  1. arXiv:2308.13126  [pdf

    physics.med-ph physics.ins-det

    A Cryogenic Tune and Match Circuit for Magnetic Resonance Microscopy at 15.2T

    Authors: Benjamin M. Hardy, Gary Drake, Shuyang Chai, Bibek Dhakal, Jonathan B. Martin, Junzhong Xu, Mark D. Does, Adam W. Anderson, Xinqiang Yan, John C. Gore

    Abstract: Signal to noise ratios (SNR) in magnetic resonance microscopy images are limited by acquisition times and the decreasing number of spins in smaller voxels. Significant SNR gains from cooling of the RF receiver are only realized when the Johnson noise generated within the RF hardware is large compared to the electromagnetic noise produced by the sample. Cryogenic cooling of imaging probes is common… ▽ More

    Submitted 24 August, 2023; originally announced August 2023.

    Comments: 33 pages, 10 figures, 1 table, 4 supplemental figures, 1 supplemental table

  2. arXiv:2301.00727  [pdf

    physics.med-ph physics.bio-ph

    Experimental demonstration of diffusion limitations on resolution and SNR in MR microscopy

    Authors: Benjamin M. Hardy, Yue Zhu, Kevin D. Harkins, Bibek Dhakal, Jonathan B. Martin, Junzhong Xu, Mark D. Does, Adam W. Anderson, John C. Gore

    Abstract: Magnetic resonance microscopy images at cellular resolution (< 10 microns) are limited by diffusion. SNR and spatial resolution suffer from the dephasing of transverse magnetization caused by diffusion of spins in strong gradients. Such effects may be reduced by using phase encoding instead of frequency encoding readout gradients. Demonstration of the benefits of phase encoding are lacking, and th… ▽ More

    Submitted 3 January, 2023; v1 submitted 2 January, 2023; originally announced January 2023.

    Comments: 36 pages, 9 figures, 1 table, and 4 supplemental figures. Submitted to Journal of Magnetic Resonance; cleaned up metadata, fixed heading typo

  3. arXiv:1912.04116  [pdf

    eess.IV cs.LG q-bio.NC q-bio.QM stat.ML

    MRI correlates of chronic symptoms in mild traumatic brain injury

    Authors: Cailey I. Kerley, Kurt G. Schilling, Justin Blaber, Beth Miller, Allen Newton, Adam W. Anderson, Bennett A. Landman, Tonia S. Rex

    Abstract: Veterans with mild traumatic brain injury (mTBI) have reported auditory and visual dysfunction that persists beyond the acute incident. The etiology behind these symptoms is difficult to characterize with current clinical imaging. These functional deficits may be caused by shear injury or micro-bleeds, which can be detected with special imaging modalities. We explore these hypotheses in a pilot st… ▽ More

    Submitted 22 June, 2020; v1 submitted 6 December, 2019; originally announced December 2019.

    Comments: SPIE Medical Imaging 2020

  4. arXiv:1911.07927  [pdf

    eess.IV cs.CV

    Deep Learning Captures More Accurate Diffusion Fiber Orientations Distributions than Constrained Spherical Deconvolution

    Authors: Vishwesh Nath, Kurt G. Schilling, Colin B. Hansen, Prasanna Parvathaneni, Allison E. Hainline, Camilo Bermudez, Andrew J. Plassard, Vaibhav Janve, Yurui Gao, Justin A. Blaber, Iwona Stępniewska, Adam W. Anderson, Bennett A. Landman

    Abstract: Confocal histology provides an opportunity to establish intra-voxel fiber orientation distributions that can be used to quantitatively assess the biological relevance of diffusion weighted MRI models, e.g., constrained spherical deconvolution (CSD). Here, we apply deep learning to investigate the potential of single shell diffusion weighted MRI to explain histologically observed fiber orientation… ▽ More

    Submitted 13 November, 2019; originally announced November 2019.

    Comments: 2 pages, 4 figures. This work was accepted and published as an abstract at ISMRM 2018 held in Paris, France

  5. arXiv:1907.06319  [pdf

    eess.IV cs.CV

    Enabling Multi-Shell b-Value Generalizability of Data-Driven Diffusion Models with Deep SHORE

    Authors: Vishwesh Nath, Ilwoo Lyu, Kurt G. Schilling, Prasanna Parvathaneni, Colin B. Hansen, Yucheng Tang, Yuankai Huo, Vaibhav A. Janve, Yurui Gao, Iwona Stepniewska, Adam W. Anderson, Bennett A. Landman

    Abstract: Intra-voxel models of the diffusion signal are essential for interpreting organization of the tissue environment at micrometer level with data at millimeter resolution. Recent advances in data driven methods have enabled direct compari-son and optimization of methods for in-vivo data with externally validated histological sections with both 2-D and 3-D histology. Yet, all existing methods make lim… ▽ More

    Submitted 22 February, 2020; v1 submitted 14 July, 2019; originally announced July 2019.

  6. arXiv:1810.04260  [pdf

    cs.CV

    Inter-Scanner Harmonization of High Angular Resolution DW-MRI using Null Space Deep Learning

    Authors: Vishwesh Nath, Prasanna Parvathaneni, Colin B. Hansen, Allison E. Hainline, Camilo Bermudez, Samuel Remedios, Justin A. Blaber, Kurt G. Schilling, Ilwoo Lyu, Vaibhav Janve, Yurui Gao, Iwona Stepniewska, Baxter P. Rogers, Allen T. Newton, L. Taylor Davis, Jeff Luci, Adam W. Anderson, Bennett A. Landman

    Abstract: Diffusion-weighted magnetic resonance imaging (DW-MRI) allows for non-invasive imaging of the local fiber architecture of the human brain at a millimetric scale. Multiple classical approaches have been proposed to detect both single (e.g., tensors) and multiple (e.g., constrained spherical deconvolution, CSD) fiber population orientations per voxel. However, existing techniques generally exhibit l… ▽ More

    Submitted 9 October, 2018; originally announced October 2018.

    Comments: 10 pages, 5 figures