-
Intermodulation spectroscopy and the nonlinear response of two-level systems in superconducting coplanar waveguide resonators
Authors:
Janka Biznárová,
J. C. Rivera Hernández,
Daniel Forchheimer,
Jonas Bylander,
David B. Haviland,
Gustav Andersson
Abstract:
Two-level system (TLS) loss is typically limiting the coherence of superconducting quantum circuits. The loss induced by TLS defects is nonlinear, resulting in quality factors with a strong dependence on the circulating microwave power. We observe frequency mixing due to this nonlinearity by applying a two-tone drive to a coplanar waveguide resonator and measuring the intermodulation products usin…
▽ More
Two-level system (TLS) loss is typically limiting the coherence of superconducting quantum circuits. The loss induced by TLS defects is nonlinear, resulting in quality factors with a strong dependence on the circulating microwave power. We observe frequency mixing due to this nonlinearity by applying a two-tone drive to a coplanar waveguide resonator and measuring the intermodulation products using a multifrequency lock-in technique. This intermodulation spectroscopy method provides an efficient approach to characterizing TLS loss in superconducting circuits. Using harmonic balance reconstruction, we recover the nonlinear parameters of the device-TLS interaction, which are in good agreement with the standard tunnelling model for TLSs.
△ Less
Submitted 16 February, 2024;
originally announced February 2024.
-
Bidirectional multi-photon communication between remote superconducting nodes
Authors:
Joel Grebel,
Haoxiong Yan,
Ming-Han Chou,
Gustav Andersson,
Christopher R. Conner,
Yash J. Joshi,
Jacob M. Miller,
Rhys G. Povey,
Hong Qiao,
Xuntao Wu,
Andrew N. Cleland
Abstract:
Quantum communication testbeds provide a useful resource for experimentally investigating a variety of communication protocols. Here we demonstrate a superconducting circuit testbed with bidirectional multi-photon state transfer capability using time-domain shaped wavepackets. The system we use to achieve this comprises two remote nodes, each including a tunable superconducting transmon qubit and…
▽ More
Quantum communication testbeds provide a useful resource for experimentally investigating a variety of communication protocols. Here we demonstrate a superconducting circuit testbed with bidirectional multi-photon state transfer capability using time-domain shaped wavepackets. The system we use to achieve this comprises two remote nodes, each including a tunable superconducting transmon qubit and a tunable microwave-frequency resonator, linked by a 2 m-long superconducting coplanar waveguide, which serves as a transmission line. We transfer both individual and superposition Fock states between the two remote nodes, and additionally show that this bidirectional state transfer can be done simultaneously, as well as used to entangle elements in the two nodes.
△ Less
Submitted 29 September, 2023;
originally announced October 2023.
-
Two-dimensional optomechanical crystal resonator in gallium arsenide
Authors:
Rhys G. Povey,
Ming-Han Chou,
Gustav Andersson,
Christopher R. Conner,
Joel Grebel,
Yash J. Joshi,
Jacob M. Miller,
Hong Qiao,
Xuntao Wu,
Haoxiong Yan,
Andrew N. Cleland
Abstract:
In the field of quantum computation and communication there is a compelling need for quantum-coherent frequency conversion between microwave electronics and infra-red optics. A promising platform for this is an optomechanical crystal resonator that uses simultaneous photonic and phononic crystals to create a co-localized cavity coupling an electromagnetic mode to an acoustic mode, which then via e…
▽ More
In the field of quantum computation and communication there is a compelling need for quantum-coherent frequency conversion between microwave electronics and infra-red optics. A promising platform for this is an optomechanical crystal resonator that uses simultaneous photonic and phononic crystals to create a co-localized cavity coupling an electromagnetic mode to an acoustic mode, which then via electromechanical interactions can undergo direct transduction to electronics. The majority of work in this area has been on one-dimensional nanobeam resonators which provide strong optomechanical couplings but, due to their geometry, suffer from an inability to dissipate heat produced by the laser pum** required for operation. Recently, a quasi-two-dimensional optomechanical crystal cavity was developed in silicon exhibiting similarly strong coupling with better thermalization, but at a mechanical frequency above optimal qubit operating frequencies. Here we adapt this design to gallium arsenide, a natural thin-film single-crystal piezoelectric that can incorporate electromechanical interactions, obtaining a mechanical resonant mode at f_m ~ 4.5 GHz ideal for superconducting qubits, and demonstrating optomechanical coupling g_om/(2pi) ~ 650 kHz.
△ Less
Submitted 26 July, 2023;
originally announced July 2023.
-
Broadband Bandpass Purcell Filter for Circuit Quantum Electrodynamics
Authors:
Haoxiong Yan,
Xuntao Wu,
Andrew Lingenfelter,
Yash J. Joshi,
Gustav Andersson,
Christopher R. Conner,
Ming-Han Chou,
Joel Grebel,
Jacob M. Miller,
Rhys G. Povey,
Hong Qiao,
Aashish A. Clerk,
Andrew N. Cleland
Abstract:
In circuit quantum electrodynamics (QED), qubits are typically measured using dispersively-coupled readout resonators. Coupling between each readout resonator and its electrical environment however reduces the qubit lifetime via the Purcell effect. Inserting a Purcell filter counters this effect while maintaining high readout fidelity, but reduces measurement bandwidth and thus limits multiplexing…
▽ More
In circuit quantum electrodynamics (QED), qubits are typically measured using dispersively-coupled readout resonators. Coupling between each readout resonator and its electrical environment however reduces the qubit lifetime via the Purcell effect. Inserting a Purcell filter counters this effect while maintaining high readout fidelity, but reduces measurement bandwidth and thus limits multiplexing readout capacity. In this letter, we develop and implement a multi-stage bandpass Purcell filter that yields better qubit protection while simultaneously increasing measurement bandwidth and multiplexed capacity. We report on the experimental performance of our transmission-line--based implementation of this approach, a flexible design that can easily be integrated with current scaled-up, long coherence time superconducting quantum processors.
△ Less
Submitted 18 July, 2023; v1 submitted 9 June, 2023;
originally announced June 2023.
-
Develo** a platform for linear mechanical quantum computing
Authors:
Hong Qiao,
Etienne Dumur,
Gustav Andersson,
Haoxiong Yan,
Ming-Han Chou,
Joel Grebel,
Christopher R. Conner,
Yash J. Joshi,
Jacob M. Miller,
Rhys G. Povey,
Xuntao Wu,
Andrew N. Cleland
Abstract:
Linear optical quantum computing provides a desirable approach to quantum computing, with a short list of required elements. The similarity between photons and phonons points to the interesting potential for linear mechanical quantum computing (LMQC), using phonons in place of photons. While single-phonon sources and detectors have been demonstrated, a phononic beamsplitter element remains an outs…
▽ More
Linear optical quantum computing provides a desirable approach to quantum computing, with a short list of required elements. The similarity between photons and phonons points to the interesting potential for linear mechanical quantum computing (LMQC), using phonons in place of photons. While single-phonon sources and detectors have been demonstrated, a phononic beamsplitter element remains an outstanding requirement. Here we demonstrate such an element, using two superconducting qubits to fully characterize a beamsplitter with single phonons. We further use the beamsplitter to demonstrate two-phonon interference, a requirement for two-qubit gates, completing the toolbox needed for LMQC. This advance brings linear quantum computing to a fully solid-state system, along with straightforward conversion between itinerant phonons and superconducting qubits.
△ Less
Submitted 15 February, 2023;
originally announced February 2023.
-
Correlated frequency noise in a multimode acoustic resonator
Authors:
Nuttamas Tubsrinuan,
Jared H. Cole,
Per Delsing,
Gustav Andersson
Abstract:
Frequency instabilities are a major source of errors in quantum devices. This study investigates frequency fluctuations in a surface acoustic wave (SAW) resonator, where reflection coefficients of 14 SAW modes are measured simultaneously for more than seven hours. We report two distinct noise characteristics. Multimode frequency noise caused by interactions with two-level system (TLS) defects show…
▽ More
Frequency instabilities are a major source of errors in quantum devices. This study investigates frequency fluctuations in a surface acoustic wave (SAW) resonator, where reflection coefficients of 14 SAW modes are measured simultaneously for more than seven hours. We report two distinct noise characteristics. Multimode frequency noise caused by interactions with two-level system (TLS) defects shows significant degrees of correlations that diminish with increased detuning. This finding agrees with the current understanding of the parasitic TLS behavior as one of the dominant noise sources in quantum devices. In addition to the TLS-induced noise, we observe strong anomalous frequency fluctuations with slow, anti-correlated dynamics. These noise bursts resemble signatures of cosmic radiation observed in superconducting quantum systems.
△ Less
Submitted 28 May, 2024; v1 submitted 29 August, 2022;
originally announced August 2022.
