
A. M. Minor,
D. Filippetto
Abstract:
The ability to resolve the dynamics of matter on its native temporal and spatial scales constitutes a key challenge and convergent theme across chemistry, biology, and materials science. The last couple of decades have witnessed ultrafast electron diffraction (UED) emerge as one of the forefront techniques with the sensitivity to resolve atomic motions. Increasingly sophisticated UED instruments a…
▽ More
The ability to resolve the dynamics of matter on its native temporal and spatial scales constitutes a key challenge and convergent theme across chemistry, biology, and materials science. The last couple of decades have witnessed ultrafast electron diffraction (UED) emerge as one of the forefront techniques with the sensitivity to resolve atomic motions. Increasingly sophisticated UED instruments are being developed that are aimed at increasing the beam brightness in order to observe structural signatures, but so far they have been limited to low average current beams. Here we present the technical design and capabilities of the HiRES (High Repetition Rate Electron Scattering) instrument, which blends relativistic electrons and high repetition rates to achieve orders of magnitude improvement in average beam current compared to the existing state-of-the-art UED instruments. The setup utilizes a novel electron source to deliver femtosecond duration electron pulses at up to MHz repetition rates for UED experiments. We provide example cases of diffraction measurements on solid-state and gas-phase samples, including both micro- and nanodiffraction modes, which showcase the potential of the instrument for novel UED experiments.
△ Less
Submitted 7 June, 2023;
originally announced June 2023.
-
Steady state cyclic behaviour of a half-plane contact in partial slip subject to varying normal load, moment, shear load, and moderate differential bulk tension
Authors:
H. N. Andresen,
D. A. Hills,
J. R. Barber,
J. Vázquez
Abstract:
A new solution for a general half-plane contact in the steady state is presented. The contacting bodies are subject to a set of constant loads - normal force, shear force and bulk tension parallel with the interface - together with an oscillatory set of the same quantities. Partial slip conditions are expected to ensue for a range of these quantities. In addition, the line of action of the normal…
▽ More
A new solution for a general half-plane contact in the steady state is presented. The contacting bodies are subject to a set of constant loads - normal force, shear force and bulk tension parallel with the interface - together with an oscillatory set of the same quantities. Partial slip conditions are expected to ensue for a range of these quantities. In addition, the line of action of the normal load component does not necessarily need to pass the centre-line of the contact, thereby introducing a moment and asymmetry in the contact extent. This advancement enables a map** to be formalised between the normal and tangential problem. An exact and easy to apply recipe is defined.
△ Less
Submitted 13 August, 2019;
originally announced August 2019.
-
Performance of the LBNL FastCCD for the European XFEL
Authors:
Friederike Januschek,
Ivana Klackova,
Nord Andresen,
Peter Denes,
Steffen Hauf,
John Joseph,
Markus Kuster,
Craig Tindall
Abstract:
The European X-ray Free Electron Laser (XFEL.EU) is currently being commissioned in Schenefeld, Germany. From 2017 onwards it will provide spatially coherent X-rays of energies between 0.25\,keV and 25\,keV with a unique timing structure. One of the detectors foreseen at XFEL.EU for the soft X-ray regime (energies below 6\,keV) is a quasi column-parallel readout FastCCD developed by Lawrence Berke…
▽ More
The European X-ray Free Electron Laser (XFEL.EU) is currently being commissioned in Schenefeld, Germany. From 2017 onwards it will provide spatially coherent X-rays of energies between 0.25\,keV and 25\,keV with a unique timing structure. One of the detectors foreseen at XFEL.EU for the soft X-ray regime (energies below 6\,keV) is a quasi column-parallel readout FastCCD developed by Lawrence Berkeley National Lab (LBNL) specifically for the XFEL.EU requirements. Its sensor has 1920$\times$960 pixels of 30\,$μ$m $\times$30\,$μ$m size with a beam hole in the middle of the sensor. The camera can be operated in full frame and frame store mode. With the FastCCD a frame rate of up to 120~fps can be achieved, but at XFEL.EU the camera settings are optimized for the 10\,Hz XFEL bunch-mode. The detector has been delivered to XFEL.EU. Results of the performance tests and calibration done using the XFEL.EU detector calibration infrastructure are presented quantifying noise level, gain and energy resolution.
△ Less
Submitted 12 December, 2016;
originally announced December 2016.
-
A high-efficiency spin-resolved phototemission spectrometer combining time-of-flight spectroscopy with exchange-scattering polarimetry
Authors:
C. Jozwiak,
J. Graf,
G. Lebedev,
N. Andresen,
A. K. Schmid,
A. V. Fedorov,
F. El Gabaly,
W. Wan,
A. Lanzara,
Z. Hussain
Abstract:
We describe a spin-resolved electron spectrometer capable of uniquely efficient and high energy resolution measurements. Spin analysis is obtained through polarimetry based on low-energy exchange scattering from a ferromagnetic thin-film target. This approach can achieve a similar analyzing power (Sherman function) as state-of-the-art Mott scattering polarimeters, but with as much as 100 times imp…
▽ More
We describe a spin-resolved electron spectrometer capable of uniquely efficient and high energy resolution measurements. Spin analysis is obtained through polarimetry based on low-energy exchange scattering from a ferromagnetic thin-film target. This approach can achieve a similar analyzing power (Sherman function) as state-of-the-art Mott scattering polarimeters, but with as much as 100 times improved efficiency due to increased reflectivity. Performance is further enhanced by integrating the polarimeter into a time-of-flight (TOF) based energy analysis scheme with a precise and flexible electrostatic lens system. The parallel acquisition of a range of electron kinetic energies afforded by the TOF approach results in an order of magnitude (or more) increase in efficiency compared to hemispherical analyzers. The lens system additionally features a 90° bandpass filter, which by removing unwanted parts of the photoelectron distribution allows the TOF technique to be performed at low electron drift energy and high energy resolution within a wide range of experimental parameters. The spectrometer is ideally suited for high-resolution spin- and angle-resolved photoemission spectroscopy (spin-ARPES), and initial results are shown. The TOF approach makes the spectrometer especially ideal for time-resolved spin-ARPES experiments.
△ Less
Submitted 10 June, 2010;
originally announced June 2010.