-
Direct Hydrogen Production from Water/Seawater by Irradiation/Vibration-Activated Using Defective Ferroelectric BaTiO3-x Nanoparticles
Authors:
Yue Jiang,
Cui Ying Toe,
Sajjad S. Mofarah,
Claudio Cazorla,
Shery L. Y. Chang,
Yanting Yin,
Qi Zhang,
Sean Lim,
Yin Yao,
Ruoming Tian,
Yuan Wang,
Tasmia Zaman,
Hamidreza Arandiyan,
Gunther G. Andersson,
Jason Scott,
Pramod Koshy,
Danyang Wang,
Charles C. Sorrell
Abstract:
Hydrogen is a promising fossil-fuel alternative fuel owing to its environmentally neutral emissions and high energy density. However, the need for purified water and external power are critical hindrances to implementation of hydrogen production. The present work reveals the potential to overcome these shortcomings through piezo-photocatalysis of seawater using BaTiO3-x (BTO) nanoparticles. This m…
▽ More
Hydrogen is a promising fossil-fuel alternative fuel owing to its environmentally neutral emissions and high energy density. However, the need for purified water and external power are critical hindrances to implementation of hydrogen production. The present work reveals the potential to overcome these shortcomings through piezo-photocatalysis of seawater using BaTiO3-x (BTO) nanoparticles. This material was made piezoelectrically active by annealing under different atmospheres, including O2, N2, Ar, and H2, the latter of which caused Ti4+ to Ti(4-x)+ multiple reductions and structural expansions that stabilized piezoelectric tetragonal BTO domains. The resultant defect equilibria combine ionic and electron effects, including Ti redox reactions, charge-compensating surface oxygen vacancy formation, and color centre alterations. Further, variety of experimental techniques revealed the effects of reduction on the energy band structure. A strong piezoelectric effect and the presence of self-polarization were confirmed by piezoresponse force microscopy, while simulation work clarified the role of vibration on band bending deriving from the former. The performance data contrasted H2 evolution using deionized (DI) water, simulated seawater, and natural seawater subjected to photocatalysis, piezocatalysis, and piezo-photocatalysis. An efficient H2 evolution rate of 132.4 micromol/g/h was achieved from DI water using piezo-photocatalysis for 5 h. In contrast, piezocatalysis for 2 h followed by piezo-photocatalysis for 3 h resulted in H2 evolution rates of 100.7 micromol/g/h for DI water, 63.4 micromol/g/h for simulated seawater, and 48.7 micromol/g/h for natural seawater. This work provides potential new strategies for large-scale green H2 production using abundant natural resources with conventional piezoelectric material while leveraging the effects of ions dissolved in seawater.
△ Less
Submitted 29 June, 2022;
originally announced June 2022.
-
Multipartite entanglement in a microwave frequency comb
Authors:
Shan W. Jolin,
Gustav Andersson,
J. C. Rivera Hernández,
Ingrid Strandberg,
Fernando Quijandría,
Joe Aumentado,
Riccardo Borgani,
Mats O. Tholén,
David B. Haviland
Abstract:
Significant progress has been made with multipartite entanglement of discrete qubits, but continuous variable systems may provide a more scalable path toward entanglement of large ensembles. We demonstrate multipartite entanglement in a microwave frequency comb generated by a Josephson parametric amplifier subject to a bichromatic pump. We find 64 correlated modes in the transmission line using a…
▽ More
Significant progress has been made with multipartite entanglement of discrete qubits, but continuous variable systems may provide a more scalable path toward entanglement of large ensembles. We demonstrate multipartite entanglement in a microwave frequency comb generated by a Josephson parametric amplifier subject to a bichromatic pump. We find 64 correlated modes in the transmission line using a multifrequency digital signal processing platform. Full inseparability is verified in a subset of seven modes. Our method can be expanded to generate even more entangled modes in the near future.
△ Less
Submitted 27 March, 2023; v1 submitted 22 December, 2021;
originally announced December 2021.
-
Giant spin-orbit torque efficiency in all-epitaxial heterostructures
Authors:
Nilamani Behera,
Rahul Gupta,
Sajid Husain,
Jitendra Saha,
Rajasekhar Pothala,
Vineet Barwal,
Vireshwar Mishra,
Gabriella Andersson,
Dinesh K. Pandya,
Sujeet Chaudhary,
Rimantas Brucas,
Peter Svedlindh,
Ankit Kumar
Abstract:
A large anti-dam** spin-obit torque (SOT) efficiency in magnetic heterostructures is a prerequisite to realize energy efficient spin torque based magnetic memories and logic devices. The efficiency can be characterized in terms of the spin-orbit fields generated by anti-dam** torques when an electric current is passed through the non-magnetic layer. We report a giant spin-orbit field of 48.96…
▽ More
A large anti-dam** spin-obit torque (SOT) efficiency in magnetic heterostructures is a prerequisite to realize energy efficient spin torque based magnetic memories and logic devices. The efficiency can be characterized in terms of the spin-orbit fields generated by anti-dam** torques when an electric current is passed through the non-magnetic layer. We report a giant spin-orbit field of 48.96 (27.50) mT at an applied current density of 1 MAcm-2 in beta-W interfaced Co60Fe40 (Ni81Fe19)/TiN epitaxial structures due to an anti-dam** like torque, which results in a magnetization auto-oscillation current density as low as 1.68(3.27) MAcm-2. The spin-orbit field value increases with decrease of beta-W layer thickness, which affirms that epitaxial surface states are responsible for the extraordinary large efficiency. SOT induced energy efficient in-plane magnetization switching in large 20x100 um2 structures has been demonstrated by Kerr microscopy and the findings are supported by results from micromagnetic simulations. The observed giant SOT efficiencies in the studied all-epitaxial heterostructures are comparable to values reported for topological insulators. These results confirm that by utilizing epitaxial material combinations an extraordinary large SOT efficiency can be achieved using semiconducting industry compatible 5d heavy metals, which provides immediate solutions for the realization of energy efficient spin-logic devices.
△ Less
Submitted 19 April, 2021;
originally announced April 2021.
-
Squeezing and multimode entanglement of surface acoustic wave phonons
Authors:
Gustav Andersson,
Shan W. Jolin,
Marco Scigliuzzo,
Riccardo Borgani,
Mats O. Tholén,
J. C. Rivera Hernández,
Vitaly Shumeiko,
David B. Haviland,
Per Delsing
Abstract:
Exploiting multiple modes in a quantum acoustic device could enable applications in quantum information in a hardware-efficient setup, including quantum simulation in a synthetic dimension and continuous-variable quantum computing with cluster states.We develop a multimode surface acoustic wave (SAW) resonator with a superconducting quantum interference device (SQUID) integrated in one of the Brag…
▽ More
Exploiting multiple modes in a quantum acoustic device could enable applications in quantum information in a hardware-efficient setup, including quantum simulation in a synthetic dimension and continuous-variable quantum computing with cluster states.We develop a multimode surface acoustic wave (SAW) resonator with a superconducting quantum interference device (SQUID) integrated in one of the Bragg reflectors. The interaction with the SQUID-shunted mirror gives rise to coupling between the more than 20 accessible resonator modes. We exploit this coupling to demonstrate two-mode squeezing of SAW phonons, as well as four-mode multipartite entanglement. Our results open avenues for continuous-variable quantum computing in a compact hybrid quantum system.
△ Less
Submitted 11 February, 2022; v1 submitted 11 July, 2020;
originally announced July 2020.
-
An Uncertainty Management Framework for Integrated Gas-Electric Energy Systems
Authors:
Line A. Roald,
Kaarthik Sundar,
Anatoly Zlotnik,
Sidhant Misra,
Göran Andersson
Abstract:
In many parts of the world, electric power systems have seen a significant shift towards generation from renewable energy and natural gas. Because of their ability to flexibly adjust power generation in real time, gas-fired power plants are frequently seen as the perfect partner for variable renewable generation. However, this reliance on gas generation increases interdependence and propagates unc…
▽ More
In many parts of the world, electric power systems have seen a significant shift towards generation from renewable energy and natural gas. Because of their ability to flexibly adjust power generation in real time, gas-fired power plants are frequently seen as the perfect partner for variable renewable generation. However, this reliance on gas generation increases interdependence and propagates uncertainty between power grids and gas pipelines, and brings coordination and uncertainty management challenges. To address these issues, we propose an uncertainty management framework for uncertain, but bounded gas consumption by gas-fired power plants. The admissible ranges are computed based on a joint optimization problem for the combined gas and electricity networks, which involves chance-constrained scheduling for the electric grid and a novel robust optimization formulation for the natural gas network. This formulation ensures feasibility of the integrated system with a high probability, while providing a tractable numerical formulation. A key advance with respect to existing methods is that our method is based on a physically accurate, validated model for transient gas pipeline flows. Our case study benchmarks our proposed formulation against methods that ignore how reserve activation impacts the fuel use of gas power plants, and only consider predetermined gas consumption. The results demonstrate the importance of considering uncertainty to avoid operating constraint violations and curtailment of gas to the generators.
△ Less
Submitted 25 June, 2020;
originally announced June 2020.
-
Acoustic spectral hole-burning in a two-level system ensemble
Authors:
Gustav Andersson,
André Luiz Oliveira Bilobran,
Marco Scigliuzzo,
Mauricio M. de Lima,
Jared H. Cole,
Per Delsing
Abstract:
Microscopic two-level system (TLS) defects at dielectric surfaces and interfaces are among the dominant sources of loss in superconducting quantum circuits, and their properties have been extensively probed using superconducting resonators and qubits. We report on spectroscopy of TLSs coupling to the strain field in a surface acoustic wave (SAW) resonator. The narrow free spectral range of the res…
▽ More
Microscopic two-level system (TLS) defects at dielectric surfaces and interfaces are among the dominant sources of loss in superconducting quantum circuits, and their properties have been extensively probed using superconducting resonators and qubits. We report on spectroscopy of TLSs coupling to the strain field in a surface acoustic wave (SAW) resonator. The narrow free spectral range of the resonator allows for two-tone spectroscopy where a strong pump is applied at one resonance while a weak signal is used to probe a different mode. We map the spectral hole burnt by the pump tone as a function of frequency and extract parameters of the TLS ensemble. Our results suggest that detuned acoustic pum** can be used to enhance the coherence of superconducting devices by saturating TLSs.
△ Less
Submitted 6 December, 2021; v1 submitted 21 February, 2020;
originally announced February 2020.
-
Magnetic and all-optical switching properties of amorphous Tb$_x$Co$_{100-x}$ alloys
Authors:
Agne Ciuciulkaite,
Kshiti Mishra,
Marcos V. Moro,
Ioan-Augustin Chioar,
Richard M. Rowan-Robinson,
Sergii Parchenko,
Armin Kleibert,
Bengt Lindgren,
Gabriella Andersson,
Carl Davies,
Alexey Kimel,
Marco Berritta,
Peter M. Oppeneer,
Andrei Kirilyuk,
Vassilios Kapaklis
Abstract:
Amorphous Tb$_{x}$Co$_{100-x}$ magnetic alloys exhibit a list of intriguing properties, such as perpendicular magnetic anisotropy, high magneto-optical activity and magnetization switching using ultrashort optical pulses. Varying the Tb:Co ratio in these alloys allows for tuning properties such as the saturation magnetic moment, coercive field and the performance of the light-induced magnetization…
▽ More
Amorphous Tb$_{x}$Co$_{100-x}$ magnetic alloys exhibit a list of intriguing properties, such as perpendicular magnetic anisotropy, high magneto-optical activity and magnetization switching using ultrashort optical pulses. Varying the Tb:Co ratio in these alloys allows for tuning properties such as the saturation magnetic moment, coercive field and the performance of the light-induced magnetization switching. In this work, we investigate the magnetic, optical and magneto-optical properties of various Tb$_{x}$Co$_{100-x}$ thin film alloy compositions. We report on the effect the choice of different seeding layers has on the structural and magnetic properties of Tb$_{x}$Co$_{100-x}$ layers. We also demonstrate that for a range of alloys, deposited on fused silica substrates, with Tb content of 24-30 at.$\%$, helicity dependent all-optical switching of magnetization can be achieved, albeit in a multi-shot framework. We explain this property to arise from the helicity-dependent laser induced magnetization on the Co sublattice due to the inverse Faraday effect. Our study provides an insight into material aspects for future potential hybrid magneto-plasmonic TbCo-based architectures.
△ Less
Submitted 2 October, 2020; v1 submitted 18 February, 2020;
originally announced February 2020.
-
Electromagnetically induced acoustic transparency with a superconducting circuit
Authors:
Gustav Andersson,
Maria K. Ekström,
Per Delsing
Abstract:
We report the observation of Electromagnetically Induced Transparency (EIT) of a mechanical field, where a superconducting artificial atom is coupled to a 1D-transmission line for surface acoustic waves. An electromagnetic microwave drive is used as the control field, rendering the superconducting transmon qubit transparent to the acoustic probe beam. The strong frequency dependence of the acousti…
▽ More
We report the observation of Electromagnetically Induced Transparency (EIT) of a mechanical field, where a superconducting artificial atom is coupled to a 1D-transmission line for surface acoustic waves. An electromagnetic microwave drive is used as the control field, rendering the superconducting transmon qubit transparent to the acoustic probe beam. The strong frequency dependence of the acoustic coupling enables EIT in a ladder configuration due to the suppressed relaxation of the upper level. Our results show that superconducting circuits can be engineered to interact with acoustic fields in parameter regimes not readily accessible to purely electromagnetic systems.
△ Less
Submitted 23 June, 2020; v1 submitted 2 December, 2019;
originally announced December 2019.
-
Towards phonon routing: Controlling propagating acoustic waves in the quantum regime
Authors:
M K Ekström,
T Aref,
A Ask,
G Andersson,
B Suri,
H Sanada,
G Johansson,
P Delsing
Abstract:
We explore routing of propagating phonons in analogy with previous experiments on photons. Surface acoustic waves (SAWs) in the microwave regime are scattered by a superconducting transmon qubit. The transmon can be tuned on or off resonance with the incident SAW field using an external magnetic field or the Autler-Townes effect, and thus the reflection and transmission of the SAW field can be con…
▽ More
We explore routing of propagating phonons in analogy with previous experiments on photons. Surface acoustic waves (SAWs) in the microwave regime are scattered by a superconducting transmon qubit. The transmon can be tuned on or off resonance with the incident SAW field using an external magnetic field or the Autler-Townes effect, and thus the reflection and transmission of the SAW field can be controlled in time. We observe 80% extinction in the transmission of the low power continuous signal and a 40 ns rise time of the router. The slow propagation speed of SAWs on solid surfaces allows for in-flight manipulations of the propagating phonons. The ability to route short, 100 ns, pulses enables new functionality, for instance to catch an acoustic phonon between two qubits and then release it in a controlled direction.
△ Less
Submitted 16 September, 2019;
originally announced September 2019.
-
Nonexponential decay of a giant artificial atom
Authors:
Gustav Andersson,
Baladitya Suri,
Lingzhen Guo,
Thomas Aref,
Per Delsing
Abstract:
In quantum optics, light-matter interaction has conventionally been studied using small atoms interacting with electromagnetic fields with wavelength several orders of magnitude larger than the atomic dimensions. In contrast, here we experimentally demonstrate the vastly different giant atom regime, where an artificial atom interacts with acoustic fields with wavelength several orders of magnitude…
▽ More
In quantum optics, light-matter interaction has conventionally been studied using small atoms interacting with electromagnetic fields with wavelength several orders of magnitude larger than the atomic dimensions. In contrast, here we experimentally demonstrate the vastly different giant atom regime, where an artificial atom interacts with acoustic fields with wavelength several orders of magnitude smaller than the atomic dimensions. This is achieved by coupling a superconducting qubit to surface acoustic waves at two points with separation on the order of 100 wavelengths. This approach is comparable to controlling the radiation of an atom by attaching it to an antenna. The slow velocity of sound leads to a significant internal time-delay for the field to propagate across the giant atom, giving rise to non-Markovian dynamics. We demonstrate the non-Markovian character of the giant atom in the frequency spectrum as well as nonexponential relaxation in the time domain.
△ Less
Submitted 31 March, 2020; v1 submitted 4 December, 2018;
originally announced December 2018.
-
SSCU: an R/Bioconductor package for analyzing selective profile in synonymous codon usage
Authors:
Yu Sun,
Siv G. E. Andersson
Abstract:
Background Synonymous codon choice is mainly affected by mutation and selection. For the majority of genes within a genome, mutational pressure is the major driving force, but selective strength can be strong and dominant for specific set of genes or codons. More specifically, the selective strength on translational efficiency and accuracy increases with the gene's expression level. Many statistic…
▽ More
Background Synonymous codon choice is mainly affected by mutation and selection. For the majority of genes within a genome, mutational pressure is the major driving force, but selective strength can be strong and dominant for specific set of genes or codons. More specifically, the selective strength on translational efficiency and accuracy increases with the gene's expression level. Many statistical approaches have been developed to evaluate and quantify the selective profile in codon usage, including S index and Akashi's test, but no program or pipeline has been developed that includes these tests and automates the calculation.
Results In this study, we release an R package SSCU (selective strength for codon usage, v2.4.0), which includes tools for codon usage analyses. The package identifies optimal codons using two approaches (comparative and correlative methods), implements well-established statistics for detecting codon selection, such as S index, Akashi's test, and estimates standard genomic statistics, such as genomic GC3, RSCU and Nc.
Conclusions The package is useful for researchers working on the codon usage analysis, and thus has general interest to the biological research community. The package is deposited and curated at the Bioconductor site, and has currently been downloaded for more than 2000 times and ranked as top 50% packages.
△ Less
Submitted 22 August, 2018;
originally announced August 2018.
-
Chance-Constrained AC Optimal Power Flow: Reformulations and Efficient Algorithms
Authors:
Line Roald,
Göran Andersson
Abstract:
Higher levels of renewable electricity generation increase uncertainty in power system operation. To ensure secure system operation, new tools that account for this uncertainty are required. In this paper, we formulate a chance-constrained AC optimal power flow problem, which guarantees that generation, power flows and voltages remain within their bounds with a pre-defined probability. We then pro…
▽ More
Higher levels of renewable electricity generation increase uncertainty in power system operation. To ensure secure system operation, new tools that account for this uncertainty are required. In this paper, we formulate a chance-constrained AC optimal power flow problem, which guarantees that generation, power flows and voltages remain within their bounds with a pre-defined probability. We then propose an accurate, yet tractable analytical reformulation of the chance constraints. The reformulation maintains the full, non-linear AC power flow equations for the forecasted operating point, and models the impact of uncertainty through a linearization around this point. We discuss different solution algorithms, including one-shot optimization with and without recourse, and an iterative algorithm which enables scalable implementations. We further discuss how more general chance constraint reformulations can be incorporated within the iterative solution algorithm. In a case study based on four different IEEE systems, we compare the performance of the solution algorithms, and demonstrate scalability of the iterative scheme. We further show that the analytical reformulation accurately and efficiently enforces chance constraints in both in- and out-of-sample tests, and that the analytical approach outperforms two alternative, sample based chance constraint reformulations.
△ Less
Submitted 3 May, 2019; v1 submitted 10 June, 2017;
originally announced June 2017.
-
Battery Degradation Maps for Power System Optimization and as a Benchmark Reference
Authors:
Philipp Fortenbacher,
Göran Andersson
Abstract:
This paper presents a novel method to describe battery degradation. We use the concept of degradation maps to model the incremental charge capacity loss as a function of discrete battery control actions and state of charge. The maps can be scaled to represent any battery system in size and power. Their convex piece-wise affine representations allow for tractable optimal control formulations and ca…
▽ More
This paper presents a novel method to describe battery degradation. We use the concept of degradation maps to model the incremental charge capacity loss as a function of discrete battery control actions and state of charge. The maps can be scaled to represent any battery system in size and power. Their convex piece-wise affine representations allow for tractable optimal control formulations and can be used in power system simulations to incorporate battery degradation. The map parameters for different battery technologies are published making them an useful basis to benchmark different battery technologies in case studies.
△ Less
Submitted 10 March, 2017;
originally announced March 2017.
-
Impact of Dynamic Line Rating on Dispatch Decisions and Integration of Variable RES Energy
Authors:
Bolun Xu,
Andreas Ulbig,
Goran Andersson
Abstract:
Dynamic line rating (DLR) models the transmission capacity of overhead lines as a function of ambient conditions. It takes advantage of the physical thermal property of overhead line conductors, thus making DLR less conservative compared to the traditional worst-case oriented nominal line rating (NLR). Employing DLR brings potential benefits for grid integration of variable Renewable Energy Source…
▽ More
Dynamic line rating (DLR) models the transmission capacity of overhead lines as a function of ambient conditions. It takes advantage of the physical thermal property of overhead line conductors, thus making DLR less conservative compared to the traditional worst-case oriented nominal line rating (NLR). Employing DLR brings potential benefits for grid integration of variable Renewable Energy Sources (RES), such as wind and solar energy. In this paper, we reproduce weather conditions from renewable feed-ins and local temperature records, and calculate DLR in accordance with the RES feed-in and load demand data step. Simulations with high time resolution, using a predictive dispatch optimization and the Power Node modeling framework, of a six-node benchmark power system loosely based on the German power system are performed for the current situation, using actual wind and PV feed-in data. The integration capability of DLR under high RES production shares is inspected through simulations with scaled-up RES profiles and reduced dispatchable generation capacity. The simulation result demonstrates a comparison between DLR and NLR in terms of reductions in RES generation curtailments and load shedding, while discussions on the practicality of adopting DLR in the current power system is given in the end.
△ Less
Submitted 2 December, 2016;
originally announced December 2016.
-
Characterizing the gamma-ray long-term variability of PKS 2155-304 with H.E.S.S. and Fermi-LAT
Authors:
H. E. S. S. Collaboration,
H. Abdalla,
A. Abramowski,
F. Aharonian,
F. Ait Benkhali,
A. G. Akhperjanian T. Andersson,
M. Arrieta,
P. Aubert,
M. Backes,
A. Balzer,
M. Barnard,
Y. Becherini,
J. Becker Tjus,
D. Berge S. Bernhard,
K. Bernlöhr,
R. Blackwell,
M. Böttcher,
C. Boisson,
J. Bolmont,
P. Bordas,
J. Bregeon,
F. Brun,
P. Brun,
M. Bryan,
T. Bulik
, et al. (222 additional authors not shown)
Abstract:
Studying the temporal variability of BL Lac objects at the highest energies provides unique insights into the extreme physical processes occurring in relativistic jets and in the vicinity of super-massive black holes. To this end, the long-term variability of the BL Lac object PKS 2155-304 is analyzed in the high (HE, 100 MeV < E < 300 GeV) and very high energy (VHE, E > 200 GeV) gamma-ray domain.…
▽ More
Studying the temporal variability of BL Lac objects at the highest energies provides unique insights into the extreme physical processes occurring in relativistic jets and in the vicinity of super-massive black holes. To this end, the long-term variability of the BL Lac object PKS 2155-304 is analyzed in the high (HE, 100 MeV < E < 300 GeV) and very high energy (VHE, E > 200 GeV) gamma-ray domain. Over the course of ~9 yr of H.E.S.S observations the VHE light curve in the quiescent state is consistent with a log-normal behavior. The VHE variability in this state is well described by flicker noise (power-spectral-density index ß_VHE = 1.10 +0.10 -0.13) on time scales larger than one day. An analysis of 5.5 yr of HE Fermi LAT data gives consistent results (ß_HE = 1.20 +0.21 -0.23, on time scales larger than 10 days) compatible with the VHE findings. The HE and VHE power spectral densities show a scale invariance across the probed time ranges. A direct linear correlation between the VHE and HE fluxes could neither be excluded nor firmly established. These long-term-variability properties are discussed and compared to the red noise behavior (ß ~ 2) seen on shorter time scales during VHE-flaring states. The difference in power spectral noise behavior at VHE energies during quiescent and flaring states provides evidence that these states are influenced by different physical processes, while the compatibility of the HE and VHE long-term results is suggestive of a common physical link as it might be introduced by an underlying jet-disk connection.
△ Less
Submitted 11 October, 2016;
originally announced October 2016.
-
Fast and Reliable Primary Frequency Reserves From Refrigerators with Decentralized Stochastic Control
Authors:
Evangelos Vrettos,
Charalampos Ziras,
Göran Andersson
Abstract:
Due to increasing shares of renewable energy sources, more frequency reserves are required to maintain power system stability. In this paper, we present a decentralized control scheme that allows a large aggregation of refrigerators to provide Primary Frequency Control (PFC) reserves to the grid based on local frequency measurements and without communication.
The control is based on stochastic s…
▽ More
Due to increasing shares of renewable energy sources, more frequency reserves are required to maintain power system stability. In this paper, we present a decentralized control scheme that allows a large aggregation of refrigerators to provide Primary Frequency Control (PFC) reserves to the grid based on local frequency measurements and without communication.
The control is based on stochastic switching of refrigerators depending on the frequency deviation. We develop methods to account for typical lockout constraints of compressors and increased power consumption during the startup phase. In addition, we propose a procedure to dynamically reset the thermostat temperature limits in order to provide reliable PFC reserves, as well as a corrective temperature feedback loop to build robustness to biased frequency deviations. Furthermore, we introduce an additional randomization layer in the controller to account for thermostat resolution limitations, and finally, we modify the control design to account for refrigerator door openings.
Extensive simulations with actual frequency signal data and with different aggregation sizes, load characteristics, and control parameters, demonstrate that the proposed controller outperforms a relevant state-of-the-art controller.
△ Less
Submitted 4 October, 2016;
originally announced October 2016.
-
Optimal Placement and Sizing of Distributed Battery Storage in Low Voltage Grids using Receding Horizon Control Strategies
Authors:
Philipp Fortenbacher,
Andreas Ulbig,
Göran Andersson
Abstract:
In this paper we present a novel methodology for leveraging Receding Horizon Control (RHC), also known as Model Predictive Control (MPC) strategies for distributed battery storage in a planning problem using a Benders decomposition technique. Longer prediction horizons lead to better storage placement strategies but also higher computational complexity that can quickly become computationally prohi…
▽ More
In this paper we present a novel methodology for leveraging Receding Horizon Control (RHC), also known as Model Predictive Control (MPC) strategies for distributed battery storage in a planning problem using a Benders decomposition technique. Longer prediction horizons lead to better storage placement strategies but also higher computational complexity that can quickly become computationally prohibitive. The here proposed MPC strategy in conjunction with a Benders decomposition technique effectively reduces the computational complexity to a manageable level. We use the CIGRE low voltage (LV) benchmark grid as a case study for solving an optimal placement and sizing problem for different control strategies with different MPC prediction horizons. The objective of the MPC strategy is to maximize the photovoltaic (PV) utilization and minimize battery degradation in a local residential area, while satisfying all grid constraints. For this case study we show that the economic value of battery storage is higher when using MPC based storage control strategies than when using heuristic storage control strategies, because MPC strategies explicitly exploit the value of forecast information. The economic merit of this approach can be further increased by explicitly incorporating a battery degradation model in the MPC strategy.
△ Less
Submitted 25 August, 2017; v1 submitted 22 September, 2016;
originally announced September 2016.
-
Corrective Control to Handle Forecast Uncertainty: A Chance Constrained Optimal Power Flow
Authors:
Line Roald,
Sidhant Misra,
Thilo Krause,
Goran Andersson
Abstract:
Higher shares of electricity generation from renewable energy sources and market liberalization is increasing uncertainty in power systems operation. At the same time, operation is becoming more flexible with improved control systems and new technology such as phase shifting transformers (PSTs) and high voltage direct current connections (HVDC). Previous studies have shown that the use of correcti…
▽ More
Higher shares of electricity generation from renewable energy sources and market liberalization is increasing uncertainty in power systems operation. At the same time, operation is becoming more flexible with improved control systems and new technology such as phase shifting transformers (PSTs) and high voltage direct current connections (HVDC). Previous studies have shown that the use of corrective control in response to outages contributes to a reduction in operating cost, while maintaining N-1 security. In this work, we propose a method to extend the use of corrective control of PSTs and HVDCs to react to uncertainty. We characterize the uncertainty as continuous random variables, and define the corrective control actions through affine control policies. This allows us to efficiently model control reactions to a large number of uncertainty sources. The control policies are then included in a chance constrained optimal power flow formulation, which guarantees that the system constraints are enforced with a desired probability. By applying an analytical reformulation of the chance constraints, we obtain a second-order cone problem for which we develop an efficient solution algorithm. In a case study for the IEEE 118 bus system, we show that corrective control for uncertainty leads to a decrease in operational cost, while maintaining system security. Further, we demonstrate the scalability of the method by solving the problem for the IEEE 300 bus and the Polish system test cases.
△ Less
Submitted 7 September, 2016;
originally announced September 2016.
-
Experimental Demonstration of Frequency Regulation by Commercial Buildings - Part I: Modeling and Hierarchical Control Design
Authors:
Evangelos Vrettos,
Emre C. Kara,
Jason MacDonald,
Göran Andersson,
Duncan S. Callaway
Abstract:
This paper is the first part of a two-part series in which we present results from an experimental demonstration of frequency regulation in a commercial building test facility.
In Part I, we introduce the test facility and develop relevant building models. Furthermore, we design a hierarchical controller that consists of three levels: a reserve scheduler, a building climate controller, and a fan…
▽ More
This paper is the first part of a two-part series in which we present results from an experimental demonstration of frequency regulation in a commercial building test facility.
In Part I, we introduce the test facility and develop relevant building models. Furthermore, we design a hierarchical controller that consists of three levels: a reserve scheduler, a building climate controller, and a fan speed controller for frequency regulation. We formulate the reserve scheduler as a robust optimization problem and introduce several approximations to reduce its complexity. The building climate controller is comprised of a robust model predictive controller and a Kalman filter. The frequency regulation controller consists of a feedback and a feedforward loop, provides fast responses, and is stable.
Part I presents building model identification and controller tuning results, whereas Part II reports results from the operation of the hierarchical controller under frequency regulation.
△ Less
Submitted 19 May, 2016;
originally announced May 2016.
-
Experimental Demonstration of Frequency Regulation by Commercial Buildings - Part II: Results and Performance Evaluation
Authors:
Evangelos Vrettos,
Emre C. Kara,
Jason MacDonald,
Göran Andersson,
Duncan S. Callaway
Abstract:
This paper is the second part of a two-part series presenting the results from an experimental demonstration of frequency regulation in a commercial building test facility. In Part I, we developed relevant building models and designed a hierarchical controller for reserve scheduling, building climate control and frequency regulation.
In Part II, we introduce the communication architecture and ex…
▽ More
This paper is the second part of a two-part series presenting the results from an experimental demonstration of frequency regulation in a commercial building test facility. In Part I, we developed relevant building models and designed a hierarchical controller for reserve scheduling, building climate control and frequency regulation.
In Part II, we introduce the communication architecture and experiment settings, and present extensive experimental results under frequency regulation. More specifically, we compute the day-ahead reserve capacity of the test facility under different assumptions and conditions. Furthermore, we demonstrate the ability of model predictive control to satisfy comfort constraints under frequency regulation, and show that fan speed control can track the fast-moving RegD signal of the Pennsylvania, Jersey, and Maryland Power Market (PJM) very accurately. In addition, we report the observed effects of frequency regulation on building control and provide suggestions for realworld implementation projects. Our results show that hierarchical control is appropriate for frequency regulation from commercial buildings.
△ Less
Submitted 18 May, 2016;
originally announced May 2016.
-
Modeling and Optimal Operation of Distributed Battery Storage in Low Voltage Grids
Authors:
Philipp Fortenbacher,
Johanna L. Mathieu,
Göran Andersson
Abstract:
Due to high power in-feed from photovoltaics, it can be expected that more battery systems will be installed in the distribution grid in near future to mitigate voltage violations and thermal line and transformer overloading. In this paper, we present a two-stage centralized model predictive control scheme for distributed battery storage that consists of a scheduling entity and a real-time control…
▽ More
Due to high power in-feed from photovoltaics, it can be expected that more battery systems will be installed in the distribution grid in near future to mitigate voltage violations and thermal line and transformer overloading. In this paper, we present a two-stage centralized model predictive control scheme for distributed battery storage that consists of a scheduling entity and a real-time control entity. To guarantee secure grid operation, we solve a robust multi-period optimal power flow (OPF) for the scheduling stage that minimizes battery degradation and maximizes photovoltaic utilization subject to grid constraints. The real-time controller solves a real-time OPF taking into account storage allocation profiles from the scheduler, a detailed battery model, and real-time measurements. To reduce the computational complexity of the controllers, we present a linearized OPF that approximates the nonlinear AC-OPF into a linear programming problem. Through a case study, we show, for two different battery technologies, that we can substantially reduce battery degradation when we incorporate a battery degradation model. A further finding is that we can reduce battery losses by 30% by using the detailed battery model in the real-time control stage.
△ Less
Submitted 16 March, 2017; v1 submitted 21 March, 2016;
originally announced March 2016.
-
Chance Constrained Optimal Power Flow with Curtailment and Reserves from Wind Power Plants
Authors:
Line Roald,
Sidhant Misra,
Michael Chertkov,
Scott Backhaus,
Göran Andersson
Abstract:
Over the past years, the share of electricity production from wind power plants has increased to significant levels in several power systems across Europe and the United States. In order to cope with the fluctuating and partially unpredictable nature of renewable energy sources, transmission system operators (TSOs) have responded by increasing their reserve capacity requirements and by requiring w…
▽ More
Over the past years, the share of electricity production from wind power plants has increased to significant levels in several power systems across Europe and the United States. In order to cope with the fluctuating and partially unpredictable nature of renewable energy sources, transmission system operators (TSOs) have responded by increasing their reserve capacity requirements and by requiring wind power plants to be capable of providing reserves or following active power set-point signals. This paper addresses the issue of efficiently incorporating these new types of wind power control in the day-ahead operational planning. We review the technical requirements the wind power plants must fulfill, and propose a mathematical framework for modeling wind power control. The framework is based on an optimal power flow formulation with weighted chance constraints, which accounts for the uncertainty of wind power forecasts and allows us to limit the risk of constraint violations. In a case study based on the IEEE 118 bus system, we use the developed method to assess the effectiveness of different types of wind power control in terms of operational cost, system security and wind power curtailment.
△ Less
Submitted 17 January, 2016;
originally announced January 2016.
-
Optimal Sizing and Placement of Distributed Storage in Low Voltage Networks
Authors:
Philipp Fortenbacher,
Martin Zellner,
Göran Andersson
Abstract:
This paper proposes a novel algorithm to optimally size and place storage in low voltage (LV) networks based on a linearized multiperiod optimal power flow method which we call forward backward sweep optimal power flow (FBS-OPF). We show that this method has good convergence properties, its solution deviates slightly from the optimum and makes the storage sizing and placement problem tractable for…
▽ More
This paper proposes a novel algorithm to optimally size and place storage in low voltage (LV) networks based on a linearized multiperiod optimal power flow method which we call forward backward sweep optimal power flow (FBS-OPF). We show that this method has good convergence properties, its solution deviates slightly from the optimum and makes the storage sizing and placement problem tractable for longer investment horizons. We demonstrate the usefulness of our method by assessing the economic viability of distributed and centralized storage in LV grids with a high photovoltaic penetration (PV). As a main result, we quantify that for the CIGRE LV test grid distributed storage configurations are preferable, since they allow for less PV curtailment due to grid constraints.
△ Less
Submitted 21 March, 2016; v1 submitted 3 December, 2015;
originally announced December 2015.
-
Polyhedral Computation Based Transfer Capacities in Multi-Area Power Systems
Authors:
Alexander Fuchs,
Marc Scherer,
Göran Andersson
Abstract:
This paper proposes a new methodology to maximize the feasible set of power injections and cross-border power transfers in meshed multi-area power systems. The approach used polyhedral computation schemes and is an extension to the classic procedure for cross-border transfer capacity assessment in the European power network, including the computation of bilateral cross-border transfer capacities a…
▽ More
This paper proposes a new methodology to maximize the feasible set of power injections and cross-border power transfers in meshed multi-area power systems. The approach used polyhedral computation schemes and is an extension to the classic procedure for cross-border transfer capacity assessment in the European power network, including the computation of bilateral cross-border transfer capacities as well as multilateral flow-based approaches. The focus is the characterization of inter-area exchange limits required for secure power system operation in the presence of physical transmission constraints, while maximizing the utilization factors of the transmission lines. The numerical examples include a case study of the ENTSO-E transmission system.
△ Less
Submitted 2 November, 2015;
originally announced November 2015.
-
Security Constrained Optimal Power Flow with Distributionally Robust Chance Constraints
Authors:
Line Roald,
Frauke Oldewurtel,
Bart Van Parys,
Göran Andersson
Abstract:
The growing amount of fluctuating renewable infeeds and market liberalization increases uncertainty in power system operation. To capture the influence of fluctuations in operational planning, we model the forecast errors of the uncertain in-feeds as random variables and formulate a security constrained optimal power flow using chance constraints. The chance constraints limit the probability of vi…
▽ More
The growing amount of fluctuating renewable infeeds and market liberalization increases uncertainty in power system operation. To capture the influence of fluctuations in operational planning, we model the forecast errors of the uncertain in-feeds as random variables and formulate a security constrained optimal power flow using chance constraints. The chance constraints limit the probability of violations of technical constraints, such as generation and transmission limits, but require a tractable reformulation. In this paper, we discuss different analytical reformulations of the chance constraints, based on a given set of assumptions concerning the forecast error distributions. In particular, we discuss reformulations that do not assume a normal distribution, and admit an analytical reformulation given only a mean vector and covariance matrix. We illustrate our method with a case study of the IEEE 118 bus system, based on real data from the European system. The different reformulations are compared in terms of both achieved empirical violation probability and operational cost, which allows us to provide a suggestion for the most appropriate reformulation in an optimal power flow setting. For a large number of uncertainty sources, it is observed that the distributions of the line flows and generator outputs can be close to normal, even though the power injections are not normally distributed.
△ Less
Submitted 25 August, 2015;
originally announced August 2015.
-
Distributed Frequency Control through MTDC Transmission Systems
Authors:
Martin Andreasson,
Roger Wiget,
Dimos V. Dimarogonas,
Karl H. Johansson,
Göran Andersson
Abstract:
In this paper we propose distributed dynamic controllers for sharing both frequency containment and restoration reserves of asynchronous AC systems connected through a multi-terminal HVDC (MTDC) grid. The communication structure of the controller is distributed in the sense that only local and neighboring state information is needed, rather than the complete state. We derive sufficient stability c…
▽ More
In this paper we propose distributed dynamic controllers for sharing both frequency containment and restoration reserves of asynchronous AC systems connected through a multi-terminal HVDC (MTDC) grid. The communication structure of the controller is distributed in the sense that only local and neighboring state information is needed, rather than the complete state. We derive sufficient stability conditions, which guarantee that the AC frequencies converge to the nominal frequency. Simultaneously, a global quadratic power generation cost function is minimized. The proposed controller also regulates the voltages of the MTDC grid, asymptotically minimizing a quadratic cost function of the deviations from the nominal DC voltages. The results are valid for distributed cable models of the HVDC grid (e.g. $π$-links), as well as AC systems of arbitrary number of synchronous machines, each modeled by the swing equation. We also propose a decentralized, communication-free version of the controller. The proposed controllers are tested on a high-order dynamic model of a power system consisting of asynchronous AC grids, modelled as IEEE 14 bus networks, connected through a six-terminal HVDC grid. The performance of the controller is successfully evaluated through simulation.
△ Less
Submitted 11 December, 2015; v1 submitted 7 July, 2015;
originally announced July 2015.
-
A Fully Controllable Power System - Concept for FACTS and HVDC Placement
Authors:
Spyros Chatzivasileiadis,
Göran Andersson
Abstract:
This paper puts forward the vision of fully decoupling market operations from security considerations through controllable power flows. In "A Fully Controllable Power System", power system security is no longer dependent on the location of the power injection points. In the ideal case, this leads to the elimination of redispatching costs, which amount to several million dollars per year in large s…
▽ More
This paper puts forward the vision of fully decoupling market operations from security considerations through controllable power flows. In "A Fully Controllable Power System", power system security is no longer dependent on the location of the power injection points. In the ideal case, this leads to the elimination of redispatching costs, which amount to several million dollars per year in large systems. This paper determines the upper and lower bounds for the number of controllable lines and number of controllers to achieve this decoupling in any system. It further introduces the notion of the controllability vector CV, which expresses the effect of any controller on the AC line flows. Based on two alternative definitions for controllability, two controller placement algorithms to maximize controllability are presented and their results are compared.
△ Less
Submitted 26 June, 2015;
originally announced June 2015.
-
Robust Energy-Constrained Frequency Reserves from Aggregations of Commercial Buildings
Authors:
Evangelos Vrettos,
Frauke Oldewurtel,
Göran Andersson
Abstract:
It has been shown that the heating, ventilation, and air conditioning (HVAC) systems of commercial buildings can offer ancillary services to power systems without loss of comfort. In this paper, we propose a new control framework for reliable scheduling and provision of frequency reserves by aggregations of commercial buildings. The framework incorporates energy-constrained frequency signals, whic…
▽ More
It has been shown that the heating, ventilation, and air conditioning (HVAC) systems of commercial buildings can offer ancillary services to power systems without loss of comfort. In this paper, we propose a new control framework for reliable scheduling and provision of frequency reserves by aggregations of commercial buildings. The framework incorporates energy-constrained frequency signals, which are adopted by several transmission system operators for loads and storage devices. We use a hierarchical approach with three levels: (i) reserve capacities are allocated among buildings (e.g., on a daily basis) using techniques from robust optimization, (ii) a robust model predictive controller optimizes the HVAC system consumption typically every 30 minutes, and (iii) a feedback controller adjusts the consumption to provide reserves in real time. We demonstrate how the framework can be used to estimate the reserve capacities in simulations with typical Swiss office buildings and different reserve product characteristics. Our results show that an aggregation of approximately 100 buildings suffices to meet the 5 MW minimum bid size of the Swiss reserve market.
△ Less
Submitted 17 June, 2015;
originally announced June 2015.
-
Coordinated Frequency Control through MTDC Transmission Systems
Authors:
Martin Andreasson,
Roger Wiget,
Dimos V. Dimarogonas,
Karl H. Johansson,
Göran Andersson
Abstract:
In this paper we propose a distributed dynamic controller for sharing frequency control reserves of asynchronous AC systems connected through a multi-terminal HVDC (MTDC) grid. We derive sufficient stability conditions, which guarantee that the frequencies of the AC systems converge to the nominal frequency. Simultaneously, the global quadratic cost of power generation is minimized, resulting in a…
▽ More
In this paper we propose a distributed dynamic controller for sharing frequency control reserves of asynchronous AC systems connected through a multi-terminal HVDC (MTDC) grid. We derive sufficient stability conditions, which guarantee that the frequencies of the AC systems converge to the nominal frequency. Simultaneously, the global quadratic cost of power generation is minimized, resulting in an optimal distribution of generation control reserves. The proposed controller also regulates the voltages of the MTDC grid, asymptotically minimizing a quadratic cost function of the deviations from the nominal voltages. The proposed controller is tested on a high-order dynamic model of a power system consisting of asynchronous AC grids, modelled as IEEE 14 bus networks, connected through a six-terminal HVDC grid. The performance of the controller is successfully evaluated through simulation.
△ Less
Submitted 11 December, 2015; v1 submitted 27 May, 2015;
originally announced May 2015.
-
Optimal Power Flow with Weighted Chance Constraints and General Policies for Generation Control
Authors:
Line Roald,
Sidhant Misra,
Michael Chertkov,
Göran Andersson
Abstract:
Due to the increasing amount of electricity generated from renewable sources, uncertainty in power system operation will grow. This has implications for tools such as Optimal Power Flow (OPF), an optimization problem widely used in power system operations and planning, which should be adjusted to account for this uncertainty. One way to handle the uncertainty is to formulate a Chance Constrained O…
▽ More
Due to the increasing amount of electricity generated from renewable sources, uncertainty in power system operation will grow. This has implications for tools such as Optimal Power Flow (OPF), an optimization problem widely used in power system operations and planning, which should be adjusted to account for this uncertainty. One way to handle the uncertainty is to formulate a Chance Constrained OPF (CC-OPF) which limits the probability of constraint violation to a predefined value. However, existing CC-OPF formulations and solutions are not immune to drawbacks. On one hand, they only consider affine policies for generation control, which are not always realistic and may be sub-optimal. On the other hand, the standard CC-OPF formulations do not distinguish between large and small violations, although those might carry significantly different risk. In this paper, we introduce the Weighted CC-OPF (WCC-OPF) that can handle general control policies while preserving convexity and allowing for efficient computation. The weighted chance constraints account for the size of violations through a weighting function, which assigns a higher risk to a higher overloads. We prove that the problem remains convex for any convex weighting function, and for very general generation control policies. In a case study, we compare the performance of the new WCC-OPF and the standard CC-OPF and demonstrate that WCC-OPF effectively reduces the number of severe overloads. Furthermore, we compare an affine generation control policy with a more general policy, and show that the additional flexibility allow for a lower cost while maintaining the same level of risk.
△ Less
Submitted 31 March, 2015;
originally announced April 2015.
-
Distributed Secondary Frequency Control through MTDC Transmission Systems
Authors:
Martin Andreasson,
Roger Wiget,
Dimos V. Dimarogonas,
Karl H. Johansson,
Göran Andersson
Abstract:
In this paper, we present distributed controllers for sharing primary and secondary frequency control reserves for asynchronous AC transmission systems, which are connected through a multi-terminal HVDC grid. By using Lyapunov arguments, the equilibria of the closed-loop system are shown to be globally asymptotically stable. We quantify the static errors of the voltages and frequencies, and give u…
▽ More
In this paper, we present distributed controllers for sharing primary and secondary frequency control reserves for asynchronous AC transmission systems, which are connected through a multi-terminal HVDC grid. By using Lyapunov arguments, the equilibria of the closed-loop system are shown to be globally asymptotically stable. We quantify the static errors of the voltages and frequencies, and give upper bounds for these errors. It is also shown that the controllers have the property of power sharing, i.e., primary and secondary frequency control reserves are shared fairly amongst the AC systems. The proposed controllers are applied to a high-order dynamic model of of a power system consisting of asynchronous AC grids connected through a six-terminal HVDC grid.
△ Less
Submitted 15 December, 2015; v1 submitted 25 March, 2015;
originally announced March 2015.
-
Topology Detection in Microgrids with Micro-Synchrophasors
Authors:
Reza Arghandeh,
Martin Gahr,
Alexandra von Meier,
Guido Cavraro,
Monika Ruh,
Göran Andersson
Abstract:
Network topology in distribution networks is often unknown, because most switches are not equipped with measurement devices and communication links. However, knowledge about the actual topology is critical for safe and reliable grid operation. This paper proposes a voting-based topology detection method based on micro-synchrophasor measurements. The minimal difference between measured and calculat…
▽ More
Network topology in distribution networks is often unknown, because most switches are not equipped with measurement devices and communication links. However, knowledge about the actual topology is critical for safe and reliable grid operation. This paper proposes a voting-based topology detection method based on micro-synchrophasor measurements. The minimal difference between measured and calculated voltage angle or voltage magnitude, respectively, indicates the actual topology. Micro-synchrophasors or micro-Phasor Measurement Units (μPMU) are high-precision devices that can measure voltage angle differences on the order of ten millidegrees. This accuracy is important for distribution networks due to the smaller angle differences as compared to transmission networks. For this paper, a microgrid test bed is implemented in MATLAB with simulated measurements from μPMUs as well as SCADA measurement devices. The results show that topologies can be detected with high accuracy. Additionally, topology detection by voltage angle shows better results than detection by voltage magnitude.
△ Less
Submitted 7 January, 2015;
originally announced February 2015.
-
Robust Corrective Control Measures in Power Systems with Dynamic Line Rating
Authors:
Matthias A. Bucher,
Göran Andersson
Abstract:
Dynamic Thermal Line Rating (DLR) is deemed to be an effective way to increase transmission capacities and therefore enabling additional operational flexibility. The transmission capacities are dynamically determined based on current or expected weather conditions. First pilot projects have proven its efficiency. In this paper we present two approaches to determine the location and amount of rampi…
▽ More
Dynamic Thermal Line Rating (DLR) is deemed to be an effective way to increase transmission capacities and therefore enabling additional operational flexibility. The transmission capacities are dynamically determined based on current or expected weather conditions. First pilot projects have proven its efficiency. In this paper we present two approaches to determine the location and amount of ram** capabilities for corrective control measures in the case of errors in the forecast of the line rating. Both approaches result in robust optimization problems, where the first approach guarantees that there is a suitable remedial action for every realization of uncertainty in a given uncertainty set. The corrective control action is calculated once the forecast error is known. The second approach relies on affine policies which directly relate the current line rating to corrective control measures, if needed, which enables a decentralized operation. In case studies, the two approaches are compared and the reduction of overall operational costs is demonstrated exemplarily for different parameters.
△ Less
Submitted 31 October, 2014;
originally announced October 2014.
-
Distributed Primary Frequency Control through Multi-Terminal HVDC Transmission Systems
Authors:
Martin Andreasson,
Roger Wiget,
Dimos V. Dimarogonas,
Karl H. Johansson,
Göran Andersson
Abstract:
This paper presents a decentralized controller for sharing primary AC frequency control reserves through a multi-terminal HVDC grid. By using Lyapunov arguments, the proposed controller is shown to stabilize the equilibrium of the closed-loop system consisting of the interconnected AC and HVDC grids, given any positive controller gains. The static control errors resulting from the proportional con…
▽ More
This paper presents a decentralized controller for sharing primary AC frequency control reserves through a multi-terminal HVDC grid. By using Lyapunov arguments, the proposed controller is shown to stabilize the equilibrium of the closed-loop system consisting of the interconnected AC and HVDC grids, given any positive controller gains. The static control errors resulting from the proportional controller are quantified and bounded by analyzing the equilibrium of the closed-loop system. The proposed controller is applied to a test grid consisting of three asynchronous AC areas interconnected by an HVDC grid, and its effectiveness is validated through simulation.
△ Less
Submitted 11 December, 2015; v1 submitted 29 September, 2014;
originally announced September 2014.
-
Managing Flexibility in Multi-Area Power Systems
Authors:
Matthias Bucher,
Spyros Chatzivasileiadis,
Göran Andersson
Abstract:
In this paper we present a framework to efficiently characterize the available operational flexibility in a multi-area power system. We focus on the available reserves and the tie-line flows. The proposed approach is an alternative to the current calculation of the Available Transfer Capacity (ATC), as it considers location and availability of reserves, transmission constraints, and interdependenc…
▽ More
In this paper we present a framework to efficiently characterize the available operational flexibility in a multi-area power system. We focus on the available reserves and the tie-line flows. The proposed approach is an alternative to the current calculation of the Available Transfer Capacity (ATC), as it considers location and availability of reserves, transmission constraints, and interdependencies of tie-line flows between different areas, while it takes into account the N-1 security criterion. The method is based on computational geometry using polytopic projections. It requires only a limited amount of information exchange and does not need central coordination. The method has two versions: a passive and an active approach, where neighboring areas can share reserves. In that respect we also introduce the term "exported flexibility", which could form the basis for a new trading product in electricity markets. Case studies demonstrate the improved tie-line utilization, especially if reserves are shared, and the visualization benefits.
△ Less
Submitted 8 September, 2014;
originally announced September 2014.
-
PV Integration in Low-Voltage Feeders with Demand Response
Authors:
Xiangkun Li,
Theodor Borsche,
Göran Andersson
Abstract:
Increased distributed Photo-Voltaic (PV) generation leads to an increase in voltages and unwarranted backflows into the grid. This paper investigates Demand Response (DR) with Electric Water Heaters (EWHs) as a way to increase the PV hosting capacity of a low-voltage feeder. A control strategy relying only on power measurements at the transformer is proposed. Flexible loads are optimally dispatche…
▽ More
Increased distributed Photo-Voltaic (PV) generation leads to an increase in voltages and unwarranted backflows into the grid. This paper investigates Demand Response (DR) with Electric Water Heaters (EWHs) as a way to increase the PV hosting capacity of a low-voltage feeder. A control strategy relying only on power measurements at the transformer is proposed. Flexible loads are optimally dispatched considering energy acquisition costs, a PV shedding penalty, and power and energy constraints. Furthermore, grou** of loads and PV plants is investigated, and switching penalties are used to reduce the unnecessary switching of loads. It is shown that this strategy can substantially increase the PV hosting capacity of a Low-Voltage (LV) feeder, even when only basic controllability is available.
△ Less
Submitted 7 August, 2014;
originally announced August 2014.
-
Grid Integration Costs of Fluctuating Renewable Energy Sources
Authors:
Jonas Müller,
Marcus Hildmann,
Andreas Ulbig,
Göran Andersson
Abstract:
The grid integration of intermittent Renewable Energy Sources (RES) causes costs for grid operators due to forecast uncertainty and the resulting production schedule mismatches. These so-called profile service costs are marginal cost components and can be understood as an insurance fee against RES production schedule uncertainty that the system operator incurs due to the obligation to always provi…
▽ More
The grid integration of intermittent Renewable Energy Sources (RES) causes costs for grid operators due to forecast uncertainty and the resulting production schedule mismatches. These so-called profile service costs are marginal cost components and can be understood as an insurance fee against RES production schedule uncertainty that the system operator incurs due to the obligation to always provide sufficient control reserve capacity for power imbalance mitigation. This paper studies the situation for the German power system and the existing German RES support schemes. The profile service costs incurred by German Transmission System Operators (TSOs) are quantified and means for cost reduction are discussed. In general, profile service costs are dependent on the RES prediction error and the specific workings of the power markets via which the prediction error is balanced. This paper shows both how the prediction error can be reduced in daily operation as well as how profile service costs can be reduced via optimization against power markets and/or active curtailment of RES generation.
△ Less
Submitted 27 July, 2014;
originally announced July 2014.
-
Model Predictive Frequency Control Employing Stability Constraints
Authors:
Christoph Trabert,
Andreas Ulbig,
Göran Andersson
Abstract:
In this article a model predictive control (MPC) based frequency control scheme for energy storage units was derived, focusing on the incorporation of stability constraints based on Lyapunov theory and the concept of passivity. The proposed control schemes, guaranteeing closed-loop stability, are applied on a one-area and two-area power system. For the two-area power system, a coordinated (central…
▽ More
In this article a model predictive control (MPC) based frequency control scheme for energy storage units was derived, focusing on the incorporation of stability constraints based on Lyapunov theory and the concept of passivity. The proposed control schemes, guaranteeing closed-loop stability, are applied on a one-area and two-area power system. For the two-area power system, a coordinated (centralized) control and an uncoordinated (decentralized) control approach is conducted. The stability properties of the different MPC setups were derived, implemented and simulated. Furthermore the corresponding control performance was analyzed.
△ Less
Submitted 26 May, 2014;
originally announced May 2014.
-
Medium-term optimization of pumped hydro storage with stochastic intrastage subproblems
Authors:
Hubert Abgottspon,
Göran Andersson
Abstract:
This paper presents a medium-term self-scheduling optimization of pumped hydro storage power plants with detailed consideration of short-term flexibility. A decomposition of the problem into inter- and intrastage subproblems, where the intrastage problems themselves are formulated as multi-stage stochastic programs, allows the detailed consideration of short- term flexibility. The method is presen…
▽ More
This paper presents a medium-term self-scheduling optimization of pumped hydro storage power plants with detailed consideration of short-term flexibility. A decomposition of the problem into inter- and intrastage subproblems, where the intrastage problems themselves are formulated as multi-stage stochastic programs, allows the detailed consideration of short- term flexibility. The method is presented together with three alter- native approaches, where the short-term flexibility is considered differently: (1) with aggregated peak and off-peak prices, (2) with price duration curves and (3) with deterministic intrastage subproblems. The methods are compared and evaluated in a Monte Carlo operation simulation study. The study is performed on a realistic hydro power plant with consideration of revenue from ancillary services.
△ Less
Submitted 19 March, 2014;
originally announced March 2014.
-
Re-entrant superspin glass phase in La$_{0.82}$Ca$_{0.18}$MnO$_3$ ferromagnetic insulator
Authors:
P. Anil Kumar,
R. Mathieu,
P. Nordblad,
Sugata Ray,
Olof Karis,
Gabriella Andersson,
D. D. Sarma
Abstract:
We report results of magnetization and ac susceptibility measurements down to very low fields on a single crystal of the perovskite manganite, La$_{0.82}$Ca$_{0.18}$MnO$_3$. This composition falls in the intriguing ferromagnetic insulator region of the manganite phase diagram. In contrast to earlier beliefs, our investigations reveal that the system is magnetically (and in every other sense) singl…
▽ More
We report results of magnetization and ac susceptibility measurements down to very low fields on a single crystal of the perovskite manganite, La$_{0.82}$Ca$_{0.18}$MnO$_3$. This composition falls in the intriguing ferromagnetic insulator region of the manganite phase diagram. In contrast to earlier beliefs, our investigations reveal that the system is magnetically (and in every other sense) single-phase with a ferromagnetic ordering temperature of $\sim$ 170 K. However, this ferromagnetic state is magnetically frustrated, and the system exhibits pronounced glassy dynamics below 90 K. Based on measured dynamical properties, we propose that this quasi-long-ranged ferromagnetic phase, and associated superspin glass behavior, is the true magnetic state of the system, rather than being a macroscopic mixture of ferromagnetic and antiferromagnetic phases as often suggested. Our results provide an understanding of the quantum phase transition from an antiferromagnetic insulator to a ferromagnetic metal via this ferromagnetic insulating state as a function of $x$ in La$_{1-x}$Ca$_x$MnO$_3$, in terms of the possible formation of magnetic polarons.
△ Less
Submitted 5 February, 2014;
originally announced February 2014.
-
Analyzing Operational Flexibility of Power Systems
Authors:
Andreas Ulbig,
Göran Andersson
Abstract:
Operational flexibility is an important property of electric power systems and plays a crucial role for the transition of today's power systems, many of them based on fossil fuels, towards power systems that can efficiently accommodate high shares of variable Renewable Energy Sources (RES). The availability of sufficient operational flexibility in a given power system is a necessary prerequisite f…
▽ More
Operational flexibility is an important property of electric power systems and plays a crucial role for the transition of today's power systems, many of them based on fossil fuels, towards power systems that can efficiently accommodate high shares of variable Renewable Energy Sources (RES). The availability of sufficient operational flexibility in a given power system is a necessary prerequisite for the effective grid integration of large shares of fluctuating power in-feed from variable RES, especially wind power and Photovoltaics (PV). This paper establishes the necessary framework for quantifying and visualizing the technically available operational flexibility of individual power system units and ensembles thereof. Necessary metrics for defining power system operational flexibility, namely the power ramp-rate, power and energy capability of generators, loads and storage devices, are presented. The flexibility properties of different power system unit types, e.g. load, generation and storage units that are non-controllable, curtailable or fully controllable are qualitatively analyzed and compared to each other. Quantitative results and flexibility visualizations are presented for intuitive power system examples.
△ Less
Submitted 27 July, 2014; v1 submitted 29 December, 2013;
originally announced December 2013.
-
Impact of Low Rotational Inertia on Power System Stability and Operation
Authors:
Andreas Ulbig,
Theodor S. Borsche,
Göran Andersson
Abstract:
Large-scale deployment of RES has led to significant generation shares of variable RES in power systems worldwide. RES units, notably inverter-connected wind turbines and PV that as such do not provide rotational inertia, are effectively displacing conventional generators and their rotating machinery. The traditional assumption that grid inertia is sufficiently high with only small variations over…
▽ More
Large-scale deployment of RES has led to significant generation shares of variable RES in power systems worldwide. RES units, notably inverter-connected wind turbines and PV that as such do not provide rotational inertia, are effectively displacing conventional generators and their rotating machinery. The traditional assumption that grid inertia is sufficiently high with only small variations over time is thus not valid for power systems with high RES shares. This has implications for frequency dynamics and power system stability and operation. Frequency dynamics are faster in power systems with low rotational inertia, making frequency control and power system operation more challenging. This paper investigates the impact of low rotational inertia on power system stability and operation, contributes new analysis insights and offers mitigation options for low inertia impacts.
△ Less
Submitted 22 December, 2014; v1 submitted 22 December, 2013;
originally announced December 2013.
-
A New Frequency Control Reserve Framework based on Energy-Constrained Units
Authors:
Theodor Borsche,
Andreas Ulbig,
Göran Andersson
Abstract:
Frequency control reserves are an essential ancillary service in any electric power system, guaranteeing that generation and demand of active power are balanced at all times. Traditionally, conventional power plants are used for frequency reserves. There are economical and technical benefits of instead using energy constrained units such as storage systems and demand response, but so far they have…
▽ More
Frequency control reserves are an essential ancillary service in any electric power system, guaranteeing that generation and demand of active power are balanced at all times. Traditionally, conventional power plants are used for frequency reserves. There are economical and technical benefits of instead using energy constrained units such as storage systems and demand response, but so far they have not been widely adopted as their energy constraints prevent them from following traditional regulation signals, which sometimes are biased over long time-spans. This paper proposes a frequency control framework that splits the control signals according to the frequency spectrum. This guarantees that all control signals are zero-mean over well-defined time-periods, which is a crucial requirement for the usage of energy-constraint units such as batteries. A case-study presents a possible implementation, and shows how different technologies with widely varying characteristics can all participate in frequency control reserve provision, while guaranteeing that their respective energy constraints are always fulfilled.
△ Less
Submitted 20 December, 2013;
originally announced December 2013.
-
Revisiting the Merit-Order Effect of Renewable Energy Sources
Authors:
Marcus Hildmann,
Andreas Ulbig,
Göran Andersson
Abstract:
An on-going debate in the energy economics and power market community has raised the question if energy-only power markets are increasingly failing due to growing feed-in shares from subsidized renewable energy sources (RES). The short answer to this is: No, they are not failing. Energy-based power markets are, however, facing several market distortions, namely from the gap between the electricity…
▽ More
An on-going debate in the energy economics and power market community has raised the question if energy-only power markets are increasingly failing due to growing feed-in shares from subsidized renewable energy sources (RES). The short answer to this is: No, they are not failing. Energy-based power markets are, however, facing several market distortions, namely from the gap between the electricity volume traded at day-ahead markets versus the overall electricity consumption as well as the (wrong) regulatory assumption that variable RES generation, i.e., wind and photovoltaic (PV), truly have zero marginal operation costs. In this paper we show that both effects over-amplify the well-known merit-order effect of RES power feed-in beyond a level that is explainable by underlying physical realities, i.e., thermal power plants being willing to accept negative electricity prices to be able to stay online due to considerations of wear & tear and start-stop constraints. We analyze the impacts of wind and PV power feed-in on the day-ahead market for a region that is already today experiencing significant feed-in tariff (FIT)-subsidized RES power feed-in, the EPEX German-Austrian market zone ($\approx\,$20% FIT share). Our analysis shows that, if the necessary regulatory adaptations are taken, i.e., increasing the day-ahead market's share of overall load demand and using the true marginal costs of RES units in the merit-order, energy-based power markets can remain functional despite high RES power feed-in.
△ Less
Submitted 14 November, 2014; v1 submitted 1 July, 2013;
originally announced July 2013.